Analyze Diet

Topic:Analytical Methods

Analytical methods in equine research encompass a variety of scientific techniques and tools used to study and evaluate different aspects of horse health, performance, and physiology. These methods help advance our understanding of equine biology, diagnosing conditions, and improving management practices. Common analytical methods include molecular techniques like PCR and ELISA for detecting pathogens and measuring biomarkers, imaging technologies such as ultrasound and MRI for assessing musculoskeletal health, and statistical models for analyzing genetic data and performance metrics. This page compiles peer-reviewed research studies and scholarly articles that explore the development, application, and impact of various analytical methods in equine science.
Evaluation of the veterinary application of a point-of-care device measuring white blood cell counts.
Veterinary journal (London, England : 1997)    April 12, 2012   Volume 194, Issue 1 124-127 doi: 10.1016/j.tvjl.2012.03.005
Riond B, Hofmann-Lehmann R, Lutz H.A point-of-care device (POCD) for measuring total white blood cell count was evaluated for feline, canine, equine and bovine blood samples collected into EDTA. Mean biases were -9.2% (range, -12% to -6.3%) for feline samples, 20.2% (range, 15.3-25.1%) for canine samples, -7.1% (range, -8.3% to -5.9%) for equine samples, and 0.7% (range, -1.1% to 2.5%) for bovine samples. The results were influenced by the presence of nucleated red blood cells. The POCD provided precise, reliable data for feline, equine and bovine samples but the values obtained for the canine counts were overestimations.
Membrane phase behavior during cooling of stallion sperm and its correlation with freezability.
Molecular membrane biology    April 5, 2012   Volume 29, Issue 3-4 95-106 doi: 10.3109/09687688.2012.674161
Oldenhof H, Friedel K, Akhoondi M, Gojowsky M, Wolkers WF, Sieme H.Stallion sperm exhibits great male-to-male variability in survival after cryopreservation. In this study, we have investigated if differences in sperm freezability can be attributed to membrane phase and permeability properties. Fourier transform infrared spectroscopy (FTIR) was used to determine supra and subzero membrane phase transitions and characteristic subzero membrane hydraulic permeability parameters. Sperm was obtained from stallions that show differences in sperm viability after cryopreservation. Stallion sperm undergoes a broad and gradual phase transition at suprazero temperatures...
A new analytical method based on anti-EPO monolith column and LC-FAIMS-MS/MS for the detection of rHuEPOs in horse plasma and urine samples.
The Analyst    March 27, 2012   Volume 137, Issue 10 2445-2453 doi: 10.1039/c2an15662h
Bailly-Chouriberry L, Cormant F, Garcia P, Lönnberg M, Szwandt S, Bondesson U, Popot MA, Bonnaire Y.Recombinant human erythropoietin (rHuEPO) is a 30-34 kDa glycoprotein banned by the racing authorities. For some years this molecule has been detected in race horses in USA and in Europe, and even in racing camels. Although direct methods to differentiate horse endogenous EPO and rHuEPO have been developed either by LC-MS/MS or by isoelectric focusing (IEF) with double-blotting, the short confirmation time of such prohibited hormone in plasma remains a problem for horseracing doping control laboratories. In order to improve the rHuEPOs confirmation process in horse plasma or urine in terms of ...
The effects of yohimbine on the pharmacokinetic parameters of detomidine in the horse.
Veterinary anaesthesia and analgesia    March 8, 2012   Volume 39, Issue 3 221-229 doi: 10.1111/j.1467-2995.2011.00690.x
Knych HK, Steffey EP, Stanley SD.To describe the pharmacokinetics of detomidine and yohimbine when administered in combination. Methods: Randomized crossover design. Methods: Nine healthy adult horses aged 9 ± 4 years and weighing of 561 ± 56 kg. Methods: Three dose regimens were employed in the current study. 1) 0.03 mg kg(-1) detomidine IV (D), 2) 0.2 mg kg(-1) yohimbine IV (Y) and 3) 0.03 mg kg(-1) detomidine IV followed 15 minutes later by 0.2 mg kg(-1) yohimbine IV (DY). Each horse received all three dose regimens with a minimum of 1 week in between subsequent regimens. Blood samples were obtained and plasma analyzed f...
Investigation of the presence of endogenous prednisolone in equine urine by high-performance liquid chromatography mass spectrometry and high-resolution mass spectrometry.
