Electrocardiography (ECG) in horses is a diagnostic tool used to assess the electrical activity of the heart. It involves recording the electrical impulses that govern heartbeats, providing insights into cardiac function and rhythm. This non-invasive method is useful for identifying arrhythmias, conduction disturbances, and other cardiac abnormalities in equine patients. Electrocardiography can be performed at rest or during exercise to evaluate cardiac performance under different physiological conditions. This page compiles peer-reviewed research studies and scholarly articles that explore the methodology, interpretation, and clinical applications of electrocardiography in equine health.
Ter Woort F, Dubois G, Tansley G, Didier M, Verdegaal L, Franklin S, Van Erck-Westergren E.Cardiac arrhythmias in exercising horses are the focus of much interest, both in terms of what is considered normal and potential associations with poor performance and sudden cardiac death. One barrier to performing large-scale studies is the lack of an easily applicable device, to allow recording of large numbers of high-quality exercising electrocardiograms (ECGs). The Equimetre is a new wearable device which records a single lead ECG, amongst other parameters. Validation of such wearable devices is essential before further studies are undertaken. Objective: To evaluate the quality of ECG u...
Buhl R, Hesselkilde EM, Carstensen H, Hopster-Iversen C, van Loon G, Decloedt A, Van Steenkiste G, Marr CM, Reef VB, Schwarzwald CC, Mitchell KJ....The recurrence rate of atrial fibrillation (AF) in horses after cardioversion to sinus rhythm (SR) is relatively high. Atrial fibrillatory rate (AFR) derived from surface ECG is considered a biomarker for electrical remodelling and could potentially be used for the prediction of successful AF cardioversion and AF recurrence. Objective: Evaluate if AFR was associated with successful treatment and could predict AF recurrence in horses. Methods: Retrospective multicentre study. Methods: Electrocardiograms (ECG) from horses with persistent AF admitted for cardioversion with either medical treatmen...
Nath LC, Forbes G, Elliott AD, Tomren V, Ryan A, Franklin SH.AliveCor is a smartphone electrocardiography device (iECG) providing automated heart rate (HR) and rhythm determination. Atrial fibrillation (AF) in horses often is paroxysmal and rapid ECG acquisition is needed for diagnostic confirmation. iECGs were collected post-race from 15 horses with AF and 64 horses in sinus rhythm (SR). Results of manual assessment were compared to 3 commercial algorithms for HR and rhythm. Agreement between manually derived HR (HRM ) and HR derived by the AliveECG Vet (HRVET ) and Kardia version-1 (KV1 HR) and Kardia advanced (KADV HR) algorithms was quantified by th...
The incidence of significant arrhythmias in sport horses and knowledge about their exact influence on athletic performance need to be clarified. The aims of the present study are to report the prevalence of cardiac arrhythmias during maximal treadmill exercise in poorly performing Standardbreds, and to investigate the possible relationship of demographic, cardiac and performance indices on premature complexes (PCs). Electrocardiographic Holter recordings before, during and after treadmill exercise testing of 158 poorly performing Standardbreds were analyzed retrospectively. Fifty horses did no...
Vitale V, Vezzosi T, Tognetti R, Fraschetti C, Sgorbini M.Recently, the use of smartphone ECG devices has been reported in humans and animals. Nevertheless, as the electrodes of these devices are inseparable, they can create only a precordial reading in veterinary species. Thus, although the smartphone ECG devices are considered valuable as a screening tool for the detection of some common arrhythmias, they are not always a reliable method for the measurement of the duration of the electrical deflections. The objectives of this study were to evaluate the feasibility of a novel smartphone ECG device, to report the readings obtained recorded simultaneo...
Pedler C, Nath L, Agne GF, Hebart M, Franklin S.Atrial fibrillation (AF) is the most common performance-limiting arrhythmia of racehorses. A genetic contribution has been suggested in Standardbred racehorses but has not been investigated in Thoroughbreds. The objective of this study was to determine the heritability of AF in Thoroughbred racehorses. Methods: Horses racing between 2007 and 2019 in Hong Kong and Australia that had AF detected postrace via auscultation (n = 463 cases) were compared with five randomly selected racing contemporaries (n = 2,315 controls). The ASReml-R programme was used to fit an animal model to the AF data t...
