Measurement of cardiac output by transoesophageal Doppler echocardiography in anaesthetized horses: comparison with thermodilution.
Abstract: In order to determine if transoesophageal Doppler echocardiography could be used to estimate cardiac output in anaesthetized horses, we have compared the technique with estimations of cardiac output by thermodilution in eight healthy adult thoroughbreds. Measurements of aortic blood flow velocity were made by high pulse repetition frequency (HPRF) and continuous wave (CW) Doppler echocardiography from a 3.5-MHz transoesophageal probe. Cardiac output was increased during the study by administration of dobutamine, providing a range of cardiac output measurements by thermodilution from 15.0 to 64.4 liter min-1. Estimations derived from CW Doppler overestimated cardiac output compared with thermodilution (bias = 4.0 litre min-1). Estimations from HPRF Doppler echocardiography more closely reflected measurements obtained by thermodilution (bias = 0.7 litre min-1). Limits of agreement between the techniques were similar for both modes of insonation (HPRF = -7.7 to 9.1 litre min-1, CW = -4.9 to 12.8 litre min-1). There were significant differences in bias between both Doppler techniques and thermodilution for individual horses. As a result, for any individual horse, limits of agreement between the techniques were closer (HPRF = +/- 6.4 litre min-1, CW = +/- 7.6 litre min-1). We conclude that transoesophageal echocardiography provided an alternative, effective and non-invasive method for measurement of cardiac output in anaesthetized horses.
Publication Date: 1996-12-01 PubMed ID: 9014632DOI: 10.1093/bja/77.6.773Google Scholar: Lookup
The Equine Research Bank provides access to a large database of publicly available scientific literature. Inclusion in the Research Bank does not imply endorsement of study methods or findings by Mad Barn.
- Comparative Study
- Journal Article
- Research Support
- Non-U.S. Gov't
Summary
This research summary has been generated with artificial intelligence and may contain errors and omissions. Refer to the original study to confirm details provided. Submit correction.
This study researches the effectiveness of transoesophageal Doppler echocardiography as a non-invasive method for measuring cardiac output in anaesthetized horses, by comparing it to the commonly used thermodilution method.
Research Methodology
- The study was conducted on eight healthy adult thoroughbred horses that were anaesthetized.
- Cardiac output was measured using two methods: Transoesophageal Doppler Echocardiography and thermodilution.
- Within the echocardiography method, measurements of aortic blood flow velocity were made using two techniques: High Pulse Repetition Frequency (HPRF) and Continuous Wave (CW) Doppler echocardiography. These measurements were made using a 3.5-MHz transoesophageal probe.
- The cardiac output of the horses was increased during the study by administering dobutamine. This gave a range of cardiac output measurements by thermodilution from 15.0 to 64.4 liters per minute.
Research Findings
- Estimations of cardiac output derived from CW Doppler were found to overestimate cardiac output compared to thermodilution, by a bias of 4.0 liters per minute.
- Estimations from HPRF Doppler echocardiography more closely reflected measurements obtained by thermodilution, with a smaller bias of 0.7 liters per minute.
- The limits of agreement between the techniques (CW and HPRF) and thermodilution were similar for both modes, despite the different biases.
- Significant differences in the biases between both Doppler techniques and thermodilution were observed for individual horses. As such, when measured per individual horse, the limits of agreement between the techniques were narrower.
Conclusion
- From this study, it can be inferred that transoesophageal echocardiography, despite some differences, can provide an effective and non-invasive alternative for measuring cardiac output in anaesthetized horses.
Cite This Article
APA
Young LE, Blissitt KJ, Bartram DH, Clutton RE, Molony V, Jones RS.
(1996).
Measurement of cardiac output by transoesophageal Doppler echocardiography in anaesthetized horses: comparison with thermodilution.
Br J Anaesth, 77(6), 773-780.
https://doi.org/10.1093/bja/77.6.773 Publication
Researcher Affiliations
- Department of Veterinary Clinical Studies, Royal (Dick) School of Veterinary Studies, Midlothian.
MeSH Terms
- Anesthesia, General
- Animals
- Aorta / diagnostic imaging
- Cardiac Output
- Dobutamine
- Echocardiography, Transesophageal / methods
- Female
- Horses / physiology
- Male
- Monitoring, Physiologic / methods
- Thermodilution
Citations
This article has been cited 4 times.- Shaikh F, Kenny JE, Awan O, Markovic D, Friedman O, He T, Singh S, Yan P, Qadir N, Barjaktarevic I. Measuring the accuracy of cardiac output using POCUS: the introduction of artificial intelligence into routine care. Ultrasound J 2022 Dec 14;14(1):47.
- Schubert S, Schmitz T, Weiss M, Nagdyman N, Huebler M, Alexi-Meskishvili V, Berger F, Stiller B. Continuous, non-invasive techniques to determine cardiac output in children after cardiac surgery: evaluation of transesophageal Doppler and electric velocimetry. J Clin Monit Comput 2008 Aug;22(4):299-307.
- Critchley LA, Critchley JA. A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques. J Clin Monit Comput 1999 Feb;15(2):85-91.
- Vernemmen I, Demeyere M, Van Steenkiste G, Buschmann E, Decloedt A, van Loon G. Novel Intracardiac Ultrasound Images Developed on a Cardiac Ultrasound Simulator and Validated in Live Horses. J Vet Intern Med 2025 May-Jun;39(3):e70087.
Use Nutrition Calculator
Check if your horse's diet meets their nutrition requirements with our easy-to-use tool Check your horse's diet with our easy-to-use tool
Talk to a Nutritionist
Discuss your horse's feeding plan with our experts over a free phone consultation Discuss your horse's diet over a phone consultation
Submit Diet Evaluation
Get a customized feeding plan for your horse formulated by our equine nutritionists Get a custom feeding plan formulated by our nutritionists