Analyze Diet

Topic:Electrocardiography

Electrocardiography (ECG) in horses is a diagnostic tool used to assess the electrical activity of the heart. It involves recording the electrical impulses that govern heartbeats, providing insights into cardiac function and rhythm. This non-invasive method is useful for identifying arrhythmias, conduction disturbances, and other cardiac abnormalities in equine patients. Electrocardiography can be performed at rest or during exercise to evaluate cardiac performance under different physiological conditions. This page compiles peer-reviewed research studies and scholarly articles that explore the methodology, interpretation, and clinical applications of electrocardiography in equine health.
[ECG similarities in the parents and offspring of thoroughbred horses].
Veterinarni medicina    February 1, 1982   Volume 27, Issue 2 87-93 
Hanák J, Zert Z.The ECG characters were studied in two sires (Manrico and Infernal) and their 26-membered set of progeny as well as in one mare (Victoire) and her five daughters. The confer of some ECG characters from the sire's side as well as from the mare's side to the offspring was demonstrated. The consistency of some ECG characters was particularly obvious in externally dominant Manrico sire and his offspring as well as in the breeding mare and her five daughters (inclination of the electric cardiac axis, intrinsicoid deflexion lag, P wave shape, deep S in the 3rd connection).
Equine laryngeal hemiplegia part II: Some clinical observations.
New Zealand veterinary journal    November 1, 1981   Volume 29, Issue 11 194-198 doi: 10.1080/00480169.1981.34846
Goulden BE, Anderson LJ.Some clinical features of laryngeal hemiplegia in 127 horses are described. Possible aetiologic factors were found in only 11% of affected animals. The onset of clinical signs was either sudden or insidious. The majority of cases were presented because of an abnormal respiratory noise made at exercise. Other clinical signs, particularly those usually attributed to laryngopalatal dislocation, were observed in a substantial proportion of affected animals. In all cases surveyed the left arytenoid was affected, although in 3 animals a bilateral laryngeal dysfunction was noted. Thirty of 65 animals...
ECG of the month: a 17-year-old mare with placenta retention.
Journal of the American Veterinary Medical Association    June 15, 1981   Volume 178, Issue 12 1258-1259 
Scarratt K, Lombard CW.No abstract available
Monitoring the anesthetized horse.
The Veterinary clinics of North America. Large animal practice    May 1, 1981   Volume 3, Issue 1 111-133 doi: 10.1016/s0196-9846(17)30149-0
Manley SV.The objectives of monitoring are to gain much information as possible about the anesthetized horse and to follow changes in that information, with the ultimate aim of making anesthesia and surgery as safe as possible for the horse. Information necessary to achieve that aim will vary depending on patient category. For example, a young, healthy horse undergoing a short elective procedure can be clinically well monitored by patient signs, electrocardiogram, and indirect blood pressure response. More invasive monitoring is justified and warranted if the health status of the horse is in question. T...
ECG of the month: an 11-year-old quarter horse following a maxillary laceration.
Journal of the American Veterinary Medical Association    April 15, 1981   Volume 178, Issue 8 803-804 
Raffe MR, Ogburn PN, McGrath CJ.No abstract available
Effects of xylazine and ketamine hydrochloride on the electroencephalogram and the electrocardiogram in the horse.
American journal of veterinary research    April 1, 1981   Volume 42, Issue 4 615-619 
Purohit RC, Mysinger PW, Redding RW.A continuous series of electroencephalograms (EEG) was obtained from each of 6 mature horses which had been given xylazine and ketamine hydrochloride IV. Electrocardiograms and respiratory rates were also obtained. The EEG of the unsedated standing adult horse displayed a dominant fast activity in the range of 25-35 Hz, 5-30 microV superimposed over slower 1-4 Hz, 10-50 microV activity with occasional 10-14 Hz, 10-40 microV spindle-type activity. The xylazine-sedated horse displayed hypersynchronous EEG patterns, with the dominant activity being 1-3 Hz, 10-70 microV with overlying mixed freque...
