Analyze Diet

Topic:Biomechanics

Biomechanics in horses refers to the study of the mechanical principles that govern movement and physical function in equine species. This field encompasses the analysis of gait, locomotion, and the forces exerted by and upon the horse's musculoskeletal system. Biomechanical studies often involve the use of motion capture technology, force plates, and computer modeling to assess how horses move and how various factors, such as conformation, training, and health status, influence their performance and soundness. Research in equine biomechanics contributes to understanding injury prevention, rehabilitation, and performance optimization. This page compiles peer-reviewed research studies and scholarly articles that explore the mechanics of movement, the impact of external and internal forces, and the applications of biomechanical analysis in equine care and management.
Gait, estimated net cost of transport and heat production at different speeds in three-day-event horses.
Equine veterinary journal. Supplement    July 1, 1996   Issue 22 16-23 doi: 10.1111/j.2042-3306.1996.tb05027.x
Schroter RC, Baylis E, Marlin DJ.Heart rate and gait characteristics (stride length and frequency) were studied in 6 horses subjected to a standardised incremental exercise test, involving moving at the trot and increasing speeds up to a fast gallop and subsequently during the steeplechase phase of a 3-day-event. The studies were performed in hot conditions. Appropriate scaling, based on hindleg length (hh), stride length (L), stride frequency (f) and speed (Sp) for nondimensional stride length (lambda = (L/hh), nondimensional stride frequency (phi = f(hh/g)1/2) and nondimensional velocity (û = Sp/(ghh)1/2), where g is the g...
Evaluation of an autologous tendon graft repair method for gap healing of the deep digital flexor tendon in horses.
Veterinary surgery : VS    July 1, 1996   Volume 25, Issue 4 342-350 doi: 10.1111/j.1532-950x.1996.tb01423.x
Valdés-Vázquez MA, McClure JR, Oliver JL, Ramirez S, Seahorn TL, Haynes PF.A sutured tenorrhaphy technique that incorporated an autologous tendon graft was compared mechanically and histologically with a sutured tenorrhaphy at 6, 12, and 24 weeks after repair. Tenorrhaphy was performed in the forelimb tendon of the deep digital flexor muscle and the graft was taken from the hindlimb tendon of the lateral digital extensor muscle; one forelimb site included the graft, whereas the other forelimb site was not grafted. Tenotomies were made immediately proximal to the insertion of the accessory ligament into the tendon of the deep digital flexor muscle. Grafted and nongraf...
Apparent viscosity of the synovial fluid from mid-carpal, tibiotarsal, and distal interphalangeal joints of horses.
American journal of veterinary research    June 1, 1996   Volume 57, Issue 6 879-883 
Lumsden JM, Caron JP, Steffe JF, Briggs JL, Arnoczky SP.To compare the apparent viscosity of normal synovial fluid of the mid-carpal, tibiotarsal, and interphalangeal joints of horses. Methods: Viscosity evaluation over a range of shear rates was used to characterize the apparent viscosity of synovial fluids from the 3 joints. Methods: 60 clinically normal adult horses. Methods: Viscosity data for synovial fluid samples were obtained over a shear rate range of 10 to 250/s and apparent viscosity was calculated at 50, 100, 150, 200, and 250/s. Effect of shear rate on apparent viscosity was determined, using a two-way ANOVA, with significant differenc...
Biochemical and biomechanical alterations in equine articular cartilage following an experimentally-induced synovitis.
Osteoarthritis and cartilage    June 1, 1996   Volume 4, Issue 2 127-137 doi: 10.1016/s1063-4584(05)80321-8
Palmer JL, Bertone AL, Malemud CJ, Mansour J.The effects of inflammation on the biochemical and biomechanical properties of articular cartilage at two sites (dorsal and palmar) from the radial facet of the equine third carpal bone were examined in response to a synovitis induced with Escherichia coli lipopolysaccharide (LPS). Four groups were studied. In group 1 synovitis was induced at time zero and evaluated at week 6. Group 2 was the sham-treated control for group 1. In group 3 synovitis was induced at time zero and evaluated at week 2. Group 4 was the sham-treated control for group 3. There was a significant increase (P palmar). The...
