Journal of veterinary cardiology : the official journal of the European Society of Veterinary Cardiology.
Publisher:
European Society of Veterinary Cardiology. Amsterdam : Elsevier (2005)
Frequency: Four no. a year, 2011-
Country: Netherlands
Language: English
Author(s):
European Society of Veterinary Cardiology.
Start Year:1999 -
ISSN:
1760-2734 (Print)
1875-0834 (Electronic)
1760-2734 (Linking)
1875-0834 (Electronic)
1760-2734 (Linking)
Impact Factor
1.2
2022
| NLM ID: | 101163270 |
| (OCoLC): | 48970289 |
| LCCN: | 2002233044 |
| Classification: | W1 JO97LL |
Ventriculophasic response in a horse with atrioventricular block. Ventriculophasic response (VR) in atrioventricular nodal (AVN) block is characterized by a shortening of the sinoatrial cycle length when a QRS complex is interposed between two P waves. This has been well documented in humans and dogs with AVN blocks but not in horses. Herein, we describe a horse with second-degree AVN blocks and constant PR intervals that exhibited 5:3 conduction and suspected VR at rest but less consistently after submaximal exercise. Proposed VR mechanisms include (1) inhibition of the Bezold-Jarisch reflex from reduced end-systolic volume during ventricular contraction; (...
Detection of paroxysmal atrial fibrillation preceding persistent atrial fibrillation in a horse using an implantable loop recorder with remote monitoring. Implantable loop recorders (ILRs) are increasingly used in equine cardiology to detect arrhythmias in the context of collapse, poor performance or monitoring for recurrence of atrial fibrillation (AF). However to date, the ILR has never been reported to be used with a remote monitoring functionality in horses, therefore the arrhythmia is only discovered when a clinician interrogates the ILR using dedicated equipment, which might delay diagnosis and intervention. This case report describes the use of an ILR with remote monitoring functionality in a horse with recurrent AF. The remote monitoring...
Structural and electro-anatomical characterization of the equine pulmonary veins: implications for atrial fibrillation. Spontaneous pulmonary vein (PV) activity triggers atrial fibrillation (AF) in humans. Although AF frequently occurs in horses, the origin remains unknown. This study investigated the structural and electro-anatomical properties of equine PVs to determine the potential presence of an arrhythmogenic substrate. Methods: Endocardial three-dimensional electro-anatomical mapping (EnSite Precision) using high-density (HD) catheters was performed in 13 sedated horses in sinus rhythm. Left atrium (LA) access was obtained retrogradely through the carotid artery. Post-mortem, tissue was harvested from th...
Development of a three-dimensional computer model of the equine heart using a polyurethane casting technique and in vivo contrast-enhanced computed tomography. Insight into the three-dimensional (3D) anatomy of the equine heart is essential in veterinary education and to develop minimally invasive intracardiac procedures. The aim was to create a 3D computer model simulating the in vivo anatomy of the adult equine heart. Methods: Ten horses and five ponies. Methods: Ten horses, euthanized for non-cardiovascular reasons, were used for in situ cardiac casting with polyurethane foam and subsequent computed tomography (CT) of the excised heart. In five anaesthetized ponies, a contrast-enhanced electrocardiogram-gated CT protocol was optimized to image th...
Diagnostic value of two-dimensional echocardiographic measurements of the pulmonary artery diameter and the pulmonary artery distensibility index to detect pulmonary hypertension in horses. Echocardiographic diagnosis of pulmonary hypertension (PH) in horses is usually based on Doppler interrogation of tricuspid (TR) or pulmonic regurgitation (PR). This study aimed at investigating two-dimensional echocardiographic (2DE) variables, including pulmonary artery diameter (PAD) and pulmonary artery distensibility index (PADI), to diagnose PH. Methods: 41 healthy horses; 82 horses with TR or PR and normal intracardiac pressure gradients; and 35 horses with TR or PR velocities indicating PH. The 2DE variables were compared between groups, cut-offs for the diagnosis of PH were determined...
