Analyze Diet

Topic:Medical Device

Medical devices in equine care encompass a range of tools and technologies designed to diagnose, monitor, or treat medical conditions in horses. These devices can include imaging equipment, such as ultrasound and radiography machines, which help in visualizing internal structures; wearable sensors for tracking vital signs and activity levels; and therapeutic devices, such as laser therapy equipment, used in rehabilitation. Medical devices are integral to equine veterinary practice, aiding in the assessment of health status, guiding treatment decisions, and monitoring recovery. This page compiles peer-reviewed research studies and scholarly articles that explore the development, application, and impact of medical devices in equine medicine.
Clinical evaluation of an end-tidal target-controlled infusion closed-loop system for isoflurane administration in horses undergoing surgical procedures.
Veterinary journal (London, England : 1997)    July 8, 2011   Volume 192, Issue 2 206-211 doi: 10.1016/j.tvjl.2011.06.001
Franci P, Bertamini A, Bertamini O, Pilla T, Busetto R.A new volatile anaesthetic agent delivery system was tested in 15 horses undergoing scheduled surgical procedures. The delivery system consisted of a laptop computer (with dedicated software), a computer-controlled syringe driver (loaded with liquid isoflurane) connected to the inspiratory arm of a large-animal circle breathing system and a respiratory gas monitor, providing isoflurane end-tidal concentrations (ET(measured)) every 20 s to the computer. Following induction and connection to the breathing system, mechanical ventilation was started. The bodyweight (BW), fresh gas flow, breathing ...
Invited guest editorial in response to: Estimated operator exposure for hand holding portable X-ray units during imaging of the equine distal extremity: Veterinary Radiology & Ultrasound 2011;52:121-124. Barbee D.No abstract available
Comparison of water manometry to 2 commercial electronic pressure monitors for central venous pressure measurement in horses.
Journal of veterinary internal medicine    January 31, 2011   Volume 25, Issue 2 303-306 doi: 10.1111/j.1939-1676.2010.0670.x
Norton JL, Nolen-Walston RD, Underwood C, Slack J, Boston R, Dallap BL.Central venous pressure (CVP) customarily has been measured in veterinary patients with water manometry. However, many institutions are now using stallside electronic monitors in both anesthesia and intensive care units for many aspects of patient monitoring. Objective: Electronic stall side monitoring devices will agree with water manometry for measurement of CVP in horses. Methods: Ten healthy adult horses from the university research herd. Methods: Central venous catheters were placed routinely, and measurements were obtained in triplicate with each of the 3 methods every 12 hours for 3 day...
Percutaneous transcatheter closure of an aorto-cardiac fistula in a Thoroughbred stallion using an Amplatzer occluder device.
Journal of veterinary internal medicine    May 11, 2010   Volume 24, Issue 4 994-998 doi: 10.1111/j.1939-1676.2010.0523.x
Javsicas LH, Giguère S, Maisenbacher HW, Schmidt M, Frederick JD, Conway JA, Estrada AH.No abstract available
Complications of laparoscopic surgery.
The Veterinary clinics of North America. Equine practice    February 11, 2009   Volume 24, Issue 3 557-viii doi: 10.1016/j.cveq.2008.09.003
Hendrickson DA.This article describes surgical complications associated with laparoscopy, how to avoid them, how to recognize them if they do happen, and how to deal with them in the most expedient method possible. Complications of sedation, anesthesia, positioning, the general surgical approach, and complications associated with specific surgical procedures are examined. The best defense against surgical complications is a thorough training program and an understanding of anatomy that will help the surgeon work in the three-dimensional environment while being limited to two dimensions on the monitor. The au...
The use of radial extracorporeal shockwave therapy in the treatment of urethral urolithiasis in the horse: a preliminary study.
