Abstract: Reliable point-of-care diagnostic tests are essential for diagnosing failure of transfer of passive immunity (FTPI) in foals. Quantitative lateral flow immunoassays (LFIAs) could reduce subjectivity but have not been well validated in foals. Objective: To validate the performance and diagnostic accuracy of a LFIA for quantifying immunoglobulin G (IgG) concentrations in foals, using radial immunodiffusion (RID) as the reference standard. Methods: Forty-two neonatal foals were sampled within 24 h of birth. Methods: This prospective exploratory diagnostic accuracy study evaluated the diagnostic accuracy of an LFIA for neonatal foal IgG measurement in accordance with the STARD guidelines. Blood samples were analyzed by LFIA, RID, and a SNAP-based ELISA. Primary analyses used serum samples. Diagnostic performance was evaluated for serum, plasma, and whole blood at predefined RID thresholds (<400 and ≤ 800 mg/dL) using receiver operating characteristic analysis, sensitivity, specificity, and Bland-Altman analysis. Results: Lateral flow immunoassays results were strongly correlated with RID (R2 = 0.91) within the analytical range (100-1000 mg/dL). The assay demonstrated good linearity, precision, and accuracy. Receiver operating characteristic analysis showed high point estimates for diagnostic performance across sample matrices, with AUCs ranging from 0.988 to 1.000, although estimates were imprecise because of the limited number of FTPI-positive foals. Conclusions: Lateral flow immunoassays demonstrated good agreement with RID for FTPI classification and could be suitable as a point-of-care screening tool, but is not interchangeable with RID for quantitative measurement. Although the limited number of FTPI-positive foals warrants cautious interpretation, these findings support LFIA as a screening tool for FTPI classification.
The Equine Research Bank provides access to a large database of publicly available scientific literature. Inclusion in the Research Bank does not imply endorsement of study methods or findings by Mad Barn.
This research summary has been generated with artificial intelligence and may contain errors and omissions. Refer to the original study to confirm details provided. Submit correction.
Overview
This study evaluated the accuracy and reliability of a lateral flow immunoassay (LFIA) for measuring immunoglobulin G (IgG) levels in newborn foals to detect failure of transfer of passive immunity (FTPI), comparing it to the standard radial immunodiffusion (RID) method.
The LFIA showed strong correlation with RID and demonstrated potential as a practical point-of-care screening tool for FTPI, though it is not a complete substitute for RID in precise quantitative measurements.
Background and Objective
Newborn foals receive IgG antibodies from their mothers through colostrum, providing essential early immune protection.
Failure of transfer of passive immunity (FTPI) happens when a foal does not acquire sufficient IgG, increasing the risk for infections and mortality.
Timely diagnosis of FTPI is critical for appropriate treatment and management.
Radial immunodiffusion (RID) is the reference standard for measuring IgG but is time-consuming and requires lab facilities.
Lateral flow immunoassays (LFIAs) offer rapid, point-of-care testing but have not been thoroughly validated for foals.
The study aimed to validate the diagnostic accuracy of a quantitative LFIA in measuring IgG concentrations in neonatal foals, benchmarked against RID.
Methods
Sample Population: Forty-two neonatal foals were sampled within 24 hours after birth.
Sample Types: Serum, plasma, and whole blood samples were collected for analysis.
Testing Methods:
LFIA for quantitative IgG measurement.
RID as the reference standard IgG measurement.
SNAP-based ELISA also performed for comparison.
Diagnostic Accuracy Evaluation:
Receiver Operating Characteristic (ROC) analysis to assess performance at clinically relevant RID threshold values (<400 mg/dL and ≤800 mg/dL), which define FTPI risk categories.
Correlations (R²) calculated between LFIA and RID results.
Bland-Altman analysis conducted to evaluate agreement and bias between methods.
Evaluation conformed with STARD (Standards for Reporting Diagnostic Accuracy Studies) guidelines.
Results
Correlation:
LFIA IgG results showed strong correlation with RID results within the analytical range (100-1000 mg/dL), with an R² of 0.91, indicating excellent agreement in quantification.
Linearity, Precision, and Accuracy:
The LFIA demonstrated good linearity across the measured range, ensuring consistent and reliable detection.
Precision tests showed repeatable results.
Accuracy was satisfactory when compared to RID.
Diagnostic Performance:
ROC analysis yielded very high Area Under the Curve (AUC) values ranging from 0.988 to 1.000 across serum, plasma, and whole blood matrices.
These values indicate excellent diagnostic ability to discriminate between foals with and without FTPI.
Sensitivity and specificity were high, although confidence intervals were wide due to a limited number of foals with confirmed FTPI.
