Analyze Diet

Topic:Reproducibility of Results

Reproducibility of results in equine research refers to the ability to consistently replicate study findings when experiments are repeated under the same conditions. This concept is fundamental in scientific research, as it ensures the reliability and accuracy of experimental outcomes. In equine studies, reproducibility is influenced by various factors, including experimental design, sample size, and the biological variability of horses. Challenges in achieving reproducibility can arise from differences in horse breeds, age, health status, and environmental conditions. This page assembles peer-reviewed research studies and scholarly articles that explore methodologies, statistical approaches, and case studies related to reproducibility in equine research, highlighting its importance in advancing equine science and improving research practices.
Repeatability of 2 methods for assessment of insulin sensitivity and glucose dynamics in horses.
Journal of veterinary internal medicine    December 17, 2005   Volume 19, Issue 6 883-888 doi: 10.1892/0891-6640(2005)19[883:romfao]2.0.co;2
Pratt SE, Geor RJ, McCutcheon LJ.Both the euglycemic-hyperinsulinemic clamp (EHC) and minimal model analysis of the frequently sampled intravenous glucose tolerance test (FSIGT) have been applied for measurement of insulin sensitivity in horses. However, no published data are available on the reproducibility of these methods. Therefore, the objective of this study was to evaluate the variation and repeatability of measures of glucose dynamics and insulin sensitivity in horses derived from minimal model analysis of the FSIGT and from the EHC method. Six healthy horses underwent both the FSIGT and EHC on 2 occasions over a 4-we...
[Precision-controlled echocardiographic left ventricular function parameters by repeated measurement on three consecutive days in trained and untrained warmblood horses].
DTW. Deutsche tierarztliche Wochenschrift    March 25, 2005   Volume 112, Issue 2 48-54 
Gehlen H, Marnette S, Rohn K, Kreienbrock L, Stadler P.Echocardiographic measurements have to be reliable and reproducible with only a low day to day variability for detecting pathological changes of left ventricular myocardial function in horses. The day dependent fluctuation margin represents an important indicator for the reproducibility of a method. To find out the day to day variability of echocardiographic parameter in healthy warmblood horses, in the present study repeated echocardiographic measurements at three consecutive days were carried out (at the same time and by the same examiner) at 11 untrained and 7 trained warmblood horses. The ...
Observer variation in visual assessment of forelimb horseshoe characteristics on Thoroughbred racehorses.
American journal of veterinary research    January 6, 2005   Volume 65, Issue 12 1674-1679 doi: 10.2460/ajvr.2004.65.1674
Gross DK, Stover SM, Hill AE, Gardner IA.To assess the accuracy and reliability of a visual method of evaluating horseshoe characteristics. Methods: 1,199 Thoroughbred racehorses. Methods: Characteristics of 1 forelimb horseshoe were visually assessed on horses immediately prior to racing by 5 field observers at 5 major racetracks in California. Characteristics evaluated included horseshoe type; toe grab height; and the presence of a rim, pad, and heel traction devices. Sensitivity and specificity for observer assessment of horseshoe characteristics were calculated by comparing observer assessments to a postmortem laboratory standard...
Reproducibility of a locomotor test for trotter horses.
Veterinary journal (London, England : 1997)    August 11, 2004   Volume 168, Issue 2 160-166 doi: 10.1016/S1090-0233(03)00109-6
Leleu C, Bariller F, Cotrel C, Barrey E.Locomotion analysis is increasingly used to assess the gait of horses in the selection and training of equine athletes. We have developed a specific locomotor test for fast trotting harnessed horses that uses an accelerometric device. We describe here the reproducibility of the locomotor test and the validation of its use to analyse trotters on the racetrack. We measured the performance of eight horses under the same conditions three times in a single week. We then tested the influence of five tracks on the variables measured using eight different trotters every two days. The horses trotted at...
Reliability and repeatability of thermographic examination and the normal thermographic image of the thoracolumbar region in the horse.
Equine veterinary journal    May 28, 2004   Volume 36, Issue 4 306-312 doi: 10.2746/0425164044890652
Tunley BV, Henson FM.Thermographic imaging is an increasingly used diagnostic tool. When performing thermography, guidelines suggest that horses should be left for 10-20 mins to 'acclimatise' to the thermographic imaging environment, with no experimental data to substantiate this recommendation. In addition, little objective work has been published on the repeatability and reliability of the data obtained. Thermography has been widely used to identify areas of abnormal body surface temperature in horses with back pathology; however, no normal data is available on the thermographic 'map' of the thoracolumbar region...
