Topic:Hematology
Hematology in horses involves the study of blood, its components, and related disorders in equine species. This field encompasses the analysis of red blood cells, white blood cells, platelets, hemoglobin, and hematocrit levels to assess the health status of horses. Hematological parameters are used to evaluate various physiological and pathological conditions, including anemia, infections, and immune-mediated diseases. Techniques such as complete blood counts (CBC) and blood smear evaluations are commonly employed to gather insights into the equine circulatory system. This page compiles peer-reviewed research studies and scholarly articles that explore the methodologies, findings, and clinical implications of hematological assessments in equine medicine.
Method for the automation of equine differential leucocyte counts. A technique for automating equine differential leucocyte counts by analysis of volume distribution curves using the Coulter Channelyzer has been developed and evaluated. A comparison between the results obtained by this method and standard microscopic techniques showed good agreement in most cases. Blood samples can be analysed for both differential and total leucocyte counts at a rate of 25/h. For each sample an average 16,000 leucocytes are classified by the Channelyzer. The method of volume analysis is suitable for the precise counting of polymorphonuclear neutrophils, lymphocytes and eosin...
Vitamin A nutrition of the equine: growth, serum biochemistry and hematology. Four diets were fed to pony fillies for 40 weeks. One group received a basal diet low in carotene, designated mildly deficient. Other groups were fed basal diet plus vitamin A propionate equivalent to 12 (control), 1,200 (mildly intoxicated) or 12,000 (severely intoxicated) microgram retinol/kg body weight/day. The mildly deficient group exhibited impairment of growth and hematopoiesis with decreased serum concentrations of iron, albumin and cholesterol prior to depletion of liver vitamin A. Growth was depressed in mildly intoxicated and severely intoxicated fillies. The latter became debilita...
Effects of different anticoagulants on determination of erythrocyte glutathione peroxidase. Glutathione peroxidase (GSH-Px) was determined in whole blood from cows, goats and horses using cumenehydroperoxide as substrate. Heparin was found to be the most suitable anticoagulant. The highest activities of GSH-Px were found with high concentrations of heparin in the blood samples (1000 and 1250 IU/ml of blood). Sodium fluoride and especially EDTA and sodium citrate gave lower activities of the enzyme. Storage of the blood samples at room temperature (~20°C) or in a refrigerator (~5°C) for 3 days resulted in significantly lower activities of the enzyme, especially in horse blood. Gluta...
Therapeutic effect of phenylbutazone on experimental acute Escherichia coli endotoxemia in ponies. Phenylbutazone (PBZ), a classic anti-inflammatory and prostaglandin-synthesis inhibitor drug, was used to determine the role of prostaglandins and other mediators on the development and perpetuation of the response to intraperitoneal Escherichia coli endotoxin administration. The PBZ (15 mg/kg of body weight) was administered IV 30 minutes after endotoxin administration and was repeated later at 6 and 12 hours at a dose of 10 mg/kg. A variety of evaluation measurements (hematologic, blood glucose, pyruvate, lactate and fibrinogen, serum beta-glucuronidase, prothrombin time, blood gases, hepati...
Attempted induction of an avian eosinophilia using various agents. A series of experiments is described in which attempts were made to produce an avian eosinophilia using various agents. Although none of the experiments was decisive, two demonstrated a slight rise in the eosinophil counts. In one experiment horse serum was injected into a group of fowls on alternate days for 42 days. No eosinophils were seen in any blood smears after this treatment. After a rest period of eight days the birds received further injections for 10 days. The mean eosinophil count rose to over 4 per cent with a range of 1 to 11 per cent. It is considered that this type of response ...
Electrocardiography and haematology of horses competing in a three-day event. The electrocardiograms of 22 horses competing in a 3-day event were recorded before and after the event. In addition, blood samples were taken for determination of packed cell volume and total plasma protein before, during and after the speed and endurance phases (Day 2). The electrocardiograms of 13 horses showed various abnormalities before the event, most of which were T wave changes. As a result of competition in the event, there was a significant increase in the number of leads showing T wave abnormalities when the electrocardiograms taken before and after the event were compared. At all ...
Alterations in horse blood cell count and biochemical values after halothane anesthesia. Quantitative changes in hematologic and serum biochemical values associated with prolonged general anesthesia produced by known alveolar doses of halothane in oxygen were determined in six young, healthy horses under laboratory conditions. In addition, 25 young equine patients anesthetized for shorter periods under clinical conditions were similarly (except hematologic values) prospectively evaluated. In normal horses, muscle- and hepatic-derived serum biochemical values were mildly increased immediately after anesthesia. Values after anesthesia remained at greater than base-line values for up...
Haematology as an aid to prognosis of chronic laminitis. A COMMON progression of chronic laminitis is ischaemic
necrosis with secondary infection a frequent complication.
For 6 years we have performed a complete blood count
(CBC) on all hospitalised horses (at the University of Missouri
Veterinary Hospital) every Monday, Wednesday and Friday.
