Medical devices in equine care encompass a range of tools and technologies designed to diagnose, monitor, or treat medical conditions in horses. These devices can include imaging equipment, such as ultrasound and radiography machines, which help in visualizing internal structures; wearable sensors for tracking vital signs and activity levels; and therapeutic devices, such as laser therapy equipment, used in rehabilitation. Medical devices are integral to equine veterinary practice, aiding in the assessment of health status, guiding treatment decisions, and monitoring recovery. This page compiles peer-reviewed research studies and scholarly articles that explore the development, application, and impact of medical devices in equine medicine.
Franci P, Bertamini A, Bertamini O, Pilla T, Busetto R.A new volatile anaesthetic agent delivery system was tested in 15 horses undergoing scheduled surgical procedures. The delivery system consisted of a laptop computer (with dedicated software), a computer-controlled syringe driver (loaded with liquid isoflurane) connected to the inspiratory arm of a large-animal circle breathing system and a respiratory gas monitor, providing isoflurane end-tidal concentrations (ET(measured)) every 20 s to the computer. Following induction and connection to the breathing system, mechanical ventilation was started. The bodyweight (BW), fresh gas flow, breathing ...
Norton JL, Nolen-Walston RD, Underwood C, Slack J, Boston R, Dallap BL.Central venous pressure (CVP) customarily has been measured in veterinary patients with water manometry. However, many institutions are now using stallside electronic monitors in both anesthesia and intensive care units for many aspects of patient monitoring. Objective: Electronic stall side monitoring devices will agree with water manometry for measurement of CVP in horses. Methods: Ten healthy adult horses from the university research herd. Methods: Central venous catheters were placed routinely, and measurements were obtained in triplicate with each of the 3 methods every 12 hours for 3 day...
Hendrickson DA.This article describes surgical complications associated with laparoscopy, how to avoid them, how to recognize them if they do happen, and how to deal with them in the most expedient method possible. Complications of sedation, anesthesia, positioning, the general surgical approach, and complications associated with specific surgical procedures are examined. The best defense against surgical complications is a thorough training program and an understanding of anatomy that will help the surgeon work in the three-dimensional environment while being limited to two dimensions on the monitor. The au...
Verwilghen D, Ponthier J, Van Galen G, Salciccia A, Sandersen C, Serteyn D, Grulke S.Radial extracorporeal shockwave therapy (ESWT) is widely used in equine practice for the treatment of orthopedic problems. However, its original use as a lithotripsy device in human and canine urology led us to postulate that it could be used as an alternative to the surgical treatment of urethral calculi in horses. Objective: Radial ESWT can easily and safely fragment calculi in the distal urethra of the horse. Methods: Two postmortem cases and 1 live case of obstructive urinary disease admitted at the Veterinary Teaching Hospital of Liege. Methods: A radial shockwave device was directly appl...
Qin SH, Sun L, Zheng XJ.To explore the Ilizarov mini-invasive distraction technique for the treatment of severer ankle and foot deformities secondary to ischemic contracture of the leg. Methods: Based on the tension-stress low of Ilizarov, a serial of adjustable three dimensions external distractive instrument was developed in our department. From April 2002 to March 2004, 8 patients with ankle and foot deformities secondary to ischemic contracture of the leg induced by trauma and fracture were treated with the distractive instrument. Of them, 4 patient were male and 4 female, aged from 13 to 31 years with an average...
The heart surgery forumApril 1, 2005
Volume 7, Issue 5 E498-E502 doi: 10.1532/HSF98.20041087
Eckstein FS, Tevaearai H, Keller D, Schmidli J, Immer FF, Seiler C, Saner H, Carrel TP.This study details a single-center experience with the 3F Therapeutics stentless aortic bioprosthesis(investigational device) and is part of a prospective,nonrandomized worldwide multicenter study. We assessed the implantation procedure and the valve's efficacy in terms of early mortality and morbidity and early echocardiographic valve performance. Methods: Between June 2001 and March 2004, 24 patients (14 men/10 women) underwent aortic valve replacement(AVR) with a 3F valve. Mean age was 72 +/- 13 years(range, 31-88 years). Combined revascularization was performed in 12 patients; 1 patient re...
Hoffman AM.Respiratory diagnostic instruments previously available only to referral centers should be converted into miniature, portable, wireless medical devices for use in practice. Internet and wireless connections of these instruments should expedite the process of seeking second opinions and in general information sharing. We are moving into a world of greater objectivity that should free us from speculation in some areas, yet open new avenues for research and innovation in others.
