Veterinary and comparative orthopaedics and traumatology : V.C.O.T.

Periodical
Orthopedics
Traumatology
Veterinary Medicine
Wounds and Injuries
Wounds and Injuries
Publisher:
Schattauer,. Stuttgart : Thieme (2018)
Frequency: Six no. a year, 2009-
Country: Germany
Language: English
Start Year:1988 -
ISSN:
0932-0814 (Print)
2567-6911 (Electronic)
0932-0814 (Linking)
Impact Factor
1.3
NLM ID:8906319
(DNLM):SR0062059(s)
(OCoLC):18203645
LCCN:sn 89036281
Classification:W1 VE922
Mechanical Properties and Failure Mode of Proximal Screw Fixation Technique Using Locking Compression Plate for Proximal Interphalangeal Arthrodesis in Horses: An Ex Vivo Study.
Veterinary and comparative orthopaedics and traumatology : V.C.O.T    June 4, 2024   doi: 10.1055/s-0044-1787680
de Souza AF, Pereira CAM, Costa C, Fu00fcrst A, Ku00fcmmerle JM, De Zoppa ALV. The aim of this study was to measure the mechanical properties and failure mode of an model of proximal interphalangeal arthrodesis in horses with different methods of proximal screw fixation using a locking compression plate. Methods:  Pastern joint arthrodesis with a 3-hole 4.5-mm narrow locking compression plate was performed on 20 forelimbs of equine cadavers, randomized into four groups based on the fixation method and type of proximal screw used: unicortical cortex, bicortical cortex, unicortical locking, bicortical locking. Single-cycle axial compression testing was conducted unti...
Racing Performance and Sale Result in 145 Thoroughbreds after Arthroscopic Removal of Osteochondral Fragments from the Lateral Femoral Trochlear Ridge as a Yearling (2012-2015).
Veterinary and comparative orthopaedics and traumatology : V.C.O.T    November 1, 2023   doi: 10.1055/s-0043-1776323
Kerbert MP, Freeland RB, Verhaar N, Baker WT. The lateral trochlear ridge (LTR) of the femur is the most common predilection site for osteochondritis dissecans (OCD) in the equine stifle. The objective was to investigate the relationship between lesion size, racing performance, and sale result of Thoroughbreds with LTR OCD following arthroscopic removal as a yearling. Methods:  In this retrospective study, medical records of 145 Thoroughbreds from one equine hospital that underwent surgery for LTR OCD were reviewed; the length and depth of the lesions were measured on preoperative radiographs. Horses were allocated to group S if they...
Minimally Invasive Arthrodesis of the Equine Proximal Interphalangeal Joint: A Biomechanical Comparison of Three 5.5-mm Cortical Screws Inserted in Lag Fashion and Two 7.0-mm Headless Cannulated Dual-Pitch Compression Screws.
Veterinary and comparative orthopaedics and traumatology : V.C.O.T    February 9, 2023   Volume 36, Issue 4 184-192 doi: 10.1055/s-0043-1761244
Rumpel AS, De Carvalho AL, Vassoler JM, Schmidt ML, Mertz CC, Rozo CAC, Campos JK, Alievi MM. The aim of this study was to compare the biomechanical properties of two minimally invasive arthrodesis techniques of the equine proximal interphalangeal (PIP) joint (three transarticular 5.5-mm cortical screws [AO-3TLS] vs. two transarticular 7.0-mm headless cannulated multi-use compression screws [MUC-2TS]) in dynamic non-destructive testing and compression testing to failure. Methods:  The experimental study included six pairs of cadaveric adult equine forelimbs; one limb from each horse was randomly assigned to one of the treatments, and the contralateral limb was submitted to the rem...
Standing Surgical Management of Splint Bone Fractures in 13 Horses: A Comparison to Management Under General Anaesthesia.
