Veterinary research communications2026; 50(6); 545; doi: 10.1007/s11259-026-11486-9

Electrocardiographic recording in horses at rest: a concordance analysis of two methods.

Abstract: Cardiac arrhythmias are frequently detected during routine auscultation in athletic horses. Assessment of their clinical significance requires electrocardiography (ECG) to analyze waveforms and intervals. In recent years, portable ECG devices have been introduced to simplify electrocardiographic examination, offering advantages such as ease of use and the ability to review results via a smartphone. This study evaluated the utility and accuracy of a portable ECG device compared with a standard electrocardiograph. Simultaneous ECG recordings were obtained from 28 healthy adult horses at rest using a portable device (eKuore) and a standard electrocardiograph (Cardioline Vet600). Agreement between the two methods was assessed using Passing-Bablok regression and Bland-Altman analysis. All recordings were independently interpreted by two observers. A significant bias was observed between methods for heart rate, PR interval, and QRS duration, with higher values obtained using the portable device. Two arrhythmias were identified: second-degree atrioventricular block and atrial fibrillation. Agreement for arrhythmia detection was perfect (κ = 1.00), while agreement for heart rhythm classification (bradycardia, normal rhythm, or tachycardia) was good (κ = 0.73). In conclusion, the portable device demonstrated good diagnostic performance for arrhythmia detection during routine clinical examinations. However, further studies are required to establish reference intervals specific to this device.
Publication Date: 2026-09-01 PubMed ID: 42678642PubMed Central: 7517866DOI: 10.1007/s11259-026-11486-9Google Scholar: Lookup
The Equine Research Bank provides access to a large database of publicly available scientific literature. Inclusion in the Research Bank does not imply endorsement of study methods or findings by Mad Barn.
  • Journal Article

Summary

This research summary has been generated with artificial intelligence and may contain errors and omissions. Refer to the original study to confirm details provided. Submit correction.

Overview

  • This study compares the accuracy and reliability of a portable ECG device with a standard electrocardiograph in recording and analyzing the heart activity of horses at rest.
  • It focuses on the agreement between the two methods in measuring heart rate, intervals, and detecting arrhythmias in healthy horses.

Background and Purpose

  • Cardiac arrhythmias—irregular heartbeats—are commonly found during routine check-ups of athletic horses.
  • To understand the clinical impact of these arrhythmias, electrocardiography (ECG) is necessary; it helps analyze specific aspects of the heartbeat waveform, including timing intervals.
  • Portable ECG devices have been recently introduced, promising benefits such as ease of use and the ability to view results via smartphones.
  • This study set out to evaluate whether a portable ECG device (eKuore) produces results comparable to those of a traditional, standard ECG machine (Cardioline Vet600) when used on horses at rest.

Methodology

  • Researchers conducted simultaneous ECG recordings on 28 healthy adult horses using both the portable device and the standard electrocardiograph.
  • Data collected included measurements of heart rate, PR interval (the time between atrial and ventricular contractions), and QRS duration (ventricular contraction time).
  • Two observers independently interpreted all ECG recordings to ensure unbiased analysis.
  • The study applied statistical methods, including Passing-Bablok regression and Bland-Altman analysis, to assess the agreement between the two devices’ measurements.

Key Findings

  • There was a statistically significant difference (bias) in measurements of heart rate, PR interval, and QRS duration between the two methods, with the portable device consistently showing higher values.
  • Two types of arrhythmias were detected across the horses: second-degree atrioventricular (AV) block and atrial fibrillation.
  • When it came to identifying arrhythmias, the agreement between the portable and standard devices was perfect (κ=1.00), indicating excellent concordance.
  • For classifying heart rhythm into categories of bradycardia (slow heart rate), normal rhythm, or tachycardia (fast heart rate), agreement was good but not perfect (κ=0.73).

