Analyze Diet

Topic:Blood Flow

Blood flow in horses refers to the movement of blood through the cardiovascular system, which includes the heart, arteries, veins, and capillaries. This process is essential for delivering oxygen and nutrients to tissues and organs, as well as for removing waste products from the body. Blood flow dynamics in horses are influenced by various factors, including heart rate, blood volume, and vascular resistance. The study of equine blood flow encompasses areas such as circulatory physiology, vascular health, and the impact of exercise on cardiovascular function. This page compiles peer-reviewed research studies and scholarly articles that explore the mechanisms, regulation, and implications of blood flow in equine health and performance.
Exercise alters fractal dimension and spatial correlation of pulmonary blood flow in the horse.
Journal of applied physiology (Bethesda, Md. : 1985)    June 14, 2000   Volume 88, Issue 6 2269-2278 doi: 10.1152/jappl.2000.88.6.2269
Sinclair SE, McKinney S, Glenny RW, Bernard SL, Hlastala MP.We determined the changes in fractal dimensions and spatial correlations of regional pulmonary blood flow with increasing exercise in race horses (n = 4) by using 15-microm fluorescent microspheres. Fluorescence was measured to quantitate regional blood to 1.3-cm(3) samples (n = 1,621-2,503). Perfusion distributions were characterized with fractal dimensions (a measure of spatial variability) and spatial correlations. On average, the fractal dimension decreased with exercise (trot 1.216 to gallop 1.173; P < 0. 05) despite a variable fractal dimension at rest. Spatial correlation of flow to ...
Repeatability of Doppler ultrasound measurements of hindlimb blood flow in halothane anaesthetised horses.
Equine veterinary journal    June 3, 2000   Volume 32, Issue 3 239-246 doi: 10.2746/042516400776563662
Raisis AL, Young LE, Meire H, Walsh K, Taylor PM, Lekeux P.The purpose of this study was to determine the repeatability of femoral blood flow recorded using Doppler ultrasound in anaesthetised horses. Doppler ultrasound of the femoral artery and vein was performed in 6 horses anaesthetised with halothane and positioned in left lateral recumbency. Velocity spectra, recorded using low pulse repetition frequency, were used to calculate time-averaged mean velocity (TAV), velocity of component a (TaVa), velocity of component b (TaVb), volumetric flow, early diastolic deceleration slope (EDDS) and pulsatility index (PI). Within-patient variability was deter...
Variability of Doppler ultrasound measurements of hindlimb blood flow in conscious horses.
Equine veterinary journal    April 1, 2000   Volume 32, Issue 2 125-132 doi: 10.2746/042516400777591561
Raisis AL, Young LE, Meire HB, Taylor PM, Walsh K, Lekeux P.Ultrasonography of the left and right femoral artery and vein was performed in 5 conscious horses. Velocity waveforms, recorded using low pulse repetition frequency, were used to calculate time-averaged mean velocity (TAV), velocity of component a (TaVa), velocity of component b (TaVb) and volumetric flow. Waveform analysis included calculation of early diastolic deceleration slope (EDDS) and pulsatility index (PI) and subjective description of the waveform. Measurements were recorded at monthly intervals for 6 months. The repeated measurements were used to determine the within-horse variation...
Doppler ultrasonography and single-fiber laser Doppler flowmetry for measurement of hind limb blood flow in anesthetized horses.
American journal of veterinary research    March 14, 2000   Volume 61, Issue 3 286-290 doi: 10.2460/ajvr.2000.61.286
Raisis AL, Young LE, Taylor PM, Walsh KP, Lekeux P.To use Doppler ultrasonography and single-fiber laser Doppler flowmetry (LDF) to evaluate blood flow in the dependent and nondependent hind limbs of anesthetized horses and to evaluate changes in femoral arterial blood flow and microvascular skeletal muscle perfusion in response to administration of phenylephrine hydrochloride or dobutamine hydrochloride. Methods: 6 healthy adult horses. Methods: Horses were anesthetized and positioned in left lateral recumbency. Doppler ultrasonography was used to measure velocity and volumetric flow in the femoral vessels. Single-fiber LDF was used to measur...