Veterinary and comparative orthopaedics and traumatology : V.C.O.T    February 9, 2023   Volume 36, Issue 3 148-156 doi: 10.1055/s-0043-1761241
Auffret V, Bonilla AG. The aim of this article was to describe the technique and outcomes of standing surgical management of splint bone fractures and to compare outcome variables and hospitalization cost to a group with similar fractures treated under general anaesthesia. Methods:  It is a single-institution retrospective study. Surgical technique, surgical time, hospitalization cost and complications were retrieved from the medical records of horses treated surgically for splint bone fractures (2008-2020). Owner telephone follow-up provided data about athletic outcome, client satisfaction and cosmetic appeara...
Comparison of Two Bandage Splint Constructs in an Ex Vivo Equine Metacarpal Fracture Model.
Veterinary and comparative orthopaedics and traumatology : V.C.O.T    December 28, 2022   Volume 36, Issue 2 82-86 doi: 10.1055/s-0042-1759867
Granello ME, Weatherall KM, Lutter JD, Beard WL. The aim of this study was to compare the deflection distance, deflection angle and pre-loading sub-bandage pressure of a transverse, mid-metacarpal fracture in an equine cadaver limb when loaded in bending while stabilized with either a Robert Jones Bandage (RJB) or a single-stack bandage (SS), each containing two orthogonal splints. Methods:  In an ex vivo experimental study, forelimb pairs from eight horses were collected, and one forelimb from each pair was assigned to either the SS or RJB groups. A transverse osteotomy was performed at the midpoint of the metacarpus. After bandaging, ...
Use of Locking Compression Plate and Locking Compression T-Plate for Surgical Arthrodesis of the Carpometacarpal and Distal Tarsal Joints in 13 Horses.
Veterinary and comparative orthopaedics and traumatology : V.C.O.T    September 19, 2022   Volume 36, Issue 1 39-45 doi: 10.1055/s-0042-1756518
Lambert JL, Garcu00eda-Lu00f3pez JM, Gasiorowski JC. The aim of this study was to describe the use of the locking compression plate (LCP) and locking compression T-plate (LCTP) in cases of carpometacarpal and distal tarsal arthrodesis for the treatment of osteoarthritis and small carpal or tarsal bone fractures, and to document clinical outcomes. Methods:  Case records of horses treated with carpometacarpal or distal tarsal arthrodesis via internal fixation using an LCP or LCTP between 2013 and 2021 were reviewed. All cases were evaluated retrospectively. Follow-up information was gained via phone conversation with owners and referring vete...
Simulated Kick Injury to the Mandible in Horses: Study of Fracture Configurations and Physical Parameters of the Impact.
Veterinary and comparative orthopaedics and traumatology : V.C.O.T    July 15, 2022   Volume 35, Issue 4 255-262 doi: 10.1055/s-0042-1748878
Gfrerer L, Michel S, Fu00fcrst AE, Piskoty G, Weisse B, Montavon S, Jackson MA. The goal of this study was to generate mandibular fractures in three regions of the diastema using a metal impactor to simulate a kick from a horse and to determine the mean deceleration in the initial phase of the impact event, the maximum contact force, the impact energy necessary to create a fracture and the duration of the impact. Methods:  Thirty heads of horses aged between 5 and 20 years and euthanatized for various reasons were used. The heads were attached to a steel bar at the occiput at an axial angle of 45 degrees so that the body of the mandible was positioned horizontally ...
Who Is Healthy? A Review of How Equine Control Groups Are Defined in Clinical Orthopaedic Research 1999-2021.
Veterinary and comparative orthopaedics and traumatology : V.C.O.T    May 5, 2022   Volume 35, Issue 4 213-219 doi: 10.1055/s-0042-1745756
Wrangberg T, Kendall A. Proper identification of healthy subjects is essential in case-control studies. However, standardized definitions of healthy controls are lacking in equine orthopaedic research. Objective:  The aim of this study was to define the non-invasive methods used for selecting healthy control horses in osteoarthritis (OA), desmitis and tendinitis research. Methods:  Systematic review. Case-control studies with a healthy control group and longitudinal studies where horses had to be healthy at the start were included. Studies where joints were visualized by arthroscopy or post-mortem examination ...
