Topic:Echocardiography
Echocardiography is a diagnostic imaging technique used to assess the heart's structure and function in horses. It utilizes ultrasound waves to create detailed images of the heart, allowing veterinarians to evaluate cardiac anatomy, blood flow, and heart motion. Echocardiography is instrumental in diagnosing various cardiac conditions, such as valvular disorders, congenital heart defects, and myocardial diseases in equine patients. The procedure provides valuable information on heart size, wall thickness, and chamber dimensions. This page compiles peer-reviewed research studies and scholarly articles that explore the methodologies, applications, and clinical implications of echocardiography in equine cardiology.
Heart murmurs in horses: determining their significance with echocardiography. Physiological flow murmurs occur frequently in horses and may be difficult to distinguish from murmurs associated with underlying cardiac disease. The significance of heart murmurs auscultated in horses is often difficult to determine if the horse is not exhibiting any clinical signs or if the signs, such as poor performance, are nonspecific. A complete echocardiographic examination (M-mode, 2-dimensional (2-D) and Doppler) provides an objective assessment of the severity of the horse's underlying cardiac disease. Valvular regurgitation and ventricular septal defects (VSDs) occur frequently an...
Physiological valvular regurgitation in clinically normal young racehorses: prevalence and two-dimensional colour flow Doppler echocardiographic characteristics. Colour flow Doppler echocardiographic examinations were performed on 15 horses; 10 Thoroughbreds and 5 Standardbreds; 9 mares, 5 geldings and 1 stallion; mean +/- s.d. 3.4 +/- 1.1 years. Cardiac murmurs were audible in 12 horses (80%), but these had characteristics consistent with functional murmurs in all horses. A standardised two-dimensional (2-D) and M-mode echocardiographic examination was unremarkable in all horses except that aortic valve prolapse was identified in 3 horses, tricuspid valve prolapse in 2 horses and mitral valve prolapse was present in one horse. Colour flow Doppler echo...
Pseudomonas spp. associated vegetative endocarditis in two horses. This paper describes the case histories of two Thoroughbred horses, a 2-year-old colt in training and a 7-year-old broodmare, that were presented with histories of weight loss, exercise intolerance, intermittent fever, limb oedema and anaemia. Vegetative endocarditis of the mitral and tricuspid valves was diagnosed in the colt by means of echocardiography. Pseudomonas sp. endocarditis of the mitral valve was diagnosed in the mare using echocardiography and bacterial culture. The colt had secondary congestive heart failure and was euthanased on humane grounds. Pseudomonas cepacia was isolated f...
Feasibility of transoesophageal echocardiography for evaluation of left ventricular performance in anaesthetised horses. Transoesophageal Doppler echocardiography was performed in 7 Thoroughbred horses anaesthetised with halothane. The procedure was performed on 4 occasions under standard conditions. On one occasion dobutamine hydrochloride was infused at 4 micrograms/kg/min for 20 min. Recordings of aortic blood velocity, obtained using high pulsed repetition frequency Doppler echocardiography (HPRF), were used to derive maximum acceleration (dv/dtmax), maximum velocity (Vmax), left ventricular ejection time (ET), pre-ejection period (PEP), velocity time integral (VTI) and cardiac output (CO). The coefficient o...
Evaluation of ventricular septal defects in horses using two-dimensional and Doppler echocardiography. Ventricular septal defects (VSDs) were diagnosed in 27 horses; in 26 affected horses systolic murmurs were detected over both sides of the chest. Holodiastolic decrescendo murmurs were also detected in 5 horses. Standardbreds and Arabian horses were over-represented, while Thoroughbred horses were under-represented, when compared to the hospital population (P < 0.0001). Five horses had previously raced successfully, one 2-year-old was training successfully and close to racing, and 4 horses had competed successfully in other types of competition. Eleven horses had a history of exercise intolera...
