Treadmill exercise for horses involves the use of a controlled mechanical platform to simulate various gaits and intensities of physical activity. This form of exercise allows for consistent and measurable training conditions, which can be used for rehabilitation, fitness assessment, and performance enhancement. Treadmill exercise facilitates the study of equine locomotion, respiratory function, and cardiovascular response under standardized conditions. It is also utilized in research to evaluate the effects of different training regimens and to investigate metabolic and physiological responses to exercise. This page compiles peer-reviewed research studies and scholarly articles that explore the methodology, applications, and implications of treadmill exercise in equine practice.
Stanek KA, Nagle FJ, Bisgard GE, Byrnes WC.Published reports of oxygen consumption (VO2) during exercise in hyperoxia are equivocal. By and large, when measured at the lung using respiratory gas equations, VO2 is elevated in hyperoxia and, when measured at the blood-tissue level using the cardiovascular Fick (CVF) equation, it is unchanged. We sought to provide some insight into this problem by making through the use of both equations simultaneous determinations of VO2 during hyperoxia in exercising ponies. In normoxia, during treadmill exercise (115 m/min, 10% grade) of seven ponies, there was no difference in exercise VO2, whether it...
Bisgard GE, Forster HV, Byrnes B, Stanek K, Klein J, Manohar M.Ventilation, metabolism, arterial blood gases, and blood and cerebrospinal fluid (CSF) acid-base status were measured in exercise studies on seven ponies during mild, moderate, and near-maximal treadmill exercise. CSF and arterial blood were sampled via indwelling catheters. Generally measurements were made during the 3rd, 6th, and 9th minute of steady-state exercise, with CSF sampled only during the 9th minute. Alveolar ventilation (VA) and metabolic rate (VO2) increased proportionately during exercise below the anaerobic threshold, but above this threshold, VA increased at a faster rate than...
Hill G, Atkins R, Littlejohn A, Kruger JM, Bowles F.A robust low cost portable radiotelemetry system is described for the horse and its method of operation and advantages briefly discussed. The equipment consisted of 2 electrodes forming a bipolar lead, a transmitter, a receiver and a writing device. The sitting, application and immobilising of the electrodes was a most important factor in obtaining good quality recordings. ECGs were recorded at all paces and also while jumping and the results proved satisfactory.
Steel JD, Hall MC, Stewart GA.Changes that occur in the equine ECG during and after exercise have been described and compared with resting ECG's obtained from the same horses. When the speed of work equals or is greater than "three-quarter pace" (i.e. "even time" or 200 metres in 15 seconds) the high heart rates developed cause the loss of ECG waveforms that are readily discernible at rest. Although differences in the waveforms between horses with normal and abnormal resting ECG's have been observed, the more definitive useful information is the fact that abnormal horses showed significantly higher heart rates than normal ...
Campos Schweitzer A, Mespoulhes-Rivière C, Perkins JD, Ducharme NG, Piercy RJ, Lynch N, Rossignol F.To evaluate functional and histopathologic outcomes of standing selective laryngeal reinnervation using the spinal accessory nerve (SAN) in horses with experimentally induced recurrent laryngeal neuropathy (RLN). Methods: Five Thoroughbred mares. Methods: Prospective cohort study. Methods: The horses underwent left recurrent laryngeal neurectomy followed 8 weeks later by selective laryngeal reinnervation using the SAN. Follow-up evaluations at 4.5, 6, 8, and 12 months included treadmill exercising endoscopy, ultrasonography of intrinsic laryngeal muscles, and percutaneous electrical stimul...
Nascimento C, Braz AL, Barbosa I, Freire G, Nicolau M, Silvestre F, Filho HM, Simões J, Estepa JC, Clayton H, Coelho C.This study aimed to investigate cardiac adaptations and energy expenditure of jumping horses after water treadmill (WT) training. Six trained horses were evaluated before (PRETR) and after (TR) a WT training (20 min, twice/week, water at carpus height) for 10 weeks. Transthoracic echocardiography was performed at PRETR and TR with phased array transducer (1.9-4 MHz) to obtain interventricular septal thickness (IVS), LV internal diameter (LVID), and posterior wall thickness (LVPW) at end-diastole (d) and systole (s) and heart rate (HR). Left ventricule end diastolic volume (Vd) and end syst...
Tranquille C, Nankervis K, Tacey J, Hopkins E, Deckers I, Walker V, MacKechnie-Guire R, Newton R, Murray R.Water treadmill (WT) exercise has become a popular tool for equine training and rehabilitation. However, few studies describe the long-term effects of WT exercise in low water on muscle development (MD). This study's objectives were to compare MD changes over a 40-week period in sport horses that regularly used WT in low water within training (Group WTH, = 55) and a control group that did not (control, = 28). Subjective MD assessments were undertaken using an adaptation of a previously published method at weeks 0, 20 and 40. For Group WTH, MD significantly increased in the neck, pelvis and h...