Doppler ultrasonographic features of thoracic limb arteries in clinically normal horses.
American journal of veterinary research    February 24, 2000   Volume 61, Issue 2 183-190 doi: 10.2460/ajvr.2000.61.183
Cochard T, Toal RL, Saxton AM.To determine blood flow velocities and indices from spectral waveforms obtained by use of Doppler ultrasonography of thoracic limb arteries of horses and to assess interobserver and patient variability associated with the technique. Methods: 9 clinically normal adult horses. Methods: Left thoracic limb arteries of 8 nonsedated horses were examined at 5 sites by use of pulsed-wave Doppler ultrasonography to determine a range of values for peak systolic, end diastolic, and mean velocities and resistive and pulsatility indices. Interobserver and patient variabilities were determined by 2 operator...
Effect of furosemide on pulmonary blood flow distribution in resting and exercising horses.
Journal of applied physiology (Bethesda, Md. : 1985)    June 16, 1999   Volume 86, Issue 6 2034-2043 doi: 10.1152/jappl.1999.86.6.2034
Erickson HH, Bernard SL, Glenny RW, Fedde MR, Polissar NL, Basaraba RJ, Walther SM, Gaughan EM, McMurphy R, Hlastala MP.We determined the spatial distribution of pulmonary blood flow (PBF) with 15-micron fluorescent-labeled microspheres during rest and exercise in five Thoroughbred horses before and 4 h after furosemide administration (0.5 mg/kg iv). The primary finding of this study was that PBF redistribution occurred from rest to exercise, both with and without furosemide. However, there was less blood flow to the dorsal portion of the lung during exercise postfurosemide compared with prefurosemide. Furosemide did alter the resting perfusion distribution by increasing the flow to the ventral regions of the l...
Effects on the intramuscular blood flow and cardiopulmonary function of anaesthetised ponies of changing from halothane to isoflurane maintenance and vice versa.
The Veterinary record    January 9, 1999   Volume 143, Issue 23 629-633 
Lee YH, Clarke KW, Alibhai HI.The effects on intramuscular blood flow and cardiopulmonary parameters of changing from anaesthesia with halothane to isoflurane and vice versa were investigated in six ponies (small horses). Anaesthesia was induced with xylazine, ketamine and diazepam, maintained for one hour with halothane at an end tidal concentration of 1 per cent and then with isoflurane at 1.5 per cent for a further hour (halo/iso). On another occasion the order in which the volatile agents were administered was reversed (iso/halo). After one hour of anaesthesia the mean (sd) arterial blood pressure (MAP) and cardiac out...
Hepatic blood flow in horses during the recuperative period from maximal exercise.
American journal of veterinary research    November 26, 1998   Volume 59, Issue 11 1476-1480 
Dyke TM, Hubbell JA, Sams RA, Hinchcliff KW.To determine effects of walking or standing on hepatic blood flow of horses after brief, intense exercise. Methods: 6 adult Thoroughbreds (4 mares, 2 geldings). Methods: Horses were preconditioned on a treadmill to establish uniform level of fitness. Once fit, treadmill speed causing each horse to exercise at 120% of maximal oxygen consumption was determined and used in simulated races at 14-day intervals. In a three-way crossover study, horses were exercised at a speed inducing 120% of maximal oxygen consumption until fatigued or for a maximum of 2 minutes. Three interventions were studied: r...
Local hemodynamics, permeability, and oxygen metabolism during acute inflammation of innervated or denervated isolated equine joints.
