Implants in horses refer to medical devices or materials that are surgically placed into the horse's body for therapeutic or diagnostic purposes. These implants can include orthopedic devices such as screws, plates, or pins used to stabilize fractures, as well as other devices designed to deliver medication or monitor physiological parameters. The use of implants in equine medicine is an area of ongoing research, focusing on materials' biocompatibility, the long-term effects on equine health, and the improvement of surgical techniques. This page compiles peer-reviewed research studies and scholarly articles that explore the application, development, and outcomes associated with the use of implants in horses.
Peterson PR, Pascoe JR, Wheat JD.Fractures of Metacarpal and Metatarsal II and IV (the splint bones) were treated in 283 horses over an 11 year period. In 21 cases the proximal portion of the fractured bone was stabilized with metallic implants. One or more cortical bone screws were used in 11 horses, and bone plates were applied in 11 horses. One horse received both treatments. Complications of screw fixation included bone failure, implant failure, radiographic lucency around the screws, and proliferative new bone at the ostectomy site. Only two of the horses treated with screw fixation returned to their intended use. Compli...
Cheal EJ, Snyder BD, Nunamaker DM, Hayes WC.The objective of this investigation was to examine the stress-morphology relationships for trabecular bone around implants with different surface characteristics. Stainless steel spheres with either a polished surface or a sintered-bead porous coating were implanted unilaterally into equine patellae and maintained for a 6 month period. Stereological methods were used to quantify the trabecular bone morphology and finite element analyses were performed to predict the trabecular bone stresses. In general, the remodeling response around the smooth implants was greater than that around those porou...
Collier MA, Lowe JE, Rendano VT.Materials fatigue and gross biocompatability of an implantable bone growth stimulator (BGS) were assessed in a 6-month trial using 6 ponies. The forelegs of each pony were implanted with a BGS; the right leg implant had the cathode and cathode lead preconnected by the manufacturer, and the left leg implant was connected at surgery. Evaluation was by radiographic and clinical examination at the beginning and end of the experimental period. Six of the 12 cathode leads (50%) and 7 of the 12 cathodes (58%) were broken at 6 months. All of the implanted preconnected cathode and insulated cathode lea...
DeBowes RM, Grant BD, Bagby GW, Gallina AM, Sande RD, Ratzlaff MH.A modified form of the Cloward technique for anterior cervical fusion in human beings was used in the application of different grafts for evaluation of their effectiveness in stabilizing equine cervical vertebrae. Results of bovine xenograft implants in 8 horses were compared with results of stainless steel baskets (SSB) packed with cancellous autogenous bone in 8 horses. Graft material was incorporated in all cases. Evidence of graft rejection was not present. Both forms of implants decreased the mobility of the intervertebral space in which they were implanted. A fibrous connective tissue un...
Goodship AE, Brown PN, Yeats JJ, Jenkins DH, Silver IA.The results of an assessment of carbon fibre for biological use are given, with particular reference to the clinical use of the material in the treatment of equine tendon injury. Biocompatability of the fibres is assessed using fibroblast cell cultures and replacement of normal tendon with carbon fibre prostheses in experimental animals. The rationale and technique for using this material in clinical cases of tendon injury in the racehorse are described. Results are given from 62 implant operations in a limited series of 40 horses.
Mattison DR, White NB, Nightingale MR.The polycyclic aromatic hydrocarbon (PAH) benzo(a)pyrene (BP) reduced the fertility of DBA/2N mice in a dose-dependent fashion. Control mice produced offspring at a rate of 0.91 pups/mouse per week. Treatment with BP at doses of 10, 100, 200, and 500 mg/kg decreased offspring production rates to 0.61, 0.20, zero and zero pups/mouse per week, respectively. BP also destroyed primordial oocytes in similarly treated mice. Treatment with BP at doses of 10, 50, 100, and 500 mg/kg destroyed 20%, 58%, 88%, and 100%, respectively, of the primordial oocytes in DBA/2N mouse ovaries. Dose-response curves ...
