Material science in the context of equine studies involves the examination and application of materials used in horse care, equipment, and facility construction. This field encompasses the development and analysis of materials such as metals, polymers, ceramics, and composites that are utilized in the production of horseshoes, saddles, blankets, and stable flooring. The properties of these materials, including durability, flexibility, weight, and thermal regulation, are critical for ensuring the safety, comfort, and performance of horses. Research in this area includes studies on the wear resistance of horseshoes, the impact absorption of saddle pads, and the thermal insulation properties of horse blankets. This page compiles peer-reviewed research studies and scholarly articles that explore the design, testing, and application of various materials in equine environments.
Lazarus BS, Luu RK, Ruiz-Pérez S, Bezerra WBA, Becerra-Santamaria K, Leung V, Durazo VHL, Jasiuk I, Barbosa JDV, Meyers MA.The horse hoof wall exhibits exceptional impact resistance and fracture control due to its unique hierarchical structure which contains tubular, lamellar, and gradient configurations. In this study, structural characterization of the hoof wall was performed revealing features previously unknown. Prominent among them are tubule bridges, which are imaged and quantified. The hydration-dependent viscoelasticity of the hoof wall is described by a simplified Maxwell-Weichert model with two characteristic relaxation times corresponding to nanoscale and mesoscale features. Creep and relaxation tests r...
Bolaños RV, Castilho M, de Grauw J, Cokelaere S, Plomp S, Groll J, van Weeren PR, Gbureck U, Malda J.Bone has great self-healing capacity, but above a certain critical size, bone defects will not heal spontaneously, requiring intervention to achieve full healing. Among the synthetic calcium phosphate (CaP) bone replacement materials, brushite (CaHPO·2HO)-based materials are of particular interest because of their degree of solubility and the related high potential to promote bone regeneration after dissolution. They can be produced tailor-made using modern three-dimensional (3D) printing technology. Although this type of implant has been widely tested in vitro, there are only limited in vivo...
Du H, Yousefian O, Horn T, Muller M.The mode-converted (longitudinal to transverse, L-T) ultrasonic scattering method was utilized to characterize the structural anisotropy of a phantom mimicking the structural properties of trabecular bone. The sample was fabricated using metal additive manufacturing from high-resolution computed tomography (CT) images of a sample of trabecular horse bone with strong anisotropy. Two focused transducers were used to perform the L-T ultrasonic measurements. A normal incidence transducer was used to transmit longitudinal ultrasonic waves into the sample, while the scattered transverse signals were...
Terzi A, Gallo N, Bettini S, Sibillano T, Altamura D, Campa L, Natali ML, Salvatore L, Madaghiele M, De Caro L, Valli L, Sannino A, Giannini C.The aim of this work is to evaluate the effects of different extraction and material processing protocols on the collagen structure and hierarchical organization of equine tendons. Wide and Small Angle X-ray Scattering investigations on raw powders and thin films revealed that not only the extraction and purification treatments, but also the processing conditions may affect the extent of the protein crystalline domain and induce a nanoscale "shield effect." This is due to the supramolecular fiber organization, which protects the atomic scale structure from the modifications that occur during f...
Mao J, Rassoli A, Tong Y, Rouse EN, Le-Bel G, How D, Germain L, Fatouraee N, Zhang Z, Reed RR, Guidoin R.Transcatheter aortic valve implantation (TAVI) has gained considerable acceptance in the past decade due to its lower risks than conventional open-heart surgery. However, the deformation and delamination of the leaflets during the crimping procedure have raised questions about the durability and long-term serviceability of the pericardium tissue from which the leaflets are made. The collagen architecture, wall thickness and mechanical properties of donkey pericardium were investigated to assess its suitability as an alternative material for the manufacture of heart valves. Coupons sampled from...