American journal of veterinary research    October 22, 1998   Volume 59, Issue 10 1307-1316 
Hardy J, Bertone AL, Muir WW.To determine oxygen metabolism, permeability, and blood flow in isolated joints in response to interleukin 1beta (IL-1beta) and contribution of innervation. Methods: One metacarpophalangeal (MCP) joint of 24 adult horses. Methods: The MCP joint was isolated for 6 hours in a pump-perfused, auto-oxygenated, innervated or denervated preparation. Isolated joints were assigned to the following 4 groups: control, control-denervated, inflamed, and inflamed-denervated, and inflammation was induced by intra-articular injection of IL-1beta. Circuit arterial and venous pressures, flows, and blood gas ten...
Absence of detectable pharmacological effects after oral administration of isoxsuprine.
Equine veterinary journal    August 15, 1998   Volume 30, Issue 4 294-299 doi: 10.1111/j.2042-3306.1998.tb04100.x
Harkins JD, Mundy GD, Stanley S, Woods WE, Sams RA, Richardson DR, Grambow SC, Tobin T.Isoxsuprine is reported to be a peripheral vasodilator used in human and veterinary medicine to treat ischaemic vascular disease. In horses, it is generally administered orally to treat navicular disease and other lower limb problems. To define the scope and duration of its pharmacological responses after oral administration, 6 horses were dosed with isoxsuprine HCl (1.2 mg/kg bwt) q. 12 h for 8 days and then tested to assess the duration and extent of pharmacological actions. There was no significant difference between isoxsuprine and control treatment values for heart rate, spontaneous activ...
Regional differences in endothelial function in horse lungs: possible role in blood flow distribution?
Journal of applied physiology (Bethesda, Md. : 1985)    August 4, 1998   Volume 85, Issue 2 537-542 doi: 10.1152/jappl.1998.85.2.537
Pelletier N, Robinson NE, Kaiser L, Derksen FJ.We investigated regional differences of in vitro responses of pulmonary arteries (6-mm OD) from the dorsocaudal (top) and cranioventral (bottom) lung regions to endothelium-dependent vasodilators (methacholine, bradykinin, and calcium ionophore A-23187). Methacholine relaxed endothelium-intact top vessels; however, in bottom vessels, a small relaxation preceded a profound contraction. In top vessels, removal of endothelial cells converted relaxation to contraction, and in bottom vessels it abolished relaxation and enhanced contraction. Bradykinin and A-23187 were more potent and caused greater...
Regional distribution of blood flow in the brain of horses at rest and during exercise.
American journal of veterinary research    July 11, 1998   Volume 59, Issue 7 893-897 
Manohar M, Goetz TE.To examine regional distribution of blood flow in the brain of horses at rest and during exercise. Methods: 9 clinically normal horses. Methods: Regional brain blood flow was measured using radionuclide-labeled 15-microns-diameter microspheres injected into the left ventricle, while reference blood samples were obtained from the aorta. Results: At rest, cerebral cortex and caudate nuclei received significantly higher blood flow, compared with cerebral white matter. A similar perfusion heterogeneity existed in the cerebellum. In the brain stem, a gradual tapering of blood flow from thalamus-hyp...
Ultrasonography of the femoral artery in six normal horses and three horses with thrombosis. Warmerdam EP.Ultrasonography of the femoral artery in the horse, including color, power and spectral Doppler, provides morphologic and dynamic information. This paper describes the use of the techniques in six clinically normal horses and three with femoral artery thrombosis. Useful landmarks for orientation are the saphenous artery and the medial saphenous vein. The lateral circumflex femoral artery can not be visualized. Recognition of the genus descendens artery is complicated due to the presence of multiple distal caudal femoral arteries. The femoral artery feeds a high resistance bed. In normal horses...
Evaluation of digital and laminar blood flow in horses given a low dose of endotoxin.
American journal of veterinary research    March 11, 1998   Volume 59, Issue 2 192-196 
Ingle-Fehr JE, Baxter GM.To measure blood flow in the palmar digital artery and laminae corium, using ultrasonic and laser Doppler flowmetry, respectively. Methods: 6 healthy horses. Methods: Digital blood flow and laminar perfusion, respectively, were measured by placing a flow probe around the palmar digital artery and a laser Doppler flow probe in a hole in the dorsal aspect of the hoof wall. All horses were given saline (0.9% NaCl) solution (1 L, IV, during a 30-minute period). Seven days later, each horse was given endotoxin (0.1 microgram/kg of body weight, IV, in 1 L of saline solution, during a 30-minute perio...