The Effect of Reducing the Bone to Cast Distance in an Equine Transfixation Pin Cast: An Ex Vivo Biomechanical Study.
Veterinary and comparative orthopaedics and traumatology : V.C.O.T    August 20, 2021   Volume 34, Issue 6 394-400 doi: 10.1055/s-0041-1733859
Bernath CM, Valet S, Rossignol F, Weisse B, Fu00fcrst AE, Ku00fcmmerle JM. The aim of this study was to evaluate the effect of reducing the bone to cast distance on the resistance of the pin to cyclic loading in equine transfixation pin casts. Methods:  Eleven pairs of cadaveric equine third metacarpal bones were prepared and one 6.3/8.0 mm transfixation pin was placed in standard fashion 10 mm proximal to the distal physeal scar into each bone. One metacarpus of each pair was tested with a distance of 10 mm (10 mm group) and the contralateral metacarpus with a distance of 20 mm (20 mm group) between the outer cortex of the bone and the fixation of t...
The Concentration of Metronidazole in the Distal Interphalangeal Joint following Intravenous Regional Limb Perfusion via the Cephalic Vein in Standing Horses.
Veterinary and comparative orthopaedics and traumatology : V.C.O.T    May 12, 2021   Volume 34, Issue 4 287-293 doi: 10.1055/s-0041-1726083
Gustafsson K, Tatz AJ, Dahan R, Britzi M, Soback S, Ahmad WA, Prince H, Kelmer G. The aim of this study was to determine the concentration of metronidazole in the distal interphalangeal joint (DIPJ) of the thoracic limb after administering metronidazole to standing horses by intravenous regional limb perfusion (IVRLP). Methods:  Eleven healthy horses had a wide rubber tourniquet applied to the proximal aspect of the antebrachium for 0.5 hours and 500 mg of metronidazole diluted in physiologic saline solution to a total volume of 108 mL was administered by cephalic IVRLP. Synovial fluid samples were collected from the DIPJ before perfusion and at 0.25, 0.5, 2, 12 ...
Three-Dimensional Printing: Building a Solid Foundation for Improving Technical Accuracy in Orthopaedic Surgery.
Veterinary and comparative orthopaedics and traumatology : V.C.O.T    January 13, 2021   Volume 34, Issue 1 v-vi doi: 10.1055/s-0040-1722257
Guiot LP, Allen MJ.No abstract available
Use of Hausdorff Distance and Computer Modelling to Evaluate Virtual Surgical Plans with Three-Dimensional Printed Guides against Freehand Techniques for Navicular Bone Repair in Equine Orthopaedics.
Veterinary and comparative orthopaedics and traumatology : V.C.O.T    January 13, 2021   Volume 34, Issue 1 9-16 doi: 10.1055/s-0040-1721846
Biedrzycki AH, Kistler HC, Perez-Jimenez EE, Morton AJ. The aim of this study was to evaluate the surgical execution of a virtual surgical plan (VSP) with three-dimensional (3D) guides against a freehand approach in the equine navicular bone using an automated computer analysis technique. Methods:  Eight pairs of cadaveric forelimb specimens of adult horses were used in an experimental study design with modelling. Limbs received either a 3.5 mm cortical screw according to a VSP or using an aiming device. Using computed tomography and computer segmentation, a comparison was made between the executed screw and the planned screw using the Ha...
Time to Peak Concentration of Amikacin in the Antebrachiocarpal Joint Following Cephalic Intravenous Regional Limb Perfusion in Standing Horses.
