Defining the specificity of recombinant human erythropoietin confirmation in equine samples by liquid chromatography-tandem mass spectrometry.
Abstract: The proteotypic human EPO peptides YLLEAK (T4), SLTTLLR (T11), TITADTFR (T14), and VYSNFLR (T17) are often used to confirm the presence of recombinant human EPO (rhEPO) in equine samples. Each of these peptides contains one or more isomeric leucine or isoleucine amino acids, raising the possibility that a simple leucine/isoleucine substitution could lead to a false identification when compared with a rhEPO reference standard. To examine this possibility variants of these four peptides were analysed by liquid chromatography-tandem mass spectrometry (LC-MS/MS). These studies indicate that confirmation of rhEPO in equine samples by immuno-affinity capture and LC-MS/MS analysis is true and accurate. It was also found that chromatography played a greater role in determining LC-MS/MS specificity than tandem mass spectrometry and that, in the case of more hydrophilic peptides, the accuracy of peptide identification could be enhanced by the inclusion of C and N labelled peptide internal standards.
© 2021 John Wiley & Sons, Ltd.
Publication Date: 2021-12-21 PubMed ID: 34898016DOI: 10.1002/dta.3210Google Scholar: Lookup The Equine Research Bank provides access to a large database of publicly available scientific literature. Inclusion in the Research Bank does not imply endorsement of study methods or findings by Mad Barn.
- Journal Article
Summary
This research summary has been generated with artificial intelligence and may contain errors and omissions. Refer to the original study to confirm details provided. Submit correction.
This study researched the accuracy of using certain peptides to detect the presence of recombinant human EPO (rhEPO) in horse samples, through a process known as liquid chromatography-tandem mass spectrometry. It found that the method is accurate, and that chromatography has more influence on accuracy than the mass spectrometry aspect of the process.
Peptides used for Identification
- The research is based on the recognition of recombinant human erythropoietin (rhEPO), a hormone that controls red blood cell production, in equine samples using four proteotypic human EPO peptides – YLLEAK (T4), SLTTLLR (T11), TITADTFR (T14), and VYSNFLR (T17).
- These particular peptides are often used to confirm the presence of rhEPO in samples, but there is concern that they may give false positives due to isomeric leucine or isoleucine amino acids they contain. This means there is a possibility of mistakenly identifying a substance as rhEPO if there is a simple substitution of the leucine/isoleucine amino acids.
Analysis by Liquid Chromatography-Tandem Mass Spectrometry
- To test the accuracy of the identification process, the researchers analysed variations of these four peptides using liquid chromatography-tandem mass spectrometry (LC-MS/MS), a technique commonly used to separate, identify and quantify each component in a mixture.
- The researchers established that the identification of rhEPO in equine samples through the combination of immuno-affinity capture and LC-MS/MS analysis is both true and accurate, thereby validating the use of these peptides for rhEPO detection.
Role of Chromatography and Tandem Mass Spectrometry
- Furthermore, they found that chromatography, the part of the process where separation of the mixture occurs, has a greater influence on the specificity of LC-MS/MS detection than the mass spectrometry phase, which is used for the identification and quantification of the components.
- In particular, the accuracy of peptide identification can be improved with the inclusion of C and N labelled peptide internal standards for more hydrophilic peptides. This means that the process can be fine-tuned for more accurate results by utilising peptides that are attracted to water.
Cite This Article
APA
Timms M, Steel R.
(2021).
Defining the specificity of recombinant human erythropoietin confirmation in equine samples by liquid chromatography-tandem mass spectrometry.
Drug Test Anal, 14(4), 676-689.
https://doi.org/10.1002/dta.3210 Publication
Researcher Affiliations
- Biological Research Unit, Racing Analytical Services Ltd, Flemington, Victoria, Australia.
- Biological Research Unit, Racing Analytical Services Ltd, Flemington, Victoria, Australia.
MeSH Terms
- Animals
- Chromatography, Liquid / methods
- Erythropoietin / analysis
- Horses
- Humans
- Isoleucine
- Leucine
- Recombinant Proteins / analysis
- Tandem Mass Spectrometry / methods
References
This article includes 28 references
- Barbosa C, Romu00e3o L. Translation of the human erythropoietin transcript is regulated by an upstream open reading frame in response to hypoxia. RNA. 2014;20(5):594-608.
- Bartlett C, Clancy GJ, Cowan DA, Healy JF. Detection of the administration of human erythropoietin (HuEPO) to canines. J Anal Toxicol. 2006;30(9):663-669.
- Fisher JW, Koury S, Ducey T, Mendel S. Erythropoietin production by interstitial cells of hypoxic monkey kidneys. Br J Haematol. 1996;95(1):27-32.
- Haase VH. Regulation of erythropoiesis by hypoxia-inducible factors. Blood Rev. 2013;27(1):41-53.
- Lodewijkx HFM, Brouwer B. Some empirical notes on the epo epidemic in professional cycling. Res Q Exerc Sport. 2011;82(4):740-754.
- Lu00f6nnberg M, Bondesson U, Cormant F, et al. Detection of recombinant human EPO administered to horses using MAIIA lateral flow isoform test. Anal Bioanal Chem. 2012;403(6):1619-1628.