Pulsed wave Doppler echocardiography in normal horses. Reference values were established for selected Doppler derived variables from a group of 40 normal Thoroughbred and Thoroughbred cross horses. Standard two-dimensional (2-D) images used for guiding the Doppler sampling site allowed accurate alignment with flow. Tricuspid inflow velocities during rapid filling (E) and atrial contraction (A) were significantly higher when recorded from a right parasternal angled view than from a right parasternal long-axis view. In 8 horses the tricuspid inflow peak A velocity was higher than the peak E velocity. The peak acceleration of blood flow was higher (P...
Ventricular tachycardia and myocardial dysfunction in a horse. Ventricular tachycardia develops less frequently than supraventricular dysrhythmias and generally is more indicative of cardiac disease. The horse in this report had clinical signs of lethargy and hypophagia and was determined to have sustained ventricular tachycardia. Echocardiography was a valuable diagnostic tool and revealed an echodense area in the left ventricle that had subnormal ventricular performance. A primary heart problem of an inflammatory nature was suspected. The horse responded favorably to treatment with lidocaine, antimicrobials, and aspirin, as well as stall rest. The horse...
Equine echocardiography–sound advice at the heart of the matter. Echocardiography is an extremely versatile tool for both the equine clinician and physiologist. There are three useful forms of echocardiography, B mode, M mode and Doppler. Together they provide complementary information on cardiac disease and haemodynamic status. B mode is used to image the cardiac chambers, valves, myocardium and pericardium. M mode allows determination of motion of cardiac structures; it is superior to B mode for timing of events and it is used to make precise measurements of the heart. Doppler echocardiography can assess intracardiac blood flow and its velocity. Echocardi...
[A comparison of cardiac stroke volume determination using the thermodilution method and PW-Doppler echocardiography for the evaluation of systolic heart function in the horse]. In 14 horses without heart disease stroke volume determination were established by pulsed wave doppler echocardiography. Thermodilution and doppler echocardiography were used simultaneously. The doppler echocardiographic volume determinations were carried out in left and right outflow tracts. Echocardiographically Velocity Time Integral, Maximum Flow Velocity, Mean Flow Velocity and Acceleration Time were ascertained. To be able to compare heart volumes of horses with different body weight stroke volume was applied to 1 kg of body weight (= heart index). Heart Index determined with thermodilut...
[Echocardiography and therapy of atrial fibrillation in horses]. Echocardiographic evaluation of 45 horses (43 warm-blooded horses, one Thoroughbred and one Standardbred) with atrial fibrillation was performed, using M-mode, B-mode and pulsed-wave Doppler echocardiography. Seventeen (38%) of these horses had a history of poor performance. An increase of left ventricular shortening fraction was found in 25 horses (56%). Atrial dilatation was seen in 37 horses (82%). Eight horses (18%) had normal atrial dimensions. In nine horses only left atrium and in six horses only right atrium was enlarged. In the other 22 horses both atria were dilated. Correlation was ...
Comparison of methods of cardiac output measurements determined by dye dilution, pulsed Doppler echocardiography and thermodilution in horses. Cardiac output (CO) measurements by the three methods of dye dilution, pulsed Doppler echocardiography and thermodilution in horses under anesthetized conditions were compared. Although CO determined by the thermodilution method was slightly higher than those obtained by the other two methods, the measurements by all methods showed almost similar results. The coefficients of correlation between the dye dilution and thermodilution methods, the dye dilution and pulsed Doppler echocardiography methods, and the thermodilution and pulsed Doppler echocardiography methods were 0.87, 0.89, and 0.88, r...
[Pulsed Doppler echocardiography measurement in healthy warmblood horses]. Twenty adult warm blooded horses (body weight 585 +/- 59 kg) were evaluated with pulsed doppler echocardiography. Locations for the transducer and the sample volume were determined to get typical blood flow tracings of the equine heart. Angle of doppler beam was between 37 degrees and 40 degrees in right heart atrioventricular flow tract and between 44 degrees and 47 degrees in left heart atrioventricular flow tract. Peak blood flow velocity (angle corrected) was 0.71 +/- 0.17 m/s in tricuspid valve and 0.92 +/- 0.22 in mitral valve. In right and left atrioventricular flow tracts in all sample...