Diseases and surgery of the cecum.
The Veterinary clinics of North America. Equine practice    August 1, 1997   Volume 13, Issue 2 303-315 doi: 10.1016/s0749-0739(17)30241-9
Dabareiner RM, White NA.The cecum is an important site of water and electrolyte absorption, as well as microbial digestion of soluble and insoluble carbohydrates. These functions of the cecum and ascending colon require that ingesta be mixed constantly and retained long enough to complete the digestion of cellulose. Parasites, changes in regional blood flow, diet, and various pharmacologic agents are associated with alterations in normal cecal motility patterns.
Use of Doppler ultrasonography to evaluate renal arterial blood flow in horses.
American journal of veterinary research    July 1, 1997   Volume 58, Issue 7 697-701 
Hoffmann KL, Wood AK, Kirby AC.To obtain Doppler ultrasonographic images of renal arteries in horses and to establish reference range values for systolic and diastolic renal arterial blood flow and resistive indices. Also to determine whether Doppler ultrasonography could be used in horses to detect changes in renal blood flow after IV administration of furosemide. Methods: 11 clinically normal adult horses. Methods: Pulsed-wave Doppler examinations were performed on arcuate arteries of 5 sedated horses. Continuous-wave Doppler examinations were performed on pyelorenal arteries in 7 nonsedated horses and were repeated in 6 ...
Perinatal carbohydrate metabolism and the blood flow of the fetal liver.
Equine veterinary journal. Supplement    June 1, 1997   Issue 24 26-31 doi: 10.1111/j.2042-3306.1997.tb05075.x
Barnes RJ.No abstract available
Pulsed wave-Doppler ultrasonographic evaluation of the common carotid artery in the resting horse: physiologic data. Cipone M, Pietra M, Gandini G, Boari A, Guglielmini C, Venturoli M.A pulsed wave-Doppler ultrasonographic evaluation of common carotid arterial blood flow was carried out on 63 healthy Italian Saddlebred horses. Vessel diameter and tracing morphology were evaluated and blood flow parameters (systolic, diastolic and mean velocity, acceleration and deceleration of the systolic wave, carotid pulse volume) were calculated and correlated with class variables (sex, age and body weight). On the basis of the presence of an incisure in the ascending branch of the systolic curve, subjects were divided in two groups: one with a bifid systolic curve and the other with a ...
Measurement of cardiac output in standing horses by Doppler echocardiography and thermodilution.
Equine veterinary journal    January 1, 1997   Volume 29, Issue 1 18-25 doi: 10.1111/j.2042-3306.1997.tb01631.x
Blissitt KJ, Young LE, Jones RS, Darke PG, Utting J.Measurement of cardiac output by Doppler echocardiography were compared to simultaneous measurements by thermodilution in 9 conscious horses. In the Doppler technique, mean blood flow velocities for estimation of cardiac output were recorded from the aorta and pulmonary artery. The flow area of each vessel was calculated from the vessel diameter, measured from a 2-dimensional ultrasound image. Differences in the site and method of measuring the vessel diameter altered the estimation of cardiac output by the Doppler method. Cardiac output was modified by the i.v. infusion of 4 micrograms/kg bwt...
Pulmonary blood flow distribution in exercising and in resting horses.
Journal of applied physiology (Bethesda, Md. : 1985)    September 1, 1996   Volume 81, Issue 3 1049-1050 doi: 10.1152/jappl.1996.81.3.1049
Hughes JM.No abstract available
Pulmonary blood flow distribution in standing horses is not dominated by gravity.