Journal of veterinary internal medicine    November 13, 2008   Volume 22, Issue 6 1449-1451 doi: 10.1111/j.1939-1676.2008.0197.x
Verwilghen D, Ponthier J, Van Galen G, Salciccia A, Sandersen C, Serteyn D, Grulke S.Radial extracorporeal shockwave therapy (ESWT) is widely used in equine practice for the treatment of orthopedic problems. However, its original use as a lithotripsy device in human and canine urology led us to postulate that it could be used as an alternative to the surgical treatment of urethral calculi in horses. Objective: Radial ESWT can easily and safely fragment calculi in the distal urethra of the horse. Methods: Two postmortem cases and 1 live case of obstructive urinary disease admitted at the Veterinary Teaching Hospital of Liege. Methods: A radial shockwave device was directly appl...
Device for unobtrusive drug administration and blood sampling in horses recovering from anaesthesia.
The Veterinary record    September 9, 2008   Volume 163, Issue 10 303-304 doi: 10.1136/vr.163.10.303
Clutton RE.No abstract available
[Mini-invasive distraction technique for treatment of severe ankle and foot deformities secondary to ischemic contracture of the leg].
Zhonghua wai ke za zhi [Chinese journal of surgery]    June 21, 2006   Volume 44, Issue 8 547-550 
Qin SH, Sun L, Zheng XJ.To explore the Ilizarov mini-invasive distraction technique for the treatment of severer ankle and foot deformities secondary to ischemic contracture of the leg. Methods: Based on the tension-stress low of Ilizarov, a serial of adjustable three dimensions external distractive instrument was developed in our department. From April 2002 to March 2004, 8 patients with ankle and foot deformities secondary to ischemic contracture of the leg induced by trauma and fracture were treated with the distractive instrument. Of them, 4 patient were male and 4 female, aged from 13 to 31 years with an average...
Early clinical experience with a new tubular equine pericardial stentless aortic valve.
The heart surgery forum    April 1, 2005   Volume 7, Issue 5 E498-E502 doi: 10.1532/HSF98.20041087
Eckstein FS, Tevaearai H, Keller D, Schmidli J, Immer FF, Seiler C, Saner H, Carrel TP.This study details a single-center experience with the 3F Therapeutics stentless aortic bioprosthesis(investigational device) and is part of a prospective,nonrandomized worldwide multicenter study. We assessed the implantation procedure and the valve's efficacy in terms of early mortality and morbidity and early echocardiographic valve performance. Methods: Between June 2001 and March 2004, 24 patients (14 men/10 women) underwent aortic valve replacement(AVR) with a 3F valve. Mean age was 72 +/- 13 years(range, 31-88 years). Combined revascularization was performed in 12 patients; 1 patient re...
Respiratory applications for the future: one perspective.
The Veterinary clinics of North America. Equine practice    January 22, 2005   Volume 17, Issue 2 335-viii doi: 10.1016/s0749-0739(17)30066-4
Hoffman AM.Respiratory diagnostic instruments previously available only to referral centers should be converted into miniature, portable, wireless medical devices for use in practice. Internet and wireless connections of these instruments should expedite the process of seeking second opinions and in general information sharing. We are moving into a world of greater objectivity that should free us from speculation in some areas, yet open new avenues for research and innovation in others.
History and instrumentation of laparoscopic surgery.
The Veterinary clinics of North America. Equine practice    February 27, 2004   Volume 16, Issue 2 233-v doi: 10.1016/s0749-0739(17)30102-5
Hendrickson DA.Equine surgery continues to benefit from advances in endoscopic surgical techniques. Much of what we have learned in equine endoscopy comes from techniques used in humans. Descriptions of the normal anatomy of the standing horse and advances in instrumentation have improved our ability to perform laparoscopic surgery in standing and dorsally recumbent horses. This article describes the history of laparoscopy and available instrumentation.
History, instrumentation, and techniques of flexible endoscopic laser surgery in horses.
The Veterinary clinics of North America. Equine practice    February 27, 2004   Volume 16, Issue 2 251-268 doi: 10.1016/s0749-0739(17)30103-7
Blikslager AT, Tate LP.There are clearly a number of applications for which flexible endoscopic laser surgery has become the state of the art in equine surgery, and the Nd:YAG laser seems to be the most versatile instrument for this type of surgery. Nevertheless, it is critical to understand the advantages and disadvantages of each laser technique. For example, the Nd:YAG laser used in a noncontact fashion seems to be superior when ablation of tissue is required such as treatment of upper airway masses. Conversely, contact Nd:YAG laser techniques have proven themselves to be superior when more precise cutting is adv...