Sedlinská M, Kabeš R, Novák M, Kološ F, Melková P.A five-month-old African jenny was presented with a history of exercise intolerance and syncopal episodes. Severe bradycardic arrhythmia due to a high-grade second-degree atrioventricular (AV) block with progression to complete AV block was diagnosed. The jenny underwent a transvenous single-chamber pacemaker implantation. The implantation procedure was performed in a lateral recumbency and the ventricular lead was inserted through the jugular vein. Positioning of the lead was guided by echocardiography. The pacemaker was programmed to VVI mode with a minimal ventricular rate of 40 pulses per ...
Trachsel DS, Calloe K, J Rgensen E, Lunddahl CS, Pedersen PJ, Kanters JRK, Klaerke DA, Buhl R.To determine whether administration of trimethoprim-sulfadiazine (TMS), detomidine (DET), or TMS plus DET would be associated with changes in ECG repolarization parameters in horses. Methods: 9 healthy adult horses. Methods: Each horse received 4 treatments in a blinded, randomized, crossover study design as follows: TMS, 16 to 24 mg/kg, IV; DET, 0.015 to 0.02 mg/kg, IV; TMS plus DET; and saline (0.9% NaCl) solution. Surface ECG traces were obtained over 24 hours, and repolarization parameters were measured at predefined time points after each treatment and compared with a 2-way ANOVA for repe...
Li N, Yu J, Yang F, Shao Y, Wu S, Liu B, Li M, Wang T, Li J, Zeng S.The aim of this study was to evaluate the effects of L-proline on the extender quality of frozen and post-thawed jackass semen. Jackass (n = 6) semen samples were collected and cryopreserved in gradient concentrations (0-80 mM) of L-proline in extenders; post-thawed semen samples were cultured in L-proline medium for 10 hours at 37°C. For cryopreservation experiment I, the motile parameters, mitochondrial membrane potential (MMP), and plasma membrane, acrosome, and chromatin structure integrities of post-thawed semen were assessed. For culture experiment II, additional ROS contents were ana...
Van Steenkiste G, Carlson J, Decloedt A, Vera L, Buhl R, Platonov PG, van Loon G.To compare the atrial fibrillatory rate (AFR) derived from a local right atrial intracardiac recording (RA-FR) and from a single-lead surface electrocardiogram (ECG) during atrial fibrillation (AF) and to evaluate the correlation with transvenous electrical cardioversion (TVEC) threshold (in Joules), number of shocks and cardioversion success rate in horses. Methods: ECGs and clinical records of horses with AF treated by TVEC. Horses were included if a simultaneous recording of the right atrial intracardiac electrogram and a modified base-apex ECG were available. Methods: Clinical records of h...
Keen JA, O'Connor SA.Short-term electrocardiogram (ECG) examinations of horses may not detect paroxysmal arrhythmias. Twenty-four hour Holter equipment can be unwieldy and inconvenient for long-term use. This study evaluated a novel long-term ECG patch recorder, the Carnation Ambulatory Monitor (CAM) in horses, determining ideal placement, practicality, durability and performance. Methods: Twenty-one adult mixed-breed horses. Methods: Prospective observational study. Three horses had ECG patches fitted at selected sites (phase 1); the two most promising sites were used for further wear testing (phase 2) and the b...
Decloedt A, Van Steenkiste G, Vera L, Buhl R, van Loon G.Atrial fibrillation (AF) is suspected by an irregularly irregular rhythm during auscultation at rest and should be confirmed by electrocardiography. Heart rate monitoring is potentially interesting for AF detection by horse owners, based on the disproportionally high heart rate during exercise or increased heart rate variability. Echocardiography and laboratory analysis are useful to identify underlying cardiac disease. Horses with severe cardiac disease should not undergo cardioversion due to the risk of recurrence. Cardioversion is recommended especially in horses performing high intensity e...
Alberti E, Stucchi L, Pesce V, Stancari G, Ferro E, Ferrucci F, Zucca E.Due to compactness and cheapness, smartphone ECG (sECG) could be very useful to equine practitioners. However, previous studies have evaluated the accuracy of sECG in hospitalised horses only. Different conditions in the field could influence the accuracy of the device. The aim of this study is to compare the accuracy of sECG in field and in hospital conditions. Methods: This is a prospective study. Paired standard base-apex ECG (stECG) and sECG were recorded in hospitalised horses and in subjects examined in field conditions. ECGs were analysed for heart rate and rhythm, presence/type of arrh...