McGlinchey L, Boone LH, Munsterman AS, Coleridge MOD, Rosanowski SM, Farag R, Hanson RR.To evaluate the effect of exposure to a balanced electrolyte solution (BES), or equine abdominal fat on the knot-holding capacity (KHC), relative knot security (RKS), weight, and volume of forwarder knots versus surgeon's knots. Methods: 315 knots tied and tested in vitro. Methods: United States Pharmacopeia size-3 polyglactin 910 suture exposed to air (dry [control]), equine abdominal fat (fat-exposed), or BES (BES-exposed) was used to tie forwarder knots with 2, 3, and 4 throws and surgeon's knots with 5, 6, 7, and 8 throws. A universal materials testing machine was used to test the tensile ...
Shivaram A, Bose S, Bandyopadhyay A.The primary objective of this research was to evaluate the extent of mechanical degradation on TiO2 nanotubes on Ti with and without nano-particulate silver coating using two different lengths of TiO2 nanotubes-300nm and ~1µm, which were fabricated on commercially pure Titanium (cp-Ti) rods using anodization method using two different electrolytic mediums-(1) deionized (DI) water with 1% HF, and (2) ethylene glycol with 1% HF, 0.5wt% NH4F and 10% DI water. Nanotubes fabricated rods were implanted into equine cadaver bone to evaluate mechanical damage at the surface. Silver was electrochemical...
Sanders RE, Kearney CM, Buckley CT, Jenner F, Brama PA.To evaluate knot security for 3 knot types created in 3 commonly used 5 metric suture materials incubated in physiological and pathological fluids. Methods: In vitro mechanical study. Methods: Knotted suture loops (n = 5/group). Methods: Loops of 3 different suture materials (glycolide/lactide copolymer; polyglactin 910; polydioxanone) were created around a 20 mm rod using 3 knot types (square [SQ], surgeon's [SK], and triple knot [TK]) and were tested to failure in distraction (6 mm/min) after tying (day 0) and after being incubated for 14 and 28 days in phosphate buffered saline (PBS...
Listoni AJ, Arruda I, Maia L, Barberini DJ, Martins I, Vasconcellos FC, Landim-Alvarenga FC.Nanotechnology techniques have a prominent role in the current technical and scientific scene. The layer-by-layer (LbL) deposition allows obtaining nanostructures with sophisticated multilayer, using a simple, but versatile technique. This procedure, which is used to coat and functionalize surfaces with nanometer- thick films, has applications in bioengineering, medicine, chemistry, materials and chemical engineering among other areas. Chitosan is a biomaterial, coming from the chitin, a very abundant polymer in nature, which has been recently tested as scaffolds. In this experiment we test th...
Barrett EJ, Munsterman AS, Hanson RR, Jackson RL.To compare in vitro strength and failure characteristics of a tendon implant against a 3 loop pulley suture pattern for equine superficial digital flexor tendon (SDFT) laceration repair. Methods: Experimental. Methods: Cadaveric equine forelimb SDFT (n = 16). Methods: One tendon of each of 8 pair of SDFT was randomly selected for repair with either the 3-loop pulley (3LP) suture pattern using 2 polydioxanone or with 4 stainless steel suture and anchor implants (SA). Ultimate load to failure, mode of failure, gap at failure, and load to 2 mm gap were obtained using a materials testing sys...
Tüfekci K, Kayacan R, Kurbanoğlu C.Gamma radiation has been widely used for sterilization of bone allograft. However, sterilization by gamma radiation damages the material properties of bone which is a major clinical concern since bone allograft is used in load bearing applications. While the degree of this damage is well investigated for quasi-static and cyclic loading conditions, there does not appear any information on mechanical behavior of gamma-irradiated cortical bone at high speed loading conditions. In this study, the effects of gamma irradiation on high strain rate compressive behavior of equine cortical bone were inv...
Kearney CM, Buckley CT, Jenner F, Moissonnier P, Brama PA.Selection of suture material in equine surgery is often based on costs or subjective factors, such as the surgeon's personal experience, rather than objective facts. The amount of objective data available on durability of suture materials with regard to specific equine physiological conditions is limited. Objective: To evaluate the effect of various equine physiological and pathological fluids on the rate of degradation of a number of commonly used suture materials. Methods: In vitro material testing. Methods: Suture materials were exposed in vitro to physiological fluid, followed by biomechan...