Veterinary and comparative orthopaedics and traumatology : V.C.O.T    August 16, 2020   Volume 33, Issue 5 327-332 doi: 10.1055/s-0040-1714418
Gustafsson K, Tatz AJ, Dahan R, Britzi M, Soback S, Sutton GA, Kelmer G. The aim of this study was to determine the time (T) to the maximum concentration (C) of amikacin sulphate in synovial fluid of the radiocarpal joint (RCJ) following cephalic intravenous regional limb perfusion (IVRLP) using 2 g of amikacin sulphate. Methods:  Cephalic IVRLP was performed with 2 g of amikacin sulphate diluted in 0.9% NaCl to a total volume of 100 mL in six healthy adult mixed breed mares. An Esmarch's rubber tourniquet was applied for 30 minutes and the antibiotic solution was infused through a 23-gauge butterfly catheter. Synovial fluid was collected from the RCJ ...
Plate Removal after Internal Fixation of Limb Fractures: A Retrospective Study of Indications and Complications in 48 Horses.
Veterinary and comparative orthopaedics and traumatology : V.C.O.T    August 16, 2020   Volume 34, Issue 1 59-67 doi: 10.1055/s-0040-1714411
Donati B, Fu00fcrst AE, Del Chicca F, Jackson MA. The aim of this study was to determine the indications for, and complications of, plate removal surgery in horses that underwent internal fixation of limb fractures. Methods:  Medical records of horses presented to our hospital between 1990 and 2015 for the removal of plates after treatment of limb fractures were reviewed. Data collected at the time of initial presentation, including signalment, history, fracture features and treatment and information about the indications, timing and complications of implant removal were reviewed. Results:  The most common bones involved were the ulna ...
The Effect of Increasing Fracture Site Stiffness on Bone-Pin Interface Stress and Foot Contact Pressure within the Equine Distal Limb Transfixation Cast: A Finite Element Analysis.
Veterinary and comparative orthopaedics and traumatology : V.C.O.T    August 14, 2020   Volume 33, Issue 5 348-355 doi: 10.1055/s-0040-1714353
Lescun TB, Adams SB, Nauman EA, Breur GJ. The aim of this study was to determine how increasing stiffness of fracture site tissues distal to the pins in an equine distal limb transfixation cast influences stress at the bone-pin interface, within the bones distal to the transcortical pins, and contact pressure between the foot and the cast. Methods:  A transfixation cast finite element model was used to compare the bone-pin interface stress, pin stress, bone stress distal to the pins and contact pressure between the foot and the cast, using six stiffness values for a composite tissue block representing progressive stages of fractu...
Anatomy and Ultrasound-Guided Injection of the Medial Branch of the Dorsal Ramus of the Cervical Spinal Nerves in the Horse: A Cadaveric Study.
Veterinary and comparative orthopaedics and traumatology : V.C.O.T    August 10, 2020   Volume 33, Issue 6 377-386 doi: 10.1055/s-0040-1714301
Corraretti G, Vandeweerd JM, Hontoir F, Vanderperren K, Palmers K. The aim of this study was to describe the anatomy of the nerves supplying the cervical articular process joint and to identify relevant anatomical landmarks that could aid in the ultrasound-guided location and injection of these nerves for diagnostic and therapeutic purposes. Methods:  Twelve cadaveric equine necks were used. Five necks were dissected to study the anatomy of the medial branch of the dorsal ramus of the cervical spinal nerves 3 to 7. Relevant anatomical findings detected during dissections were combined with ultrasonographic images obtained in one other neck. Six additiona...
Diffusion of Radiodense Contrast Medium Following Perineural Injection of the Deep Branch of the Lateral Plantar Nerve Using Two Different Techniques in Horses: an In Vivo Study.