Cardiovascular changes in horses with atrial fibrillation and high thyroid hormone concentration: a case-control study. Hyperthyroidism is a predisposing factor for atrial fibrillation (AF) in humans. The relationship between high thyroid hormone (TH) and AF in horses has not been evaluated. Objective: The aim of this study is to identify whether (1) high TH concentrations were present in horses with AF, (2) other cardiovascular effects were observed in horses with high TH and AF, and (3) TH status affected recurrence rate. Methods: Twenty-three horses presented with naturally occurring AF. Methods: Prospective case-control clinical study. Thyroid hormone concentration was measured in horses presenting with AF....
Feasibility and clinical utility of transvenous intracardiac echocardiography in conscious, sedated horses. Intracardiac echocardiography (ICE) is a method of obtaining echocardiographic images with a steerable ultrasound catheter placed within the heart via a venous or arterial approach. The objectives of this study were to assess the feasibility of a 5-10 MHz, 8 French, 90 cm ICE catheter to evaluate cardiac structures and function in standing, sedated horses, and describe standard views in this species. Methods: Ten apparently healthy horses weighing 458.1-618.2 kg from a university teaching herd. Methods: Each horse had a physical examination, transthoracic echocardiography, and ICE performe...
Heritability estimates of atrial fibrillation in Thoroughbred racehorses in Hong Kong and Australia. Atrial fibrillation (AF) is the most common performance-limiting arrhythmia of racehorses. A genetic contribution has been suggested in Standardbred racehorses but has not been investigated in Thoroughbreds. The objective of this study was to determine the heritability of AF in Thoroughbred racehorses. Methods: Horses racing between 2007 and 2019 in Hong Kong and Australia that had AF detected postrace via auscultation (n = 463 cases) were compared with five randomly selected racing contemporaries (n = 2,315 controls). The ASReml-R programme was used to fit an animal model to the AF data t...
Balloon valvuloplasty of valvular pulmonary stenosis in a neonatal foal. In a 1-day old filly with a loud heart murmur, transthoracic echocardiography revealed right ventricular hypertrophy associated with severe pulmonary valvular stenosis and a transvalvular pressure gradient (between right ventricle and pulmonary artery) of 125 mmHg. Computed tomographic angiography confirmed the finding, with no evidence of other relevant concurrent abnormalities. Balloon valvuloplasty was performed using a single balloon technique. The foal recovered well from anaesthesia. Following the procedure, the right ventricle-pulmonary artery transvalvular gradient decreased to 38 mm...
Quantification of left atrial contractile function using two-dimensional speckle tracking echocardiography in horses after conversion of atrial fibrillation to sinus rhythm. In horses, persistent atrial dysfunction is a prognostic indicator of recurrence of atrial fibrillation (AF). The objective of this study was to quantify left atrial (LA) contractile function in Warmblood horses after successful cardioversion of AF to sinus rhythm, using standard two-dimensional echocardiography (2DE) and two-dimensional speckle tracking (2DST) analyses, and to provide proof-of-concept for use of 2DST to detect LA contractile dysfunction in horses. Methods: Nineteen Warmblood horses with AF and successful transvenous electrical cardioversion (TVEC) or medical cardioversion usi...
Effect of racing on cardiac troponin I concentration and associations with cardiac rhythm disturbances in Standardbred racehorses. Accumulating evidence indicates intense exercise can be associated with myocardial damage. Investigating the impact of maximal effort on myocardium and exploring possible association of injury with rhythm disturbance requires a high-sensitivity cardiac troponin assay. The objectives of this study were: (1) to determine the effect of racing on serum cardiac troponin I (cTnI) in Standardbred horses using a high-sensitivity assay; (2) to determine the 99th percentile of cTnI in healthy horses and investigate the effect of demographic variables on cTnI prevailing pre-race in Standardbred horses us...