O'Hare LM, Cox PG, Jeffery N, Singer ER.To improve understanding of the internal structure of the proximal phalanx (P1), response of the bone to load and possible relation to the pathogenesis of fractures in P1. Objective: To model the P1 and replicate the loads experienced by the bone in stance, walk, trot and gallop using finite element analysis. Methods: The geometry of the P1 was captured using micro-computed tomography (μCT) and was reconstructed in 3 dimensions. Values for material properties and forces experienced at stance, walk, trot and gallop were taken from the literature and were applied to the reconstructed model. Usi...
Wullschleger L, Weisse B, Blaser D, Fürst AE.Four radii of different horses were tested in three-point bending and in pure torsion. Detailed finite element (FE) models of these long bones were established by means of computed-tomography (CT) images and tests simulated for both load cases. For the allocation of the local isotropic material stiffness, individual exponential functions were applied whose factor and exponent were determined solely by fitting them to the measured torsional stiffness and bending stiffness of the entire bones. These stiffness functions referring directly to the CT number and having exponents between 1.5 and 2 we...
Bigley RF, Gibeling JC, Stover SM, Hazelwood SJ, Fyhrie DP, Martin RB.Volume effects are a fundamental determinant of structural failure. A material exhibits a volume effect if its failure properties are dependent on the specimen volume. Many brittle ceramics exhibit volume effects due to loading a structure in the presence of "critical" flaws. The number of flaws, their locations, and the effect of stress field within the stressed volume play a role in determining the structure's failure properties. Since real materials are imperfect, structures composed of large volumes of material have higher probabilities of containing a flaw than do small volumes. Consequen...
Pardoe CH, McGuigan MP, Rogers KM, Rowe LL, Wilson AM.Previous studies on shoeing have demonstrated that shoe material alters the time taken from foot impact to the foot stopping sliding (slip time) and the distance slid. These are assumed to reflect differences in the craniocaudal ground reaction force (GRF) between the shoe and the ground during foot slip. This study tested the hypothesis that the slip time and distance are reflected in the resistance to slippage of the foot after impact. The forefeet of 8 horses were shod in horseshoes constructed of steel, plastic and rubber. Each horse was trotted for 8 placements per forefoot in each shoe t...
Brandstetter J, Stanek C, Hinterhofer C.The use of handmade particulate reinforced alloy horseshoes (MMC metal matrix composites) was tested in a field study on 15 riding and draught horses. All horseshoes have been tempered after having been manually forged and tested concerning their surface imperfection. Forging temperature ranged between 350 degrees and 420 degrees C. Horseshoes in series A consisted of particulate reinforced wrought alloy (22% Al2O3 in alloy matrix). 11 shoeing periods with a duration of mean = 49.7 days (sd = 13.6) were evaluated. Horseshoes in series B consisted of particulate reinforced foundry alloy (20% Si...
Newlyn HA, Collins SN, Cope BC, Hopegood L, Latham RJ, Reilly JD.A finite element model of donkey hoof wall was constructed from measurements taken directly from the hoof capsule of the left forefoot. The model was created with a 2 mm mesh and consisted of 11,608 nodes. A linear elastic analysis was conducted assuming isotropic material properties in response to a 375 newton (N) load, to simulate static loading. The load was applied to the wall via 400 laminae in order to simulate the way in which the pedal bone is suspended within the donkey hoof capsule. Displacement, stress concentration, principal strain, and force distribution across the hoof wall were...
Kasapi MA, Gosline JM.Small-scale components of the equine hoof wall were tested to determine their mechanical roles in the morphological hierarchy. Macroscale tensile tests conducted on samples of the inner wall tubules and intertubular material showed a sixfold difference in mean initial stiffnesses (0.47 and 0.08 GPa, respectively), indicating that the inner wall tubules stiffen the wall along its longitudinal axis. The similarity in material properties of tubule and intertubular samples from the mid-wall suggests that tubules in this region offer only minor reinforcement along the longitudinal axis. Microscale ...
