Refractometry in horses involves the use of refractometers to measure the refractive index of fluids, primarily for assessing hydration status and protein concentration. This technique is commonly applied to equine blood plasma or serum, where it helps estimate total protein levels, and to urine, where it aids in evaluating specific gravity. Refractometers provide a rapid and non-invasive method for obtaining valuable diagnostic information. The measurements obtained can assist veterinarians in monitoring health conditions, diagnosing dehydration, and assessing nutritional status. This page compiles peer-reviewed research studies and scholarly articles that explore the application, accuracy, and clinical relevance of refractometry in equine veterinary practice.
Turini L, Francesca B, Matilde V, Francesca B, Valentina M, Micaela S.While the passive transfer of immunity in horse and donkey foals has been extensively studied, there is limited information for mule foals. Immunoglobulin type G (IgG) and serum total protein concentration (TP) were assessed at different sampling times to evaluate the correlation between serum radial immunodiffusion (SRID) with electrophoresis, refractometry, and dry chemistry analyzer (Biuret), and to estimate serum IgG concentrations using serum TP in mule foals. We analyzed a total of 30 samples collected at birth, and at 6, 12, 24, and 48 h of life from 6 mule foals by SRID, electrophores...
de-Lima TC, de-Sobral GG, de-França Queiroz AES, Chinelate GCB, Porto TS, Oliveira JTC, Carneiro GF.Foals require maternal colostrum in the first hours of life to prevent failure of transfer of passive immunity (FTIP). Innovative storage methods such as lyophilization may enable conservation of colostrum immunoglobulins by a differentiated process of dehydration. The current study aimed to compare the quality of equine colostrum after freezing and after the lyophilization process. Thirty-one pregnant Quarter Horse mares were used. The IgG concentration of frozen and lyophilized colostrum was determined by simple radial immunodiffusion (SRID) and Brix refractometry. The physical-chemical comp...
Akköse M, Karabulut E, Yılmaz İÇ, Dik Ç, İnal Ş, Özbeyaz C, Çam M, Çınar EM, Orakçı D, Durmaz M.The objective of this cross-sectional study was to determine the accuracy of the digital Brix and serum total protein (TP) refractometers for estimating different passive immunity status in neonatal foals. In total, 18- to 40-h old purebred Arabian foals (n = 185) were used. Serum TP concentrations, total solid percentages and IgG concentrations were measured with a digital serum TP refractometer, digital Brix refractometer and the gold standard radial immunodiffusion (RID) assay, respectively. Correlation coefficients were calculated between the refractometer and RID assay results. A receiv...
Beckwith-Cohen B, Elad D, Bdolah-Abram T, Ofri R.To determine baseline tear pH in dogs, horses, and cattle by use of a microelectrode. Methods: 28 dogs, 24 horses, and 29 cattle. Methods: Under manual restraint, tears were collected from each subject's left eye with cotton spears. A Schirmer tear test was performed in the right eye. Tears were extracted from the spears by centrifugation. Tear volume was measured, pH was determined with a microelectrode, and total solids (TS) concentration was measured by refractometry. Results: Mean ± SD pH of tears in cattle, dogs, and horses was 8.32 ± 0.14, 8.05 ± 0.26, and 7.84 ± 0.30, respectively. ...
Korosue K, Murase H, Sato F, Ishimaru M, Kotoyori Y, Nambo Y.The object of this study was to evaluate the usefulness of measuring the differences in the values of the serum total protein (DVSTP) concentration of foals and the refractometry index (DVRI) of the milk of dams before and after nursing of the colostrum for assessing failure of passive transfer (FPT) in foals. Serum samples from 31 foals were collected before the first nursing and other 1 to 6 times between 4 and 24 hr after birth. Paired colostrum and milk samples were collected from 14 of their dams at the same time. Serum samples were analyzed for IgG concentration using a single radial imm...
Venner M, Markus RG, Strutzberg-Minder K, Nogai K, Beyerbach M, Klug E.In 360 samples of colostrum and 36 samples of blood of warmblood mares, the concentration of immunoglobulin G (IgG) was evaluated in the post partal period with an ELISA and the results were compared to values obtained with 2 field methods--refractometry and colostrometry. A significant correlation (p < 0.0001) was determined between ELISA and colostrometry (r = +0.88) and between ELISA and refractometry (r = +0.93). So both field-methods seem suitable for evaluation of the colostral IgG-concentration in mares. Further the kinetic of the IgG concentration in colostrum, the volume of colostr...
Estepa JC, Lopez I, Mayer-Valor R, Rodriguez M, Aguilera-Tejero E.The aim of this study was to evaluate the influence of two commonly used anticoagulants (K3EDTA and lithium heparin) on refractometric and spectrophotometric measurement of total protein (TP) concentration in equine peritoneal fluid samples. The influence of a commercial solution of K3EDTA, a solution of K3EDTA in distilled water and lithium heparin on the refractometric and spectrophotometric (biuret) quantification of TP content in peritoneal fluid samples was assessed. Total protein concentration measured by refractometry was consistently overestimated in samples with commercial K3EDTA. The...