Relationship between atrial fibrillatory rate based on analysis of a modified base-apex surface electrocardiogram analysis and the results of transvenous electrical cardioversion in horses with spontaneous atrial fibrillation. To compare the atrial fibrillatory rate (AFR) derived from a local right atrial intracardiac recording (RA-FR) and from a single-lead surface electrocardiogram (ECG) during atrial fibrillation (AF) and to evaluate the correlation with transvenous electrical cardioversion (TVEC) threshold (in Joules), number of shocks and cardioversion success rate in horses. Methods: ECGs and clinical records of horses with AF treated by TVEC. Horses were included if a simultaneous recording of the right atrial intracardiac electrogram and a modified base-apex ECG were available. Methods: Clinical records of h...
Evaluation of a novel ambulatory electrocardiogram monitor (the Carnation Ambulatory Monitor) for use in horses. Short-term electrocardiogram (ECG) examinations of horses may not detect paroxysmal arrhythmias. Twenty-four hour Holter equipment can be unwieldy and inconvenient for long-term use. This study evaluated a novel long-term ECG patch recorder, the Carnation Ambulatory Monitor (CAM) in horses, determining ideal placement, practicality, durability and performance. Methods: Twenty-one adult mixed-breed horses. Methods: Prospective observational study. Three horses had ECG patches fitted at selected sites (phase 1); the two most promising sites were used for further wear testing (phase 2) and the b...
Asymmetric dimethylarginine-A potential cardiac biomarker in horses. Asymmetric dimethylarginine (ADMA) is a cardiac biomarker in humans, symmetric dimethylarginine (SDMA) a renal biomarker in humans, cats, and dogs. The purpose of this prospective study was to investigate if measuring serum ADMA and SDMA concentrations via ELISA allows detection of cardiac disease in horses in a routine laboratory setting. In this context, reference values in horses were established. Methods: Seventy-eight horses with no known medical history were compared to 23 horses with confirmed structural cardiac disease with/or without arrhythmias. Horses underwent physical examination,...
Primary cardiac hemangiosarcoma in a horse: echocardiographic and necropsy findings. Cardiac hemangiosarcoma, especially primary, is infrequently reported in the horse and remains a diagnostic challenge because of vague clinical signs and difficulty to reach an antemortem diagnosis. A 17-year-old American Quarter Horse gelding was presented with a history of tongue swelling and secondary aspiration pneumonia. Initial assessment indicated dehydration, and thoracic ultrasound revealed an abnormal structure within the myocardium alongside the previously suspected aspiration pneumonia. A subsequent, complete echocardiogram identified a large, heterogeneous, ill-defined mass invadi...
Partial atrioventricular septal defect in an adult sport horse. A partial atrioventricular septal defect, represented as a large ostium primum atrial septal defect and common (bridging) atrioventricular valve leaflets with cleft septal leaflet of the mitral valve, was diagnosed incidentally in a nine-year-old warmblood gelding used for show jumping. Initial examination findings and a three-year follow-up are documented in this report. The horse was first presented for the evaluation of chronic coughing. A left-sided, grade 4/6 holosystolic (band-shaped) murmur was identified along with a similar right-sided, grade 3/6 heart murmur. Echocardiography reveale...
Quantification of left atrial wall motion in healthy horses using two-dimensional speckle tracking. The mechanical function of the left atrium (LA) plays a pivotal role in modulation of left ventricular filling. Assessment of LA function might be a clinically useful prognostic tool for horses with mitral regurgitation or atrial fibrillation. However, the most accurate, reliable, and clinically useful methods to assess LA myocardial function are yet to be determined. The objective of this study was to describe the methods for quantification of LA wall motion using two-dimensional speckle tracking (2DST) echocardiography in healthy Warmblood horses to quantify measurement variability, to calcu...