Ultrasonic properties of tendon: velocity, attenuation, and backscattering in equine digital flexor tendons.
The Journal of the Acoustical Society of America    May 1, 1996   Volume 99, Issue 5 3225-3232 doi: 10.1121/1.414866
Miles CA.Ultrasound velocity, attenuation, and backscattering were measured in vitro in samples of equine digital flexor tendon sandwiched between plane, parallel rexolite buffer rods. The buffer rods were coupled to transmitting and receiving transducers (nominally 10 MHz) mounted in-line and facing one another on the jaws of a digital caliper. Six superficial digital flexor (SDF) tendons and six deep digital flexor (DDF) tendons were measured in three orthogonal directions: along the long axis of the tendon (D), and across the tendon in the dorsal-volar (C), and lateral (L) directions. Substantial an...
Three-dimensional kinematic technique for evaluation of horse locomotion in outdoor conditions.
Medical & biological engineering & computing    May 1, 1996   Volume 34, Issue 3 249-252 doi: 10.1007/BF02520082
Degueurce C, Dietrich G, Pourcelot P, Denoix JM, Geiger D.No abstract available
Strain-rate-dependent mechanical properties of the equine hoof wall.
The Journal of experimental biology    May 1, 1996   Volume 199, Issue Pt 5 1133-1146 doi: 10.1242/jeb.199.5.1133
Kasapi MA, Gosline JM.The mechanical properties of fully hydrated equine hoof wall were examined at various loading rates in compact tension (CT) fracture, tensile and three-point bending dynamic tests to determine possible effects of hoof wall viscoelasticity on fracture toughness and tensile parameters. Four cross-head rates were used in CT tests: 1.7 x 10(-5), 1.7 x 10 (-3), 1.7 x 10(-2) and 2.5ms-1; four strain rates were used in tensile tests: 1.6 x 10(-3), 3.2 x 10(-2), 0.33 and 70s(-1). Speeds for the highest test rates were achieved using a large, custom-built impact pendulum. Bending test frequencies range...
Tendon strain in the forelimbs as a function of gait and ground characteristics and in vitro limb loading in ponies.
Equine veterinary journal    March 1, 1996   Volume 28, Issue 2 133-138 doi: 10.1111/j.2042-3306.1996.tb01605.x
Riemersma DJ, van den Bogert AJ, Jansen MO, Schamhardt HC.Strains in the tendons of the m. flexor digitalis superficialis (superficial digital flexor, SDFT) and m. flexor digitalis profundus (deep digital flexor, DDFT) tendons, the accessory ligament of the deep digital flexor muscle (inferior check ligament, ICL) and the m. interosseus medius (suspensory ligament, SL) of 5 ponies were recorded at the walk and trot using mercury-in-silastic strain gauges (MISS), on a hard surface (brick pavement) and on sand. The horses were shod with normal, flat shoes. On pavement, strain in the SDFT, DDFT and SL increased significantly from the walk (2.19%, 1.15% ...
Influence of shoeing on ground reaction forces and tendon strains in the forelimbs of ponies.
Equine veterinary journal    March 1, 1996   Volume 28, Issue 2 126-132 doi: 10.1111/j.2042-3306.1996.tb01604.x
Riemersma DJ, van den Bogert AJ, Jansen MO, Schamhardt HC.Strains in the superficial digital flexor tendon (SDFT), deep digital flexor tendon (DDFT), accessory ligament of the deep digital flexor muscle (inferior check ligament [ICL]) and the interosseus medius muscle (suspensory ligament [SL]) in the right forelimb of 5 ponies were measured using mercury-in-silastic strain gauges a few hours after implantation. Tendon strains were recorded at the walk with normal flat shoes, egg-bar shoes, a 7 degrees increased hoof angle accomplished by application of a heel-wedge and a 7 degrees decreased hoof angle using a toe-wedge, consecutively. Ground reactio...
The effects of irradiation dose on the stiffness of cartilage grafts.