Veterinary and comparative orthopaedics and traumatology : V.C.O.T    April 13, 2020   Volume 33, Issue 4 235-242 doi: 10.1055/s-0040-1701655
Cantatore F, Marcatili M, Pagliara E, Bertuglia A, Withers J. This article evaluates and compares the diffusion pattern of radiopaque contrast medium following perineural analgesia of the deep branch of the lateral plantar nerve performed using two different techniques: weight-bearing or flexed. Methods:  This was an experimental study. Methods:  Eight horses were enrolled. Perineural injection of the right and left deep branch lateral plantar nerves was performed with a weight-bearing or flexed technique, using radiopaque contrast medium (iohexol). Radiographic evaluation was performed after 5 (T5), 15 (T15) and 30 (T30) minutes. The diffusion o...
Finite Element Analysis of Six Transcortical Pin Parameters and Their Effect on Bone-Pin Interface Stresses in the Equine Third Metacarpal Bone.
Veterinary and comparative orthopaedics and traumatology : V.C.O.T    December 13, 2019   Volume 33, Issue 2 121-129 doi: 10.1055/s-0039-3399576
Lescun TB, Adams SB, Main RP, Nauman EA, Breur GJ. The objectives of this study were to validate a finite element model of the equine distal limb transfixation cast and to determine the effect of six transcortical pin parameters on bone-pin interface (BPI) stresses in the third metacarpal bone. Methods:  A transfixation cast finite element model was developed from a computed tomography scan of the third metacarpal bone and modelled pin elements. The model was validated by comparing strain measured around a 6.3-mm transfixation pin in the third metacarpal bone with the finite element model. The pin parameters of diameter, number, location,...
Ex Vivo Comparison of the Accuracy of a Clamped with a Hand-Held Drill Guide for Drilling Distal Third Metacarpals and Metatarsals in Equids.
Veterinary and comparative orthopaedics and traumatology : V.C.O.T    September 9, 2019   Volume 33, Issue 1 15-21 doi: 10.1055/s-0039-1694972
James OA, Elce Y, Cillu00e1n-Garcia E, Reardon RJM. The aim of this study was to determine whether a clamped drill guide can be used effectively to drill across equine distal third metacarpals and metatarsals and to compare accuracy and speed of a drilling with a hand-held drill guide. Methods:  Eighty equine cadaver limbs were divided between four surgeons with varying experience. The limbs were randomly allocated to clamped or hand-held drill guides and placed in a stand in an upright/standing position on a metal table. Drilling times from cis- to trans cortices were measured. Post-drilling computed tomography images were used to assess ...
Computed Tomographic Evaluation of Adjacent Segment Motion after Ex Vivo Fusion of Equine Third and Fourth Cervical Vertebrae.
Veterinary and comparative orthopaedics and traumatology : V.C.O.T    August 6, 2019   Volume 33, Issue 1 1-8 doi: 10.1055/s-0039-1693665
Schulze N, Ehrle A, Weller R, Fritsch G, Gernhardt J, Ben Romdhane R, Lischer C. Surgical fusion of vertebral segments is a treatment option for horses with cervical stenotic myelopathy or cervical fracture.Degenerative disease affecting adjacent vertebral segments is a reported complication following surgical vertebral fusion in other species, termed adjacent segment disease. The aim of this study was to evaluate the impact of cervical vertebral fusion on the biomechanics of adjacent vertebral segments in the horse. Methods:  Neck specimens of 12 horses were assessed using computed tomographic imaging. Range of motion (ROM) was determined by measuring the maximum sag...
Risks and Outcomes of Equine Flat Bone Fractures.
Veterinary and comparative orthopaedics and traumatology : V.C.O.T    July 18, 2019   Volume 32, Issue 4 v doi: 10.1055/s-0039-1693467
Johnson KA.No abstract available
Outcome of Pelvic Fractures Identified in 75 Horses in a Referral Centre: A Retrospective Study.