Rapid communications in mass spectrometry : RCM    March 8, 2012   Volume 26, Issue 8 879-886 doi: 10.1002/rcm.6169
Fidani M, Pompa G, Mungiguerra F, Casati A, Fracchiolla ML, Arioli F.After the detection of low concentrations of prednisolone in racehorse urine samples collected at Italian racetracks, a study was initiated to investigate the accuracy of the analytical protocol used and the possible endogenous origin of detected prednisolone. Methods: Multiple reaction monitoring (MRM) MS(2) acquisition with a triple quadrupole (n = 780) and full scan MS(2) and MS(3) (n = 180) acquisition with a linear ion trap were checked. As a further confirmation, ten urine samples were analysed by high-resolution mass spectrometry (HRMS). Results: The study showed the difficulty of ident...
Comparison of an inertial sensor system with a stationary force plate for evaluation of horses with bilateral forelimb lameness.
American journal of veterinary research    March 1, 2012   Volume 73, Issue 3 368-374 doi: 10.2460/ajvr.73.3.368
Keegan KG, MacAllister CG, Wilson DA, Gedon CA, Kramer J, Yonezawa Y, Maki H, Pai PF.To assess the analytic sensitivity of an inertial sensor system for detection of the more severely affected forelimb in horses with bilateral lameness. Methods: 18 adult horses with forelimb lameness. Methods: Horses were fitted with inertial sensors and evaluated for lameness with a stationary force plate as they were trotted in a straight line. Inertial sensor-derived measurements for vertical head movement asymmetry (HMA) and vector sum (VS) of maximum and minimum head height differences between right and left halves of the stride were used to predict differences in mean peak vertical force...
Evaluation of the automated hematology analyzer Sysmex XT-2000iV ™ compared to the ADVIA ® 2120 for its use in dogs, cats, and horses. Part II: Accuracy of leukocyte differential and reticulocyte count, impact of anticoagulant and sample aging. Bauer N, Nakagawa J, Dunker C, Failing K, Moritz A.The automated laser-based hematology analyzer Sysmex XT-2000iV™ provides a 5-part differential count and specific cytograms that are of great interest for large veterinary laboratories. The aim of the study was to validate the Sysmex XT-2000iV compared to the laser-based hematology analyzer ADVIA® 2120 and manual differential in dogs, cats, and horses as well as the impact of anticoagulant (heparin, ethylenediamine tetra-acetic acid [EDTA], and citrate) and storage at 22°C and 4°C. Consecutive fresh K(3)-EDTA blood samples from 216 cats, 314 dogs, and 174 horses were included. The impact ...
Evaluation of the automated hematology analyzer Sysmex XT-2000iV™ compared to the ADVIA® 2120 for its use in dogs, cats, and horses: Part I–precision, linearity, and accuracy of complete blood cell count. Bauer N, Nakagawa J, Dunker C, Failing K, Moritz A.The automated laser-based hematology analyzer Sysmex XT-2000iV™ providing a complete blood cell count (CBC) and 5-part differential has been introduced in large veterinary laboratories. The aim of the current study was to determine precision, linearity, and accuracy of the Sysmex analyzer. Reference method for the accuracy study was the laser-based hematology analyzer ADVIA® 2120. For evaluation of accuracy, consecutive fresh blood samples from healthy and diseased cats (n = 216), dogs (n = 314), and horses (n = 174) were included. A low intra-assay coefficient of variation (CV) of approxim...
The role of diffusion in ferritin-induced relaxation enhancement of protons.
Journal of magnetic resonance (San Diego, Calif. : 1997)    February 22, 2012   Volume 217 36-40 doi: 10.1016/j.jmr.2012.02.005
Boss MA, Chris Hammel P.The influence of proton diffusion on nuclear magnetic resonance (NMR) relaxation was investigated in the presence of horse spleen ferritin at 7 T. Binary mixtures of water and glycerol were used to control diffusion within the range of 0.6-2.0 × 10(-9)m(2)/s, which was confirmed by pulsed gradient techniques. The effect of chemical exchange by hydrolysis between water and glycerol on relaxation was characterized with Carr-Purcell-Meiboom-Gill (CPMG) dispersion experiments. The relaxation rate enhancement of the protons due to ferritin was found to be inversely proportional to the diffusion co...
Detection of myo-inositol trispyrophosphate in equine urine and plasma by hydrophillic interaction chromatography-tandem mass spectrometry.