Repeatability of standard transthoracic echocardiographic measurements in horses.
Australian veterinary journal    August 3, 2002   Volume 80, Issue 6 362-370 doi: 10.1111/j.1751-0813.2002.tb14790.x
Kriz NG, Rose RJ.To assess the repeatability of commonly employed transthoracic echocardiographic measurements in standing horses. Methods: Thirteen healthy 3- to 4-year-old fit Standardbred geldings with a mean weight of 411 (SEM +/- 10) kg were studied. The horses' environment, feeding and management regimens were standardised. All measurements were performed by the same investigator at the same time every day for three consecutive days. Methods: Standard transthoracic measurements were made on all horses. Each measurement was performed over three consecutive cardiac cycles on 1 day and all measurements were...
Repeatability of diagnostic ultrasonography in the assessment of the equine superficial digital flexor tendon.
Equine veterinary journal    February 24, 2001   Volume 33, Issue 1 33-37 doi: 10.2746/042516401776767494
Pickersgill CH, Marr CM, Reid SW.A quantitative investigation of the variation that can occur during the course of ultrasonography of the equine superficial digital flexor tendons (SDFT) was undertaken. The aim of this investigation was to use an objective measure, namely the measurement of CSA, to quantify the variability occurring during the course of the ultrasonographic assessment of the equine SDFT. The effects of 3 variables on the CSA measurements were determined. 1) Image acquisition operator (IAc): two different operators undertaking the ultrasonographic examination; 2) image analysis operator (IAn): two different op...
An in vitro study to compare 5 different techniques for injection of the navicular bursa in the horse.
Equine veterinary journal    June 3, 2000   Volume 32, Issue 3 263-267 doi: 10.2746/042516400776563635
Schramme MC, Boswell JC, Hamhougias K, Toulson K, Viitanen M.Numerous different techniques for injection of the navicular bursa have been described but there is little conformity between these descriptions. A literature review was performed and techniques for injection of the navicular bursa were categorised into 5 approaches. This study was performed to evaluate the reproducibility of each technique and to assess which technique was consistently most successful. Five inexperienced operators performed each technique on 5 cadaver forelimbs. Once a needle had been placed, a radiograph was taken to confirm placement was in accordance with the description o...
Determination of testosterone:epitestosterone ratio after pentafluorophenyldimethylsilyl-trimethylsilyl derivatisation using gas chromatography-mass spectrometry in equine urine.
The Analyst    January 5, 2000   Volume 124, Issue 5 675-678 doi: 10.1039/a901242g
Choi MH, Kim JY, Chung BC.A highly specific method is described for measuring the testosterone:epitestosterone ratio in equine urine by gas chromatography-mass spectrometry (GC-MS) with stable isotope internal standards. The procedure was based on Serdolit Pad-1 resin extraction, enzymatic hydrolysis, and chemical derivatisation prior to instrumental analysis. The mixed derivatives, 3-trimethylsilyl-17-pentafluorophenyldimethylsilyl ether (3-TMS-17-flophemesyl) testosterone and epitestosterone, were found to have excellent analytical properties. The specificity of the derivatisation method exploits a unique feature of ...
Evaluation of a haematological analyser (Sysmex F-800) with equine blood.
Zentralblatt fur Veterinarmedizin. Reihe A    May 20, 1998   Volume 45, Issue 2 119-126 doi: 10.1111/j.1439-0442.1998.tb00807.x
Pastor J, Cuenca R, Velarde R, Marco I, Viñas L, Lavín S.A semiautomatic electronic blood cell counter (Sysmex F-800) was evaluated with equine blood, according to the protocol of the International Committee for Standardization in Haematology (ICSH, 1984). The precision and overall reproducibility were acceptable for all the parameters studied except for the platelet count, in which a coefficient of variation of 18.8% and 21.7% was obtained for within and between batch precision and 26.76% for overall reproducibility. Carry-over for the haematocrit value and platelet count was unsatisfactory, thus the use of a blank diluent sample between different ...