[The ST-segment and T-wave in the ECG of horses].
Berliner und Munchener tierarztliche Wochenschrift    March 1, 1981   Volume 94, Issue 5 81 
Grauerholz H.No abstract available
[Studies of the ST-segment and T-wave in the ECG of horses].
Berliner und Munchener tierarztliche Wochenschrift    February 15, 1981   Volume 94, Issue 4 71-76 
Grauerholz H.No abstract available
[Changes in the configuration of the QRS complex in ECG of racehorses during their 1st year of training].
Zentralblatt fur Veterinarmedizin. Reihe A    January 1, 1981   Volume 28, Issue 2 102-112 
Fister D, Deegen E, Lieske R.No abstract available
[Practolol test for adrenergic beta receptor blockade in veterinary electrocardiographic diagnosis].
Polskie archiwum weterynaryjne    January 1, 1981   Volume 23, Issue 1 95-101 
Grodzki K.The receptor theory of the action of catecholamines as well as the synthesis and production of beta-adrenolytics gave new perspectives for the treatment of circulatory diseases and enabled to use the beta-adrenergic blockade in electrocardiographic diagnosis. The aim of this work was to study whether it is possible to modify the oral method of administration used in human beings, into intravenous one, and what an information could be obtained as to actual heart condition after practolol injection. The results can be summarized as follows:--Practolol-Polfa injected intravenously in amounts of 3...
Cardiopulmonary effects of butorphanol tartrate in horses.
American journal of veterinary research    January 1, 1981   Volume 42, Issue 1 41-44 
Robertson JT, Muir WW, Sams R.The cardiopulmonary and behavioral effects of butorphanol were evaluated in pain-free adult horses. Butorphanol tartrate was administered IV in doses of 0.1, 0.2, and 0.4 mg/kg to the same horses on 3 separate occasions. There were no significant (P less than 0.05) changes in heart rate, mean and diastolic arterial pressure, mean and diastolic pulmonary arterial blood pressure, or cardiac output recorded in the horses given these doses. Systolic arterial blood pressure was significantly (P less than 0.05) increased in only the horses given the 0.2 mg/kg dose. Significant (P greater than 0.05) ...
[Diagnostic significance of the equine electrocardiogram (author’s transl)].
Tijdschrift voor diergeneeskunde    December 1, 1980   Volume 105, Issue 23 1019-1025 
Kroneman J.The anatomical and electrophysiological basis of the electrocardiogram are described. Attention is drawn to the fact that the technique of recording has not been standardized and to the failure to file the data obtained on an international scale. Today the ECG is only useful in recording arrhythmias, the clinical significance of which is estimated empirically.
[The effect of age and training on the ECG time curve of purebred horses].
Veterinarni medicina    November 1, 1980   Volume 25, Issue 11 683-689 
Hanák J, Jagos P.In 246 horses of the English Thoroughbred breed of several age categories, divided into four test populations, the influence was studied of age and training on the pulse rate and time intervals of ECG (PQ, QRS, QT and QTc). It was found that with the increasing age and training action slowed down gradually. Duration of the atrioventricular path (PQ) is prolonged, time of ventricular activation (QRS) and time of the electrical systole (QT) including its value corrected according to the actual pulse rate (QTC). In this way the origin of the so called sports electrocardiogram in trained race hors...
The use of electrocardiography to estimate heart weight and predict performance in the racehorse.
Australian veterinary journal    November 1, 1980   Volume 56, Issue 11 557-559 doi: 10.1111/j.1751-0813.1980.tb02592.x
No abstract available
[QRS complex in the ECG of the horse].
Berliner und Munchener tierarztliche Wochenschrift    August 15, 1980   Volume 93, Issue 16 301-309 
Grauerholz H.No abstract available
Limitations in equine fetal electrocardiography.