Norrie RD.The concept of regenerative healing has been used to manipulate the healing process in experimental animals and clinically to augment bone healing in people after orthopedic operation. An implanted electrical device was used in an attempt to produce regenerative healing in experimentally created equine tendon injury. The bimetallic electrical implant did not produce regenerative healing under the conditions of this experiment. The mechanism of implantation and discussion of the results are included.
Mader Ch, Geisel O, Gerhards H, Hermanns W.In the present work transponders of 2 identification systems have been implanted on an exactly defined site at the bottom of the ear on 28 horses. The Backhome system is easier to handle and less complicated than the trovan system since it is smaller and handier. The hemorrhages that had occurred after the injection were mild at 17 animals and moderate at 4 animals. Inflame changes at the injection site post application were limited to minor swellings (n = 3) and minor pain (n = 6). The interrogator's scope of the two transponder systems is different. The interrogator's scope of the trovan tra...
Nevins M, Cappetta EG, Cullum D, Khang W, Misch C, Ricchetti P, Sclar A, Wallace SS, Ho DK, Kim DM.Conventional dentoalveolar osseous augmentation procedures for creating bone volume for dental implant placement often involve the use of grafting materials with or without barrier membranes to foster selective cell and tissue repopulation. A study was conducted to determine the efficacy of equine particulate bone (Equimatrix, Osteohealth) to augment the creation of new bone and preserve the volume of bone at extraction sites for the purpose of placing an implant in an optimal position for restoration. Clinical and histologic evidence supported the suitability of equine particulate bone for ex...
Collier MA, Lowe JE, Rendano VT.Materials fatigue and gross biocompatability of an implantable bone growth stimulator (BGS) were assessed in a 6-month trial using 6 ponies. The forelegs of each pony were implanted with a BGS; the right leg implant had the cathode and cathode lead preconnected by the manufacturer, and the left leg implant was connected at surgery. Evaluation was by radiographic and clinical examination at the beginning and end of the experimental period. Six of the 12 cathode leads (50%) and 7 of the 12 cathodes (58%) were broken at 6 months. All of the implanted preconnected cathode and insulated cathode lea...
Archer RM, Schneider RK, Lindsay WA, Wilson JW.Perforated stainless steel cylinders filled with autogenous cancellous bone were implanted in the distal tarsal joints of four horses. Graft cell survival was poor two weeks after surgery in one horse. In two horses, at 10 months there was partial arthrodesis of the joints with incorporation of the implants into the osseous union. The implants were filled with vascularised woven bone. These two horses were sound nine months after surgery. One horse fractured its third tarsal bone and was still positive to a hock flexion test 12 months after surgery.
Geisert RD.Establishment and maintenance of pregnancy in a number of mammalian species depends upon a tightly regulated interaction between the semiallogeneic conceptus and the maternal uterine endometrium.The term "Maternal Recognition of Pregnancy" is attributed to Roger V. Short's paper titled "Implantation and the Maternal Recognition of Pregnancy" which was published in proceedings from the 1969 Symposium on Foetal Autonomy.Professor Short's landmark paper stimulated increased interest in elucidating how the conceptus signals its presence to assure maintenance of the corpus luteum beyond the normal ...
Vidović A, Jansen D.The first part of this case report describes the surgical treatment of a unilateral mandibular fracture in the standing horse by using a fixateur type I. By the time of implant removal, the fracture had completely healed. However, during implant removal, an implant failure of 2 of the 4 implants occurred with fragments remaining in the bone. The second part of the report focuses on the development of a special surgical instrument that was designed for removal of the implant fragments. Furthermore, the surgical method allowing the entire extirpation of the fragments within a second surgery is d...
Sjöberg I, Law E, Södersten F, Höglund OV, Wattle O.A 3D printed self-locking device made of polydioxanone (PDO) was developed to facilitate a standardized ligation technique. The subcutaneous tissue reaction to the device was evaluated after implantation in ten horses of mixed age, sex and breed and compared to loops of poly(lactic-co-glycolic acid) (PLGA). In two of the horses, the implants were removed before closing the skin. The appearance of the implants and surrounding tissue was followed over time using ultrasonography. Implants were removed after 10 and 27 (± 1) days for histologic examination. Results: On macroscopic inspection at ...