Drug testing and analysis    February 22, 2012   Volume 4, Issue 5 355-361 doi: 10.1002/dta.397
Wong AS, Ho EN, Wan TS.Myo-inositol trispyrophosphate (ITPP) is a new drug capable of increasing the amount of oxygen in hypoxic tissues. Studies have shown that administration of ITPP increases the maximal exercise capacity in normal mice as well as mice with severe heart failure. The properties of ITPP make it an ideal candidate as a doping agent to enhance performance in racehorses. While there have been speculations in the horseracing industry that the covert use of ITPP is already widespread, no reported method exists for the detection of ITPP in equine biological samples. ITPP is a difficult-to-detect drug due...
Pharmacokinetics and pharmacodynamics of butorphanol following intravenous administration to the horse.
Journal of veterinary pharmacology and therapeutics    February 20, 2012   Volume 36, Issue 1 21-30 doi: 10.1111/j.1365-2885.2012.01385.x
Knych HK, Casbeer HC, McKemie DS, Arthur RM.Butorphanol is a narcotic analgesic commonly used in horses. Currently, any detectable concentration of butorphanol in biological samples collected from performance horses is considered a violation. The primary goal of the study reported here was to update the pharmacokinetics of butorphanol following intravenous administration, utilizing a highly sensitive liquid chromatography-mass spectrometry (LC-MS) assay that is currently employed in many drug-testing laboratories. An additional objective was to characterize behavioral and cardiac effects following administration of butorphanol. Ten exer...
Regulatory control of glycopyrrolate in performance horses using validated UHPLC/MS-MS methods.
Journal of chromatography. B, Analytical technologies in the biomedical and life sciences    February 13, 2012   Volume 889-890 130-137 doi: 10.1016/j.jchromb.2012.02.008
Rumpler MJ, Sams RA, Colahan P.We describe a validated, rapid, sensitive, and specific UHPLC-MS/MS method to detect and quantify glycopyrrolate in 0.5 mL of horse urine. Further, we investigated the elimination of glycopyrrolate in urine after both intravenous and oral administration of clinically relevant doses to Thoroughbred horses. Quantification was performed by weighted, linear regression analysis using a deuterated analogue of glycopyrrolate as internal standard (IS). The method was characterized by a linear range of 5-2500 pg/mL, a lower limit of quantification of 5 pg/mL and a limit of detection of 1 pg/mL. The int...
Quantitative response of volumetric variables measured by a new ultrasound dilution method in a juvenile model of hemorrhagic shock and resuscitation.
Resuscitation    January 25, 2012   Volume 83, Issue 8 1031-1037 doi: 10.1016/j.resuscitation.2012.01.014
Vigani A, Shih A, Queiroz P, Pariaut R, Gabrielli A, Thuramalla N, Bandt C.New volumetric variables of preload, such as total end-diastolic volume index (TEDVI) and active circulation volume index (ACVI) and central blood volume index (CBVI), may represent good indicators of preload and predictors of fluid responsiveness. During acute changes of intravascular volume these variables would allow a more accurate intervention. Objective: The aim of the present study was to investigate the changes in TEDVI, ACVI, CBVI in a juvenile model of hemorrhagic shock and resuscitation. Methods: Twelve anaesthetized ponies (3-8 months of age) were studied at normovolaemia (BASE), a...
Pharmacokinetic profile and pharmacodynamic effects of romifidine hydrochloride in the horse.
Journal of veterinary pharmacology and therapeutics    January 11, 2012   Volume 35, Issue 5 478-488 doi: 10.1111/j.1365-2885.2011.01347.x
Wojtasiak-Wypart M, Soma LR, Rudy JA, Uboh CE, Boston RC, Driessen B.Romifidine HCl (romifidine) is an α(2)-agonist commonly used in horses. This study was undertaken to investigate the pharmacokinetics (PK) of romifidine following intravenous (i.v.) administration and describe the relationship between PK parameters and simultaneously recorded pharmacodynamic (PD) parameters. Romifidine (80 μg/kg) was administered by i.v. infusion over 2 min to six adult Thoroughbred horses, and plasma samples were collected and analyzed using liquid chromatography-mass spectrometry. Limit of quantification was <0.1 ng/mL. PD parameters and arterial blood gases were measur...
Rapid screening of anabolic steroids in horse urine with ultra-high-performance liquid chromatography/tandem mass spectrometry after chemical derivatisation.