Annals of plastic surgery    March 1, 1996   Volume 36, Issue 3 297-303 doi: 10.1097/00000637-199603000-00012
Donald PJ, Deckard-Janatpour K, Sharkey N, Lagunas-Solar M.Various centers report irradiated cartilage graft absorption rates that differ quite widely. We postulated that a major factor governing this phenomenon might be irradiation dose. Irradiation produces collagen cross-binding and increased resistance to absorption of such material when implanted. Since cross-binding produces stiffening of collagen, cartilage grafts were exposed to increasing doses of irradiation and their elastic modulus was measured. The postulate was that increasing radiation doses will produce grafts of increasing stiffness. Sternal cartilage, harvested from horses, was cut i...
Effects of subject velocity on ground reaction force measurements and stance times in clinically normal horses at the walk and trot.
American journal of veterinary research    January 1, 1996   Volume 57, Issue 1 7-11 
McLaughlin RM, Gaughan EM, Roush JK, Skaggs CL.The objective of the study reported here was to evaluate the effects of changing velocity on stance time and ground reaction force (GRF) measurements in horses at the walk and trot. Methods: Force plate gait analysis was used to evaluate clinically normal horses at variable velocities. Ground reaction force measurements and stance times were recorded and compared. Methods: 12 adult horses. Methods: Data were obtained from 192 valid trials at the walk and 162 valid trials at the trot. Vertical, braking, and propulsive peak forces and impulses were measured. Pearson's correlation coefficients we...
Load redistribution after desmotomy of the accessory ligament of the deep digital flexor tendon in adult horses.
The veterinary quarterly    January 1, 1996   Volume 18 Suppl 2 S70-S74 
Buchner HH, Savelberg HH, Becker CK.An analysis of joint moments was used to study the biomechanical implications, load redistribution and kinematic pattern following desmotomy of the accessory ligament of the deep digital flexor tendon (AL) in adult horses. Recordings of 6 sound horses were made before and 10 days after desmotomy of the AL of the right forelimb at the walk and the trot. Kinematic recordings of the right forelimb and the left distal forelimb were made using the CODA-3 system. Kinetic recordings of the ground reaction forces in both forelimbs were made using a Kistler force plate simultaneously with the kinematic...
Biomechanical effects of rocker-toed shoes in sound horses.
The veterinary quarterly    January 1, 1996   Volume 18 Suppl 2 S75-S78 
Willemen MA, Savelberg HH, Jacobs MW, Barneveld A.In many Western European countries rocker-toed shoes are applied routinely in sound horses. This is in contrast to most Anglo-Saxon countries where rocker-toed shoes are used almost exclusively for corrective or orthopaedic shoeing. The purposes of rocker-toed shoes are to hasten or facilitate breakover, or to encourage breakover to occur at the centre of the toe. This study compares the biomechanical effects of rocker-toed shoes with standard flat shoes in twelve sound Dutch warmblood horses, using a modified CODA-3 gait analysis system and a force plate. The variables analysed were speed of ...
Evolution during growth of the mechanical properties of the cortical bone in equine cannon-bones.
Medical engineering & physics    January 1, 1996   Volume 18, Issue 1 79-87 doi: 10.1016/1350-4533(95)00022-4
Bigot G, Bouzidi A, Rumelhart C, Martin-Rosset W.Two specimens (70.0 x 4.5 x 1.8 mm) (proximal and distal) of cortical bone were taken from each of the cranial, caudal, lateral and medial quadrants at mid-diaphysis of the third metacarpus and metatarsus of French saddle horses (12 males and seven females) aged from 1 day to 4 years. The mechanical properties (bending strength, Young's modulus, yield stress and ultimate specific deflection) were determined by a 4-point bending test, loading at a rate of 166 x 10(-6) ms-1. During growth, the mechanical properties of the cortical bone were not significantly different (p > 0.05) between metacarp...
Factors affecting the ultrasonic properties of equine digital flexor tendons.