Veterinary and comparative orthopaedics and traumatology : V.C.O.T    July 18, 2019   Volume 32, Issue 4 274-281 doi: 10.1055/s-0039-1688774
Moiroud CH, Coudry V, Denoix JM. The aim of this study was to evaluate the reliability of fracture location and horse sporting discipline as prognostic indicators after a pelvic fracture in a referral centre caseload. Methods:  Data were collected for the short- and long-term follow-up of all cases with a diagnosis of pelvic fracture in a 7-year period. Information was obtained for 75 horses through a postal and internet survey. The proportion of horses returning to competition following fractures was compared between groups according to the competition discipline and the characteristics of the fracture. Results:  Fort...
Comparative Stiffness of an Equine Distal Sesamoid Bone Fracture Model Stabilized with 3.5-mm versus 4.5-mm Cortical Bone Screws in Lag Fashion.
Veterinary and comparative orthopaedics and traumatology : V.C.O.T    July 6, 2019   Volume 32, Issue 6 440-446 doi: 10.1055/s-0039-1692979
Mampe JR, Tatarniuk DM, Suarez-Fuentes DG, Kraus KH. The aim of this study was to to determine the comparative stiffness following repair of an axial sagittal fracture model in equine distal sesamoid bones using either a single 3.5-mm or 4.5-mm cortical bone screw placed in lag fashion. Methods:  The present study was an biomechanical study. Results:  The mean (±standard deviation) stiffness value for the 4.5-mm screw-bone construct (522.49 N/mm ± 168.21) was significantly greater than the 3.5-mm screw-bone construct (408.46 N/mm ± 131.13) ( = 0.047). This represents a 28% difference in mean stiffness. Conclusions:  ...
Evaluation of a Novel Bone Substitute Injection Technique for Potential Treatment of Impact Injury to the Equine Palmar Metacarpal Condyle.
Veterinary and comparative orthopaedics and traumatology : V.C.O.T    July 6, 2019   Volume 32, Issue 6 447-453 doi: 10.1055/s-0039-1692984
Rice HC, Brokken MT, Hostnik ET, Bertone AL. The aim of this study was to evaluate the injection of a bone substitute material (BSM) into an impact lesion in the palmar condyle of the third metacarpal bone. Methods:  This was an controlled study performed on six horses. Methods:  Medial metacarpal condyles were exposed via arthrotomy and a compressive lesion created in anaesthetized horses using 80 psi (27.6 MPa) onto the articular surface ( = 12). Paired limbs were randomly selected as a control or for extra-articular injection of BSM towards the subchondral bone near the compressive lesion. Parameters of the surgical tech...
Ex Vivo Assessment of an Ultrasound-Guided Injection Technique of the Lumbosacral Disc in the Horse.
Veterinary and comparative orthopaedics and traumatology : V.C.O.T    June 11, 2019   Volume 32, Issue 5 383-388 doi: 10.1055/s-0039-1691793
Robert M, Manet H, Manneveau G, Geffroy O. The aim of this study was to describe an ultrasound-guided injection technique of the lumbosacral disc in horses through the cranial vertebral notch of the sacrum and to evaluate both accuracy and potential complications of the technique on equine cadavers. Methods:  Twenty-four injections of the lumbosacral area were performed on 12 equine cadavers shortly after euthanasia under ultrasound guidance with the horse in recumbency using two different dyes (one colour for each side). The lumbosacral area was dissected in each horse and the accuracy of the technique, as well as its potential c...
Arthrographic Study of the Communication between the Tarsal Joints in Crioulo Horses.
Veterinary and comparative orthopaedics and traumatology : V.C.O.T    May 28, 2019   Volume 32, Issue 4 269-273 doi: 10.1055/s-0039-1688770
 The aim of the present study is to assess an arthrographic technique based on the access to the equine tarsus via distal intertarsal and on the existence and frequency of communication between distal and tarsocrural joints in the tarsus of Crioulo horses. Methods:  Fifty Crioulo horses of both sexes from 3 to 8 years old were included in the experiment. Animals with radiographic signs of tarsal osteoarthritis and joint space loss were excluded from the experiment. Contrast was injected in the distal intertarsal joint and radiographs were taken at two different times - Time 0 (after contra...