Two-dimensional, M-mode and left atrial velocity echocardiographic measurements in healthy Norwegian-Swedish Coldblooded Trotters. The Norwegian-Swedish Coldblooded Trotter (NSCT) is an important breed in Norwegian and Swedish harness racing. In spite of this, little is known about its cardiac measurements and factors that may influence these. The aims of this study were to establish reference intervals (RI) for a series of conventional echocardiographic variables, primarily of the left heart, in NSCTs in race training and to evaluate any effects age, gender, estimated body weight (EBW), number of starts and racing performance may have on these. Methods: Sixty-three apparently healthy NSCTs in race training. Methods: Obse...
Percutaneous transcatheter closure of an aorto-cardiac fistula in a six-year-old Warmblood mare with atrial fibrillation. This report describes a rare case of an aorto-cardiac fistula in a six-year-old French Warmblood mare presented with atrial fibrillation, decreased performance, ventral oedema, bounding arterial pulsation and pathological jugular venous pulse. A 2.7-cm-diameter fistula connected the right aortic sinus of Valsalva to the right atrium. Atrial fibrillation was likely due to volume overload of the right heart due to left-to-right shunting. The horse was treated by percutaneous transcatheter closure of the fistula delivered under general anaesthesia using a transarterial approach. The operation was...
Cardiovascular variables in eventing and endurance horses over a season. The objectives of this study were to describe the changes in clinical cardiovascular examination variables over a competition season in groups of competitive eventing and endurance horses and to compare these findings to non-competitive controls of the same breeds. Methods: This study included two eventing horses, 11 endurance horses, and 13 eventing and seven endurance control breed-matched horses. Methods: Cardiovascular examinations were performed before starting the competition season, in the middle and at the peak/end of the competition season. Examinations included auscultation of the he...
Cardiovascular images: vascular hamartoma of the mitral valve in a horse. An 8-month-old Hanoverian gelding was presented with a history of cardiac murmurs that were not apparent as a foal nor reported at the time of castration. Major echocardiographic findings included mitral valvular thickening, functional stenosis, and mitral regurgitation of sufficient severity to cause diastolic and systolic cardiac murmurs, left-sided volume overload, and pulmonary hypertension. Due to the hemodynamic severity of the lesion and poor prognosis for future performance and longevity, euthanasia was elected. On gross postmortem examination, there was focal fibrous epicarditis affec...
Electrocardiographic confirmation of a twin pregnancy in a mare at 8 months of gestation. A 15-year-old Warmblood mare, at 8 months of gestation, was presented to the Ghent University Faculty of Veterinary Medicine for evaluation of suspected stage one labor. Transrectal ultrasonography revealed no clear signs of placentitis or stage one labor. The combined thickness of uterus and placenta was 11 mm and the cervix was closed. Twin pregnancy was suspected by transabdominal ultrasonography but could not be confirmed with certainty. An electrocardiogram (ECG) was recorded from the mare's abdominal wall to register a fetal ECG. To confirm twin pregnancy, registration of both fetal ECG...
Plasma homocysteine concentrations in healthy horses and horses with atrial fibrillation. Homocysteine (HCY) is an amino acid produced from methionine metabolism. Plasma homocysteine concentrations ([HCY]p) are elevated (>13 μmol/L) in people with atrial fibrillation (AF) and can predict the recurrence of AF after cardioversion. This study aimed to validate a commercially available human HCY assay for use in horses to develop reference intervals for [HCY]p and compare [HCY]p in healthy horses and horses with AF. Methods: Healthy horses (n = 27) and horses with AF (n = 55, 34 of which were cardioverted using transvenous electrical cardioversion). Methods: Blood samples were a...
Investigation of ventricular pre-excitation electrocardiographic pattern in two horses: clinical presentation and potential causes. Two horses referred to the Unitat Equina, Fundació Hospital Clínic Veterinari, Universitat Autònoma de Barcelona, for unrelated clinical problems, and with no previous history of cardiac disease exhibited an intermittent ventricular pre-excitation electrocardiographic pattern during hospitalization. Both animals showed decreased plasma total and ionized magnesium concentrations, but no other relevant electrolyte disturbances were detected. Altered interventricular septal motion associated with ventricular pre-excitation beats (VPBs) was detected on M-mode echocardiography in both horses. Th...
