Analyze Diet

Food additives & contaminants. Part A, Chemistry, analysis, control, exposure & risk assessment.

Periodical
Nutritional Sciences
Food Additives
Food Contamination
Publisher:
Taylor & Francis,. London : Informa Healthcare
Frequency: Monthly
Country: England
Language: English
Author(s):
International Society for Mycotoxicology.
Start Year:2008 -
ISSN:
1944-0049 (Print)
1944-0057 (Electronic)
1944-0057 (Linking)
Impact Factor
2.9
2022
NLM ID:101485040
(OCoLC):248654301
LCCN:2008229352
Classification:W1 FO402
Development of an immunochromatographic assay for the β-adrenergic agonist feed additive zilpaterol.
Food additives & contaminants. Part A, Chemistry, analysis, control, exposure & risk assessment    June 6, 2018   Volume 35, Issue 8 1519-1529 doi: 10.1080/19440049.2018.1463568
Shelver WL, Smith DJ.Zilpaterol is a β-adrenergic agonist feed additive approved in the United States to increase weight gain and improve feed efficiency of cattle. A zilpaterol immunochromatographic assay was developed as an economical and user-friendly rapid detection method for zilpaterol and validated using urine and tissue samples derived from animal studies. The assay sensitivity was 1.7-23.2 ng g or mL across a variety of feed and animal matrices and did not cross-react with clenbuterol or ractopamine. No sample pre-treatment of cattle and sheep urine was needed, but horse urine and feed required dilution;...
Validation of a method for sedatives and β-blockers determination in swine, bovine and equine kidney using liquid chromatography coupled with tandem mass spectrometry.
Food additives & contaminants. Part A, Chemistry, analysis, control, exposure & risk assessment    November 21, 2016   Volume 34, Issue 1 32-39 doi: 10.1080/19440049.2016.1252468
de Oliveira LG, Barreto F, Hoff R, Rübensam G, Scherer Kurz MH, Galle G, Gonçalves FF.A method for the determination of five sedatives and 14 β-blocker residues in swine, bovine and equine kidney was validated. Samples were extracted with acetonitrile and purified using dispersive solid phase extraction (d-SPE) with Celite 545 with subsequent analysis by LC-MS/MS. A simplified protocol was applied to validate the method scope extension to include new matrices. Parameters such as recovery, trueness, linearity (r), relative standard deviation (RSD), decision limit (CCα) and method capability (CCβ) were measured for the bovine and equine kidney matrices. The method was applied ...
Pyrrolizidine alkaloids in food and feed on the Belgian market.
Food additives & contaminants. Part A, Chemistry, analysis, control, exposure & risk assessment    October 15, 2015   Volume 32, Issue 11 1939-1951 doi: 10.1080/19440049.2015.1086821
Huybrechts B, Callebaut A.Pyrrolizidine alkaloids (PAs) are widely distributed plant toxins with species dependent hepatotoxic, carcinogenic, genotoxic and pneumotoxic risks. In a recent European Food Safety Authority (EFSA) opinion, only two data sets from one European country were received for honey, while one feed data set was included. No data are available for food or feed samples from the Belgian market. We developed an LC-MS/MS method, which allowed the detection and quantification of 16 PAs in a broad range of matrices in the sub ng g(-1) range. The method was validated in milk, honey and hay and applied to hon...
Development and validation of a method for Cd, Pb and As analysis in bovine, equine and poultry liver by inductively coupled plasma mass spectrometry.
Food additives & contaminants. Part A, Chemistry, analysis, control, exposure & risk assessment    October 14, 2011   Volume 29, Issue 4 609-616 doi: 10.1080/19440049.2011.608381
Lara PC, Fabrino HJ, Germano A, Silva JB.A method for the determination of As, Cd and Pb in bovine, equine and poultry liver by ICP-MS was developed and validated. Samples were digested in a microwave oven using a 10% HNO(3) solution. A set of experiments was made according to a central composite design (CCD) for optimisation of the plasma argon flow, nebuliser argon flow and radiofrequency power applied to the plasma. During the validation, Rh and Ru were evaluated as internal standards and, after validation, the best was Rh for Pb and Cd analysis, but for As better results were obtained without an internal standard. The method allo...