Development and testing of a modular strain measurement clip.
Journal of biomechanics    October 3, 2003   Volume 36, Issue 11 1669-1674 doi: 10.1016/s0021-9290(03)00173-8
Whan G, Phillips J, Bullock S, Runciman RJ, Pearce S, Hurtig M.A novel, multi-use, low-stiffness and low-cost transducer for measuring in vitro strains has been developed and tested. Currently available strain measurement methods are either too expensive, too complicated or too inflexible for multi-use strain measurement. The stainless-steel modular strain measurement clip introduced here was instrumented with four 350 Omega axial strain gauges in a full Wheatstone bridge configuration to take advantage of commonly available strain gauge amplifier equipment. Adjustable extension arms were designed to allow greater application versatility. The clip was cal...
Recent advances in inhalation anesthesia.
The Veterinary clinics of North America. Equine practice    June 18, 2002   Volume 18, Issue 1 159-168 doi: 10.1016/s0749-0739(01)00007-4
Steffey EP.Both desflurane and sevoflurane offer theoretical and practical advantages over other inhalation anesthetics for horses. The lower solubility of both agents provides improved control of delivery and helps to counteract the confounding influence of the voluminous patient breathing circuit commonly used for anesthetizing horses. The lower solubility should account for faster rates of recovery compared with the older agents; whether or not the quality of recovery differs remains to be objectively evaluated in a broad range of circumstances. The pharmacodynamic effects are, in large part, similar ...
Ankle-foot orthoses: effect on gait in children with cerebral palsy.
Disability and rehabilitation    May 23, 2002   Volume 24, Issue 7 345-347 doi: 10.1080/0963820110090724
Dursun E, Dursun N, Alican D.In this study our aim was to evaluate the effectiveness of Ankle-Foot Orthoses (AFOs) on gait function in patients with spastic cerebral palsy for whom orthoses were indicated to control dynamic equines deformity. Methods: Twenty-four spastic cerebral palsied patients with dynamic equines deformity were included in the study. Videotape recordings were performed to each patient on the same day with barefoot and AFOs. Temporal distance factors including velocity, cadence, stride length, stride width and Clinical Gait Assessment Score (CGAS) were compared across two conditions. Results: The use o...
Temporary transvenous atrial pacing in horses: threshold determination.
Equine veterinary journal    May 16, 2001   Volume 33, Issue 3 290-295 doi: 10.2746/042516401776249633
van Loon G, Laevens H, Deprez P.The purpose of this study was to perform temporary atrial pacing and to determine the atrial strength-duration (S-D) curve which displays the minimal pulse intensity necessary to achieve atrial capture. In 7 horses, atrial pacing was applied using a temporary pacing catheter and a pacemaker as electrical pulse generator. Using the stimulus reduction method, 3 approaches for atrial threshold determination were used. With the fixed pulse width method, at several pulse widths, the corresponding minimal amplitudes to achieve capture were determined, describing an S-D curve. With the fixed amplitud...
Laryngoplasty: a novel prosthesis.
Equine veterinary journal    February 8, 2000   Volume 32, Issue 1 5-6 doi: 10.2746/042516400777612026
Robertson JT.No abstract available
Instrumentation and techniques in equine fracture fixation.
The Veterinary clinics of North America. Equine practice    August 1, 1996   Volume 12, Issue 2 283-302 doi: 10.1016/s0749-0739(17)30283-3
Auer JA, Watkins JP.In recent years fracture fixation in the horse has changed significantly. New devices, mainly adapted from the human field, have been successfully introduced into large animal surgery. Examples of such implants include the DCS/DHS implant system, the self-tapping screw, the cannulated screw, and the pinless external fixator. However, new devices have also been developed exclusively for equine fracture management, including the interlocking intramedullary nail and the external skeletal fixation device. With these devices the surgeon has more options for repairing fractures in horses. Neverthele...
