Medical devices in equine care encompass a range of tools and technologies designed to diagnose, monitor, or treat medical conditions in horses. These devices can include imaging equipment, such as ultrasound and radiography machines, which help in visualizing internal structures; wearable sensors for tracking vital signs and activity levels; and therapeutic devices, such as laser therapy equipment, used in rehabilitation. Medical devices are integral to equine veterinary practice, aiding in the assessment of health status, guiding treatment decisions, and monitoring recovery. This page compiles peer-reviewed research studies and scholarly articles that explore the development, application, and impact of medical devices in equine medicine.
Tithof PK, Rebhun WC, Dietze AE.A linear array 5 mHz ultrasonic scanner was used to diagnose aorto-iliac thrombosis in a 3 year old Standardbred gelding. There are no reports in the literature of utilization of ultrasonography for visualization of an aortic thrombus. The technique is fairly non-invasive, requiring only a rectal examination with a linear array probe. Arteriography is the only other method described for actual visualization of a thrombus. This procedure is technically difficult and highly invasive.
Brownlow MA, Turner DM, Hutchins DR.An inhalation anaesthetic apparatus for the horse is described and the physiological concepts pertaining to its design presented. The internal diameter of all breathing components is 6.2 cm with no change in cross sectional area throughout the circle system. The soda lime capacity is 25 litres (approximately 20 kg). In the horse, which is apparently predisposed to alveolar hypoventilation during inhalation anaesthesia, it is apparent that adequate anaesthetic apparatus design should be directed towards minimising resistance and dead space and providing maximal and efficient carbon dioxide elim...
McDonell WN, Pascoe PJ, Lindsay WA, Burgess ML.The use of the wick catheter to measure intracompartmental muscle pressure in equine muscle was documented. The presence of muscle compartments involving the extensor carpi radialis muscle and the long head of the triceps brachii was demonstrated by anatomic dissection and radiographic technique. The wick catheter was capable of accurately measuring pressures within both of these compartments. Furthermore, the wick catheter was sensitive to pressure changes resulting from external compression of muscle compartments. Manipulation of systemic blood pressure and PaCO2 in 1 anesthetized horse did ...
Tranquilli WJ, Manohar M, Thurmon JC, Manning JP.Long-term catheterisation of the coronary sinus using a specially designed catheter was accomplished in 6 ponies via a right lateral thoracotomy. The catheter comprised a 10 to 12 cm long stiff segment (Teflon) joined to a 100 cm length of pliable medical grade (vinyl) tubing. Catheters were kept functional up to 10 weeks postoperatively. Location of the catheter tip was verified by determining the oxygen tension of anaerobically withdrawn blood samples. Normal values of oxygen tension of the coronary sinus blood in ponies were similar to those reported for the dog, whereas oxygen content was ...
Scott EA, Sandler GA.Electromagnetic blood flowmeters and flow probes are used to measure blood flow in blood vessels throughout the circulatory system. The principle of this measuring device is based on laws of electromagnetic induction discovered in the 19th century. The instrument has been predominantly used in research, but is presently used in human cardiovascular units to measure blood flow in blood vessels, and in prosthesis in conjection with cardiovascular surgical procedures. Electromagnetic flow equipment provides the most accurate measurement (in vivo) of blood flow available, both for acute and chroni...
Steffey EP, Berry JD.Inspiratory flow rates were measured and compared in an equine intermittent positive pressure breathing-anesthesia delivery apparatus powered by a positive phase ventilator, a positive-negative phase ventilator, and a modified positive phase ventilator with automatic flow acceleration at driving pressures of 2,600, 4,400, and 5,200 mm of Hg (50, 85, and 100 psi). The last-named apparatus consistently produced the highest flows for a given ventilator setting and driving pressure. Regardless of the unit used, the greater driving pressures and high ventilator range settings produced the greatest ...
McDonell WN, Pascoe PJ, Lindsay WA, Burgess ML.The use of the wick catheter to measure intracompartmental muscle pressure in equine muscle was documented. The presence of muscle compartments involving the extensor carpi radialis muscle and the long head of the triceps brachii was demonstrated by anatomic dissection and radiographic technique. The wick catheter was capable of accurately measuring pressures within both of these compartments. Furthermore, the wick catheter was sensitive to pressure changes resulting from external compression of muscle compartments. Manipulation of systemic blood pressure and PaCO2 in 1 anesthetized horse did ...
Gregg AS, Jones RS, Snowdon SL.A fault in the assembly of a Matrix Large Animal Circle anaesthetic machine resulted in reversal of fresh gas flow through the vaporizer. The fault was discovered only after the sudden development of excessive depth of anaesthesia in two equine patients. Laboratory investigations were conducted to determine the effect of flow reversal on vaporizer output. Results indicated that output concentration was approximately doubled under these conditions.