Journal of applied physiology (Bethesda, Md. : 1985)    September 1, 1996   Volume 81, Issue 3 1051-1061 doi: 10.1152/jappl.1996.81.3.1051
Hlastala MP, Bernard SL, Erickson HH, Fedde MR, Gaughan EM, McMurphy R, Emery MJ, Polissar N, Glenny RW.Recent studies using microspheres in dogs, pigs and goats have demonstrated considerable heterogeneity of pulmonary perfusion within isogravitational planes. These studies demonstrate a minimal role of gravity in determining pulmonary blood flow distribution. To test whether a gravitational gradient would be more apparent in an animal with large vertical lung height, we measured perfusion heterogeneity in horses (vertical lung height = approximately 55 cm). Four unanesthetized Thoroughbred geldings (422-500 kg) were studied awake in the standing position with fluorescent microspheres injected ...
Minimal redistribution of pulmonary blood flow with exercise in racehorses.
Journal of applied physiology (Bethesda, Md. : 1985)    September 1, 1996   Volume 81, Issue 3 1062-1070 doi: 10.1152/jappl.1996.81.3.1062
Bernard SL, Glenny RW, Erickson HH, Fedde MR, Polissar N, Basaraba RJ, Hlastala MP.We determined the spatial distribution of pulmonary blood flow at rest and during increasing levels of exercise (34, 59, and 90% of maximal oxygen consumption) in Thoroughbred racehorses (n = 4) using 15-microns fluorescent microspheres. After the horses were killed, the lungs were flushed free of blood, removed, air-dried at total lung capacity, and sliced into isogravitational planes, which were sampled in a systematic fashion for three-dimensional reconstruction. The fluorescence was measured for quantification of blood flow. Mean pulmonary blood flow heterogeneity (expressed as a coefficie...
Redistribution of cardiac output in response to heat exposure in the pony.
Equine veterinary journal. Supplement    July 1, 1996   Issue 22 42-46 doi: 10.1111/j.2042-3306.1996.tb05030.x
McConaghy FF, Hodgson DR, Rose RJ, Hales JR.Radioactive microspheres were used to measure cardiac output and blood flow to most major tissues in 4 ponies at rest in thermoneutral (16 degrees C/60% RH) and mildly hot (41 degrees C/34% RH) environments. In response to heat stress there were increases in cardiac output (2-fold), respiratory frequency (5-fold), blood flow to the skin of the body (3-fold), and limbs (50%), respiratory muscles (2-fold) and the upper respiratory tract (3-fold). Ponies were able to maintain body temperature in the hot environment by increasing blood flow to the tissues involved in heat dissipation, while blood ...
Joint pressure influences synovial tissue blood flow as determined by colored microspheres.
Journal of applied physiology (Bethesda, Md. : 1985)    April 1, 1996   Volume 80, Issue 4 1225-1232 doi: 10.1152/jappl.1996.80.4.1225
Hardy J, Bertone AL, Muir WW.We measured regional blood flow in synovial tissue of the antebrachiocarpal, midcarpal, and metacarpophalangeal joints of six normal adult anesthetized horses by using 15-microns-diameter polystyrene colored microspheres. The midcarpal fibrous capsule and synovial membrane blood flows (SMBF) were compared, and the effect of increased intra-articular pressure (30 and 60 mmHg) on midcarpal SMBF was investigated. Dorsal, medial palmar, and lateral palmar midcarpal SMBF measured 108 +/- 36, 61 +/- 12, and 50 +/- 11 microliters.min-1.g-1, respectively. Antebrachiocarpal, dorsal, and palmar metacarp...
The effect of xylazine on equine muscle surface capillary blood flow.
Journal of veterinary pharmacology and therapeutics    October 1, 1995   Volume 18, Issue 5 388-390 doi: 10.1111/j.1365-2885.1995.tb00611.x
Hennig GE, Court MH, King VL.No abstract available
Pulsed wave Doppler echocardiography in normal horses.
