Abstract: Intraocular pressure (IOP) assessment is a fundamental component of ophthalmic examinations in both veterinary and human medicine. Due to variations in IOP across species and potential differences among examiners, knowledge of normal IOP values obtained using different tonometers is essential. Unassigned: This study aimed to compare the repeatability and reproducibility of IOP values in horses obtained by three different examiners using rebound (Tonovet) and applanation (Tonopen Avia) tonometers. Unassigned: Thirty healthy criollo horses were examined. IOP was measured by three veterinarians with different levels of experience following routine ophthalmic evaluation. Statistical analyses included analysis of variance, Student's t-test, and calculation of the intraclass correlation coefficient (ICC). Unassigned: The mean IOP values were 26.16 ± 5.13 mm Hg with rebound tonometry and 22.55 ± 7.32 mm Hg with applanation tonometry, indicating a significant difference between the two devices. For the rebound measurements, the examiner-specific means were as follows: = 25.27 ± 4.9 mm Hg, = 25.80 ± 5.2 mm Hg, and = 27.40 ± 5.1 mm Hg. For applanation tonometry, the mean values were: = 20.03 ± 4.5 mm Hg, = 19.67 ± 6.0 mm Hg, and = 27.97 ± 10.3 mm Hg. Examiner C consistently obtained higher IOP values with the Tonopen Avia. The ICC was 0.41 for rebound tonometry, indicating satisfactory reproducibility, and 0.18 for applanation tonometry, indicating poor reproducibility. Unassigned: Rebound tonometry (Tonovet) yielded higher IOP values than applanation tonometry (Tonopen Avia) but demonstrated superior reproducibility and was less affected by examiner variability. These findings demonstrate that Tonovet is a more reliable tool for measuring IOP in horses under clinical and research conditions.
The Equine Research Bank provides access to a large database of publicly available scientific literature. Inclusion in the Research Bank does not imply endorsement of study methods or findings by Mad Barn.
This research summary has been generated with artificial intelligence and may contain errors and omissions. Refer to the original study to confirm details provided. Submit correction.
Overview
This study evaluated the consistency and reliability of intraocular pressure (IOP) measurements in horses using two different tonometry devices—rebound and applanation tonometers—performed by three examiners with varying experience levels.
The goal was to determine which device provides more repeatable and reproducible IOP readings, important for accurate ophthalmic assessments in veterinary medicine.
Introduction and Background
Intraocular pressure (IOP) is a key parameter measured during eye examinations to detect and monitor ocular health issues.
Different tonometers exist to measure IOP, with rebound and applanation being two common types.
Species differences and variability between examiners can influence IOP readings, so understanding reliable measurement methods is crucial, especially in horses, where normative values and measurement reliability are less established.
Objectives
Compare repeatability (consistency of repeated measurements by the same examiner) and reproducibility (consistency across different examiners) of IOP measurements in horses.
Use two tonometry techniques: rebound tonometry (Tonovet) and applanation tonometry (Tonopen Avia).
Assess measurements by three veterinarians with different experience levels to evaluate examiner effect on measurement variability.
Methodology
Subjects: 30 healthy Criollo horses were selected for the study to establish baseline data in a healthy population.
Measurement: IOP was measured on each horse’s eyes using both devices by three different veterinarians, ensuring varied clinical experience.
Statistical Analysis:
Analysis of variance (ANOVA) to detect significant differences in readings.
Student’s t-test for comparing mean IOP values between devices.
Intraclass correlation coefficient (ICC) to evaluate measurement repeatability and reproducibility among examiners.
Results
Mean IOP values:
Rebound tonometry (Tonovet): 26.16 ± 5.13 mm Hg
Applanation tonometry (Tonopen Avia): 22.55 ± 7.32 mm Hg
This difference in mean IOP values between devices was statistically significant, with rebound tonometry producing higher readings.
Examiner-specific mean values for rebound tonometry:
Examiner A: 25.27 ± 4.9 mm Hg
Examiner B: 25.80 ± 5.2 mm Hg
Examiner C: 27.40 ± 5.1 mm Hg
Examiner-specific mean values for applanation tonometry:
Examiner A: 20.03 ± 4.5 mm Hg
Examiner B: 19.67 ± 6.0 mm Hg
Examiner C: 27.97 ± 10.3 mm Hg (notably higher and more variable)
Intraclass Correlation Coefficients (ICC):
Rebound tonometry: 0.41, indicating satisfactory reproducibility among examiners.
Applanation tonometry: 0.18, indicating poor reproducibility and more variability among examiners.
Examiner C showed a tendency to record higher IOP values with applanation tonometry, indicating possible effect of examiner technique or experience on this device.
Discussion and Interpretation
Rebound tonometry (Tonovet) provided higher IOP measurements than applanation tonometry (Tonopen Avia), which aligns with previous observations in veterinary ophthalmology.
The rebound tonometer demonstrated better reproducibility and was less influenced by who performed the measurement, suggesting higher reliability for clinical and research use in horses.
Applanation tonometry showed greater variability depending on the examiner, lowering its reliability, possibly due to its measurement technique being more sensitive to user skill.
This finding implies that when consistent IOP readings are required in equine ophthalmic exams, rebound tonometry is preferred.
Conclusions
Tonovet rebound tonometer offers more reliable and consistent IOP measurements in horses compared to Tonopen Avia applanation tonometer.
Rebound tonometry is less affected by examiner variability, making it suitable for both clinical evaluations and research involving equine IOP measurement.
Practitioners and researchers should consider device choice carefully to ensure reliable IOP monitoring in horses.