[M-mode echocardiography in dressage horses, class S jumping horses and untrained horses]. Heart structures of 45 warmblooded horses were measured by M-mode-echocardiography. The current training level of 15 dressage horses (group I) and 15 show-jumping horses (group II) was category "S". In the third group were 15 untrained horses. Four standardized transducer positions were determined for the m-mode echobeam, calibrated according to the two-dimensional real time technique. End systolic and end diastolic diameters of left ventricle, right ventricle, aortic root, interventricular septum and left ventricular wall, as well as motion pattern of heart wall, mitral valve and aortic valve...
Idiopathic, aseptic, effusive, fibrinous, nonconstrictive pericarditis with tamponade in a standardbred filly. A Standardbred filly was admitted for evaluation of pleuritis and pneumonia. Heart rate was 80 to 120 beats/min, and the pulse was barely palpable. Thoracic and abdominal ultrasonography and echocardiography revealed substantial pericardial effusion with cardiac tamponade, fibrinous pericarditis, pleural effusion, and ascites. Initial electrocardiography revealed normal sinus rhythm with decreased amplitude of the QRS complexes consistent with pericardial effusion. Following thoracentesis, echocardiogram-guided pericardiocentesis was performed. Bacterial culture yielded no growth from any of t...
[B-mode, M-mode and Doppler sonographic findings in mitral valve insufficiency of horses]. B- and M-mode echocardiography was performed on 38 horses. 34 patients had systolic heart murmur with the point of maximal intensity over mitral valve. Additionally, 17 of these patients were examined with the pulsed wave doppler echocardiography (Vingmed 200). In 26 patients with cardiac murmur and in 4 patients without cardiac murmur a mitral valve insufficiency was diagnosed by echocardiography. In 8 horses with a systolic murmur over mitral valve M- and B-mode evaluation could not reveal a haemodynamic importance of the murmur. The diagnosis of MVI was based on a dilation of left atrium wi...
Medical evaluation of the cardiovascular system. The approach to pre-purchase evaluation of the equine cardiovascular system is discussed with emphasis on cardiac auscultation and on the terminology that should be used when reporting clinical findings. Innocent cardiac murmurs and arrhythmias are contrasted with those that should be considered as reliable signs of cardiovascular disease. Ultrasonography and electrocardiography are recommended to establish baseline values for future reference, to support opinions rendered by the examining veterinarians, or to provide for diagnosis and treatment.
Vegetative endocarditis in an Appaloosa gelding. A 5-year-old Appaloosa gelding was presented with a history of intermittent multiple joint swelling, weight loss, and anemia. Physical examination and clinical pathology revealed a grade IV/VI holodiastolic murmur, louder on the left, and a marked hyperproteinemia. Echocardiography of the heart demonstrated a large vegetative lesion on one of the aortic valve cusps. Blood cultures did not elucidate the causative organism, and the disease was refractory to empiric antibiotic therapy. The horse was euthanized after approximately 2 months of therapy.
Standardised imaging technique for guided M-mode and Doppler echocardiography in the horse. Eighteen echocardiographic images useful for diagnostic imaging, M-mode echocardiography, and Doppler echocardiography of the equine heart were standardised by relating the position of the axial beam to various intracardiac landmarks. The transducer orientation required for each image was recorded in 14 adult horses by describing the degree of sector rotation and the orientation of the axial beam relative to the thorax. Repeatable images could be obtained within narrow limits of angulation and rotation for 14 of the 18 standardised images evaluated. Twenty-seven National Hunt horses were subse...
Spontaneous echocardiographic contrast in the thoroughbred: high prevalence in racehorses and a characteristic abnormality in bleeders. Spontaneous echocardiographic contrast is the term used by ultrasonographers to describe particulate material visible in intracardiac blood by ultrasound. The purpose of the present study was to determine the prevalence of spontaneous contrast in a farm population of Thoroughbreds and in the farm's racehorses. The results showed that spontaneous echocardiographic contrast is common in Thoroughbreds, and that the prevalence of contrast is affected by age, male gender, racing and pregnancy. The amount of right-sided cardiac contrast was quantitated by videodensitometry and was increased in horse...
