Biocompatibility in horses refers to the compatibility of materials or substances with equine tissues and physiological processes. This concept is particularly relevant in the context of veterinary medical devices, implants, and pharmaceuticals used in equine care. Biocompatibility assessments are conducted to ensure that these materials do not provoke adverse reactions, such as inflammation, toxicity, or rejection when introduced into the horse's body. These evaluations involve a range of in vitro and in vivo tests to analyze interactions at the cellular and systemic levels. This page compiles peer-reviewed research studies and scholarly articles that explore the methodologies, findings, and implications of biocompatibility assessments in equine health management.
Collier MA, Brighton CT, Norrdin R, Twardock AR, Rendano VT.The effect of a 20-microA direct-current implantable bone growth stimulator (BGS) on bone production with a "gap healing" model in the horse was evaluated. The right and left 4th metatarsal bones (Mt-4) were used in 7 adult horses to create the "gap healing" model. A 4-mm section of the Mt-4 bone was resected bilaterally in each horse. The BGS was surgically placed into the 7 left Mt-4 defects. The 7 right Mt-4 defects served as controls. Six horses survived the 16-week experimental period. Signs of pain, decreased range of limb motion, or lameness was not observed in any animal during the 16 ...
Collier MA, Lowe JE, Rendano VT.Materials fatigue and gross biocompatability of an implantable bone growth stimulator (BGS) were assessed in a 6-month trial using 6 ponies. The forelegs of each pony were implanted with a BGS; the right leg implant had the cathode and cathode lead preconnected by the manufacturer, and the left leg implant was connected at surgery. Evaluation was by radiographic and clinical examination at the beginning and end of the experimental period. Six of the 12 cathode leads (50%) and 7 of the 12 cathodes (58%) were broken at 6 months. All of the implanted preconnected cathode and insulated cathode lea...
Goodship AE, Brown PN, Yeats JJ, Jenkins DH, Silver IA.The results of an assessment of carbon fibre for biological use are given, with particular reference to the clinical use of the material in the treatment of equine tendon injury. Biocompatability of the fibres is assessed using fibroblast cell cultures and replacement of normal tendon with carbon fibre prostheses in experimental animals. The rationale and technique for using this material in clinical cases of tendon injury in the racehorse are described. Results are given from 62 implant operations in a limited series of 40 horses.
Mader Ch, Geisel O, Gerhards H, Hermanns W.In the present work transponders of 2 identification systems have been implanted on an exactly defined site at the bottom of the ear on 28 horses. The Backhome system is easier to handle and less complicated than the trovan system since it is smaller and handier. The hemorrhages that had occurred after the injection were mild at 17 animals and moderate at 4 animals. Inflame changes at the injection site post application were limited to minor swellings (n = 3) and minor pain (n = 6). The interrogator's scope of the two transponder systems is different. The interrogator's scope of the trovan tra...
Collier MA, Lowe JE, Rendano VT.Materials fatigue and gross biocompatability of an implantable bone growth stimulator (BGS) were assessed in a 6-month trial using 6 ponies. The forelegs of each pony were implanted with a BGS; the right leg implant had the cathode and cathode lead preconnected by the manufacturer, and the left leg implant was connected at surgery. Evaluation was by radiographic and clinical examination at the beginning and end of the experimental period. Six of the 12 cathode leads (50%) and 7 of the 12 cathodes (58%) were broken at 6 months. All of the implanted preconnected cathode and insulated cathode lea...
Ringeisen H, Pöschke A, Krähling B, Schröck C, Stoll M, Vogelsberg J, Failing K, Staszyk C.Therapy for equine periodontal disease can include filling of the periodontal pockets and widened interproximal spaces. Recommended dental materials are generally adopted from human dentistry. Objective: To evaluate the biocompatibility of dental materials for equine periodontal fillings in vitro. Methods: In vitro experiments. Methods: Four different dental materials (PeriCare , Provicol , Calxyl and Honigum) were tested on equine periodontal fibroblasts. Possible cytotoxic effects were assessed microscopically and by MTT assay, and the expression of inflammatory marker genes was measured by...