Hesselkilde EM, Isaksen JL, Petersen BV, Carstensen H, Jespersen T, Pehrson S, Kanters JK, Buhl R.In equine medicine, 12-lead electrocardiograms (ECGs) rarely are used, which may in part be a result of shortcomings in the existing guidelines for obtaining 12-lead ECGs in horses. The guidelines recommend placing the limb leads on the extremities, which is inappropriate because the ventricular mean electrical axis is then perpendicular to the limb leads, leading to large variations in ECG configuration even among healthy horses. From an electrophysiological point of view, the leads instead should be parallel to the electrical axis to minimize variability. Objective: Develop an improved metho...
Mitchell KJ, Schwarzwald CC.Heart rate variability (HRV) analysis has been performed on ECG-derived data sets for more than 170 years but is currently undergoing a rapid evolution, thanks to the expansion of the human and veterinary medical technology sector. Traditional HRV analysis was initially performed to identify changes in vago-sympathetic balance, while the most recent focus has expanded to include the use of complex computer algorithms, neural networks and machine learning technology to identify cardiac arrhythmias, particularly atrial fibrillation (AF). Some of these techniques have recently been translated for...
Massie SL, Bezugley RJ, McDonald KJ, Leguillette R.The prevalence and severity of cardiac arrhythmias in healthy racehorses undergoing competition is not well defined. The aim was to characterize arrhythmias in Thoroughbreds participating in official Chuckwagon races and to determine normal beat-to-beat (R-R) variability during supramaximal exercise. Electrocardiograph (ECG) recordings were obtained during pre-race, race, and active-recovery from 82 clinically healthy Thoroughbreds. ECG recordings were analyzed for arrhythmias and mean percent R-R deviation. Plasma lactate and high-sensitivity troponin (hs-cTnT) were also measured. Fifty-two E...
Buhl R, Nissen SD, Winther MLK, Poulsen SK, Hopster-Iversen C, Jespersen T, Sanders P, Carstensen H, Hesselkilde EM.Limited information is available on paroxysmal atrial fibrillation (PAF) in the horse. Indeed, undiagnosed PAF could result in poor performance. Due to the intermittent occurrence, PAF is difficult to diagnose. However, implanting a small ECG device (implantable loop recorder, ILR) subcutaneously, allows the continuous and automatic detection of PAF. Objective: The aim was to investigate the potential of ILRs as a tool for diagnosing PAF in horses with poor performance. Methods: Prospective field study. Methods: Twelve racing Standardbred trotters with intermittent reduced performance (mean ag...
Huang YH, Alexeenko V, Tse G, Huang CL, Marr CM, Jeevaratnam K.Atrial fibrillation is the most frequent arrhythmia in both equine and human athletes. Currently, this condition is diagnosed via electrocardiogram (ECG) monitoring which lacks sensitivity in about half of cases when it presents in paroxysmal form. We investigated whether the arrhythmogenic substrate present between the episodes of paroxysmal atrial fibrillation (PAF) can be detected using restitution analysis of normal sinus-rhythm ECGs. In this work, ECG recordings were obtained during routine clinical work from control and horses with PAF. The extracted QT, TQ, and RR intervals were used fo...
Marr CM, Franklin S, Garrod G, Wylie C, Smith L, Dukes-McEwan J, Bright J, Allen K.Exercise-associated cardiac rhythm disturbances are common, but there is a lack of evidence-based criteria on which to distinguish clinically relevant rhythm disturbances from those that are not. Objective: To describe and characterise rhythm disturbances during clinical exercise testing; to explore potential risk factors for these rhythm disturbances and to determine whether they influenced future racing. Methods: Retrospective cohort using a convenience sample. Methods: Medical records were reviewed from two clinical services to identify horses with poor performance and/or respiratory noise ...