Standing Needle Arthroscopy of the Metacarpophalangeal and Metatarsophalangeal Joint for Removal of Dorsal Osteochondral Fragmentation in 21 Horses.
Veterinary and comparative orthopaedics and traumatology : V.C.O.T    May 24, 2019   Volume 32, Issue 5 420-426 doi: 10.1055/s-0039-1688984
Bonilla AG. The aim of this study was to report the technique, experience and outcome of standing arthroscopic removal of dorsal osteochondral fragmentation of the metacarpophalangeal and metatarsophalangeal joint using a 1.2-mm needle arthroscope. Methods:  This was a prospective clinical study. Methods:  All horses referred for standing arthroscopic removal of dorsoproximal first phalanx fragments or fragments embedded in the distal aspect of the synovial plica were included. Relevant information from the cases was recorded. Follow-up was obtained by a telephone questionnaire. Results:  Twenty-...
Epoxy-Pin External Skeletal Fixation for Management of Open Bone Fractures in Calves and Foals: A Review of 32 Cases.
Veterinary and comparative orthopaedics and traumatology : V.C.O.T    March 28, 2019   Volume 32, Issue 3 257-268 doi: 10.1055/s-0039-1678736
Aithal HP, Kinjavdekar P, Pawde AM, Dubey P, Kumar R, Tyagi SK, Madhu DN. The aim of this study was to evaluate epoxy-pin external skeletal fixation technique for the treatment of open fractures in calves and foals. Methods:  Twenty-eight calves and four foals (weighing 45-105 kg) with fractures distal to the stifle or elbow made the subject for the retrospective study. The pins (2.0-3.0-mm Kirschner wires, crossed at 60-90°) were fixed at least at two locations in both proximal and distal bone fragments as per the case situation. The pins in the same plane were bent (∼2 cm from the skin) towards the fracture site or joint and were joined using an adhesive t...
Distribution of Pelvic Fractures in Racing and Non-racing Sport Horses: A Retrospective Study of 86 Cases Examined in a Referral Centre.
Veterinary and comparative orthopaedics and traumatology : V.C.O.T    March 28, 2019   Volume 32, Issue 3 215-221 doi: 10.1055/s-0039-1683403
Moiroud CH, Coudry V, Denoix JM. The aim of this study was to analyse the pelvic fracture distribution and location in a referral centre caseload. Methods:  Medical records of 6,717 horses examined in a referral centre over a 7-year period were reviewed to identify all horses diagnosed with a pelvic fracture. Eighty-six horses were identified and divided into three disciplines, namely Thoroughbred racehorses (TBR), Standardbred trotter racehorses (STR) and non-racing sport horses (NRSH). Results:  A pelvic fracture was diagnosed in 1.3% of the cases examined during the study period. Prevalence was significantly higher ...
The Risk of a Shod and Unshod Horse Kick to Create Orbital Fractures in Equine Cadaveric Skulls.
Veterinary and comparative orthopaedics and traumatology : V.C.O.T    March 18, 2019   Volume 32, Issue 4 282-288 doi: 10.1055/s-0039-1683368
Joss R, Baschnagel F, Ohlerth S, Piskoty G, Fu00fcrst A, Bischofberger AS. The aim of this study was to compare the potential of an unshod and shod hoof to cause an orbital fracture in the event of a kick. Methods:  Thirty-four equine cadaveric orbitae were exposed to a steel or horn impactor in a dropping test set-up. An impactor velocity of 7 m/s was used for both materials. Testing was repeated on the same orbit at a velocity of 10 m/s with the horn impactor if no damage occurred. A high-speed camera was used to analyse the impact process. Physical parameters (peak force and impact duration) were calculated based on quantitative video-tracking. Computed tomog...
1 2 3 4