Ultrasound in medicine & biology    January 1, 1996   Volume 22, Issue 7 907-915 doi: 10.1016/0301-5629(96)00085-3
Miles CA, Fursey GA, Birch HL, Young RD.The velocity, attenuation and apparent backscattering coefficient of 6-11-MHz ultrasound were measured in three orthogonal directions in equine deep digital flexor (DDF) and superficial digital flexor (SDF) tendons at 0 degree C. Ultrasonic measurements were examined for correlation with tendon water, collagen, DNA and glycosaminoglycans contents, determined by chemical analyses and with structure observed by scanning electron microscopy. The SDF tendon contained more water, more DNA (i.e., more cells), less collagen and less glycosaminoglycans and exhibited lower velocities and attenuations t...
Effects of tendon grip technique (frozen versus unfrozen) on in vitro surface strain measurements of the equine deep digital flexor tendon.
American journal of veterinary research    January 1, 1996   Volume 57, Issue 1 111-115 
Matthews GL, Keegan KG, Graham HL.To determine effects of tendon grip technique on in vitro surface strain measurements of equine deep digital flexor tendon (DDFT) when loaded in tension. Methods: 12 hind limb DDFT from 8 adult horses (mean age, 9.8 years [range, 4.5 to 17 years]; mean body weight, 472 kg [range, 450 to 509 kg]), with no clinical evidence of hind limb lameness. Methods: After calibration, liquid mercury strain gauges were sutured to plantar surfaces of the tendons at distal (position 1), middle (position 2), and proximal (position 3) metatarsal regions. Each tendon was affixed to a materials testing machine (d...
Are kinematics of the walk related to the locomotion of a warmblood horse at the trot?
The veterinary quarterly    January 1, 1996   Volume 18 Suppl 2 S79-S84 
Back W, Schamhardt HC, Barneveld A.In purchase examinations or at studbook selection sales the locomotor apparatus of horses is judged both at walk and trot. To evaluate whether kinematics of the walk are related to the locomotion at the trot, fore and hind limb movements of a group of 24 26-month-old warmbloods were recorded at walk and trot on a treadmill (1.6 and 4 m/s) using a modified CODA-3 gait analysis system. The intralimb coordination patterns at walk and trot were compared, and temporal and spatial variables of these gaits were related. Stride and stance durations (s) were shorter at the trot, while the stance distan...
The effect of diagnostic regional nerve blocks in the fore limb on the locomotion of clinically sound horses.
The veterinary quarterly    January 1, 1996   Volume 18 Suppl 2 S106-S109 
Keg PR, Schamhardt HC, van Weeren PR, Barneveld A.The practice of applying diagnostic nerve blocks relies on the assumption that the blocks in themselves do not alter the horse's gait. This assumption has recently been challenged. In the present paper a series of sequential nerve blocks (low palmar digital block, abaxial sesamoid block, high palmar block) was applied to clinically sound horses. Before and after each block the gait was clinically scored and Ground Reaction Forces (GRF) were measured. Clinical scoring did not change after any of the nerve blocks. None of the GRF variables changed significantly except for a slight alteration of ...
Collagen fibril diameter distributions in ligaments and tendons of the carpal region of the horse.
Connective tissue research    January 1, 1996   Volume 34, Issue 1 11-21 doi: 10.3109/03008209609028889
Davankar SP, Deane NJ, Davies AS, Firth EC, Hodge H, Parry DA.Since horses bred for the racing industry are subject to rigorous training procedures there is a real need to understand how the stresses experienced by their tendons and ligaments in vivo relate to the major load-bearing elements-the collagen fibrils. Consequently, an age-related study has been made of the collagen fibril diameter distributions of nine ligaments in and around the equine carpus. This is the first stage of a larger study aimed at understanding the ultrastructural changes that occur as a result of exercise. Most of the ligaments showed a bimodal diameter distribution at maturity...
An in vitro biomechanical study of a multiplanar circular external fixator applied to equine third metacarpal bones.
