Analyze Diet
American journal of veterinary research2021; 82(10); 818-822; doi: 10.2460/ajvr.82.10.818

Effect of thermodilution injectate volume and temperature on the accuracy and precision of cardiac output measurements for healthy anesthetized horses.

Abstract: To compare the accuracy and precision of cardiac output (CO) measurements derived from 4 thermodilution protocols that used different injectate temperatures and volumes in healthy adult horses. Methods: 8 healthy adult horses. Methods: Horses were anesthetized and instrumented with Swan-Ganz catheters. The CO was derived from each of 4 thermodilution protocols (IV injection of physiologic saline [0.9% NaCl] solution chilled to < 5 °C at volumes of 1 mL/15 kg of body weight [protocol A; control], 1 mL/25 kg [protocol B], and 1 mL/35 kg [protocol C] or maintained at 17 °C at a volume of 1 mL/15 kg [protocol D]) 3 times during each of 5 measurement cycles, with a 30-minute interval between cycles. During each measurement cycle, protocol A was performed first, and protocols B, C, and D were performed in a randomized order. Mean CO and within-subject variance in CO were compared among the 4 protocols. Results: Mean CO did not differ significantly among the 4 protocols. The within-subject variance for CO measurements derived from protocols C and D, but not protocol B, was significantly greater than that for protocol A (control). Conclusions: Results suggested that, in healthy adult horses, decreasing the thermodilution injectate volume to 1 mL/25 kg from the recommended volume of 1 mL/15 kg did not adversely affect the accuracy or precision of CO measurements. However, use of smaller injectate volumes or use of injectate at approximately room temperature is not recommended owing to a clinically unacceptable increase in CO measurement variability.
Publication Date: 2021-09-24 PubMed ID: 34554871DOI: 10.2460/ajvr.82.10.818Google Scholar: Lookup
The Equine Research Bank provides access to a large database of publicly available scientific literature. Inclusion in the Research Bank does not imply endorsement of study methods or findings by Mad Barn.
  • Journal Article

Summary

This research summary has been generated with artificial intelligence and may contain errors and omissions. Refer to the original study to confirm details provided. Submit correction.

The research examines the effect of injectate temperature and volume on the accuracy of cardiac output (CO) measurements in healthy adult horses, using four thermodilution protocols. The study finds that smaller injectate volumes or injectate at room temperature resulted in a significant change in the variance of CO measurements, suggesting these are not recommended owing to potential inaccuracies.

Experiment Overview

The procedure for measuring cardiac output (CO) in this study featured the following steps:

  • Eight healthy adult horses were anesthetized and fitted with Swan-Ganz catheters.
  • Four thermodilution protocols were used, varying in temperature and volume of the injectate. This injectate was a saline solution, and the varying temperatures and volumes were protocol A (control at 5° C, 1 mL/15 kg), protocol B (5° C, 1 mL/25 kg), protocol C (5° C, 1 mL/35 kg), and protocol D (17° C, 1 mL/15 kg).
  • Each protocol was performed three times during each of five measurement cycles, each separated by 30 minutes. Protocol A was always conducted first, while the others were done in random order.

Research Findings

The results of the experiment illuminated the following facts:

  • The mean CO did not differ significantly across the four different protocols.
  • The within-subject variance for CO measurements from protocols C and D was significantly larger than that from Protocol A (control). However, the injectate volume decrease to 1 mL/25 kg in Protocol B did not affect accuracy or precision in a negative way.

Conclusions

The concluding points from this study were:

  • In healthy adult horses, decreasing the volume of the thermodilution injectate from the recommended 1 mL/15 kg down to 1 mL/25 kg does not appear to negatively impact the accuracy or precision of CO measurements.
  • However, the use of smaller injectate volumes (as in protocol C) or the use of injectate maintained at approximately room temperature (as in Protocol D) resulted in greater variability in CO measurements and is not recommended because it may lead to less accurate results.

Cite This Article

APA
Jenny JCA, Hopster K, Hurcombe SD. (2021). Effect of thermodilution injectate volume and temperature on the accuracy and precision of cardiac output measurements for healthy anesthetized horses. Am J Vet Res, 82(10), 818-822. https://doi.org/10.2460/ajvr.82.10.818

Publication

ISSN: 1943-5681
NlmUniqueID: 0375011
Country: United States
Language: English
Volume: 82
Issue: 10
Pages: 818-822
PII: ajvr.82.10.818

Researcher Affiliations

Jenny, Jesse C A
    Hopster, Klaus
      Hurcombe, Samuel D

        MeSH Terms

        • Animals
        • Body Temperature
        • Cardiac Output
        • Horses
        • Temperature
        • Thermodilution / veterinary

        Citations

        This article has been cited 1 times.
        1. Gorenberg EB, Slack J, Stefanovski D, Theiss D, Hopster K. Dobutamine improves haemodynamics and oxygen delivery in standing and isoflurane-anaesthetised horses. Equine Vet J 2025 Nov;57(6):1677-1689.
          doi: 10.1111/evj.14488pubmed: 40052197google scholar: lookup