Peterson ML, Srinath S, Murphy J.A new instrument is presented which is capable of high resolution acoustic imaging at relatively low frequencies. This approach results in increased complexity of the signal processing required and reduced throughput of the instrument. However, these disadvantages are amply compensated by the ability to create velocity scan images of materials with either high attenuation or low material velocities. These measurements are not possible using traditional/acoustic microscopes. The initial performance of the new instrument is demonstrated using thin samples of shim materials to show that acceptabl...
Les CM, Stover SM, Keyak JH, Taylor KT, Willits NH.The distribution of material properties within the equine third metacarpal bone (MC3), and its possible effect on the mechanics of the structure, was quantitatively evaluated using single-load-to-failure compressive materials testing of specimens from ten horses. Bone samples from six regions within five proximodistal levels of MC3 were milled into right cylinders and compressed at a strain rate of 0.01 s-1. Diaphyseal MC3 bone material was stiffer, stronger, deformed less to yield and failure, and absorbed more energy to yield, than metaphyseal cortical bone material. Lateral and medial MC3 c...
Gillis C, Sharkey N, Stover SM, Pool RR, Meagher DM, Willits N.Results of studies in human beings and other species have indicated that aging significantly influences the strength, modulus of elasticity, and energy storage ability of tendon. We wanted to determine the effects of aging on the material and ultrasonographic properties of equine superficial digital flexor (SDF) tendon. Ultrasonographic measurements of left forelimb SDF tendon cross-sectional area and mean echogenicity were made in 23 standing horses ranging in age from 2 to 23 years. All horses had not been in work for a minimum of 6 months prior to the study. After euthanasia, left forelimb ...
Becker CK, Savelberg HH, Barneveld A.The material properties of the accessory ligament of the deep digital flexor tendon (AL) of 21 forelimbs from horses between ages one day and 15 years were determined. The force (634-11416 N), failure stress (45-138 N/mm2), failure strain (7-24%) and tangent modulus (33-1639 MPa) are presented in relation to age. Tangent modulus did not indicate changes in elasticity due to age. The results demonstrate that complete ligament failures (CLF) of ALs of older horses (mean 7835 N) occur at lower forces than ALs of young adult horses (mean 8894 N). Sudden decreases, 'dips', in the force-time curves ...
Campbell EJ, Bailey JV.Tensile testing of reproducible loops of size 5 braided polyester, size 2 polyglycolic acid, size 2 monofilament nylon, and size 2 polydioxanone sutures was performed in vitro and after subcutaneous implantation in horses for 7, 14, and 28 days. Maximum breaking strength, energy absorption, and percentage elongation to breakage point were measured. Size 5 braided polyester had the highest maximum breaking strength and energy absorption over 28 days. Polydioxanone had better mechanical performance over 28 days than did polyglycolic acid. On day 28, none of these parameters was measurable in pol...
Dean PW, Nelson JK, Schumacher J.Cartilage retention strengths of laryngoplasty prostheses were compared in larynges of 2-, 3-, and 4-year-old horses, using doubled polyester and expanded polytetrafluoroethylene prostheses. Bilateral laryngoplasties were performed on each of 15 (seven 2-year-old, two 3-year-old, and six 4-year-old) larynges, which were collected at an abbatoir. Prostheses were secured to a mechanical testing machine, and tension causing arytenoid cartilage abduction was applied, until total failure of the cartilage or prosthesis resulted. Tension caused cricoid cartilage failure in 1 specimen, and muscular pr...