Marlin D, Randell O, Mayhew E, Blake R.The aim of this study was to investigate the effect of girth design and girth tension; six horses regularly ridden were used. Each horse underwent four experimental sessions in an unbalanced Latin-square design with two girth tensions (8 kg or 16 kg) and two girth designs (straight girth (S) or anatomical girth (A)). Pressure between the saddle and the horse was measured at 100 Hz with a pressure mat (0.5 sensels per cm). Notably, 2D limb kinematics were determined from anatomical markers placed on the fore and hindlimbs. Video was collected at 240 fps. There was no significant effect of girth...
Söderroos D, Stefánsdóttir GJ, Ragnarsson S, Gunnarsson V, Jansson A.Weight-carrying capacity is important in riding horses both for performance and welfare, yet there is no standardized method to estimate individual horses' weight-carrying capacity. This study investigated the correlation between the physiological response during a (i) standardized incremental exercise test (SET) on a treadmill and a (ii) ridden incremental weight-carrying exercise test (WET). Sixteen horses (15 ± 3 years) performed both tests, including four steps with increased speed or weight load, respectively. Body weight ratio (BWR) in the WET was 20%, 25%, 30%, and 35% in each st...
Jeong S, Bond S, Bayly W, Sole-Guitart A.To quantify the impact of experimentally induced dorsal nasopharyngeal collapse (NPC) on respiratory performance parameters and assess the efficacy of laser fenestration of the dorsal pharyngeal recess as a treatment option for experimentally induced NPC. Methods: Experimental interventional study. Methods: Six adult Standardbreds (one with naturally occurring disease). Methods: After an 8 week conditioning program, baseline parameters (V̇Omax, pharyngeal pressure, peak airflows, upper airway resistance) and dynamic endoscopy videos were collected in a high-speed treadmill test (T1). Dorsal N...
Hammack SM, Moshage SG, Kersh ME, McCoy AM.To quantify circulating levels of myokines with a known role in bone remodeling (receptor activator of nuclear factor κ B ligand [RANK-L], matrix metalloproteinase 2 [MMP-2], and irisin) in foals in response to exercise and over the first year of life. Unassigned: 12 foals were enrolled in the study; 6 underwent an 8-week exercise program, and 6 were nonexercised controls. Blood samples were collected between 2 and 11 months of age. Receptor activator of nuclear factor κ B ligand, MMP-2, and irisin were quantified using equine-specific ELISAs. Unassigned: RANK-L, MMP-2, and irisin did not ch...
Sande A, Santosuosso E, Scharf JE, Shoemaker SJ, Temple S, Hemmerling K, Kell T, Leguillette R, Bayly WM.To compare maximal lactate steady-state (MLSS) speeds determined using a treadmill-dependent invasive reference method (RM) with 2 noninvasive methods based on heart rate variability-focused analysis of exercise ECGs. Unassigned: This was a randomized, blinded study using 7 fit Thoroughbreds. A standardized incremental exercise treadmill test (SET) where blood lactate concentration ([La]) was measured after every step facilitated calculation of speeds at which [La] was 1.5, 2.0, and 2.5 mmol/L. The RM required steady-state exercise (SS) at each of these speeds for 25 minutes or until [La] incr...
St George L, Nankervis K, Walker V, Maddock C, Robinson A, Sinclair J, Hobbs SJ.Despite growing evidence on the adaptive movement patterns that horses adopt during water treadmill (WT) exercise, underlying adaptations in muscle activity remain uninvestigated. This feasibility study aimed to develop a method for the synchronous measurement of muscle activity and movement of horses during WT exercise. Combined surface electromyography (sEMG) (2000 Hz) from selected hindlimb (biceps femoris, gluteus medius, tensor fasciae latae) and epaxial (longissimus dorsi) muscles, and three-dimensional kinematic (200 Hz) data from the back and pelvis of one (n = 1) horse were collected ...
Littiere TO, da Costa GB, de Sales NAA, de Carvalho JRG, Rodriguez IDM, Ramos GV, de Lacerda-Neto JC, Ferraz GC.Maximal lactate steady state (MLSS) and its predictive thresholds, including the lactate threshold (LT), are widely used to estimate endurance capacity, prescribe training, and assess the effects of training. The human literature identified approximately twenty-five methods to predict the MLSS. This communication compares the concordance between the two D methods and the MLSS. Under laboratory conditions, ten teaching horses underwent a submaximal graded exercise test (GXT) on a treadmill to obtain their lactate-velocity curves (LVC). They performed three to five 30-min continuous running sess...
Key K, Berg K, Kirkegaard J, Andresen KR, Hansen SS.Equine lameness diagnosis largely relies on subjective visual assessments, which can be biased. Although marker-based methods, force plates and inertial measurement units (IMUs) provide objective measurements, they require specialized setups. Vision-based algorithms offer a portable, markerless alternative, but their accuracy needs thorough testing. Objective: To evaluate a custom vision-based algorithm for estimating the groundline across multiple camera angles, including handheld use in horses trotting on a treadmill. Methods: Experimental comparative study. Methods: Eight Standardbred trott...