George JW, O'Neill SL.Most hand-held medical refractometers have internal scales that limit protein measurement to results >/=2.5 g/dL. Tables for conversion of refraction (r) to protein concentration for values as low as 0.1 g/dL were published in the 1960s, but their accuracy for use on body fluids has not been established. The purpose of this study was to assess the reliability of body cavity fluid protein determination by refractometry. We compared the protein concentration of 25 body cavity fluids as determined by 2 Goldberg type hand-held refractometers with results obtained by the biuret method. Published...
Beckwith-Cohen B, Elad D, Bdolah-Abram T, Ofri R.To determine baseline tear pH in dogs, horses, and cattle by use of a microelectrode. Methods: 28 dogs, 24 horses, and 29 cattle. Methods: Under manual restraint, tears were collected from each subject's left eye with cotton spears. A Schirmer tear test was performed in the right eye. Tears were extracted from the spears by centrifugation. Tear volume was measured, pH was determined with a microelectrode, and total solids (TS) concentration was measured by refractometry. Results: Mean ± SD pH of tears in cattle, dogs, and horses was 8.32 ± 0.14, 8.05 ± 0.26, and 7.84 ± 0.30, respectively. ...
Venner M, Markus RG, Strutzberg-Minder K, Nogai K, Beyerbach M, Klug E.In 360 samples of colostrum and 36 samples of blood of warmblood mares, the concentration of immunoglobulin G (IgG) was evaluated in the post partal period with an ELISA and the results were compared to values obtained with 2 field methods--refractometry and colostrometry. A significant correlation (p < 0.0001) was determined between ELISA and colostrometry (r = +0.88) and between ELISA and refractometry (r = +0.93). So both field-methods seem suitable for evaluation of the colostral IgG-concentration in mares. Further the kinetic of the IgG concentration in colostrum, the volume of colostr...
Korosue K, Murase H, Sato F, Ishimaru M, Kotoyori Y, Nambo Y.The object of this study was to evaluate the usefulness of measuring the differences in the values of the serum total protein (DVSTP) concentration of foals and the refractometry index (DVRI) of the milk of dams before and after nursing of the colostrum for assessing failure of passive transfer (FPT) in foals. Serum samples from 31 foals were collected before the first nursing and other 1 to 6 times between 4 and 24 hr after birth. Paired colostrum and milk samples were collected from 14 of their dams at the same time. Serum samples were analyzed for IgG concentration using a single radial imm...
George JW, O'Neill SL.Most hand-held medical refractometers have internal scales that limit protein measurement to results >/=2.5 g/dL. Tables for conversion of refraction (r) to protein concentration for values as low as 0.1 g/dL were published in the 1960s, but their accuracy for use on body fluids has not been established. The purpose of this study was to assess the reliability of body cavity fluid protein determination by refractometry. We compared the protein concentration of 25 body cavity fluids as determined by 2 Goldberg type hand-held refractometers with results obtained by the biuret method. Published...
Estepa JC, Lopez I, Mayer-Valor R, Rodriguez M, Aguilera-Tejero E.The aim of this study was to evaluate the influence of two commonly used anticoagulants (K3EDTA and lithium heparin) on refractometric and spectrophotometric measurement of total protein (TP) concentration in equine peritoneal fluid samples. The influence of a commercial solution of K3EDTA, a solution of K3EDTA in distilled water and lithium heparin on the refractometric and spectrophotometric (biuret) quantification of TP content in peritoneal fluid samples was assessed. Total protein concentration measured by refractometry was consistently overestimated in samples with commercial K3EDTA. The...
Akköse M, Karabulut E, Yılmaz İÇ, Dik Ç, İnal Ş, Özbeyaz C, Çam M, Çınar EM, Orakçı D, Durmaz M.The objective of this cross-sectional study was to determine the accuracy of the digital Brix and serum total protein (TP) refractometers for estimating different passive immunity status in neonatal foals. In total, 18- to 40-h old purebred Arabian foals (n = 185) were used. Serum TP concentrations, total solid percentages and IgG concentrations were measured with a digital serum TP refractometer, digital Brix refractometer and the gold standard radial immunodiffusion (RID) assay, respectively. Correlation coefficients were calculated between the refractometer and RID assay results. A receiv...
de-Lima TC, de-Sobral GG, de-França Queiroz AES, Chinelate GCB, Porto TS, Oliveira JTC, Carneiro GF.Foals require maternal colostrum in the first hours of life to prevent failure of transfer of passive immunity (FTIP). Innovative storage methods such as lyophilization may enable conservation of colostrum immunoglobulins by a differentiated process of dehydration. The current study aimed to compare the quality of equine colostrum after freezing and after the lyophilization process. Thirty-one pregnant Quarter Horse mares were used. The IgG concentration of frozen and lyophilized colostrum was determined by simple radial immunodiffusion (SRID) and Brix refractometry. The physical-chemical comp...
Turini L, Francesca B, Matilde V, Francesca B, Valentina M, Micaela S.While the passive transfer of immunity in horse and donkey foals has been extensively studied, there is limited information for mule foals. Immunoglobulin type G (IgG) and serum total protein concentration (TP) were assessed at different sampling times to evaluate the correlation between serum radial immunodiffusion (SRID) with electrophoresis, refractometry, and dry chemistry analyzer (Biuret), and to estimate serum IgG concentrations using serum TP in mule foals. We analyzed a total of 30 samples collected at birth, and at 6, 12, 24, and 48 h of life from 6 mule foals by SRID, electrophores...