Hendrickson DA.Equine surgery continues to benefit from advances in endoscopic surgical techniques. Much of what we have learned in equine endoscopy comes from techniques used in humans. Descriptions of the normal anatomy of the standing horse and advances in instrumentation have improved our ability to perform laparoscopic surgery in standing and dorsally recumbent horses. This article describes the history of laparoscopy and available instrumentation.
Blikslager AT, Tate LP.There are clearly a number of applications for which flexible endoscopic laser surgery has become the state of the art in equine surgery, and the Nd:YAG laser seems to be the most versatile instrument for this type of surgery. Nevertheless, it is critical to understand the advantages and disadvantages of each laser technique. For example, the Nd:YAG laser used in a noncontact fashion seems to be superior when ablation of tissue is required such as treatment of upper airway masses. Conversely, contact Nd:YAG laser techniques have proven themselves to be superior when more precise cutting is adv...
Whan G, Phillips J, Bullock S, Runciman RJ, Pearce S, Hurtig M.A novel, multi-use, low-stiffness and low-cost transducer for measuring in vitro strains has been developed and tested. Currently available strain measurement methods are either too expensive, too complicated or too inflexible for multi-use strain measurement. The stainless-steel modular strain measurement clip introduced here was instrumented with four 350 Omega axial strain gauges in a full Wheatstone bridge configuration to take advantage of commonly available strain gauge amplifier equipment. Adjustable extension arms were designed to allow greater application versatility. The clip was cal...
Steffey EP.Both desflurane and sevoflurane offer theoretical and practical advantages over other inhalation anesthetics for horses. The lower solubility of both agents provides improved control of delivery and helps to counteract the confounding influence of the voluminous patient breathing circuit commonly used for anesthetizing horses. The lower solubility should account for faster rates of recovery compared with the older agents; whether or not the quality of recovery differs remains to be objectively evaluated in a broad range of circumstances. The pharmacodynamic effects are, in large part, similar ...
Dursun E, Dursun N, Alican D.In this study our aim was to evaluate the effectiveness of Ankle-Foot Orthoses (AFOs) on gait function in patients with spastic cerebral palsy for whom orthoses were indicated to control dynamic equines deformity. Methods: Twenty-four spastic cerebral palsied patients with dynamic equines deformity were included in the study. Videotape recordings were performed to each patient on the same day with barefoot and AFOs. Temporal distance factors including velocity, cadence, stride length, stride width and Clinical Gait Assessment Score (CGAS) were compared across two conditions. Results: The use o...
van Loon G, Laevens H, Deprez P.The purpose of this study was to perform temporary atrial pacing and to determine the atrial strength-duration (S-D) curve which displays the minimal pulse intensity necessary to achieve atrial capture. In 7 horses, atrial pacing was applied using a temporary pacing catheter and a pacemaker as electrical pulse generator. Using the stimulus reduction method, 3 approaches for atrial threshold determination were used. With the fixed pulse width method, at several pulse widths, the corresponding minimal amplitudes to achieve capture were determined, describing an S-D curve. With the fixed amplitud...
Auer JA, Watkins JP.In recent years fracture fixation in the horse has changed significantly. New devices, mainly adapted from the human field, have been successfully introduced into large animal surgery. Examples of such implants include the DCS/DHS implant system, the self-tapping screw, the cannulated screw, and the pinless external fixator. However, new devices have also been developed exclusively for equine fracture management, including the interlocking intramedullary nail and the external skeletal fixation device. With these devices the surgeon has more options for repairing fractures in horses. Neverthele...
Trotter GW, McIlwraith CW.Surgical procedures completed under arthroscopic guidance have become commonplace in many equine practices and have largely replaced surgery using arthrotomy incisions. With a limited amount of equipment, numerous diagnostic and surgical procedures can be completed. Surgeons need to become familiar with regional and intraarticular (intrasynovial) anatomy to ensure that proper surgical approaches are used, access to the lesion will be realized, and potential complications will be minimized. Specialized motorized instruments and surgical lasers are now available and may be useful in the treatmen...
Roethlisberger-Holm K, Roepstorff L, Obel N.After giving an account of the principles of pressure measurement in flowing air and a review of the literature on tracheal catheters, the authors describe the construction, the introduction and the function of their own transtracheal catheter. This is a teflon catheter with several side-ports which is introduced into the cervical trachea by a guide technique. After introduction, the catheter is stiffened by the insertion of 2 steel wires. The catheter was studied in model experiments concerning: a) the ability to measure the static pressure in flowing air, and b) the dynamic accuracy of a rec...