- Spivak JL. Erythropoietin use and abuse: when physiology and pharmacology collide. Adv Exp Med Biol. 2001;502:207-224.
- Reichel C. Application of high-throughput IEF-PAGE for EPO-doping testing. Drug Test Anal. 2012;4(9):728-732.
- Guan F, Uboh CE, Soma LR, Maylin G, Jiang Z, Chen J. Confirmatory analysis of continuous erythropoietin receptor activator and erythropoietin analogues in equine plasma by LC-MS for doping control. Anal Chem. 2010;82(21):9074-9081. 10.1021/ac102031w.
- Reichel C, Thevis M. Detection of EPO-Fc fusion protein in human blood: screening and confirmation protocols for sports drug testing. Drug Test Anal. 2012;4(11):818-829.
- Lasne F, Martin L, Crepin N, de Ceaurriz J. Detection of isoelectric profiles of erythropoietin in urine: differentiation of natural and administered recombinant hormones. Anal Biochem. 2002;311(2):119-126.
- Lasne F, Popot MA, Varlet-Marie E, et al. Detection of recombinant epoetin and darbepoetin alpha after subcutaneous administration in the horse. J Anal Toxicol. 2005;29(8):835-837.
- Guan F, Uboh CE, Soma LR, et al. LC-MS/MS method for confirmation of recombinant human erythropoietin and darbepoetin alpha in equine plasma. Anal Chem. 2007;79(12):4627-4635.
- Delcourt V, Garcia P, Chabot B, et al. Screening and confirmatory analysis of recombinant human erythropoietin for racing camels' doping control. Drug Test Anal. 2020;12(6):763-770.
- Timms M, Steel R, Vine J. Identification of recombinant human EPO variants in greyhound plasma and urine by ELISA, LC-MS/MS and western blotting: a comparative study. Drug Test Anal. 2016;8(2):164-176. https://doi.org/10.1002/dta.1835
- Scarth JP, Seibert C, Brown PR, et al. UPLC-MS/MS method for the identification of recombinant human erythropoietin analogues in horse plasma and urine. Chromatographia. 2011;74(7-8):593-608. https://doi.org/10.1007/s10337-011-2119-y
- Chang Y, Maylin GM, Matsumoto G, Neades SM, Catlin DH. Screen and confirmation of PEG-epoetin u03b2 in equine plasma. Drug Test Anal. 2011;3(1):68-73.
- Bailly-Chouriberry L, Cormant F, Garcia P, et al. A new analytical method based on anti-EPO monolith column and LC-FAIMS-MS/MS for the detection of rHuEPOs in horse plasma and urine samples. Analyst. 2012;137(10):2445-2453.
- Peterman SM. Developing a Method to Protect the Integrity of Racing Using Targeted SRM: Detection and Quantitation of rhEPO/DPO in Horse Plasma. https://assets.thermofisher.com/TFS-Assets/CMD/Application-Notes/AN-408-MS-rhEPO-DPO-Horse-Plasma-AN62502-EN.pdf
- Xiao Y, Vecchi MM, Wen D. Distinguishing between leucine and isoleucine by integrated LC-MS analysis using an orbitrap fusion mass spectrometer. Anal Chem. 2016;88(21):10757-10766.
- Armirotti A, Millo E, Damonte G. How to discriminate between leucine and isoleucine by low energy ESI-TRAP MSn. J am Soc Mass Spectrom. 2007;18(1):57-63.
- Zhokhov SS, Kovalyov SV, Samgina TY, Lebedev AT. An EThcD-based method for discrimination of leucine and isoleucine residues in tryptic peptides. J am Soc Mass Spectrom. 2017;28(8):1600-1611.
- AORC MS Criteria (modified 23 Aug 16) - Association of Official Racing Chemists. http://www.aorc-online.org/documents/aorc-ms-criteria-modified-23-aug-16/
- Fredolini C, Bystru00f6m S, Sanchez-Rivera L, et al. Systematic assessment of antibody selectivity in plasma based on a resource of enrichment profiles. Sci Rep. 2019;9(1):8324.
- Ignjatovic V, Geyer PE, Palaniappan KK, et al. Mass spectrometry-based plasma proteomics: considerations from sample collection to achieving translational data. J Proteome Res. 2019;18(12):4085-4097.
- Tripet B, Cepeniene D, Kovacs JM, Mant CT, Krokhin OV, Hodges RS. Requirements for prediction of peptide retention time in reversed-phase high-performance liquid chromatography: hydrophilicity/hydrophobicity of side-chains at the N- and C-termini of peptides are dramatically affected by the end-groups and location. J Chromatogr a. 2007;1141(2):212-225.
- Zhou NE, Mant CT, Hodges RS. Effect of preferred binding domains on peptide retention behavior in reversed-phase chromatography: amphipathic alpha-helices. Pept Res. 1990;3(1):8-20.
- Jelkmann W. Physiology and pharmacology of erythropoietin. Transfus Med Hemother. 2013;40(5):302-309.
Citations
This article has been cited 1 times.- Jamieson CA, Baillie SL, Johnson JP. Blood Transfusion in Equids-A Practical Approach and Review.. Animals (Basel) 2022 Aug 23;12(17).