Equine veterinary journal. Supplement    September 1, 1995   Issue 19 38-46 doi: 10.1111/j.2042-3306.1995.tb04988.x
Blissitt KJ, Bonagura JD.Reference values were established for selected Doppler derived variables from a group of 40 normal Thoroughbred and Thoroughbred cross horses. Standard two-dimensional (2-D) images used for guiding the Doppler sampling site allowed accurate alignment with flow. Tricuspid inflow velocities during rapid filling (E) and atrial contraction (A) were significantly higher when recorded from a right parasternal angled view than from a right parasternal long-axis view. In 8 horses the tricuspid inflow peak A velocity was higher than the peak E velocity. The peak acceleration of blood flow was higher (P...
Exercise induced ventilation/perfusion inequality in the horse.
Equine veterinary journal    March 1, 1995   Volume 27, Issue 2 104-109 doi: 10.1111/j.2042-3306.1995.tb03044.x
Seaman J, Erickson BK, Kubo K, Hiraga A, Kai M, Yamaya Y, Wagner PD.Exercise in normal human subjects causes deterioration of matching of ventilation to blood flow in the lungs, but only in about 50% of those examined. A previous study (Wagner et al. 1989) of 5 horses showed no significant worsening of ventilation/blood flow (VA/Q) relationships during heavy exercise as determined by multiple inert gas elimination technique (MIGET). Because of the small number of horses in that study and the 50% human incidence of exercise induced VA/Q mismatch, we studied an additional 6 Thoroughbreds, comparing VA/Q relationships at the walk (1.4 m/s, 0 degrees incline) and ...
Capillary-tissue arrangement in the skeletal muscle optimized for oxygen transport in all mammals.
Microvascular research    March 1, 1995   Volume 49, Issue 2 163-179 doi: 10.1006/mvre.1995.1013
Baba K, Kawamura T, Shibata M, Sohirad M, Kamiya A.The aim of this computer simulation study is to evaluate the efficiency of capillary networks in the skeletal muscle for oxygen (O2) delivery to tissue for all mammals. This was performed by: (1) employing Krogh's cylinder model for the capillary-tissue system and the minimum volume model for the vascular system, (2) allometrically assessing the muscle blood flow and O2 consumption rate (the main input data) in the resting and exercising states as power functions of body weight from the data reported for several mammals, and (3) calculating the cost-performance of the system from the ratio (ma...
Evaluation of laser Doppler flowmetry for measuring coronary band and laminar microcirculatory blood flow in clinically normal horses.
American journal of veterinary research    April 1, 1994   Volume 55, Issue 4 445-449 
Adair HS, Goble DO, Shires GM, Sanders WL.Once daily for 3 days, laser Doppler flowmetry was used in 5 healthy, nonsedated adult horses to evaluate coronary band and laminar microcirculatory blood flow (MBF) in both forelimbs. The coronary band had significantly (P < 0.05) higher MBF than did the laminae on the days evaluated. Significant variation in MBF was not found over the 3-day measurement period in any one site. Significant (P < 0.05) variation was found in coronary band MBF among horses. This variation was not observed in laminar MBF. On occlusion of the digital arteries at the level of the fetlock, marked decrease in coronary...
Effects of acetylpromazine, xylazine, and vertical load on digital arterial blood flow in horses.
American journal of veterinary research    March 1, 1994   Volume 55, Issue 3 375-378 
Hunt RJ, Brandon CI, McCann ME.Palmar digital arterial blood flow was measured in 6 conscious, standing horses, using surgically placed perivascular ultrasonic flow probes. The effects of 2 dosages of xylazine (0.55 and 1.1 mg/kg of body weight) and of 3 dosages of acetylpromazine (0.01, 0.02, and 0.04 mg/kg), as well as the effect of vertical load, on digital blood flow were evaluated. Intravenous administration of xylazine induced a significant (P < 0.05), transient decrease in digital blood flow. Intravenous administration of acetylpromazine induced a significant (P < 0.05), prolonged increase in digital blood flow...