Conclusions and Implications

  • The portable ECG device performed well in detecting cardiac arrhythmias during routine clinical examinations in resting horses.
  • Its ease of use and capability to transmit results via smartphone make it a potentially valuable tool for equine veterinary practice.
  • However, because the portable device tended to return higher values for key measurements, establishing specific reference intervals for this device is necessary to interpret results accurately.
  • Further research is recommended to validate these findings across different conditions and populations of horses, potentially broadening the clinical applicability of portable ECG technology.

Cite This Article

APA
(2026). Electrocardiographic recording in horses at rest: a concordance analysis of two methods. Vet Res Commun, 50(6), 545. https://doi.org/10.1007/s11259-026-11486-9

Publication

ISSN: 1573-7446
NlmUniqueID: 8100520
Country: Switzerland
Language: English
Volume: 50
Issue: 6
PII: 545

Researcher Affiliations

MeSH Terms

  • Animals
  • Horses / physiology
  • Electrocardiography / veterinary
  • Electrocardiography / instrumentation
  • Electrocardiography / methods
  • Arrhythmias, Cardiac / veterinary
  • Arrhythmias, Cardiac / diagnosis
  • Female
  • Male
  • Horse Diseases / diagnosis
  • Heart Rate

Conflict of Interest Statement

Declarations. Ethical approval: This protocol was approved by the Animal Experimentation Ethics Advisory Committee of the University of Zaragoza (Ref. PD36/20NE). Consent to participate: Informed consent was obtained from all owners of subjects involved in the study. Consent to publish: Not applicable. Competing interests: The authors declare no competing interests.