Neelis DA, Roberts GD.The many advancements in ultrasound technology, including spatial compounding, harmonic imaging, multidimensional and extended field-of-view images, and improvements in transducer capabilities, are used to enhance the ultrasonographic examination of the equine patient. The improvements in software and hardware capabilities help overcome artifacts, improve image quality, and allow better documentation of the examination for follow-up studies. In addition, the ability of smaller, more portable machines to produce better images is ideal for the ambulatory practice setting.
Whan G, Phillips J, Bullock S, Runciman RJ, Pearce S, Hurtig M.A novel, multi-use, low-stiffness and low-cost transducer for measuring in vitro strains has been developed and tested. Currently available strain measurement methods are either too expensive, too complicated or too inflexible for multi-use strain measurement. The stainless-steel modular strain measurement clip introduced here was instrumented with four 350 Omega axial strain gauges in a full Wheatstone bridge configuration to take advantage of commonly available strain gauge amplifier equipment. Adjustable extension arms were designed to allow greater application versatility. The clip was cal...
Blikslager AT, Tate LP.There are clearly a number of applications for which flexible endoscopic laser surgery has become the state of the art in equine surgery, and the Nd:YAG laser seems to be the most versatile instrument for this type of surgery. Nevertheless, it is critical to understand the advantages and disadvantages of each laser technique. For example, the Nd:YAG laser used in a noncontact fashion seems to be superior when ablation of tissue is required such as treatment of upper airway masses. Conversely, contact Nd:YAG laser techniques have proven themselves to be superior when more precise cutting is adv...
Roethlisberger-Holm K, Roepstorff L, Obel N.After giving an account of the principles of pressure measurement in flowing air and a review of the literature on tracheal catheters, the authors describe the construction, the introduction and the function of their own transtracheal catheter. This is a teflon catheter with several side-ports which is introduced into the cervical trachea by a guide technique. After introduction, the catheter is stiffened by the insertion of 2 steel wires. The catheter was studied in model experiments concerning: a) the ability to measure the static pressure in flowing air, and b) the dynamic accuracy of a rec...
Gregson R, Clutton RE.A 7-year-old gelded Irish sports horse weighing 650 kg was anesthetized on 2 consecutive days for lavage of a septic right radio-carpal joint. On both occasions the endotracheal tube connector, which had been bound in medical tape to produce an airtight seal, functioned as a unidirectional valve during mechanical ventilation, retarding expiration, imposing positive end expiratory pressure (PEEP), and probably continuous positive airway pressure (CPAP). The equipment dysfunction was not identified on either occasion despite close inspection prompted by progressive increases in airway pressure a...
Scott EA, Sandler GA.Electromagnetic blood flowmeters and flow probes are used to measure blood flow in blood vessels throughout the circulatory system. The principle of this measuring device is based on laws of electromagnetic induction discovered in the 19th century. The instrument has been predominantly used in research, but is presently used in human cardiovascular units to measure blood flow in blood vessels, and in prosthesis in conjection with cardiovascular surgical procedures. Electromagnetic flow equipment provides the most accurate measurement (in vivo) of blood flow available, both for acute and chroni...
Brownlow MA, Turner DM, Hutchins DR.An inhalation anaesthetic apparatus for the horse is described and the physiological concepts pertaining to its design presented. The internal diameter of all breathing components is 6.2 cm with no change in cross sectional area throughout the circle system. The soda lime capacity is 25 litres (approximately 20 kg). In the horse, which is apparently predisposed to alveolar hypoventilation during inhalation anaesthesia, it is apparent that adequate anaesthetic apparatus design should be directed towards minimising resistance and dead space and providing maximal and efficient carbon dioxide elim...
Fritsch R, Hausmann R.In 26 horses measurings of blood pressure, using the Dinamap 1255 research monitor, were performed and compared for accuracy with blood pressure values obtained by direct measurement in the arteria carotis. It was found that oscillometrically ascertained initial blood values in standing horses have a sufficient correlation to initial blood pressure values obtained by direct measurement. But every blood pressure change is registered too late, when using the oscillometric blood pressure apparatus. This temporal delay becomes unacceptable, when a considerable increase in blood pressure occurs. A ...
Angeluci GC, Ricci CL, Passareli JVGC, Estanho GJG, Oliveira AS, Santos SGA, Giuffrida R, Rodrigues M, Andrade SF.Measurement of the intraocular pressure (IOP) is a useful diagnostic tool in equine ophthalmology. Handheld tonometers, such as Tonovet and Tonovet Plus (rebound), Tono-Pen AVIA Vet (applanation), and Kowa HA-2 (applanation using the Goldmann methodology) are used to obtain IOP measurements in veterinary medicine. Objective: To compare and evaluate the accuracy of four handheld tonometers in measuring IOP using different methodologies in healthy horses. Methods: In vivo experiment and cross-sectional survey of healthy horses. Methods: Intraocular pressure was measured in 72 eyes of 36 horses. ...