Advances in equine arthroscopy.
The Veterinary clinics of North America. Equine practice    August 1, 1996   Volume 12, Issue 2 261-281 doi: 10.1016/s0749-0739(17)30282-1
Trotter GW, McIlwraith CW.Surgical procedures completed under arthroscopic guidance have become commonplace in many equine practices and have largely replaced surgery using arthrotomy incisions. With a limited amount of equipment, numerous diagnostic and surgical procedures can be completed. Surgeons need to become familiar with regional and intraarticular (intrasynovial) anatomy to ensure that proper surgical approaches are used, access to the lesion will be realized, and potential complications will be minimized. Specialized motorized instruments and surgical lasers are now available and may be useful in the treatmen...
A transtracheal catheter for recording the static tracheal pressure in the exercising horse.
Acta veterinaria Scandinavica    January 1, 1995   Volume 36, Issue 4 461-473 doi: 10.1186/BF03547661
Roethlisberger-Holm K, Roepstorff L, Obel N.After giving an account of the principles of pressure measurement in flowing air and a review of the literature on tracheal catheters, the authors describe the construction, the introduction and the function of their own transtracheal catheter. This is a teflon catheter with several side-ports which is introduced into the cervical trachea by a guide technique. After introduction, the catheter is stiffened by the insertion of 2 steel wires. The catheter was studied in model experiments concerning: a) the ability to measure the static pressure in flowing air, and b) the dynamic accuracy of a rec...
Viscosupplementation: a new concept in the treatment of osteoarthritis.
The Journal of rheumatology. Supplement    August 1, 1993   Volume 39 3-9 
Balazs EA, Denlinger JL.Viscosupplementation is a new medical concept that has as its therapeutic goal the restoration of rheological homeostasis in pathological structures such as osteoarthritic joints. When the normal viscoelasticity of a solid tissue compartment or the elastoviscosity of a liquid tissue compartment is decreased under pathological conditions, normal function and regenerative processes are impaired. By introducing viscosupplementary devices, the normal rheological state of such compartments is restored or augmented. These devices stay in the tissue compartment for various periods of time, depending ...
Flow reversal through a Mark III halothane vaporizer.
British journal of anaesthesia    August 1, 1993   Volume 71, Issue 2 303-304 doi: 10.1093/bja/71.2.303
Gregg AS, Jones RS, Snowdon SL.A fault in the assembly of a Matrix Large Animal Circle anaesthetic machine resulted in reversal of fresh gas flow through the vaporizer. The fault was discovered only after the sudden development of excessive depth of anaesthesia in two equine patients. Laboratory investigations were conducted to determine the effect of flow reversal on vaporizer output. Results indicated that output concentration was approximately doubled under these conditions.
Comparison of applanation tonometers in dogs and horses.
Journal of the American Veterinary Medical Association    August 1, 1992   Volume 201, Issue 3 430-433 
Dziezyc J, Millichamp NJ, Smith WB.Two Mackay-Marg tonometers and 2 Tono-Pen tonometers were evaluated in eyes in which intraocular pressure (IOP) had been altered and measured by use of a manometer. Eyes of anesthetized dogs and enucleated horse eyes were used. Compared with the manometer, none of the tonometers accurately measured IOP over the range between 0 and 100 mm of Hg. However at manometer measurements from 0 to 30 mm of Hg, several of the tonometers accurately measured IOP. In addition, significant differences were observed when the measurement accuracy of one tonometer was compared with that of another, especially a...
A percutaneous transtracheal catheter system for improved oxygenation in foals with respiratory distress.
Equine veterinary journal    May 1, 1992   Volume 24, Issue 3 239-241 doi: 10.1111/j.2042-3306.1992.tb02822.x
Hoffman AM, Viel L.No abstract available
Nonsurgical removal of a catheter embolus from the heart of a foal.