Corradini I, Fernández-Ruiz A, Barba M, Engel-Manchado J.Comparisons between smartphone ECG (SpECG) recordings obtained from the right and left sides of the thorax have not been reported in animals. Objective: To evaluate the screening potential of a SpECG obtained from both sides of the thorax and to compare the degree of agreement between the SpECG and a reference ECG (rECG) for measurement of the duration of baseline electrical deflections recorded over both sides of the thorax. Methods: Fifty horses admitted to the equine hospital, university-owned horses, and horses from an endurance riding facility. Methods: Prospective observational study. Si...
There are several bioengineering solutions aimed at improving human health and welfare. Smart electrodes based on textile substrates have met the growing demand for comfort, reliability, and robustness when acquiring physiological signals. Objective: Given the importance of good quality electrocardiograms (ECG) in equine sports medicine, this study focuses on the validation of smart textile electrodes to acquire ECG signals in horses during treadmill exercise. Methods: The performance of the smart textile electrodes is compared with standard silver/silver chloride (Ag/AgCl) electrodes in terms...
Drábková Z, Amory H, Kabeš R, Melková P, van Loon G.A partial atrioventricular septal defect, represented as a large ostium primum atrial septal defect and common (bridging) atrioventricular valve leaflets with cleft septal leaflet of the mitral valve, was diagnosed incidentally in a nine-year-old warmblood gelding used for show jumping. Initial examination findings and a three-year follow-up are documented in this report. The horse was first presented for the evaluation of chronic coughing. A left-sided, grade 4/6 holosystolic (band-shaped) murmur was identified along with a similar right-sided, grade 3/6 heart murmur. Echocardiography reveale...
Cherdchutham W, Koomgun K, Singtoniwet S, Wongsutthawart N, Nontakanun N, Wanmad W, Petchdee S.The objective of this study was to assess a new lead system method to improve electrocardiographic measurement in horses. Methods: Twenty-two horses with an average age of 8.8±0.8 years were enrolled in this study. Horses were divided into two groups, consisting of a control group (n=11) and athlete group (n=11). Electrocardiography (ECG) and echocardiography were performed to provide information on the structure and function of the heart. Two lead systems, base apex and modified precordial leads, were used for the electrocardiogram to assess the cardiac electrophysiological functions. Result...
Buhl R, Hesselkilde EM, Carstensen H, Fenner MF, Jespersen T, Tfelt-Hansen J, Michael Sattler S.Cardiac arrhythmias in horses are diagnosed by auscultation or electrocardiogram (ECG), which results in a low sensitivity for detecting arrhythmias that occur sporadically. Implantable loop recorders (ILRs) are small ECG devices placed subcutaneously, to automatically detect arrhythmias in human patients. Objective: To test ILRs ability to detect atrial fibrillation (AF) in horses. Furthermore, we hypothesised that anatomical location of the implant site might influence signal quality. Signal quality was evaluated both during exercise and over time. Methods: Experimental study. Methods: In fi...
Restan AZ, Camacho AA, Cerqueira JA, Zacché E, Kirnew MD, Loureiro BA, Silva SB, Moranza HG, Ferraz GC.The dogs' responses to training exercise are seldom monitored using physiological variables, and cardiac autonomic regulation (CAR) is a relevant determinant of endurance-training adaptation. There are studies in the literature establishing that regular exercise could interfere with CAR in dogs, measured by heart rate and vagal-derived indexes of heart-rate-variability (HRV). However, few studies were found using a prescribed training program based on the lactate threshold (LT) to determine HRV by a 24-h Holter analysis. The purpose of this study was to test whether an endurance-training progr...
Welch-Huston B, Durward-Akhurst S, Norton E, Ellingson L, Rendahl A, McCue M.Cardiac arrhythmias are commonly auscultated during routine physical examinations in horses and determining the underlying electrical abnormality using an ECG is important. The most commonly used device is a three-lead base apex system (Televet), however few practitioners carry this for routine visits. With recognition of the utility of smartphone-based ECGs in humans, dogs and ruminants, the AliveCor single-lead bipolar smartphone-based ECG has gained popularity. The objective of this study was to determine if AliveCor and Televet ECG measurements were comparable in healthy horses using multi...