References

This article includes 21 references
  1. Alibrandi L, Tognetti R, Domenech O, Croce M, Giuntoli M, Grosso G, Vezzosi T. Smartphone-based six-lead ECG: A new device for electrocardiographic recording in dogs.. Vet J 303:106043.
    doi: 10.1016/j.tvjl.2023.106043pubmed: 37992801google scholar: lookup
  2. Bindi F, Vezzosi T, Sala G, Freccero F, Marmorini P, Bonelli F, Sgorbini M. Evaluation of a smartphone electrocardiograph in healthy foals and comparison to standard base-apex electrocardiography.. Vet Res Commun 48:1227–1232.
    doi: 10.1007/s11259-023-10206-xpubmed: 37947988google scholar: lookup
  3. Brložnik M, Petrič AD, Kos VK, Rashkovska A, Avbelj V. Body sensor for electrocardiographic monitoring in equine medicine.. 42nd International convention on information and communication technology, electronics and microelectronics (MIPRO) Opatia (Croatia).
  4. Buhl R, Meldgaard C, Barbesgaard L. Cardiac arrhythmias in clinically healthy showjumping horses.. Equine Vet J Suppl 196–201.
  5. Corradini I, Fernández-Ruiz A, Barba M, Engel-Manchado J. Stall-side screening potential of a smartphone electrocardiogram recorded over both sides of the thorax in horses.. J Vet Intern Med 34:2101–2108.
    doi: 10.1111/jvim.15795pubmed: 32639655pmc: 7517866google scholar: lookup
  6. Decloedt A, Van Steenkiste G, Vera L, Buhl R, van Loon G. Atrial fibrillation in horses part 1: Pathophysiology.. Vet J 263:105521.
    doi: 10.1016/j.tvjl.2020.105521pubmed: 32928494google scholar: lookup
  7. Gunasekaran T, Prabhakar S, Sanders RA. Assessment of heart rate measurements obtained from smartphone electrocardiography as compared to 24-h Holter monitoring in dogs with atrial fibrillation.. J Vet Cardiol 62:60–67.
    doi: 10.1016/j.jvc.2025.08.002pubmed: 40897129google scholar: lookup
  8. Haberman ZC, Jahn RT, Bose R, Tun H, Shinbane JS, Doshi RN, Chang PM, Saxon LA. Wireless smartphone ECG enables large-scale screening in diverse populations.. J Cardiovasc Electrophysiol 26:520–526.
    doi: 10.1111/jce.12634pubmed: 25651872google scholar: lookup
  9. Kjeldsen ST, Nissen SD, Buhl R, Hopster-Iversen C. Paroxysmal atrial fibrillation in horses: Pathophysiology, diagnostics and clinical aspects.. Animals 12:698.
    doi: 10.3390/ani12060698pubmed: 35327097pmc: 8944606google scholar: lookup
  10. Kraus MS, Rishniw M, Divers TJ, Reef VB, Gelzer AR. Utility and accuracy of a smartphone-based electrocardiogram device as compared to a standard base-apex electrocardiogram in the horse.. Res Vet Sci 125:141–147.
    doi: 10.1016/j.rvsc.2019.05.018pubmed: 31228737google scholar: lookup
  11. McBride GB. A proposal for strength-of-agreement criteria for Lin’s concordance correlation coefficient.. NIWA Client Report HAM2005-062.
  12. Nath LC, Elliott AD, Weir J, Curl P, Rosanowski SM, Franklin S. Incidence, recurrence, and outcome of postrace atrial fibrillation in Thoroughbred horses.. J Vet Intern Med 35:1111–1120.
    doi: 10.1111/jvim.16063pubmed: 33604980pmc: 7995445google scholar: lookup
  13. Reed SM, Bayly WM, Sellon DC. Equine internal medicine, 4th edn.. Elsevier .
  14. Spitale D, Cicogna M, Porciello F, Colonnelli M, Caivano D. Use of a novel Smartphone based single-lead electrocardiogram device in clinical practice to evaluate heart rhythm in horses- a case series.. Pferdeheikunde-Equine Med 40:149–153.
    doi: 10.21836/PEM20240207google scholar: lookup
  15. Ter Woort F, Dubois G, Tansley G, Didier M, Verdegaal L, Franklin S, Van Erck-Westergren E. Validation of an equine fitness tracker: ECG quality and arrhythmia detection.. Equine Vet J 55:336–343.
    doi: 10.1111/evj.13565pubmed: 35138653pmc: 10078706google scholar: lookup
  16. van Erck-Westergren E, O’Connor S, Stewart BD, Dubois G, Morton J, Hinchcliff KW, Ter Woort F. Cardiac arrhythmias during intense exercise in thoroughbred racehorses: Frequency and association with subsequent race performance. J Vet Inter Med 40:2.
    doi: 10.1093/jvimsj/aalag044google scholar: lookup
  17. van Loon G. Cardiac Arrhythmias in Horses. Vet Clin North Am Equine Pract 35:85–102.
    doi: 10.1016/j.cveq.2018.12.004pubmed: 30871832google scholar: lookup
  18. Vezzosi T, Buralli C, Marchesotti F, Porporato F, Tognetti R, Zini E, Domenech O. Diagnostic accuracy of a smartphone electrocardiograph in dogs: Comparison with standard 6-lead electrocardiography. Vet J 216:33–37.
    doi: 10.1016/j.tvjl.2016.06.013pubmed: 27687923google scholar: lookup
  19. Vezzosi T, Sgorbini M, Bonelli F, Buralli C, Pillotti M, Meucci V, Tognetti R. Evaluation of a smartphone electrocardiography en healthy horses: Comparison with standard base-apex elctrocardiography. J Equine Vet Sci 67:61–65.
  20. Vitale V, Vezzosi T, Tognetti R, Fraschetti C, Sgorbini M. Evaluation of a new portable 1-lead digital cardiac monitor (eKuore) compared with standard base-apex electrocardiography in healthy horses. PLoS ONE 16:e0255247.
    doi: 10.1371/journal.pone.0255247pubmed: 34343184pmc: 8330948google scholar: lookup
  21. Welch-Huston B, Durward-Akhurst S, Norton E, Ellingson L, Rendahl A, McCue M. Comparison between smartphone electrocardiography and standard three-lead base apex electrocardiography in healthy horses. Vet Rec 187:e70.
    doi: 10.1136/vr.105759pubmed: 32414909pmc: 7606555google scholar: lookup

Citations

This article has been cited 0 times.