Sample Matrices:
The LFIA performed well across different blood sample types, making it adaptable for practical clinical use.
Bland-Altman Analysis:
Showed good agreement with RID but suggested that LFIA should not replace RID when precise quantification is needed.
Conclusions and Implications
The quantitative LFIA offers a rapid, convenient, and reliable screening tool for identifying foals at risk of FTPI, which can facilitate early intervention.
Strong agreement with RID supports LFIA use in clinical settings for initial classification of passive immunity status.
LFIA is not interchangeable with RID for exact IgG quantification—RID remains necessary for detailed diagnostic confirmation.
Given the limited number of FTPI-positive foals in this study, further research is advised to confirm performance in larger and more diverse populations.
The LFIA’s ability to work with serum, plasma, and whole blood enhances its practical applicability in field or hospital environments.
Integration of this LFIA in veterinary practice could improve timely detection and management of FTPI, reducing disease risk and mortality in neonatal foals.
Cite This Article
APA
Sohn Y, An SJ, Oh HS, Kim J, Forbes E, Ryu SH.
(2026).
Evaluation of a lateral flow immunoassay for the quantitative measurement of immunoglobulin G in foals compared with radial immunodiffusion.
J Vet Intern Med, 40(5), aalag216.
https://doi.org/10.1093/jvimsj/aalag216
Veterinary Department, Korea Racing Authority, Gwacheon 13822, Republic of Korea.
An, Sung Jun
Department of Artificial Intelligence, Cheju Halla University, Jeju 63092, Republic of Korea.
Oh, Han Sang
R&D Center, BioNote, Inc, Hwaseong-si, Gyeonggi-do 18449, Republic of Korea.
Kim, Jungho
R&D Center, BioNote, Inc, Hwaseong-si, Gyeonggi-do 18449, Republic of Korea.
Forbes, Eliot
Racing Integrity Board, Greenlane, Private Bag 17902, Auckland 1546, New Zealand.
Ryu, Seung-Ho
Department of Equine Resources Science, Cheju Halla University, Jeju 63092, Republic of Korea.
MeSH Terms
Animals
Horses / immunology
Horses / blood
Immunodiffusion / veterinary
Immunodiffusion / methods
Immunoglobulin G / blood
Immunoassay / veterinary
Immunoassay / methods
Animals, Newborn / immunology
Sensitivity and Specificity
Immunity, Maternally-Acquired
Prospective Studies
Female
Rapid Diagnostic Tests
Conflict of Interest Statement
BioNote, Inc is the manufacturer of the Vcheck foal IgG test evaluated in this study. BioNote, Inc. performed laboratory testing but had no role in study design, data interpretation, statistical analysis, and manuscript preparation. The authors declare no other conflicts of interest.
References
This article includes 25 references
Arfuso F, Quartuccio M, Bazzano M, Fazio F, Piccione G. Erythrocyte osmotic fragility and selected hematologic variables in postparturient mares and their foals. Vet Clin Pathol 2016;45:260–270.
Rinnovati R, Butina BB, Lanci A, Mariella J. Diagnosis, treatment, surgical management, and outcome of septic arthritis of the tarsocrural joint in 16 foals. J Equine Vet Sci 2018;67:128–132.
Rohrbach BW, Buchanan BR, Drake JM. Use of a multivariable model to estimate the probability of discharge in hospitalized foals ≤ 7 days of age. J Am Vet Med Assoc 2006;228:1748–1756.
Giguère S, Weber EJ, Sanchez LC. Factors associated with outcome and gradual improvement in survival over time in equine neonates admitted to an intensive care unit. Equine Vet J 2017;49:45–50.
Davis R, Giguère S. Evaluation of five commercially available assays and measurement of serum total protein concentration via refractometry for diagnosis of failure of passive transfer of immunity in foals. J Am Vet Med Assoc 2005;227:1640–1645.
Tscheschlok L, Venner M, Howard J. Comparison of IgG concentrations by radial immunodiffusion, electrophoretic gamma globulin concentrations, and total globulins in neonatal foals. Equine Vet J 2017;49:149–154.
Valentin MA, Ma S, Zhao A, Legay F, Avrameas A. Validation of immunoassay for protein biomarkers: bioanalytical study plan implementation to support preclinical and clinical studies. J Pharm Biomed Anal 2011;55:869–877.
Wong DM, Giguère S, Wendel MA. Evaluation of a point-of-care portable analyzer for measurement of plasma IgG, total protein, and albumin in ill neonatal foals. J Am Vet Med Assoc 2013;242:812–819.
Wilkins PA, Dewan-Mix S. Efficacy of intravenous plasma to transfer passive immunity in equine neonates with failure of passive transfer. Cornell Vet 1994;84:7–14.