Recchi L, Alvariza S, Benech A, Ruiz N, José Estradé M, Suarez G, Crosignani N.The purpose of this study was to evaluate the pharmacokinetics of oral amitriptyline in horses. Oral amitriptyline (1 mg/kg) was administered to six horses. Blood samples were collected from jugular and lateral thoracic vein at predetermined times from 0 to 24 hr after administration. Plasma concentrations were determined by high-performance liquid chromatography and analyzed using noncompartmental methods. Pharmacodynamic parameters including heart rate, respiration rate, and intestinal motility were evaluated, and electrocardiographic examinations were performed in all subjects. The mean m...
Alexeenko V, Fraser JA, Bowen M, Huang CL, Marr CM, Jeevaratnam K.Equine athletes have a pattern of exercise which is analogous to human athletes and the cardiovascular risks in both species are similar. Both species have a propensity for atrial fibrillation (AF), which is challenging to detect by ECG analysis when in paroxysmal form. We hypothesised that the proarrhythmic background present between fibrillation episodes in paroxysmal AF (PAF) might be detectable by complexity analysis of apparently normal sinus-rhythm ECGs. In this retrospective study ECG recordings were obtained during routine clinical work from 82 healthy horses and from 10 horses with a ...
Alexeenko V, Fraser JA, Bowen M, Huang CL, Marr CM, Jeevaratnam K.Equine athletes have a pattern of exercise which is analogous to human athletes and the cardiovascular risks in both species are similar. Both species have a propensity for atrial fibrillation (AF), which is challenging to detect by ECG analysis when in paroxysmal form. We hypothesised that the proarrhythmic background present between fibrillation episodes in paroxysmal AF (PAF) might be detectable by complexity analysis of apparently normal sinus-rhythm ECGs. In this retrospective study ECG recordings were obtained during routine clinical work from 82 healthy horses and from 10 horses with a ...
Li N, Yu J, Yang F, Shao Y, Wu S, Liu B, Li M, Wang T, Li J, Zeng S.The aim of this study was to evaluate the effects of L-proline on the extender quality of frozen and post-thawed jackass semen. Jackass (n = 6) semen samples were collected and cryopreserved in gradient concentrations (0-80 mM) of L-proline in extenders; post-thawed semen samples were cultured in L-proline medium for 10 hours at 37°C. For cryopreservation experiment I, the motile parameters, mitochondrial membrane potential (MMP), and plasma membrane, acrosome, and chromatin structure integrities of post-thawed semen were assessed. For culture experiment II, additional ROS contents were ana...
Ohmura H, Hiraga A, Aida H, Kuwahara M, Tsubone H.To investigate the effects of repeated atropine injection on heart rate (HR) variability in resting Thoroughbred horses, two microg/ kg of atropine as parasympathetic nervous blockade was injected intravenously every 6 min to a total of 8 microg/kg after intravenous administration of 0.2 mg/kg of propranolol as sympathetic nervous blockade. We recorded electrocardiograms and obtained the HR, then evaluated variation in HR from the power spectrum in terms of low frequency (LF, 0.01-0.07 Hz) power and high frequency (HF, 0.07-0.6 Hz) power. Administration of atropine decreased parasympathetic ne...
Gunther-Harrington CT, Arthur R, Estell K, Martinez Lopez B, Sinnott A, Ontiveros E, Varga A, Stern JA.Exercise induced cardiac fatigue (EICF) and cardiac dysrhythmias are well described conditions identified in high-level human athletes that increase in frequency with intensity and duration of exercise. Identification of these conditions requires an understanding of normal pre- and post-race cardiac assessment values. The objectives of this study were to (1) characterize selected indices of cardiac function, electrophysiologic parameters, and biochemical markers of heart dysfunction prior to and immediately after high level racing in Thoroughbred horses receiving furosemide; and (2) create pre...
Pedersen PJ, Karlsson M, Flethøj M, Trachsel DS, Kanters JK, Klaerke DA, Buhl R.Quantitative measurements of cardiac repolarization, defined as the electrocardiographic QT interval, have important diagnostic implications in humans, as irregularities can trigger potentially fatal ventricular tachyarrhythmia. In both humans and horses, cardiac repolarization is influenced to some extent by heart rate, age, body weight (BW), sex, autonomic tone, and environment. In horses, there is substantial inter-breed variation in size and training, and the aims of this study were therefore to determine the best model describing the QT to RR relationship in breeds of various athletic hor...