Journal of chromatography. A    January 10, 2012   Volume 1232 257-265 doi: 10.1016/j.chroma.2011.12.095
Wong CH, Leung DK, Tang FP, Wong JK, Yu NH, Wan TS.Liquid chromatography/mass spectrometry (LC/MS) has been successfully applied to the detection of anabolic steroids in biological samples. However, the sensitive detection of saturated hydroxysteroids, such as androstanediols, by electrospray ionisation (ESI) is difficult because of their poor ability to ionise. In view of this, chemical derivatisation has been used to enhance the detection sensitivity of hydroxysteroids by LC/MS. This paper describes the development of a sensitive ultra-high-performance liquid chromatography/tandem mass spectrometry (UHPLC/MS/MS) method for the screening of a...
Pharmacokinetic assessment of ketanserin in the horse.
Journal of veterinary pharmacology and therapeutics    November 18, 2011   Volume 35, Issue 5 472-477 doi: 10.1111/j.1365-2885.2011.01346.x
Aljuffali IA, Brainard BM, Moore JN, Kwon S, Allen D, Robertson TP, Arnold RD.The purpose of this study was to determine the pharmacokinetics (PK) of the 5-HT(2A) receptor antagonist ketanserin in healthy adult horses, and to develop a computational model that could be used to optimize dosing. Plasma concentrations of ketanserin were determined using liquid chromatography with mass spectrometry after single and multiple intravenous administration in the horse. A two-compartment linear pharmacokinetic model described the plasma concentration-time profile of ketanserin after single and multiple doses in healthy horses; the terminal half-life was 11.5 h; steady-state volum...
Validation of a liquid chromatography-tandem mass spectrometry method for quantification of glycopyrrolate in horse plasma.
Journal of analytical toxicology    November 15, 2011   Volume 35, Issue 9 656-664 doi: 10.1093/anatox/35.9.656
Rumpler MJ, Sams RA, Colahan P.A rapid, sensitive, and specific ultra-high-performance liquid chromatography with heated electrospray ionization-tandem mass spectrometry (UHPLC-HESI-MS-MS) method to detect and quantify glycopyrrolate in horse plasma has been developed and validated. We also determined glycopyrrolate in plasma after oral and intravenous administration of clinically relevant doses to Thoroughbred horses. Calibration was accomplished by weighted, linear regression analysis using a deuterated analogue of glycopyrrolate as internal standard (IS). Glycopyrrolate (GLY) and the IS (GLY-d(3)) were isolated from plas...
Detection of singly- and doubly-charged quaternary ammonium drugs in equine urine by liquid chromatography/tandem mass spectrometry.
Analytica chimica acta    November 2, 2011   Volume 710 94-101 doi: 10.1016/j.aca.2011.10.046
Ho EN, Kwok WH, Wong AS, Wan TS.Quaternary ammonium drugs (QADs) are anticholinergic agents some of which are known to have been abused or misused in equine sports. A recent review of literature shows that the screening methods reported thus far for QADs mainly cover singly-charged QADs. Doubly-charged QADs are extremely polar substances which are difficult to be extracted and poorly retained on reversed-phase columns. It would be ideal if a comprehensive method can be developed which can detect both singly- and doubly-charged QADs. This paper describes an efficient liquid chromatography/tandem mass spectrometry (LC/MS/MS) m...
Ex vivo spontaneous generation of 19-norandrostenedione and nandrolone detected in equine plasma and urine.
The Journal of steroid biochemistry and molecular biology    October 25, 2011   Volume 128, Issue 1-2 1-11 doi: 10.1016/j.jsbmb.2011.10.005
Guan F, Uboh CE, Soma LR, You Y, Li X, McDonnell S.19-Norandrostenedione (NAED) and nandrolone are anabolic-androgenic steroids (AASs). Nandrolone was regarded solely as a synthetic AAS until the 1980s when trace concentrations of apparently endogenous nandrolone were detected in urine samples obtained from intact male horses (stallions). Since then, its endogenous origin has been reported in boars and bulls; endogenous NAED and nandrolone have been identified in plasma and urine samples collected from stallions. More recently, however, it was suggested that NAED and nandrolone detected in urine samples from stallions are primarily artifacts d...
Development and validation of a method for Cd, Pb and As analysis in bovine, equine and poultry liver by inductively coupled plasma mass spectrometry.