Variability of the limb joint patterns of sound horses at trot.
Equine veterinary journal. Supplement    May 1, 1997   Issue 23 89-92 doi: 10.1111/j.2042-3306.1997.tb05062.x
Degueurce C, Pourcelot P, Audigié F, Denoix JM, Geiger D.The reproducibility of gait variables for sound horses is essential for the interpretation of their modifications by locomotor disorders. Therefore, the purpose of this study was to evaluate the variability of the limb joint angle patterns in a population of sound horses while they trotted in the conditions of the routine lameness examination (slow trot, just held by hand, on a track, outdoors). The kinematics of 14 French Saddle horses was recorded using a 3-dimensional (3D) kinematic analysis system. Angle-time diagrams were established in the sagittal plane and their intra- and inter-indivi...
Linear assessment of the thoroughbred horse: an approach to conformation evaluation.
Equine veterinary journal    November 1, 1996   Volume 28, Issue 6 461-467 doi: 10.1111/j.2042-3306.1996.tb01618.x
Mawdsley A, Kelly EP, Smith FH, Brophy PO.A linear assessment trait evaluation system is proposed to allow quantitative description of the static conformation of the horse. Measurements were made on 27 selected traits. The system was tested initially for repeatability of measurements on 4 horses. Twenty-one of the selected traits were satisfactory and 6 proved unsatisfactory in terms of reproducibility. A population of 101, superior 2- and 3-year-old Thoroughbreds and 19 premium Thoroughbred stallions were similarly assessed. More than 65% of the traits exhibited large (CV > 10%) phenotypic variation within the sampled population. ...
Measurements of urethral pressure profiles in the male horse.
Equine veterinary journal    January 1, 1994   Volume 26, Issue 1 55-58 doi: 10.1111/j.2042-3306.1994.tb04332.x
Ronen N.Urinary tract pressure profiles were evaluated in 6 clinically normal geldings over 3 consecutive days. This was performed by introducing a 1.3 m-long cuffed catheter into the urinary tract, under xylazine sedation (0.8 mg/kg, iv). The method was reproducible. The mean (+/- sd) intra-vesicular pressure (IVP) and maximal urethral closure pressures (MUCP) were 10.3 (+/- 1.7) and 129.8 (+/- 19.6) cmH2O, respectively, and the ratio between MUCP and IVP was 13.2 (+/- 2.5). A gelding with urinary incontinence showed a significantly lower MUCP (73.4 cmH2O), and an MUCP to IVP ratio of 8.0. It was con...
A method to estimate the initial length of equine tendons.
Acta anatomica    January 1, 1993   Volume 146, Issue 2-3 120-122 doi: 10.1159/000147432
Riemersma DJ, van den Bogert AJ.A procedure is described by which the length of a tendon at the onset of loading is determined objectively. The procedure includes the fitting of third-order polynomial functions on the load-elongation data. The onset of loading is detected by an increasing fit of the polynomial by selective data reduction of the initial part of the load-elongation curve. The procedure results in an objective and reproducible definition of the zero strain level of a tendon.
Reproducibility and the influence of age on interspecimen determinations of blood pressure in the horse.
Comparative biochemistry and physiology. A, Comparative physiology    January 1, 1983   Volume 74, Issue 1 11-20 doi: 10.1016/0300-9629(83)90704-1
Ostlund C, Pero RW, Olsson B.1. The reproducibility of blood pressure determinations on 103 male horses gave an average coefficient of variation of 5.0%. 2. Different parameters affecting the methodology of blood pressure measurements were separately analysed; i.e. size of specimen, size of cuff in relationship to tail circumference and temperature of the environment. 3. A strong positive linear correlation between age and blood pressure in the horse was established for two breeds with widely varying genetic background--Swedish Warmbloods and Arabians.
Volume dilution of sodium thiocyanate as a measure of extracellular fluid volume in the horse.
American journal of veterinary research    April 1, 1979   Volume 40, Issue 4 587-589 
Carlson GP, Harrold D, Rumbaugh GE.Volume dilution of sodium thiocyanate as a measure of extracellular fluid volume was determined in 24 normal adult horses and 4 ponies. The method employed yielded highly reproducible results on multiple determinations in individual horses. A highly significant (P less than .001) correlation between thiocyanate space and body weight was demonstrated.