Gandini M, Giusto G.In jejunocaecal anastomosis leaving a necrotic ileal stump has been implicated in complications and poor outcomes. Elective inversion of the necrotic stump using a nasogastric tube has been previously described, although this procedure can be cumbersome and can cause caecocolic orifice occlusion. Objective: To describe the use of a new device for elective inversion of necrotic ileal stumps. Methods: Case report. Methods: Details of the four horses that underwent intestinal resection and anastomosis with elective inversion of the ileal stump were retrieved from their medical records. For each c...
Dunay MP, Németh T, Makra Z, Izing S, Bodó G.In the present series of cases, 8 laparoscopic cryptorchidectomies and 4 laparoscopic ovariectomies were carried out in sedated standing horses. Sedation involved a lesser anaesthesiological risk than does general anaesthesia. As compared to laparotomic exposure, the minimally invasive laparoscopic intervention provided better visualisation, shorter operative time and faster recovery. The blood vessels supplying the testes and ovaries and the suspensory ligaments of the organs were sealed and cut with EnSeal®, an adaptive bipolar electrosurgical blood vessel- and tissue-sealing device. The cl...
Qin SH, Sun L, Zheng XJ.To explore the Ilizarov mini-invasive distraction technique for the treatment of severer ankle and foot deformities secondary to ischemic contracture of the leg. Methods: Based on the tension-stress low of Ilizarov, a serial of adjustable three dimensions external distractive instrument was developed in our department. From April 2002 to March 2004, 8 patients with ankle and foot deformities secondary to ischemic contracture of the leg induced by trauma and fracture were treated with the distractive instrument. Of them, 4 patient were male and 4 female, aged from 13 to 31 years with an average...
Sakes A, Arkenbout EA, Jelínek F, van der Kolk JH, Breedveld P.A new paradigm of surgical treatment of equine Cushing's disease has been developed using the vascular system combined with a flexible morcellation instrument to reach the pituitary gland. Objective: The goal was twofold: (1) to design, prototype, and test an instrument that can reach the pituitary gland using the vascular system unique to equids and (2) to test the feasibility of the endovascular approach. Methods: The morcellator consists of a radial rotating cutting blade for tissue resection, a flexible shaft incorporating a cable drive for flexible actuation, and central morcellated tissu...
Geddes LA.The benchmarks in cardiac pacing are identified, beginning with F. Steiner (1871), who rhythmically stimulated the chloroform-arrested hearts of 3 horses, 1 donkey, 10 dogs, 14 cats, and 8 rabbits. The chloroform-arrested heart in human subjects was paced by T. Greene in the following year (1872) in the UK. In 1882, H. Ziemssen in Germany applied cardiac pacing to a 42-year old woman who had a large defect in the anterior left chest wall subsequent to resection of an enchondroma. Intentional cardiac pacing did not occur until 1932, when A.A. Hyman in the US demonstrated that cardiac pacing cou...
Ahern BJ, Lim YW, van Eps A, Franklin S.To determine the effect of a prototype dynamic laryngoplasty system (DLPS) on arytenoid abduction. Methods: In vitro experimental. Methods: Ten equine larynges. Methods: Dissected larynges were mounted, and the right arytenoid was maximally abducted for testing. A left-sided laryngoplasty (LP) was performed by using a strand of No. 2 FiberWire and a FASTakII anchor. Phase 1 involved tightening the suture, without the DLPS device in place, in 1-mm increments and acquiring a digital image of the rima glottidis at each increment. Phase 2 involved tying the suture with the DLPS in place at a left ...
Gonzalez-Cantero JL, Del Valle Diéguez M, Monteserín Matesanz C, Saura Lorente J, Villoria Medina F, Fortea Gil F, Castro Reyes E.We report a case of traumatic intracranial carotid artery pseudoaneurysm treated with an equine pericardium-covered stent. The patient was admitted to the Emergency Department after sustaining severe polytrauma in a motor vehicle accident. A cavernous carotid pseudoaneurysm was detected after an episode of massive epistaxis that required emergent nasal packing. Treatment with parent vessel sacrifice was ruled out after an unfavourable balloon test occlusion. We opted for an equine pericardium-covered stent as a means to immediately seal the wall defect in the setting of massive bleeding second...
Norton JL, Nolen-Walston RD, Underwood C, Slack J, Boston R, Dallap BL.Central venous pressure (CVP) customarily has been measured in veterinary patients with water manometry. However, many institutions are now using stallside electronic monitors in both anesthesia and intensive care units for many aspects of patient monitoring. Objective: Electronic stall side monitoring devices will agree with water manometry for measurement of CVP in horses. Methods: Ten healthy adult horses from the university research herd. Methods: Central venous catheters were placed routinely, and measurements were obtained in triplicate with each of the 3 methods every 12 hours for 3 day...