Analyze Diet
Journal of pharmaceutical and biomedical analysis2008; 48(3); 902-908; doi: 10.1016/j.jpba.2008.07.024

Development of a liquid chromatography-tandem mass spectrometry method for an euthanasic veterinarian drug: Tanax.

Abstract: A development of a rapid and sensitive LC-MS/MS method for the simultaneous detection of active ingredients of the euthanasic veterinarian drug Tanax mixture is described. The method proposed, with a retention time of few minutes (6 min) was developed for an equine serum sample with solid-phase extraction (S.P.E). This S.P.E. procedure has been revealed useful for the determination of very low concentrations of Tanax analytes (0.05-1 ng/ml). The method was validated in terms of specificity/selectivity, sensitivity, recovery and precision.
Publication Date: 2008-08-08 PubMed ID: 18818042DOI: 10.1016/j.jpba.2008.07.024Google Scholar: Lookup
The Equine Research Bank provides access to a large database of publicly available scientific literature. Inclusion in the Research Bank does not imply endorsement of study methods or findings by Mad Barn.
  • Journal Article

Summary

This research summary has been generated with artificial intelligence and may contain errors and omissions. Refer to the original study to confirm details provided. Submit correction.

The researchers have developed a swift and sensitive method for detecting the active ingredients of a euthanasia veterinary drug, Tanax, using Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS). This method can identify very low concentrations of Tanax and has been tested for effectiveness.

Method Development

  • In this research, the authors have developed a method using Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) to detect and quantify the active ingredients in a euthanasic veterinary drug called Tanax.
  • LC-MS/MS is a chemical analysis technique often used in drug testing to detect and identify molecules in a sample. It works by separating the individual components (in this case, the active ingredients in Tanax) and then analysing them to determine their quantity.

Short Retention Time

  • The new method has a short retention time, meaning it’s able to detect the active ingredients of Tanax quickly. The retention time in this case was just 6 minutes.
  • A shorter retention time could make this method more suitable for high-throughput testing where large volumes of samples need to be analysed in a short space of time.

Solid-Phase Extraction

  • The study used a technique called solid-phase extraction (SPE) to prepare the equine serum samples for testing.
  • SPE is a commonly used technique for extracting particular substances from a mixture. It’s used here to isolate the active ingredients of Tanax from the equine serum.
  • The use of SPE in this context suggests that the method developed could be particularly useful for testing therapeutic levels of Tanax in horses or other large animals.

Detection of Low Concentrations

  • This newly developed method can detect very low concentrations of Tanax analytes (0.05-1 ng/ml).
  • Being able to detect such low concentrations would mean that even small amounts of the drug could be identified. This can be particularly important in toxicological investigations.

Method Validation

  • The developed method was validated in terms of its specificity/selectivity, sensitivity, recovery, and precision. In other words, it was shown to correctly identify and measure the active ingredients of Tanax, reliably detect even small quantities of the drug, successfully extract a high proportion of the drug from samples, and produce consistent and accurate results.
  • These aspects of validation are crucial in ensuring that the method is both scientifically robust and practically suitable for use in a laboratory or clinical setting.

Cite This Article

APA
Fidani M, Gamberini MC, Pasello E, Palazzoli F, Dimasi T, Montana M. (2008). Development of a liquid chromatography-tandem mass spectrometry method for an euthanasic veterinarian drug: Tanax. J Pharm Biomed Anal, 48(3), 902-908. https://doi.org/10.1016/j.jpba.2008.07.024

Publication

ISSN: 0731-7085
NlmUniqueID: 8309336
Country: England
Language: English
Volume: 48
Issue: 3
Pages: 902-908

Researcher Affiliations

Fidani, M
  • U.N.I.R.E. Lab. S.r.l., Via Gramsci 70, 20019 Settimo Milanese (MI), Italy.
Gamberini, M C
    Pasello, E
      Palazzoli, F
        Dimasi, T
          Montana, M

            MeSH Terms

            • Amides / analysis
            • Amides / chemistry
            • Amides / toxicity
            • Animals
            • Chromatography, Liquid / veterinary
            • Cyclohexanes / analysis
            • Cyclohexanes / toxicity
            • Drug Combinations
            • Drug Stability
            • Euthanasia
            • Flow Injection Analysis / methods
            • Horses
            • Molecular Structure
            • Quaternary Ammonium Compounds / analysis
            • Quaternary Ammonium Compounds / chemistry
            • Quaternary Ammonium Compounds / toxicity
            • Reproducibility of Results
            • Sensitivity and Specificity
            • Solid Phase Extraction / methods
            • Spectrometry, Mass, Electrospray Ionization / methods
            • Tandem Mass Spectrometry / veterinary
            • Tetracaine / analysis
            • Tetracaine / chemistry
            • Tetracaine / toxicity
            • Time Factors

            Citations

            This article has been cited 0 times.