Collier MA, Lowe JE, Rendano VT.Materials fatigue and gross biocompatability of an implantable bone growth stimulator (BGS) were assessed in a 6-month trial using 6 ponies. The forelegs of each pony were implanted with a BGS; the right leg implant had the cathode and cathode lead preconnected by the manufacturer, and the left leg implant was connected at surgery. Evaluation was by radiographic and clinical examination at the beginning and end of the experimental period. Six of the 12 cathode leads (50%) and 7 of the 12 cathodes (58%) were broken at 6 months. All of the implanted preconnected cathode and insulated cathode lea...
Terzi A, Gallo N, Bettini S, Sibillano T, Altamura D, Campa L, Natali ML, Salvatore L, Madaghiele M, De Caro L, Valli L, Sannino A, Giannini C.The aim of this work is to evaluate the effects of different extraction and material processing protocols on the collagen structure and hierarchical organization of equine tendons. Wide and Small Angle X-ray Scattering investigations on raw powders and thin films revealed that not only the extraction and purification treatments, but also the processing conditions may affect the extent of the protein crystalline domain and induce a nanoscale "shield effect." This is due to the supramolecular fiber organization, which protects the atomic scale structure from the modifications that occur during f...
O'Hare LM, Cox PG, Jeffery N, Singer ER.To improve understanding of the internal structure of the proximal phalanx (P1), response of the bone to load and possible relation to the pathogenesis of fractures in P1. Objective: To model the P1 and replicate the loads experienced by the bone in stance, walk, trot and gallop using finite element analysis. Methods: The geometry of the P1 was captured using micro-computed tomography (μCT) and was reconstructed in 3 dimensions. Values for material properties and forces experienced at stance, walk, trot and gallop were taken from the literature and were applied to the reconstructed model. Usi...
Shivaram A, Bose S, Bandyopadhyay A.The primary objective of this research was to evaluate the extent of mechanical degradation on TiO2 nanotubes on Ti with and without nano-particulate silver coating using two different lengths of TiO2 nanotubes-300nm and ~1µm, which were fabricated on commercially pure Titanium (cp-Ti) rods using anodization method using two different electrolytic mediums-(1) deionized (DI) water with 1% HF, and (2) ethylene glycol with 1% HF, 0.5wt% NH4F and 10% DI water. Nanotubes fabricated rods were implanted into equine cadaver bone to evaluate mechanical damage at the surface. Silver was electrochemical...
Gillis C, Sharkey N, Stover SM, Pool RR, Meagher DM, Willits N.Results of studies in human beings and other species have indicated that aging significantly influences the strength, modulus of elasticity, and energy storage ability of tendon. We wanted to determine the effects of aging on the material and ultrasonographic properties of equine superficial digital flexor (SDF) tendon. Ultrasonographic measurements of left forelimb SDF tendon cross-sectional area and mean echogenicity were made in 23 standing horses ranging in age from 2 to 23 years. All horses had not been in work for a minimum of 6 months prior to the study. After euthanasia, left forelimb ...
Kearney CM, Buckley CT, Jenner F, Moissonnier P, Brama PA.Selection of suture material in equine surgery is often based on costs or subjective factors, such as the surgeon's personal experience, rather than objective facts. The amount of objective data available on durability of suture materials with regard to specific equine physiological conditions is limited. Objective: To evaluate the effect of various equine physiological and pathological fluids on the rate of degradation of a number of commonly used suture materials. Methods: In vitro material testing. Methods: Suture materials were exposed in vitro to physiological fluid, followed by biomechan...
Pardoe CH, McGuigan MP, Rogers KM, Rowe LL, Wilson AM.Previous studies on shoeing have demonstrated that shoe material alters the time taken from foot impact to the foot stopping sliding (slip time) and the distance slid. These are assumed to reflect differences in the craniocaudal ground reaction force (GRF) between the shoe and the ground during foot slip. This study tested the hypothesis that the slip time and distance are reflected in the resistance to slippage of the foot after impact. The forefeet of 8 horses were shod in horseshoes constructed of steel, plastic and rubber. Each horse was trotted for 8 placements per forefoot in each shoe t...