Aleman M, Williams DC, Guedes A, Madigan JE.An overdose of pentobarbital sodium administered i.v. is the most commonly used method of euthanasia in veterinary medicine. Determining death after the infusion relies on the observation of physical variables. However, it is unknown when cortical electrical activity and brainstem function are lost in a sequence of events before death. Objective: To examine changes in the electrical activity of the cerebral cortex and brainstem during an overdose of pentobarbital sodium solution for euthanasia. Our testing hypothesis is that isoelectric pattern of the brain in support of brain death occurs bef...
van Loon G, Fonteyne W, Rottiers H, Tavernier R, Jordaens L, D'Hont L, Colpaert R, De Clercq T, Deprez P.The purpose of the present study was to develop a feasible and safe technique for dual-chamber pacemaker implantation in healthy horses. Implantation was performed in a standing, tranquilized horse and in ponies. Atrial and ventricular leads were transvenously inserted through the cephalic vein, and a subcutaneous pacemaker pocket was created between the lateral pectoral groove and the manubrium sterni in 6 equids. Positioning of each lead was guided by echocardiography and by measuring the electrical characteristics of the lead. The implantation procedure lasted about 4 hours in each animal a...
Holmes JR, Alps BJ.The paper describes observations on the distributions of the P, QRS and T cardiac vectors in the horizontal plane in 377 apparently healthy horses. The possible usefulness of vectorcardiography in the clinical evaluation of cardiac function is briefly discussed.
van Loon G, Fonteyne W, Rottiers H, Tavernier R, Deprez P.A five-year-old gelding suffered syncope at the end of a period of exercise. A 24-hour electrocardiogram recording revealed intermittent pauses in the sinus rhythm of up to 10 seconds, indicating sinus node disease; the pauses occurred repeatedly, particularly after exercise. A dual-chamber, rate-adaptive pacemaker was successfully implanted, which prevented excessive postexercise bradycardia and syncope, and allowed the horse to return to work.
Van Steenkiste G, L V, Decloedt A, Schauvliege S, Boussy T, van Loon G.Understanding the depolarisation pattern of the equine heart under normal physiologic conditions, and its relationship to the surface electrocardiogram (ECG), is of uppermost importance before any further research can be done about the pathophysiology of complex arrhythmias. In the present study, a 3D electro-anatomical mapping system was used to evaluate the qualitative and quantitative depolarisation patterns and correlation to the surface ECG of both the atrial and ventricular endocardium in seven healthy horses in sinus rhythm under general anaesthesia. Bipolar activation maps of the endoc...
Van Steenkiste G, Delhaas T, Hermans B, Vera L, Decloedt A, van Loon G.In human cardiology, the anatomical origin of atrial premature depolarizations (APDs) is derived from P wave characteristics on a 12-lead electrocardiogram (ECG) and from vectorcardiography (VCG). The objective of this study is to differentiate between anatomical locations of APDs and to differentiate APDs from sinus rhythm (SR) based upon VCG characteristics in seven horses without cardiovascular disease. A 12-lead ECG was recorded under general anaesthesia while endomyocardial atrial pacing was performed (800−1000 ms cycle length) at the left atrial free wall and septum, right atrial free ...
Schwarzwald CC, Kedo M, Birkmann K, Hamlin RL.To investigate the relationship of heart rate (HR) and ECG time intervals to body weight (BWT) in healthy horses and ponies. We hypothesized that HR and ECG time intervals are related to BWT. Methods: 250 healthy horses of >30 breeds; 5.5 (1-30) y [median (range)]; 479 (46-1018) kg. Methods: Prospective study. Standard base-apex ECGs were recorded while the horses were standing quietly in a box stall. Mean HR over 15 s was calculated and RR interval, PQ interval, QRS duration, and QT interval were measured by a single observer.QT was corrected for differences in heart rate using Fridericia'...
Vernemmen I, De Clercq D, Decloedt A, Vera L, Van Steenkiste G, van Loon G.The number of atrial premature depolarisations (APDs) is a known risk factor for atrial fibrillation (AF) recurrence in humans. Objective: To evaluate if the number of APDs over a 24-h period 5 days post cardioversion predicts AF recurrence within 1 year in horses, taking the multifactorial nature of AF into account. Methods: Retrospective case series. Methods: Eighty horses met these inclusion criteria: first AF episode, no AF recurrence within 5 days post cardioversion, cardioversion by transvenous electrical cardioversion (TVEC), 24-h ECG recording and echocardiographic examination 5 da...