Journal of the American Veterinary Medical Association    July 15, 1991   Volume 199, Issue 2 233-235 
Hoskinson JJ, Wooten P, Evans R.Nonsurgical, percutaneous, transvenous removal of a catheter fragment embolus was performed in a 14-day-old Thoroughbred foal. A basket retrieval catheter was introduced into the jugular vein and manipulated under fluoroscopic guidance to remove the fragment from the right side of the heart. Percutaneous retrieval should be considered as an alternative to thoracotomy for retrieval of intracardiac or intravascular foreign bodies.
Pulse oximetry in horses.
Veterinary surgery : VS    May 1, 1990   Volume 19, Issue 3 243-248 doi: 10.1111/j.1532-950x.1990.tb01179.x
Whitehair KJ, Watney GC, Leith DE, Debowes RM.The clinical usefulness of two pulse oximeters was evaluated at two probe sites in nine anesthetized horses. The hemoglobin saturation determined by the pulse oximeters (SaOx) was compared with the hemoglobin saturation calculated from the measured arterial oxygen tension (SaO2). The mean and standard deviation (SD) were calculated from the differences in saturation measurements, over the saturation range of 80% to 100%, for each oximeter used at the tongue probe site and for one oximeter used at the ear. The oximeter results tended to underestimate the SaO2 with mean differences of -3.7% on t...
Historical highlights in cardiac pacing. Geddes LA.The benchmarks in cardiac pacing are identified, beginning with F. Steiner (1871), who rhythmically stimulated the chloroform-arrested hearts of 3 horses, 1 donkey, 10 dogs, 14 cats, and 8 rabbits. The chloroform-arrested heart in human subjects was paced by T. Greene in the following year (1872) in the UK. In 1882, H. Ziemssen in Germany applied cardiac pacing to a 42-year old woman who had a large defect in the anterior left chest wall subsequent to resection of an enchondroma. Intentional cardiac pacing did not occur until 1932, when A.A. Hyman in the US demonstrated that cardiac pacing cou...
A device and technique for gastrointestinal lavage in the horse.
Equine veterinary journal. Supplement    June 1, 1989   Issue 7 94-97 doi: 10.1111/j.2042-3306.1989.tb05665.x
Beroza GA.A device and technique for intra-operative gastro-intestinal lavage was developed to remove ingesta from the stomach, large intestine and caecum of horses. The Gastro-Intestinal Lavage System (GILS) is composed of a nozzle connected to both water under pressure and suction. Water jets across an intake portal in the nozzle, breaks up food and debris within the nozzle and is evacuated under negative pressure into the aspirating tube which is connected to a collection drum. The GILS nozzle was introduced at the pelvic flexure through a sterile enterotomy cuff and plastic sleeve. Water was first a...
A preliminary investigation of the effect of selected electromagnetic field devices on healing of cannon bone osteotomies in horses.
Equine veterinary journal    May 1, 1989   Volume 21, Issue 3 201-205 doi: 10.1111/j.2042-3306.1989.tb02145.x
Sanders-Shamis M, Bramlage LR, Weisbrode SE, Gabel AA.The effect of electrical stimulation by means of selected electromagnetic field devices on healing of cannon bone osteotomies in horses was examined. The defects were created as 3 cm x 1 mm longitudinal osteotomies through the dorsal cortices of the mid-metacarpi/metatarsi of adult horses. This type of defect would asses bone healing in a situation similar to an acute, stable fracture of the cortex. Three electromagnetic devices of different design were tested in three different groups of horses. Healing was evaluated radiographically and histologically. Results showed that osteotomies treated...
[Indirect blood pressure determination in the horse with the Dinamap 1255 research monitor].
Tierarztliche Praxis    January 1, 1988   Volume 16, Issue 4 373-376 
Fritsch R, Hausmann R.In 26 horses measurings of blood pressure, using the Dinamap 1255 research monitor, were performed and compared for accuracy with blood pressure values obtained by direct measurement in the arteria carotis. It was found that oscillometrically ascertained initial blood values in standing horses have a sufficient correlation to initial blood pressure values obtained by direct measurement. But every blood pressure change is registered too late, when using the oscillometric blood pressure apparatus. This temporal delay becomes unacceptable, when a considerable increase in blood pressure occurs. A ...