McGlinchey L, Boone LH, Munsterman AS, Coleridge MOD, Rosanowski SM, Farag R, Hanson RR.To evaluate the effect of exposure to a balanced electrolyte solution (BES), or equine abdominal fat on the knot-holding capacity (KHC), relative knot security (RKS), weight, and volume of forwarder knots versus surgeon's knots. Methods: 315 knots tied and tested in vitro. Methods: United States Pharmacopeia size-3 polyglactin 910 suture exposed to air (dry [control]), equine abdominal fat (fat-exposed), or BES (BES-exposed) was used to tie forwarder knots with 2, 3, and 4 throws and surgeon's knots with 5, 6, 7, and 8 throws. A universal materials testing machine was used to test the tensile ...
Dean PW, Nelson JK, Schumacher J.Cartilage retention strengths of laryngoplasty prostheses were compared in larynges of 2-, 3-, and 4-year-old horses, using doubled polyester and expanded polytetrafluoroethylene prostheses. Bilateral laryngoplasties were performed on each of 15 (seven 2-year-old, two 3-year-old, and six 4-year-old) larynges, which were collected at an abbatoir. Prostheses were secured to a mechanical testing machine, and tension causing arytenoid cartilage abduction was applied, until total failure of the cartilage or prosthesis resulted. Tension caused cricoid cartilage failure in 1 specimen, and muscular pr...
Tüfekci K, Kayacan R, Kurbanoğlu C.Gamma radiation has been widely used for sterilization of bone allograft. However, sterilization by gamma radiation damages the material properties of bone which is a major clinical concern since bone allograft is used in load bearing applications. While the degree of this damage is well investigated for quasi-static and cyclic loading conditions, there does not appear any information on mechanical behavior of gamma-irradiated cortical bone at high speed loading conditions. In this study, the effects of gamma irradiation on high strain rate compressive behavior of equine cortical bone were inv...
Campbell EJ, Bailey JV.Tensile testing of reproducible loops of size 5 braided polyester, size 2 polyglycolic acid, size 2 monofilament nylon, and size 2 polydioxanone sutures was performed in vitro and after subcutaneous implantation in horses for 7, 14, and 28 days. Maximum breaking strength, energy absorption, and percentage elongation to breakage point were measured. Size 5 braided polyester had the highest maximum breaking strength and energy absorption over 28 days. Polydioxanone had better mechanical performance over 28 days than did polyglycolic acid. On day 28, none of these parameters was measurable in pol...
Lazarus BS, Luu RK, Ruiz-Pérez S, Bezerra WBA, Becerra-Santamaria K, Leung V, Durazo VHL, Jasiuk I, Barbosa JDV, Meyers MA.The horse hoof wall exhibits exceptional impact resistance and fracture control due to its unique hierarchical structure which contains tubular, lamellar, and gradient configurations. In this study, structural characterization of the hoof wall was performed revealing features previously unknown. Prominent among them are tubule bridges, which are imaged and quantified. The hydration-dependent viscoelasticity of the hoof wall is described by a simplified Maxwell-Weichert model with two characteristic relaxation times corresponding to nanoscale and mesoscale features. Creep and relaxation tests r...
Bolaños RV, Castilho M, de Grauw J, Cokelaere S, Plomp S, Groll J, van Weeren PR, Gbureck U, Malda J.Bone has great self-healing capacity, but above a certain critical size, bone defects will not heal spontaneously, requiring intervention to achieve full healing. Among the synthetic calcium phosphate (CaP) bone replacement materials, brushite (CaHPO·2HO)-based materials are of particular interest because of their degree of solubility and the related high potential to promote bone regeneration after dissolution. They can be produced tailor-made using modern three-dimensional (3D) printing technology. Although this type of implant has been widely tested in vitro, there are only limited in vivo...
Bigley RF, Gibeling JC, Stover SM, Hazelwood SJ, Fyhrie DP, Martin RB.Volume effects are a fundamental determinant of structural failure. A material exhibits a volume effect if its failure properties are dependent on the specimen volume. Many brittle ceramics exhibit volume effects due to loading a structure in the presence of "critical" flaws. The number of flaws, their locations, and the effect of stress field within the stressed volume play a role in determining the structure's failure properties. Since real materials are imperfect, structures composed of large volumes of material have higher probabilities of containing a flaw than do small volumes. Consequen...