Balazs EA, Denlinger JL.Viscosupplementation is a new medical concept that has as its therapeutic goal the restoration of rheological homeostasis in pathological structures such as osteoarthritic joints. When the normal viscoelasticity of a solid tissue compartment or the elastoviscosity of a liquid tissue compartment is decreased under pathological conditions, normal function and regenerative processes are impaired. By introducing viscosupplementary devices, the normal rheological state of such compartments is restored or augmented. These devices stay in the tissue compartment for various periods of time, depending ...
Gregg AS, Jones RS, Snowdon SL.A fault in the assembly of a Matrix Large Animal Circle anaesthetic machine resulted in reversal of fresh gas flow through the vaporizer. The fault was discovered only after the sudden development of excessive depth of anaesthesia in two equine patients. Laboratory investigations were conducted to determine the effect of flow reversal on vaporizer output. Results indicated that output concentration was approximately doubled under these conditions.
Dziezyc J, Millichamp NJ, Smith WB.Two Mackay-Marg tonometers and 2 Tono-Pen tonometers were evaluated in eyes in which intraocular pressure (IOP) had been altered and measured by use of a manometer. Eyes of anesthetized dogs and enucleated horse eyes were used. Compared with the manometer, none of the tonometers accurately measured IOP over the range between 0 and 100 mm of Hg. However at manometer measurements from 0 to 30 mm of Hg, several of the tonometers accurately measured IOP. In addition, significant differences were observed when the measurement accuracy of one tonometer was compared with that of another, especially a...
Hoskinson JJ, Wooten P, Evans R.Nonsurgical, percutaneous, transvenous removal of a catheter fragment embolus was performed in a 14-day-old Thoroughbred foal. A basket retrieval catheter was introduced into the jugular vein and manipulated under fluoroscopic guidance to remove the fragment from the right side of the heart. Percutaneous retrieval should be considered as an alternative to thoracotomy for retrieval of intracardiac or intravascular foreign bodies.
Whitehair KJ, Watney GC, Leith DE, Debowes RM.The clinical usefulness of two pulse oximeters was evaluated at two probe sites in nine anesthetized horses. The hemoglobin saturation determined by the pulse oximeters (SaOx) was compared with the hemoglobin saturation calculated from the measured arterial oxygen tension (SaO2). The mean and standard deviation (SD) were calculated from the differences in saturation measurements, over the saturation range of 80% to 100%, for each oximeter used at the tongue probe site and for one oximeter used at the ear. The oximeter results tended to underestimate the SaO2 with mean differences of -3.7% on t...
Geddes LA.The benchmarks in cardiac pacing are identified, beginning with F. Steiner (1871), who rhythmically stimulated the chloroform-arrested hearts of 3 horses, 1 donkey, 10 dogs, 14 cats, and 8 rabbits. The chloroform-arrested heart in human subjects was paced by T. Greene in the following year (1872) in the UK. In 1882, H. Ziemssen in Germany applied cardiac pacing to a 42-year old woman who had a large defect in the anterior left chest wall subsequent to resection of an enchondroma. Intentional cardiac pacing did not occur until 1932, when A.A. Hyman in the US demonstrated that cardiac pacing cou...
Beroza GA.A device and technique for intra-operative gastro-intestinal lavage was developed to remove ingesta from the stomach, large intestine and caecum of horses. The Gastro-Intestinal Lavage System (GILS) is composed of a nozzle connected to both water under pressure and suction. Water jets across an intake portal in the nozzle, breaks up food and debris within the nozzle and is evacuated under negative pressure into the aspirating tube which is connected to a collection drum. The GILS nozzle was introduced at the pelvic flexure through a sterile enterotomy cuff and plastic sleeve. Water was first a...
Sanders-Shamis M, Bramlage LR, Weisbrode SE, Gabel AA.The effect of electrical stimulation by means of selected electromagnetic field devices on healing of cannon bone osteotomies in horses was examined. The defects were created as 3 cm x 1 mm longitudinal osteotomies through the dorsal cortices of the mid-metacarpi/metatarsi of adult horses. This type of defect would asses bone healing in a situation similar to an acute, stable fracture of the cortex. Three electromagnetic devices of different design were tested in three different groups of horses. Healing was evaluated radiographically and histologically. Results showed that osteotomies treated...