Journal of the American Veterinary Medical Association    July 15, 1980   Volume 177, Issue 2 174-176 
Buss DD, Asbury AC, Chevalier L.Technical and interpretive limitations of equine fetal electrocardiography were evaluated in recordings obtained from 45 pregnant mares. Technical limitations were related to the small amplitude of the fetal electrocardiogram and the variability in the lead configuration providing the best recording. It was found that recording the fetal electrocardiogram at high sensitivity and high base-line fidelity in several different leads was necessary to obtain satisfactory tracings. Interpretive limitations were related in part to the small amplitude of the fetal electrocardiogram and to the marked va...
Electrocardiography and haematology of horses competing in a three-day event.
Australian veterinary journal    July 1, 1980   Volume 56, Issue 7 318-320 doi: 10.1111/j.1751-0813.1980.tb05737.x
Rose RJ, Backhouse JW, Ilkiw JE.The electrocardiograms of 22 horses competing in a 3-day event were recorded before and after the event. In addition, blood samples were taken for determination of packed cell volume and total plasma protein before, during and after the speed and endurance phases (Day 2). The electrocardiograms of 13 horses showed various abnormalities before the event, most of which were T wave changes. As a result of competition in the event, there was a significant increase in the number of leads showing T wave abnormalities when the electrocardiograms taken before and after the event were compared. At all ...
[Electrocardiography alterations in horses caused by preanesthetic medication with combelen].
Berliner und Munchener tierarztliche Wochenschrift    May 1, 1980   Volume 93, Issue 9 163-166 
Grauerholz H, Fries I.No abstract available
Electrocardiography in the horse. (A report of findings in 138 horses).
Nordisk veterinaermedicin    March 1, 1980   Volume 32, Issue 3-4 105-121 
Vibe-Petersen G, Nielsen K.Over a period of approx. 3 years, electrocardiograms (ECG) were recorded from 138 horses referred as patients to the Medical Clinic. Of these, 22 horses (approx. 16 per cent) has ECG alterations. The 22 ECG's revealed a total of 29 ECG abnormalities. The most frequent ECG alteration was incomplete AV block, that was seen in 9 horses (31 per cent of the ECG abnormalities). Abnormal (i.e. broad, tent-like and, sometimes, inverted) T waves and deviations of the ST segment were seen each in 5 ECG's from 7 horses, 3 of which had both abnormalities which were associated with severe underlying diseas...
[Vectorial analysis of the electrocardiogram of the horse and the dog. A computer-based evaluation procedure for serial studies].
Zentralblatt fur Veterinarmedizin. Reihe A    February 1, 1980   Volume 27, Issue 1 33-44 
Grauerholz H.No abstract available
Ventricular defibrillation with myocardial electrodes in the dog, calf, pony, and pig.
Medical instrumentation    January 1, 1980   Volume 14, Issue 1 19-22 
Gold JH, Schuder JC, Stoeckle H.The defibrillation effectiveness of 4-msec rectangular wave shocks was evaluated using myocardial electrodes with 25-kg dogs and (nominally) 100-kg calves, ponies, and pigs as part of an evaluation of the suitability of these animals as models for automatic implanted defibrillator research. The percent success of defibrillation attempts in dogs ranged from 44% with 4-A, 6-J shocks to 93% with 8-A, 16-J shocks. The success achieved in calves with scaled electrodes was uniformly lower and reached a maximum of 28% with 23-A, 107-J shocks. Pigs defibrillated with scaled electrodes at a success lev...
[Forms of the vector loops in the atrial electrocardiogram of the horse].
Berliner und Munchener tierarztliche Wochenschrift    October 15, 1979   Volume 92, Issue 20 394-398 
Grauerholz H.No abstract available
[The P-wave in the EKG of healthy horses].
Berliner und Munchener tierarztliche Wochenschrift    September 15, 1979   Volume 92, Issue 18 349-352 
Grauerholz H.No abstract available
Electrocardiography, heart scope and haematology of horses competing in an endurance ride.