Alberti E, Stucchi L, Pesce V, Stancari G, Ferro E, Ferrucci F, Zucca E.Due to compactness and cheapness, smartphone ECG (sECG) could be very useful to equine practitioners. However, previous studies have evaluated the accuracy of sECG in hospitalised horses only. Different conditions in the field could influence the accuracy of the device. The aim of this study is to compare the accuracy of sECG in field and in hospital conditions. Methods: This is a prospective study. Paired standard base-apex ECG (stECG) and sECG were recorded in hospitalised horses and in subjects examined in field conditions. ECGs were analysed for heart rate and rhythm, presence/type of arrh...
Broux B, De Clercq D, Vera L, Ven S, Deprez P, Decloedt A, van Loon G.Heart rate variability (HRV) parameters, and especially RMSSD (root mean squared successive differences in RR interval), could distinguish atrial fibrillation (AF) from sinus rhythm(SR) in horses, as was demonstrated in a previous study. If heart rate monitors (HRM) automatically calculating RMSSD could also distinguish AF from SR, they would be useful for the monitoring of AF recurrence. The objective of the study was to assess whether RMSSD values obtained from a HRM can differentiate AF from SR in horses. Furthermore, the impact of artifact correction algorithms, integrated in the analyses ...
Jose-Cunilleras E, Young LE, Newton JR, Marlin DJ.The prevalence and severity of cardiac arrhythmias during exercise in athletic horses presented for poor performance is not well described. Objective: To describe prevalence and severity of ventricular and supraventricular arrhythmias immediately before, during and immediately after standardised incremental treadmill exercise tests (IET) to fatigue in Thoroughbred horses during investigation of poor performance. Methods: The electrocardiograms (ECG) of 88 Thoroughbred racehorses, judged to be free of significant heart disease or arrhythmia at rest, were used. A modified base-apex ECG was recor...
Kato T, Ohmura H, Hiraga A, Wada S, Kuwahara M, Tsubone H.To determine the effects of immersion in warm springwater (38 degrees to 40 degrees C) on autonomic nervous activity in horses. Methods: 10 male Thoroughbreds. Methods: Electrocardiograms were recorded from horses for 15 minutes during a warm springwater bath after being recorded for 15 minutes during stall rest. Variations in heart rate (HR) were evaluated from the power spectrum in terms of low frequency (LF, 0.01 to 0.07 Hz) power and high frequency (HF, 0.07 to 0.6 Hz) power as indices of autonomic nervous activity. Results: Mean (+/- SE) HR during stall rest and immersion in warm springwa...
Li M, Chadda KR, Matthews GDK, Marr CM, Huang CL, Jeevaratnam K.Exercising horses uniquely accommodate 7-8-fold increases in heart rate (HR). The present experiments for the first time analysed the related adaptations in action potential (AP) restitution properties recorded by in vivo telemetric electrocardiography from Thoroughbred horses. The horses were subjected to a period of acceleration from walk to canter. The QRS durations, and QT and TQ intervals yielded AP conduction velocities, AP durations (APDs) and diastolic intervals respectively. From these, indices of active, λ = QT/(QRS duration), and resting, λ0 = TQ/(QRS duration), AP wavelengths wer...
Marr CM, Franklin S, Garrod G, Wylie C, Smith L, Dukes-McEwan J, Bright J, Allen K.Exercise-associated cardiac rhythm disturbances are common, but there is a lack of evidence-based criteria on which to distinguish clinically relevant rhythm disturbances from those that are not. Objective: To describe and characterise rhythm disturbances during clinical exercise testing; to explore potential risk factors for these rhythm disturbances and to determine whether they influenced future racing. Methods: Retrospective cohort using a convenience sample. Methods: Medical records were reviewed from two clinical services to identify horses with poor performance and/or respiratory noise ...
