Manual corneal thickness measurements of healthy equine eyes using a portable spectral-domain optical coherence tomography device.
Abstract: Corneal thickness measurements of the equine globe using spectral-domain optical coherence tomography (SD-OCT) have not been reported. Objective: To determine corneal thickness measurements and the intra- and interoperator reliability of a portable SD-OCT device in equine eyes. Methods: Prospective observational study. Methods: Horses free of ocular disease were used for this study. Gentle manual restraint, in combination with detomidine hydrochloride and a head stand, were employed to ensure proper animal positioning. Corneal pachymetry measurements were obtained from both eyes of each animal 3 times by 2 operators in succession. A 6 mm corneal pachymetry protocol was performed using a portable SD-OCT device. All measurements were obtained manually by one operator (C.G.P.) using the integrated calliper function. Measurements included epithelial thickness, stromal thickness, Descemet's membrane thickness and total corneal thickness. All recorded measurements were analysed to determine both intra- and interoperator reliability. Results: Thirty horses with a mean age of 10.6 ± 6.4 years were examined. Mean epithelial, stromal, Descemet's membrane and total corneal thickness values obtained were, respectively, 174.7 ± 13.6, 599.2 ± 45.4, 38.4 ± 15.3 and 812.0 ± 44.1 μm for operator A and 175.9 ± 12.9, 599.2 ± 44.9, 38.4 ± 15.0 and 812.9 ± 42.9 μm for operator B. A positive correlation was found between Descemet's membrane thickness and age, whereby Descemet's membrane thickness increased by 2 μm/year (P<0.0001). The coefficients of variation for both operators were <4% for all measurements. Intraclass correlations ranged from 0.92 to 0.98. Conclusions: Manual corneal thickness measurement using a portable SD-OCT device provides epithelial, stromal, Descemet's membrane and total corneal thickness measurements with clinically acceptable intra- and interoperator reliability in healthy equine eyes.
© 2013 EVJ Ltd.
Publication Date: 2013-12-09 PubMed ID: 24131285DOI: 10.1111/evj.12198Google Scholar: Lookup
The Equine Research Bank provides access to a large database of publicly available scientific literature. Inclusion in the Research Bank does not imply endorsement of study methods or findings by Mad Barn.
- Journal Article
Summary
This research summary has been generated with artificial intelligence and may contain errors and omissions. Refer to the original study to confirm details provided. Submit correction.
This study investigates the use of a portable spectral-domain optical coherence tomography (SD-OCT) device for manual corneal thickness measurements in healthy equine eyes and finds it provides reliable results.
Methodology
- The study took a prospective observational approach involving horses that were free from ocular disease.
- To ensure the correct positioning of the animals, they used gentle manual restraint combined with detomidine hydrochloride and a headstand.
- Both eyes on each horse were subjected to corneal pachymetry measurements three times by two operators successively.
- These measurements were accomplished using a 6mm corneal pachymetry protocol on a portable SD-OCT device.
- All the measurements were manually done by one operator using an integrated calliper function.
- The measurements involved estimating the thickness of the epithelium, stroma, Descemet’s membrane, and the total corneal thickness.
- These measurements were later analyzed to ascertain the reliability within and between operators.
Results
- The study involved 30 horses with a mean age of 10.6 ± 6.4 years.
- The mean epithelial, stromal, Descemet’s membrane, and total corneal thickness values recorded were, respectively, 174.7 ± 13.6, 599.2 ± 45.4, 38.4 ± 15.3 and 812.0 ± 44.1 μm for the first operator and 175.9 ± 12.9, 599.2 ± 44.9, 38.4 ± 15.0 and 812.9 ± 42.9 μm for the second operator.
- There was a positive correlation between the thickness of Descemet’s membrane and age, where the thickness of Descemet’s membrane increased by 2 μm/year (P<0.0001).
- The coefficients of variation for all measurements from both operators were less than 4%.
- Intraclass correlations ranged from 0.92 to 0.98.
Conclusion
- The study concludes that manual corneal thickness measurement using a portable SD-OCT device provides reliable measurements of epithelial, stromal, Descemet’s membrane, and total corneal thickness in healthy equine eyes.
Cite This Article
APA
Pirie CG, Alario AF, Barysauskas CM, Gradil C, Uricchio CK.
(2013).
Manual corneal thickness measurements of healthy equine eyes using a portable spectral-domain optical coherence tomography device.
Equine Vet J, 46(5), 631-634.
https://doi.org/10.1111/evj.12198 Publication
Researcher Affiliations
- Department of Clinical Sciences, Tufts Cummings School of Veterinary Medicine (TCSVM), North Grafton, Massachusetts, USA.
MeSH Terms
- Animals
- Cornea / anatomy & histology
- Female
- Horses / anatomy & histology
- Male
- Tomography, Optical Coherence / instrumentation
- Tomography, Optical Coherence / methods
- Tomography, Optical Coherence / veterinary
Citations
This article has been cited 2 times.- Slenter IJM, Hermans H, Ensink JM, Willems DS, Veraa S, Grinwis GCM, Boevé MH. Clinical, ultrasonographic, and histopathologic findings in seven horses with Descemet's membrane detachment: A case series.. Vet Ophthalmol 2020 Jan;23(1):181-189.
- Revold T, Abayneh T, Brun-Hansen H, Kleppe SL, Ropstad EO, Hellings RA, Sørum H. Listeria monocytogenes associated kerato-conjunctivitis in four horses in Norway.. Acta Vet Scand 2015 Nov 9;57:76.
Use Nutrition Calculator
Check if your horse's diet meets their nutrition requirements with our easy-to-use tool Check your horse's diet with our easy-to-use tool
Talk to a Nutritionist
Discuss your horse's feeding plan with our experts over a free phone consultation Discuss your horse's diet over a phone consultation
Submit Diet Evaluation
Get a customized feeding plan for your horse formulated by our equine nutritionists Get a custom feeding plan formulated by our nutritionists