Australian veterinary journal    June 1, 1979   Volume 55, Issue 6 247-250 
Rose RJ, Ilkiw JE, Hodgson D.Thirty-one horses competing in a 100 kilometre endurance ride had electrocardiograms recorded before and after the ride from which the heart score of each horse was calculated. Blood was also taken to determine the packed cell volume (PCV) and total plasma protein (TPP) before the ride, after 60 kilometres (mid ride) and at completion of the ride. Statistical analysis of the heart scores showed that a faster group of horses had significantly higher heart scores than either a slower group or those eliminated due to inadequate recovery of heart rate. No horses developed electrocardiogram abnorma...
Electrocardiography, Heart Score, and Hematology of Horses Competing in an Endurance Ride.
Australian veterinary journal    May 1, 1979   Volume 55, Issue 5 247-250 doi: 10.1111/j.1751-0813.1979.tb00389.x
Rose RJ, Ilkiw JE, Hodgson D.Thirty-one horses competing in a 100 kilometre endurance ride had electrocardiograms recorded before and after the ride from which the heart score of each horse was calculated. Blood was also taken to determine the packed cell volume (PCV) and total plasma protein (TPP) before the ride, after 60 kilometres (mid-ride) and at completion of the ride. Statistical analysis of the heart scores showed that a faster group of horses had significantly higher heart scores than either a slower group or those eliminated due to inadequate recovery of heart rate. No horses developed electrocardiogram abnorma...
[Changes in the electrocardiogram of horses with chronic bronchitis and their sequelae].
Berliner und Munchener tierarztliche Wochenschrift    March 1, 1979   Volume 92, Issue 5 85-89 
Grauerholz H.No abstract available
Haemodynamics in the horse: 3. Duration of the phases of the cardiac cycle.
Equine veterinary journal    October 1, 1978   Volume 10, Issue 4 216-223 doi: 10.1111/j.2042-3306.1978.tb02265.x
Brown CM, Holmes JR.The paper reports observations on the duration of various phases of the cardiac cycle using a bipole ECG record as a time base from which to measure the timing of pressure changes in the chambers of the heart and great vessels. From the findings the likely sequence of mechanical events during the cardiac cycle in the atria and ventricles is described.
Electrode-saddle for electrocardiogram recording in large animals.
The Canadian veterinary journal = La revue veterinaire canadienne    September 1, 1978   Volume 19, Issue 9 248-249 
Deroth L, Therien A.No abstract available
Haemodynamics in the horse: 1. Pressure pulse contours.
Equine veterinary journal    July 1, 1978   Volume 10, Issue 3 188-194 doi: 10.1111/j.2042-3306.1978.tb02257.x
Brown CM, Holmes JR.Using a catheter with 2 transducers, one mounted at the tip and one 9 cm proximal to it, enabled transvalval pressure waveforms to be recorded in 8 horses. A simultaneous electrocardiogram acted as a time base. The changing waveforms produced in the chambers of the heart and great vessels are described and related to the events of the cardiac cycle. The effect of second degree AV block, ectopic beats, a pan diastolic murmur and chronic obstructive pulmonary disease are described.
The use of electrocardiography in the diagnosis of poor racing performance in the horse.
Australian veterinary journal    February 1, 1978   Volume 54, Issue 2 51-56 doi: 10.1111/j.1751-0813.1978.tb00341.x
Rose RJ, Davis PE.Electrocardiograms were reocrded from 153 racehorses and 10 Olympic three-day-event horses. The horses were then grouped into those presented for routine examination, those in which there was a complaint of poor performance, those going to the Montreal Olympics, and those with upper respiratory tract abnormalities. When the ECGs of the four groups were compared on the basis of detection of abnormality, it was found that 93.2% of the poor performance group showed abnormalities of various types. The routine examination group showed 21.1% of horses with abnormal ECGs, and over half of these have ...