Fritsch R, Hausmann R.In 26 horses measurings of blood pressure, using the Dinamap 1255 research monitor, were performed and compared for accuracy with blood pressure values obtained by direct measurement in the arteria carotis. It was found that oscillometrically ascertained initial blood values in standing horses have a sufficient correlation to initial blood pressure values obtained by direct measurement. But every blood pressure change is registered too late, when using the oscillometric blood pressure apparatus. This temporal delay becomes unacceptable, when a considerable increase in blood pressure occurs. A ...
The heart surgery forumApril 1, 2005
Volume 7, Issue 5 E498-E502 doi: 10.1532/HSF98.20041087
Eckstein FS, Tevaearai H, Keller D, Schmidli J, Immer FF, Seiler C, Saner H, Carrel TP.This study details a single-center experience with the 3F Therapeutics stentless aortic bioprosthesis(investigational device) and is part of a prospective,nonrandomized worldwide multicenter study. We assessed the implantation procedure and the valve's efficacy in terms of early mortality and morbidity and early echocardiographic valve performance. Methods: Between June 2001 and March 2004, 24 patients (14 men/10 women) underwent aortic valve replacement(AVR) with a 3F valve. Mean age was 72 +/- 13 years(range, 31-88 years). Combined revascularization was performed in 12 patients; 1 patient re...
Hoffman AM.Respiratory diagnostic instruments previously available only to referral centers should be converted into miniature, portable, wireless medical devices for use in practice. Internet and wireless connections of these instruments should expedite the process of seeking second opinions and in general information sharing. We are moving into a world of greater objectivity that should free us from speculation in some areas, yet open new avenues for research and innovation in others.
Biedrzycki A, Markel MD, Brounts SH.To compare the in vitro biomechanical properties of a novel subcuticular stapling device to current methods of abdominal skin closure for equine abdominal surgery. Methods: In vitro randomized, matched design. Methods: Equine ventral median abdominal skin specimens (n = 24 horses). Methods: Subcuticular absorbable staples (SAS), metallic staples (MS), polyglyconate suture (PG), and nylon monofilament (NYL) were applied to longitudinally transected portions of equine ventral midline skin. Loads that resulted in an initial failure point and the ultimate failure load and mechanism were record...
Reiners JK, Rossdeutscher W, Hopster K, Kästner SBR.The use of pulse oximetry in horses is limited due to inadequate readings with conventional transmission sensor probes. Objective: The objectives of this study were to 1) develop an improved sensor design for horses to be used at an appropriate anatomical site, and 2) evaluate this design in an experimental study. Methods: In vivo experiment. Methods: A new sensor design for reflectance pulse oximetry at the buccal mucosa was developed. A conventional Nonin 2000SL sensor for transmission pulse oximetry was included into this design. Three different prototypes (N1, N2a, N2b) were constructed an...
van Loon G, Laevens H, Deprez P.The purpose of this study was to perform temporary atrial pacing and to determine the atrial strength-duration (S-D) curve which displays the minimal pulse intensity necessary to achieve atrial capture. In 7 horses, atrial pacing was applied using a temporary pacing catheter and a pacemaker as electrical pulse generator. Using the stimulus reduction method, 3 approaches for atrial threshold determination were used. With the fixed pulse width method, at several pulse widths, the corresponding minimal amplitudes to achieve capture were determined, describing an S-D curve. With the fixed amplitud...
Adolfsson KH, Sjöberg I, Höglund OV, Wattle O, Hakkarainen M.A resorbable 3D printed polydioxanone (PDO) device is manufactured to facilitate ligation of vascular tissue during surgery. The device must provide sufficient mechanical performance throughout the healing period. Therefore, degradation and mechanical performance of the device are investigated as a function of in vivo and in vitro aging. During aging the PDO device released cyclic and linear water-soluble products. In vivo aging resulted in higher relative number of linear oligomers in comparison to in vitro aging. A major loss of mechanical performance is observed after only 10 days in vivo a...
Easley JT, McGilvray KC, Hendrickson DA, Bruemmer J, Hackett ES.To determine the temperature of a vessel sealer and divider device during unilateral paralumbar laparoscopic ovariectomy in standing, sedated mares. Methods: Prospective study. Methods: Fifteen healthy research mares. Methods: Healthy mares with normal ovarian palpation and ultrasonographic appearance were enrolled. Horses were restrained in standing stocks and sedated. A right or left paralumbar ovariectomy was performed with a laparoscopic portal and 2 instrument portals. Ovaries were excised with traumatic forceps and a blunt tip vessel sealer and divider. Temperatures of the vessel sealer ...