Newlyn HA, Collins SN, Cope BC, Hopegood L, Latham RJ, Reilly JD.A finite element model of donkey hoof wall was constructed from measurements taken directly from the hoof capsule of the left forefoot. The model was created with a 2 mm mesh and consisted of 11,608 nodes. A linear elastic analysis was conducted assuming isotropic material properties in response to a 375 newton (N) load, to simulate static loading. The load was applied to the wall via 400 laminae in order to simulate the way in which the pedal bone is suspended within the donkey hoof capsule. Displacement, stress concentration, principal strain, and force distribution across the hoof wall were...
Les CM, Stover SM, Keyak JH, Taylor KT, Willits NH.The distribution of material properties within the equine third metacarpal bone (MC3), and its possible effect on the mechanics of the structure, was quantitatively evaluated using single-load-to-failure compressive materials testing of specimens from ten horses. Bone samples from six regions within five proximodistal levels of MC3 were milled into right cylinders and compressed at a strain rate of 0.01 s-1. Diaphyseal MC3 bone material was stiffer, stronger, deformed less to yield and failure, and absorbed more energy to yield, than metaphyseal cortical bone material. Lateral and medial MC3 c...
Sanders RE, Kearney CM, Buckley CT, Jenner F, Brama PA.To evaluate knot security for 3 knot types created in 3 commonly used 5 metric suture materials incubated in physiological and pathological fluids. Methods: In vitro mechanical study. Methods: Knotted suture loops (n = 5/group). Methods: Loops of 3 different suture materials (glycolide/lactide copolymer; polyglactin 910; polydioxanone) were created around a 20 mm rod using 3 knot types (square [SQ], surgeon's [SK], and triple knot [TK]) and were tested to failure in distraction (6 mm/min) after tying (day 0) and after being incubated for 14 and 28 days in phosphate buffered saline (PBS...
Becker CK, Savelberg HH, Barneveld A.The material properties of the accessory ligament of the deep digital flexor tendon (AL) of 21 forelimbs from horses between ages one day and 15 years were determined. The force (634-11416 N), failure stress (45-138 N/mm2), failure strain (7-24%) and tangent modulus (33-1639 MPa) are presented in relation to age. Tangent modulus did not indicate changes in elasticity due to age. The results demonstrate that complete ligament failures (CLF) of ALs of older horses (mean 7835 N) occur at lower forces than ALs of young adult horses (mean 8894 N). Sudden decreases, 'dips', in the force-time curves ...
Mao J, Rassoli A, Tong Y, Rouse EN, Le-Bel G, How D, Germain L, Fatouraee N, Zhang Z, Reed RR, Guidoin R.Transcatheter aortic valve implantation (TAVI) has gained considerable acceptance in the past decade due to its lower risks than conventional open-heart surgery. However, the deformation and delamination of the leaflets during the crimping procedure have raised questions about the durability and long-term serviceability of the pericardium tissue from which the leaflets are made. The collagen architecture, wall thickness and mechanical properties of donkey pericardium were investigated to assess its suitability as an alternative material for the manufacture of heart valves. Coupons sampled from...
Du H, Yousefian O, Horn T, Muller M.The mode-converted (longitudinal to transverse, L-T) ultrasonic scattering method was utilized to characterize the structural anisotropy of a phantom mimicking the structural properties of trabecular bone. The sample was fabricated using metal additive manufacturing from high-resolution computed tomography (CT) images of a sample of trabecular horse bone with strong anisotropy. Two focused transducers were used to perform the L-T ultrasonic measurements. A normal incidence transducer was used to transmit longitudinal ultrasonic waves into the sample, while the scattered transverse signals were...