Double outlet right ventricle with subpulmonary ventricular septal defect (Taussig-Bing anomaly) and other complex congenital cardiac malformations in an American Quarter Horse foal. A 4-week-old American Quarter Horse colt presented with a recent history of diarrhea and decreased activity level. On initial physical examination, the animal was bright and alert and major findings were limited to a loud systolic heart murmur radiating widely over both sides of the thorax. While in the hospital, the clinical condition of the foal warranted further imaging to determine the cause and extent of cardiac disease. A variety of congenital cardiac malformations were identified during echocardiographic examination and autopsy, including a double outlet right ventricle and a subpulmona...
Reference values of two-dimensional and M-mode echocardiographic measurements as a function of body size in various equine breeds and in ponies. The aim of this study was to establish echocardiographic reference values for the equine species using allometric regression equations based on body weight (BW) and thoracic circumference (TC). Methods: A total of 239 horses or ponies were studied, including 65 warmbloods, 33 Standardbreds, 41 Thoroughbreds, 32 Arabian horses, 28 draft horses, and 40 ponies aged from 1 day to 30 years, weighing from 18 to 890 kg, with no evidence of cardiac disease. Methods: For each horse or pony, a two-dimensional and M-mode echocardiography was performed. Within each breed, the relationships between BW or ...
Atrial fibrillation management in a breeding stallion. A 20-year-old warmblood breeding stallion presented to a University practice for semen collection and evaluation was incidentally diagnosed with atrial fibrillation (AF). Electrocardiogram recordings during breeding revealed inappropriately rapid tachycardia and occasional ventricular premature depolarizations/aberrant ventricular conduction. Transvenous electrical cardioversion was performed. After successful cardioversion the horse displayed supraventricular ectopy and atrial contractile dysfunction and was administered sotalol hydrochloride in an attempt to decrease the risk of AF recurrenc...
Influence of 2nd-degree AV blocks, ECG recording length, and recording time on heart rate variability analyses in horses. To assess the influence of 2nd-degree AV blocks (AVB) on RR interval-based heart rate variability (HRV) variables; to investigate the effect of using PP interval time series and of artifact filtering on HRV analyses; to investigate the influence of electrocardiogram (ECG) recording length and time of recording; and to calculate day-to-day variability and reference intervals of HRV variables. Methods: Thirty healthy adult horses. Methods: RR and PP interval time series were extracted from 10-h Holter ECGs and an automated filter was applied to the RR time series (RR). Time-domain HRV variables...
Transcutaneous direct current cardioversion in a foal with lone atrial fibrillation. There are rare published reports of atrial fibrillation (AF) in foals, all of which are associated with structural heart disease or within the adaptive period of newborns. This report describes a 3-month-old Thoroughbred filly with AF and a structurally normal heart on echocardiography. Medical cardioversion of the foal's AF was attempted with three 20mg/kg doses of quinidine sulfate therapy without success. Timed, transcutaneous, direct current cardioversion was successfully performed using adhesive patches on the midthorax in conjunction with intravenous procainamide at a total dose of 20mg/...
Pulmonary atresia with intact ventricular septum and hypoplastic right ventricle in an Arabian foal. Pulmonary atresia with intact ventricular septum, rudimentary tricuspid valve, hypoplastic right ventricle, and right-to-left atrial shunting were identified in a four-day-old, male Arabian foal with clinical signs of cyanotic heart disease. Pulmonary blood flow was apparently derived from a ductus arteriosus. Echocardiographic evaluation revealed the majority of cardiac abnormalities and also findings compatible with right-sided congestive heart failure. Congenital cardiac defects have a high incidence in this breed, and this is the first description of this combination of congenital cardiac ...