Measurement of cardiac dimensions with two-dimensional echocardiography in the living horse. Two-dimensional echocardiography (2DE) was performed on 22 unsedated Thoroughbred and part Thoroughbred horses weighing between 411 and 650 kg to establish normal reference values for 2DE measurements. Animals stood during examinations performed with a 3.5 MHz mechanical sector transducer using various transducer positions and tomographic planes. Right ventricular diameter (RVD), ventricular septal thickness (VSTh), aortic diameter (AoD), area of the chordal lumen of the left ventricle (CTA), left ventricular diameter (LVD) and left atrial diameter (LAD) were determined at ventricular end-dias...
Two-dimensional echocardiographically guided pericardiocentesis in a horse with traumatic pericarditis. Two-dimensional echocardiographic (2DE) examination was performed on a horse with clinical signs of pericardial effusion. Thickening of the pericardium, excess amount of pericardial fluid, elevation of the cardiac apex, and right ventricular compression, characteristic of cardiac tamponade, could be seen on 2DE recordings. Fibrinous pericarditis was suspected by observation of fibrinous strands in the pericardial fluid and epicardial fibrin deposits. Echocardiographically guided pericardiocentesis was performed, and 4 L of fluid was removed from the pericardial sac. Streptococcus zooepidemicus...
Echocardiographic detection of pulmonic valve rupture in a horse with right-sided heart failure. Pulmonic valve rupture was determined to be the cause of severe right-sided heart failure in a 20-year-old Thoroughbred gelding. A flail in the intermediate pulmonic valve cusp was detected by 2-dimensional echocardiography. Significant pulmonic and tricuspid valvular regurgitation were confirmed by Doppler echocardiography. Despite treatment, the horse's condition deteriorated, and euthanasia was performed. At necropsy, a tear in the pulmonary artery extending into the right valve cusp and a tear at the base of the intermediate valve cusp were identified at the junction of the right and inter...
Atrial septal defect and atrial fibrillation in a foal. Clinical examination of a four-and-a-half-month old foal revealed evidence of progressive heart failure associated with an atrial septal defect and atrial fibrillation. Atrial septal defects are rarely reported in foals and the foal's growth, development and demeanour were normal until a sudden onset of lethargic behaviour. The value of B-mode echocardiography in identifying the congenital lesion is indicated.
An investigation of the second heart sound in the normal horse. The second heart sound was evaluated in conscious, normal horses using intracardiac and external sound detection devices and echocardiography. The second heart sound (S2) in the normal horse is single or split by a narrow interval, not usually detected by external phonocardiographic evaluation. Splitting of S2 was classified as normal (aortic [A2] preceding pulmonic [P2] components) in 66.7 per cent and reversed (P2 preceding A2) in 33.3 per cent of the horses studied. Normal splitting appears to result from lower impedance of the pulmonary vasculature delaying the onset of P2. Reverse splitti...
Anatomical validation of two-dimensional echocardiography in the horse. This study was performed on 15 horses to validate the cardiac anatomy as imaged with two dimensional echocardiography (2DE) and to determine the accuracy of intracardiac measurements. 2DE images were recorded in five horses in life with a Diasonics DRF100 ultrasound system and a 3.5 MHz transducer in different tomographic planes. After slaughter, the hearts were fixed in 10 per cent formalin. To compare in vivo and in vitro results, the specimens were suspended in a water-filled tank and 2DE images were made using the same transducer positions as in life. In vitro 2DE and autopsy measurements ...
Left ventricular volume determination in the horse by two-dimensional echocardiography: an in vitro study. This study was designed to evaluate the accuracy of two-dimensional echocardiography (2DE) in determining the left ventricular volume (LVV) of the horse in vitro. After examining the shape of the left ventricular silicon rubber casts of four equine hearts, two modified Simpson's rule methods (Model A and Model B) as combinations of conical shapes and one biplane area-length method as a single cone (Model C) were chosen for volume calculations. One long axis and three short axis planes were used for linear and area 2DE measurements, respectively. The ventricular length (L) was calculated from t...