Food additives & contaminants. Part A, Chemistry, analysis, control, exposure & risk assessment    October 14, 2011   Volume 29, Issue 4 609-616 doi: 10.1080/19440049.2011.608381
Lara PC, Fabrino HJ, Germano A, Silva JB.A method for the determination of As, Cd and Pb in bovine, equine and poultry liver by ICP-MS was developed and validated. Samples were digested in a microwave oven using a 10% HNO(3) solution. A set of experiments was made according to a central composite design (CCD) for optimisation of the plasma argon flow, nebuliser argon flow and radiofrequency power applied to the plasma. During the validation, Rh and Ru were evaluated as internal standards and, after validation, the best was Rh for Pb and Cd analysis, but for As better results were obtained without an internal standard. The method allo...
Quantitative analysis of a quaternary ammonium drug: ipratropium bromide by LC/ESI-MS(n) in horse plasma and urine.
Biomedical chromatography : BMC    October 12, 2011   Volume 26, Issue 4 534-540 doi: 10.1002/bmc.1701
Garcia P, Paris AC, Leufroy A, Popot MA, Bonnaire Y.A quantitative method, using LC/ESI-MS(n) with a quadrupole linear ion trap mass analyzer, has been developed for the analysis of ipratropium cation in horse plasma and urine. The method applies solid-phase extraction with WCX cartridges for plasma and MM2 cartridges for urine, prior to analysis by LC/ESI-MS(n). The efficiency of extraction combined with the sensitivity and the selectivity of MS(n) allows for the quantification of ipratropium cation at picogram per milliliter levels. The analytical capabilities of the method have been successfully checked by the quantitative analysis of ipratr...
Determination of sucrose in equine serum using liquid chromatography-mass spectrometry (LC/MS).
Journal of chromatography. B, Analytical technologies in the biomedical and life sciences    October 2, 2011   Volume 879, Issue 30 3668-3671 doi: 10.1016/j.jchromb.2011.09.049
D'Arcy-Moskwa E, Weston L, Noble GN, Raidal SL.Mucosal integrity may be objectively assessed by determination of the absorption of exogenous substances such as sucrose. Gas chromatography-mass spectrometry (GC/MS) and liquid chromatography-mass spectrometry (LC/MS) have been reported for the accurate quantification of low concentrations of sucrose in serum. LC/MS offered the advantage of high sensitivity and mass selectivity without the need for extensive sample derivatization required for GC/MS methods. However, the high polarity and non-volatile nature of the sucrose molecule renders LC/MS techniques challenging. Previously published rep...
Horse metabolism and the photocatalytic process as a tool to identify metabolic products formed from dopant substances: the case of sildenafil.
Drug testing and analysis    October 1, 2011   Volume 3, Issue 10 724-734 doi: 10.1002/dta.334
Medana C, Calza P, Giancotti V, Dal Bello F, Pasello E, Montana M, Baiocchi C.Two horses were treated with sildenafil, and its metabolic products were sought in both urine and plasma samples. Prior to this, a simulative laboratory study had been done using a photocatalytic process, to identify all possible main and secondary transformation products, in a clean matrix; these were then sought in the biological samples. The transformation of sildenafil and the formation of intermediate products were evaluated adopting titanium dioxide as photocatalyst. Several products were formed and characterized using the HPLC/HRMS(n) technique. The main intermediates identified in thes...
A combination of single-drop microextraction and open tubular capillary electrochromatography with carbon nanotubes as stationary phase for the determination of low concentration of illicit drugs in horse urine.
Talanta    September 16, 2011   Volume 86 278-283 doi: 10.1016/j.talanta.2011.09.014
Stege PW, Lapierre AV, Martinez LD, Messina GA, Sombra LL.In this study we developed an interesting alternative to HPLC-mass spectrometry for the quantification of seven important drugs of abuse in racehorses. The procedure proposed in this work is a combination of single-drop microextraction (SDME) and an open tubular capillary electrochromatography (OT-CEC) using multi-wall carbon nanotubes (MWCTs) immobilized into a fused-silica capillary as a stationary phase. The SDME showed to be a powerful tool for extraction/preconcentration of the seven drugs analyzed in the study, showing an enrichment factor between 38- and 102-fold depending on the drug. ...
Evaluation of the Mythic 18 hematology analyzer for use with canine, feline, and equine samples. Wassmuth AK, Riond B, Hofmann-Lehmann R, Lutz H.The Mythic 18 is a fully automated hematology bench-top analyzer using impedance technology for a complete blood cell count (CBC) and a 3-part white blood cell count (WBC) differential. The purpose of the current study was to evaluate the Mythic for assessment of agreement, precision, linearity, carry-over, stability, and usability under practice conditions. Ethylenediamine tetra-acetic acid-blood samples from 122 dogs, 140 cats, and 123 horses were analyzed with the Mythic and reference methods (Sysmex XT-2000iV, manual hematocrit, and microscopic WBC differentiation). Pearson's coefficient o...