Peterson ML, Srinath S, Murphy J.A new instrument is presented which is capable of high resolution acoustic imaging at relatively low frequencies. This approach results in increased complexity of the signal processing required and reduced throughput of the instrument. However, these disadvantages are amply compensated by the ability to create velocity scan images of materials with either high attenuation or low material velocities. These measurements are not possible using traditional/acoustic microscopes. The initial performance of the new instrument is demonstrated using thin samples of shim materials to show that acceptabl...
Collier MA, Lowe JE, Rendano VT.Materials fatigue and gross biocompatability of an implantable bone growth stimulator (BGS) were assessed in a 6-month trial using 6 ponies. The forelegs of each pony were implanted with a BGS; the right leg implant had the cathode and cathode lead preconnected by the manufacturer, and the left leg implant was connected at surgery. Evaluation was by radiographic and clinical examination at the beginning and end of the experimental period. Six of the 12 cathode leads (50%) and 7 of the 12 cathodes (58%) were broken at 6 months. All of the implanted preconnected cathode and insulated cathode lea...
Wullschleger L, Weisse B, Blaser D, Fürst AE.Four radii of different horses were tested in three-point bending and in pure torsion. Detailed finite element (FE) models of these long bones were established by means of computed-tomography (CT) images and tests simulated for both load cases. For the allocation of the local isotropic material stiffness, individual exponential functions were applied whose factor and exponent were determined solely by fitting them to the measured torsional stiffness and bending stiffness of the entire bones. These stiffness functions referring directly to the CT number and having exponents between 1.5 and 2 we...
Listoni AJ, Arruda I, Maia L, Barberini DJ, Martins I, Vasconcellos FC, Landim-Alvarenga FC.Nanotechnology techniques have a prominent role in the current technical and scientific scene. The layer-by-layer (LbL) deposition allows obtaining nanostructures with sophisticated multilayer, using a simple, but versatile technique. This procedure, which is used to coat and functionalize surfaces with nanometer- thick films, has applications in bioengineering, medicine, chemistry, materials and chemical engineering among other areas. Chitosan is a biomaterial, coming from the chitin, a very abundant polymer in nature, which has been recently tested as scaffolds. In this experiment we test th...
Brandstetter J, Stanek C, Hinterhofer C.The use of handmade particulate reinforced alloy horseshoes (MMC metal matrix composites) was tested in a field study on 15 riding and draught horses. All horseshoes have been tempered after having been manually forged and tested concerning their surface imperfection. Forging temperature ranged between 350 degrees and 420 degrees C. Horseshoes in series A consisted of particulate reinforced wrought alloy (22% Al2O3 in alloy matrix). 11 shoeing periods with a duration of mean = 49.7 days (sd = 13.6) were evaluated. Horseshoes in series B consisted of particulate reinforced foundry alloy (20% Si...
Barrett EJ, Munsterman AS, Hanson RR, Jackson RL.To compare in vitro strength and failure characteristics of a tendon implant against a 3 loop pulley suture pattern for equine superficial digital flexor tendon (SDFT) laceration repair. Methods: Experimental. Methods: Cadaveric equine forelimb SDFT (n = 16). Methods: One tendon of each of 8 pair of SDFT was randomly selected for repair with either the 3-loop pulley (3LP) suture pattern using 2 polydioxanone or with 4 stainless steel suture and anchor implants (SA). Ultimate load to failure, mode of failure, gap at failure, and load to 2 mm gap were obtained using a materials testing sys...
Kasapi MA, Gosline JM.Small-scale components of the equine hoof wall were tested to determine their mechanical roles in the morphological hierarchy. Macroscale tensile tests conducted on samples of the inner wall tubules and intertubular material showed a sixfold difference in mean initial stiffnesses (0.47 and 0.08 GPa, respectively), indicating that the inner wall tubules stiffen the wall along its longitudinal axis. The similarity in material properties of tubule and intertubular samples from the mid-wall suggests that tubules in this region offer only minor reinforcement along the longitudinal axis. Microscale ...