Veterinary surgery : VS    January 1, 1996   Volume 25, Issue 1 1-5 doi: 10.1111/j.1532-950x.1996.tb01370.x
Cervantes C, Madison JB, Miller GJ, Casar RS.The biomechanical characteristics of a 4-ring circular multiplanar fixator applied to equine third metacarpal bones with a 5 mm mid-diaphyseal osteotomy gap were studied. Smooth Steinmann pins, either 1/8 inch, 3/16 inch, or 1/4 inch, were driven through pilot holes in the bone in a crossed configuration and full pin fashion and fastened to the fixator rings using cannulated fixation bolts. The third metacarpal bone fixator constructs were tested in three different modes (cranial-caudal four-point bending, axial compression, and torsion). Loads of 2,000 N were applied in bending and axial comp...
Head and trunk movement adaptations in horses with experimentally induced fore- or hindlimb lameness.
Equine veterinary journal    January 1, 1996   Volume 28, Issue 1 71-76 doi: 10.1111/j.2042-3306.1996.tb01592.x
Buchner HH, Savelberg HH, Schamhardt HC, Barneveld A.The kinematic patterns of head and trunk were studied in horses during induced supporting limb lameness to understand the mechanisms horses use to compensate for lameness and to evaluate different symmetry indices for their significance as lameness indicators. Using the locomotion analysis system CODA-3 the kinematics of 11 clinically nonlame Dutch Warmblood horses were recorded while walking (1.6 m/s) and trotting (3.5 m/s) on a treadmill. A transient lameness model, evoking pressure induced pain on the hoof sole, was used to induce 3 degrees of fore- and hindlimb lameness. Peak vertical disp...
Limb movement adaptations in horses with experimentally induced fore- or hindlimb lameness.
Equine veterinary journal    January 1, 1996   Volume 28, Issue 1 63-70 doi: 10.1111/j.2042-3306.1996.tb01591.x
Buchner HH, Savelberg HH, Schamhardt HC, Barneveld A.The kinematic patterns of all limbs of 11 clinically nonlame Dutch Warmblood horses were studied during induced supporting limb lameness to gain insight into the compensation mechanisms horses use to manage lameness and to test kinematic limb variables for their significance as lameness indicators. Using the locomotion analysis system CODA-3, the kinematics of the horses were recorded while walking (1.6 m/s) and trotting (3.5 m/s) on a treadmill. A transient lameness model, evoking pressure on the hoof sole, was used to induce 3 degrees of fore- and hindlimb lameness. Joint angle patterns and ...
The effect of the high palmar nerve block and the ulnar nerve block on lameness provoked by a collagenase-induced tendonitis of the lateral branch of the suspensory ligament.
The veterinary quarterly    January 1, 1996   Volume 18 Suppl 2 S103-S105 
Keg PR, Schamhardt HC, van Weeren PR, Barneveld A.Controversy exists with respect to the innervation of the suspensory ligament (SL) in the fore limb of the horse. It is uncertain whether this structure is exclusively innervated by branches of the ulnar nerve or also to some extent by median nerve branches. Ground Reaction Forces (GRF) were determined in horses before and after the induction of a tendonitis in the lateral branch of the SL by the injection of collagenase, and before and after a high palmar and an ulnar block respectively. The high palmar block succeeded in bringing all GRF variables back to their original values which the ulna...
Thermoregulatory responses during competitive exercise in the performance horse.
Equine veterinary journal. Supplement    November 1, 1995   Issue 20 1-164 
No abstract available
Biomechanical properties of third carpal articular cartilage in exercised and nonexercised horses.
Journal of orthopaedic research : official publication of the Orthopaedic Research Society    November 1, 1995   Volume 13, Issue 6 854-860 doi: 10.1002/jor.1100130608
Palmer JL, Bertone AL, Mansour J, Carter BG, Malemud CJ.The relevance of site and exercise on the biomechanical properties of the articular cartilage from the equine third carpal bone were assessed by creep indentation testing. Six horses were exercised for 30 minutes three times weekly. Another six horses were housed in box stalls and were not exercised. At the conclusion of the study, one third carpal bone from each horse was harvested and the KLM biphasic material properties of cartilage were determined at 12 sites. There was a significant (p < 0.01) effect of site but not exercise on the cartilage aggregate modulus, which was significantly l...