Preliminary scrutiny of the results indicated that persistent
elevation of the total white blood cell count (WBC) and
neutrophilia was consistent with poor prognosis in horses
affected with laminitis. Because of these considerations we
decided to perform a retrospective examination of the blood
cell d...
Hematology and biochemistry reference values for the light horse. Reference hematology and biochemistry intervals are presented for a number of variables of clinical interest determined for blood samples obtained from 60 thoroughbred mares, 12 thoroughbred foals and 50 standardbred horses in training. The observations for each variable were examined for outliers and Gaussian distribution. Parametric analysis was used where the observations were Gaussian initially or after any of four transformations, otherwise nonparametric analysis was required for estimation of the 2.5 and 97.5 percentiles. Description of the sample collection procedures, laboratory method...
Minimal changes in blood cell counts and biochemical values associated with prolonged isoflurane anesthesia of horses. The potential toxicity to horses of 7.33 +/- 0.87 SD minimal alveolar concentration hours of isoflurane anesthesia was evaluated by sequential determination of blood cell counts, electrolyte concentrations, and certain blood chemical values. Minimal or no serious toxicosis was observed for up to 7 days after anesthesia was terminated.
Effect of pneumatic tourniquet application to the distal extremities of the horse: blood gas, serum electrolyte, osmolality, and hematologic alterations. With 120 minutes of pneumatic tourniquet application to the distal extremity in the horse, the following effects were noted in the tourniqueted limb vein (TLV): (i) local venous acidemia, (ii) increase in serum K+ concentrations, (iii) minimal changes in plasma total solids, Na+, or osmolality, and (iv) apparent reduction in hematocrit values when compared with the same measurements in the control leg. Tourniquet release after 120 minutes produced a prompt return to base line for PCV and PO2 in the TLV; however, pH, PCO2 and K+ values in the TLV required 10 to 15 minutes to reach base line (TL...
Equine Escherichia coli endotoxemia: comparison of intravenous and intraperitoneal endotoxin administration. Certain physiologic and hematologic data were determined in ponies given Escherichia coli endotoxin by three routes: single IV dose, single intraperitoneal (IP) dose, and multiple IP boluses. In all ponies, the reaction was characterized by weakness, depression, peripheral circulatory abnormalities, and pyrexia. The pyrexia was more severe and was sustained in the ponies given multiple IP bolus endotoxin. Changes in packed cell volume, peripheral blood neutrophil, lymphocyte, and thrombocyte counts, and blood glucose were noticed in the three groups. Blood lactate and beta-glucuronidase values...
Studies on experimental enteric salmonellosis in ponies. Clinical, bacteriological, serological and haematological observations were made on 13 adult ponies orally inoculated with Salmonella typhimurium. The results were compared to two control ponies and four others infected by accidental transmission. The clinical responses in inoculated ponies included pyrexia lasting four days and neutropaenia during the first five days after inoculation followed by a neutrophilia. Pyrexia and neutropaenia was associated with maximal shedding of organisms in the rectal faeces. Changes in the character of the faeces occurred between one and two days after inocula...
Electrocardiography, heart scope and haematology of horses competing in an endurance ride. Thirty-one horses competing in a 100 kilometre endurance ride had electrocardiograms recorded before and after the ride from which the heart score of each horse was calculated. Blood was also taken to determine the packed cell volume (PCV) and total plasma protein (TPP) before the ride, after 60 kilometres (mid ride) and at completion of the ride. Statistical analysis of the heart scores showed that a faster group of horses had significantly higher heart scores than either a slower group or those eliminated due to inadequate recovery of heart rate. No horses developed electrocardiogram abnorma...
The effect of binding ions on the oxidation of horse heart ferrocytochrome c. The research explores how different binding ions affect the oxidation speed of horse heart ferrocytochrome c, a protein, by potassium ferricyanide at a constant ionic strength. Studying the Ion Effect […]
Electrocardiography, Heart Score, and Hematology of Horses Competing in an Endurance Ride. Thirty-one horses competing in a 100 kilometre endurance ride had electrocardiograms recorded before and after the ride from which the heart score of each horse was calculated. Blood was also taken to determine the packed cell volume (PCV) and total plasma protein (TPP) before the ride, after 60 kilometres (mid-ride) and at completion of the ride. Statistical analysis of the heart scores showed that a faster group of horses had significantly higher heart scores than either a slower group or those eliminated due to inadequate recovery of heart rate. No horses developed electrocardiogram abnorma...
Variability in erythrocyte deformability among various mammals. Deformability is an important aspect of erythrocyte physiology and has been extensively studied using human red cells. We have studied erythrocytes from 25 different animals using a viscometric technique. Erythrocyte diameters ranged from 3.3 microns in the goat to 11.4 microns for the elephant seal. Erythrocytes from most species deformed readily when a fluid shear stress was applied. A deformability index of the stressed cell defined as (length - width)/(length + width) correlated with cell size. The erythrocytes of four animals (pygmy goat, goat, Batanga horse, and miniature horse) deformed...