Verwilghen D, Ponthier J, Van Galen G, Salciccia A, Sandersen C, Serteyn D, Grulke S.Radial extracorporeal shockwave therapy (ESWT) is widely used in equine practice for the treatment of orthopedic problems. However, its original use as a lithotripsy device in human and canine urology led us to postulate that it could be used as an alternative to the surgical treatment of urethral calculi in horses. Objective: Radial ESWT can easily and safely fragment calculi in the distal urethra of the horse. Methods: Two postmortem cases and 1 live case of obstructive urinary disease admitted at the Veterinary Teaching Hospital of Liege. Methods: A radial shockwave device was directly appl...
Sakes A, Arkenbout EA, Jelínek F, van der Kolk JH, Breedveld P.A new paradigm of surgical treatment of equine Cushing's disease has been developed using the vascular system combined with a flexible morcellation instrument to reach the pituitary gland. Objective: The goal was twofold: (1) to design, prototype, and test an instrument that can reach the pituitary gland using the vascular system unique to equids and (2) to test the feasibility of the endovascular approach. Methods: The morcellator consists of a radial rotating cutting blade for tissue resection, a flexible shaft incorporating a cable drive for flexible actuation, and central morcellated tissu...
Tithof PK, Rebhun WC, Dietze AE.A linear array 5 mHz ultrasonic scanner was used to diagnose aorto-iliac thrombosis in a 3 year old Standardbred gelding. There are no reports in the literature of utilization of ultrasonography for visualization of an aortic thrombus. The technique is fairly non-invasive, requiring only a rectal examination with a linear array probe. Arteriography is the only other method described for actual visualization of a thrombus. This procedure is technically difficult and highly invasive.
Hoskinson JJ, Wooten P, Evans R.Nonsurgical, percutaneous, transvenous removal of a catheter fragment embolus was performed in a 14-day-old Thoroughbred foal. A basket retrieval catheter was introduced into the jugular vein and manipulated under fluoroscopic guidance to remove the fragment from the right side of the heart. Percutaneous retrieval should be considered as an alternative to thoracotomy for retrieval of intracardiac or intravascular foreign bodies.
Auer JA, Watkins JP.In recent years fracture fixation in the horse has changed significantly. New devices, mainly adapted from the human field, have been successfully introduced into large animal surgery. Examples of such implants include the DCS/DHS implant system, the self-tapping screw, the cannulated screw, and the pinless external fixator. However, new devices have also been developed exclusively for equine fracture management, including the interlocking intramedullary nail and the external skeletal fixation device. With these devices the surgeon has more options for repairing fractures in horses. Neverthele...
Beasley B, Perlini M.The objective of this paper is to describe a novel technique for handling an ultrasound transducer while performing sterile ultrasound guided procedures. This novel technique involves placement of the transducer inside the sterile glove on the hand of the operator. This technique allows the operator access to use of both hands without having to pass the transducer to an assistant.
Beroza GA.A device and technique for intra-operative gastro-intestinal lavage was developed to remove ingesta from the stomach, large intestine and caecum of horses. The Gastro-Intestinal Lavage System (GILS) is composed of a nozzle connected to both water under pressure and suction. Water jets across an intake portal in the nozzle, breaks up food and debris within the nozzle and is evacuated under negative pressure into the aspirating tube which is connected to a collection drum. The GILS nozzle was introduced at the pelvic flexure through a sterile enterotomy cuff and plastic sleeve. Water was first a...
Tranquilli WJ, Manohar M, Thurmon JC, Manning JP.Long-term catheterisation of the coronary sinus using a specially designed catheter was accomplished in 6 ponies via a right lateral thoracotomy. The catheter comprised a 10 to 12 cm long stiff segment (Teflon) joined to a 100 cm length of pliable medical grade (vinyl) tubing. Catheters were kept functional up to 10 weeks postoperatively. Location of the catheter tip was verified by determining the oxygen tension of anaerobically withdrawn blood samples. Normal values of oxygen tension of the coronary sinus blood in ponies were similar to those reported for the dog, whereas oxygen content was ...
Steffey EP, Berry JD.Inspiratory flow rates were measured and compared in an equine intermittent positive pressure breathing-anesthesia delivery apparatus powered by a positive phase ventilator, a positive-negative phase ventilator, and a modified positive phase ventilator with automatic flow acceleration at driving pressures of 2,600, 4,400, and 5,200 mm of Hg (50, 85, and 100 psi). The last-named apparatus consistently produced the highest flows for a given ventilator setting and driving pressure. Regardless of the unit used, the greater driving pressures and high ventilator range settings produced the greatest ...