Energy comparison between trot, bound, and gallop using a simple model.
Journal of biomechanical engineering    November 1, 1995   Volume 117, Issue 4 466-473 doi: 10.1115/1.2794209
Nanua P, Waldron KJ.In this paper, the dynamics of quadruped trot, gallop, and bound will be examined using a simple model for the quadruped. The body of the quadruped is modeled as a uniform bar and the legs are modeled by massless springs. It will be shown that symmetry can be used to study the locomotion of this system. Using symmetry, a technique will be developed to obtain periodic solutions for each of the gaits of the quadruped model. These periodic solutions will be computed at various speeds. The energy levels will be compared for each of the gaits. The exchange of energy between its different forms will...
Fatigue behavior of the equine third metacarpus: mechanical property analysis.
Journal of orthopaedic research : official publication of the Orthopaedic Research Society    November 1, 1995   Volume 13, Issue 6 861-868 doi: 10.1002/jor.1100130609
Gibson VA, Stover SM, Martin RB, Gibeling JC, Willits NH, Gustafson MB, Griffin LV.This is the first in a series of experiments to study the fatigue properties of equine cannon (third metacarpal) bone specimens from Thoroughbred racehorses. Monotonic and fatigue tests to failure were performed in four-point bending on diaphyseal specimens in a 37 degrees C saline bath to answer three initial questions. (a) Will a linear variable differential transducer yield the same elastic modulus as strain gauges? (b) Will fatigue results depend on whether the periosteal or endosteal side of the beam is in tension? (c) Are there regional variations in the monotonic and fatigue properties ...
Kinematic differences between the distal portions of the forelimbs and hind limbs of horses at the trot.
American journal of veterinary research    November 1, 1995   Volume 56, Issue 11 1522-1528 
Back W, Schamhardt HC, Hartman W, Barneveld A.In literature, it has been hypothesized that the concussion at impact in the equine forelimb is larger than that in the hind limb, and therefore, eventually more clinical lameness may develop in the distal portion of the forelimbs. As the functional anatomy of the distal forelimb and hind limb segments is similar, a study was undertaken to compare the kinematics of hoof and fetlock in the forelimbs and hind limbs. For this purpose, the trot of 24 clinically normal (sound) horses on a treadmill (4 m/s) was recorded, using modern gait analysis equipment. It appeared that vertical hoof velocity a...
Intra-articular pressure, elastance, and range of motion in flexion of the equine metacarpophalangeal joint.
American journal of veterinary research    October 1, 1995   Volume 56, Issue 10 1362-1371 
Strand E, Martin GS, Crawford MP, Kamerling SG, Burba DJ, Kearney MT.A study was done to determine whether intra-articular pressure is increased in equine metacarpophalangeal joints with increasing degrees of synovial distention, and to correlate elastance of the soft tissue forming the dorsal pouch of the metacarpophalangeal joint to maximal range of motion in flexion. Sixty seven metacarpophalangeal joints in 36 horses were categorized by palpation and visual inspection of the palmar pouch into 1 of 4 increasing grades of distention. Intra-articular pressures were then measured, using 2 pressure transducers attached to 22 gauge needles, from the dorsal and pa...
Effect of maturation and aging on material and ultrasonographic properties of equine superficial digital flexor tendon.
American journal of veterinary research    October 1, 1995   Volume 56, Issue 10 1345-1350 
Gillis C, Sharkey N, Stover SM, Pool RR, Meagher DM, Willits N.Results of studies in human beings and other species have indicated that aging significantly influences the strength, modulus of elasticity, and energy storage ability of tendon. We wanted to determine the effects of aging on the material and ultrasonographic properties of equine superficial digital flexor (SDF) tendon. Ultrasonographic measurements of left forelimb SDF tendon cross-sectional area and mean echogenicity were made in 23 standing horses ranging in age from 2 to 23 years. All horses had not been in work for a minimum of 6 months prior to the study. After euthanasia, left forelimb ...
1 69 70 71 72 73 85