Development of a multiplex assay for the detection of antibodies to Borrelia burgdorferi in horses and its validation using Bayesian and conventional statistical methods.
Veterinary immunology and immunopathology    August 17, 2011   Volume 144, Issue 3-4 374-381 doi: 10.1016/j.vetimm.2011.08.005
Wagner B, Freer H, Rollins A, Erb HN, Lu Z, Gröhn Y.Lyme disease is a zoonotic, vector-borne disease and occurs in mammals including horses. The disease is induced by infection with spirochetes of the Borrelia burgdorferi sensu lato group. Infection of mammalian hosts requires transmission of spirochetes by infected ticks during tick bites. Lyme disease diagnosis is based on clinical signs, possible exposure to infected ticks, and antibody testing which is traditionally performed by ELISA and Western blotting (WB). This report describes the development and validation of a new fluorescent bead-based multiplex assay for the detection of antibodie...
Efficient use of retention time for the analysis of 302 drugs in equine plasma by liquid chromatography-MS/MS with scheduled multiple reaction monitoring and instant library searching for doping control.
Analytical chemistry    August 12, 2011   Volume 83, Issue 17 6834-6841 doi: 10.1021/ac2016163
Liu Y, Uboh CE, Soma LR, Li X, Guan F, You Y, Chen JW.Multiple drug target analysis (MDTA) used in doping control is more efficient than single drug target analysis (SDTA). The number of drugs with the potential for abuse is so extensive that full coverage is not possible with SDTA. To address this problem, a liquid chromatography tandem mass spectrometric method was developed for simultaneous analysis of 302 drugs using a scheduled multiple reaction monitoring (s-MRM) algorithm. With a known retention time of an analyte, the s-MRM algorithm monitors each MRM transition only around its expected retention time. Analytes were recovered from plasma ...
Method to calibrate phase fluctuation in polarization-sensitive swept-source optical coherence tomography.
Journal of biomedical optics    August 3, 2011   Volume 16, Issue 7 070502 doi: 10.1117/1.3597721
Lu Z, Kasaragod DK, Matcher SJ.We present a phase fluctuation calibration method for polarization-sensitive swept-source optical coherence tomography (PS-SS-OCT) using continuous polarization modulation. The method uses a low-voltage broadband polarization modulator driven by a synchronized sinusoidal burst waveform rather than an asynchronous waveform, together with the removal of the global phases of the measured Jones matrices by the use of matrix normalization. This makes it possible to average the measured Jones matrices to remove the artifact due to the speckle noise of the signal in the sample without introducing aux...
Comparison of pH, lactate, and glucose analysis of equine synovial fluid using a portable clinical analyzer with a bench-top blood gas analyzer.
Veterinary surgery : VS    July 19, 2011   Volume 40, Issue 7 811-816 doi: 10.1111/j.1532-950X.2011.00854.x
Dechant JE, Symm WA, Nieto JE.To compare agreement between a portable clinical analyzer and laboratory-based bench-top analyzer for analysis of pH, lactate, and glucose concentrations in synovial fluid. Methods: Prospective experimental study. Methods: Clinically normal horses (n=8); 6 horses euthanatized for reasons unrelated to the study; 11 horses that had synoviocentesis for reasons other than sepsis; 7 horses that had synoviocentesis for evaluation of sepsis; and 2 horses without recorded clinical data. Median age of horses was 8 years (range, 1 day to 24 years). Methods: Supernatant from each synovial fluid sample wa...
Comparison of different liquid chromatography stationary phases in LC-HRMS metabolomics for the detection of recombinant growth hormone doping control.
Journal of separation science    June 27, 2011   Volume 34, Issue 24 3493-3501 doi: 10.1002/jssc.201100223
Boyard-Kieken F, Dervilly-Pinel G, Garcia P, Paris AC, Popot MA, le Bizec B, Bonnaire Y.Growth hormone (GH) is a polypeptide suspected of being used in horse racing to speed up physical performances. Despite scientific advances in the recent years, the control of its administration remains difficult. In order to improve it, a metabolomics study through LC-high resolution mass spectrometry measurements was recently initiated to assess the metabolic perturbations caused by recombinant equine growth hormone administration. Few tens of ions not identified structurally were highlighted as compounds responsible for the modification of metabolic profiling observed in treated animals. Th...
1 23 24 25 26 27 51