Development of an ultrasound-guided proximo-medial approach for injection of the carpal flexor tendon sheath in horses and comparison with the conventional proximo-lateral ´blind` technique.
Abstract: The aim of this prospective case-control study was to describe and implement a reliable, accurate, and straightforward ultrasound-guided proximo-medial approach technique for injecting the carpal flexor tendon sheath in horses. The proximo-medial ultrasound-guided approach for intrathecal access to the carpal canal, as described in this study, was firstly developed on ten cadaveric limbs using an undiluted ionic iodinated contrast medium. Landmarks were identified, and the access point was established. Subsequently, the technique was validated in ten horses, and its efficacy was compared with the proximo-lateral ´blind` technique. For each injection, the following was recorded: successful injection (contrast within the carpal canal), number of attempts, and whether a structure other than the carpal sheath was penetrated. The ´blind` technique had a total accuracy of 70% (7/10; 95% confidence interval [CI]: CI 35%-93%), with inadvertent injection into the dorso-palmar pouch of the radiocarpal joint, carpal canal surrounding soft tissue, and intravenous injection being the most common issues associated with this approach. In contrast, the ultrasound-guided approach achieved an accuracy of 100% (10/10; 95% confidence interval [CI]: 69%-100%) for intrasynovial administration of the contrast medium. The ultrasound-guided proximo-medial approach for injecting the carpal sheath is an accurate and technically straightforward technique. This approach should be considered for synoviocentesis of the carpal sheath, particularly in horses with no evident effusion.
Copyright © 2024. Published by Elsevier Inc.
Publication Date: 2024-12-20 PubMed ID: 39710350DOI: 10.1016/j.jevs.2024.105258Google Scholar: Lookup
The Equine Research Bank provides access to a large database of publicly available scientific literature. Inclusion in the Research Bank does not imply endorsement of study methods or findings by Mad Barn.
- Journal Article
Summary
This research summary has been generated with artificial intelligence and may contain errors and omissions. Refer to the original study to confirm details provided. Submit correction.
The research article explores a new ultrasound-guided approach for injecting the carpal flexor tendon sheath in horses and compares its effectiveness with an existing ‘blind’ approach. The study demonstrated that the new technique was more accurate and completely successful.
Study Design and Methods
- The researchers designed a prospective case-control study aimed at implementing and testing a new ultrasound-guided proximo-medial approach for injecting the carpal flexor tendon sheath in horses.
- This new technique was initially developed on ten cadaveric horse limbs using an undiluted ionic iodinated contrast medium. This helped the researchers to identify landmarks and establish an access point for injection.
- After developing the technique, it was validated on ten live horses. The efficacy of this new method was then compared with the conventional proximo-lateral ‘blind’ technique commonly used for these injections.
Comparison of Techniques and Findings
- Several factors were evaluated for each injection, including successful injection (contrast within the carpal canal), number of attempts made, and whether a structure other than the carpal sheath was penetrated during the injection.
- The conventional blind technique had an accuracy rate of 70%, with inadvertent injections into other structures. Failed or misplaced injections often resulted in contrast medium entering the dorso-palmar pouch of the radiocarpal joint, surrounding soft tissue of the carpal canal, or even intravenous injection.
- On the other hand, the new ultrasound-guided approach demonstrated a 100% accuracy rate for intrasynovial administration of the contrast medium.
Conclusions
- The study concluded that the ultrasound-guided proximo-medial approach for injecting the carpal flexor tendon sheath in horses is more accurate and technically straightforward than the conventional method.
- Due to its high success rate and greater accuracy, the study recommends the use of this method, particularly in cases where the horses do not show evident effusion.
Cite This Article
APA
Dörner CA, Vargas V, Castellón CH.
(2024).
Development of an ultrasound-guided proximo-medial approach for injection of the carpal flexor tendon sheath in horses and comparison with the conventional proximo-lateral ´blind` technique.
J Equine Vet Sci, 105258.
https://doi.org/10.1016/j.jevs.2024.105258 Publication
Researcher Affiliations
- Escuela de Medicina Veterinaria, Sede Viña del Mar, Facultad de Ciencias de la Vida, Universidad Andrés Bello, Quillota 980, Viña del Mar. Chile; Equestria Centro Médico Equino, Región de Valparaíso, Quillota 2260000. Chile. Electronic address: cdorner@gmail.com.
- Equestria Centro Médico Equino, Región de Valparaíso, Quillota 2260000. Chile.
- Equestria Centro Médico Equino, Región de Valparaíso, Quillota 2260000. Chile.
Conflict of Interest Statement
Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper
Citations
This article has been cited 0 times.Use Nutrition Calculator
Check if your horse's diet meets their nutrition requirements with our easy-to-use tool Check your horse's diet with our easy-to-use tool
Talk to a Nutritionist
Discuss your horse's feeding plan with our experts over a free phone consultation Discuss your horse's diet over a phone consultation
Submit Diet Evaluation
Get a customized feeding plan for your horse formulated by our equine nutritionists Get a custom feeding plan formulated by our nutritionists