Raekallio M.The electrocardiogram of 9 horses was continuously recorded for 24 h with Holter monitoring to examine the variations in heart rate and rhythm during daily routine procedures and at night. Three horses had transient sinus bradycardia, and 3 had periods of sinus tachycardia. Heart blocks were detected in 3 horses, and all horses had periods of sinus arrhythmia. These changes in the heart rate and rhythm were apparently caused by variations in autonomic nervous system tone and they are probably "normal" findings in resting, undisturbed horses. Ventricular premature depolarisations were not obser...
McCrae P, Spong H, Golestani N, Mahnam A, Bashura Y, Pearson W.Electrocardiograms (ECGs), and associated heart rate (HR) and heart rate variability (HRV) measurements, are essential in assessing equine cardiovascular health and fitness. Smart textiles have gained popularity, but limited validation work has been conducted. Therefore, the objective of this study was to compare HR and HRV data obtained using a smart textile system (Myant) to the gold-standard telemetric device (Televet). Simultaneous ECGs were obtained using both systems in seven horses at rest and during a submaximal exercise test. Bland-Altman tests were used to assess agreement between th...
De Clercq D, van Loon G, Baert K, Tavernier R, Croubels S, De Backer P, Deprez P.Good results have been obtained with a human amiodarone (AD) i.v. protocol in horses with chronic atrial fibrillation (AF) and a pharmacokinetic study is required for a specific i.v. amiodarone treatment protocol for horses. Objective: To study the efficacy of this pharmacokinetic based i.v. AD protocol in horses with chronic AF. Methods: Six horses with chronic AF were treated with an adapted AD infusion protocol. The protocol consisted of 2 phases with a loading dose followed by a maintenance infusion. In the first phase, horses received an infusion of 6.52 mg AD/kg bwt/h for 1 h followed by...
Van Steenkiste G, De Clercq D, Boussy T, Vera L, Schauvliege S, Decloedt A, van Loon G.Ultra-high-density cardiac mapping allows very accurate characterisation of atrial and ventricular electrophysiology and activation timing. Objective: To describe the technique and evaluate the feasibility of magnetic electro-anatomical mapping of the equine heart. Methods: In vivo experimental method development. Methods: A mapping system using an 8.5F bidirectional deflectable catheter with a deployable mini-basket (3-22 mm) containing 64 electrodes divided over eight splines was evaluated. Based upon predefined beat acceptance criteria, the system automatically acquires endocardial electro...
McCrae P, Spong H, Rutherford AA, Osborne V, Mahnam A, Pearson W.Electrocardiography (ECG) is an essential tool in assessing equine health and fitness. However, standard ECG devices are expensive and rely on the use of adhesive electrodes, which may become detached and are associated with reduced ECG quality over time. Smart textile electrodes composed of stainless-steel fibers have previously been shown to be a suitable alternative in horses at rest and during exercise. The objective of this study was to compare ECG quality using a smart textile girth band knit with silver and carbon yarns to standard adhesive silver/silver chloride (Ag/AgCl) electrodes. S...
Kjeldsen ST, Nissen SD, Buhl R, Hopster-Iversen C.Atrial fibrillation (AF) is the most common arrhythmia in horses causing poor performance. As in humans, the condition can be intermittent in nature, known as paroxysmal atrial fibrillation (pAF). This review covers the literature relating to pAF in horses and includes references to the human literature to compare pathophysiology, clinical presentation, diagnostic tools and treatment. The arrhythmia is diagnosed by auscultation and electrocardiography (ECG), and clinical signs can vary from sudden loss of racing performance to reduced fitness or no signs at all. If left untreated, pAF may prom...
Aleman M, Davis E, Williams DC, Madigan JE, Smith F, Guedes A.An intravenous (IV) overdose of pentobarbital sodium is the most commonly used method of euthanasia in veterinary medicine. However, this compound is not available in many countries or rural areas resulting in usage of alternative methods such as intrathecal lidocaine administration after IV anesthesia. Its safety and efficacy as a method of euthanasia have not been investigated in the horse. Objective: To investigate changes in mean arterial blood pressure and electrical activity of the cerebral cortex, brainstem, and heart during intrathecal administration of lidocaine. Our hypothesis was th...
Hiraga A, Sugano S.Since the first recording of electrocardiograms (ECGs) of a horse in Japan was carried out in 1944, studies on ECGs have been performed intensively. During the early stages of research from the 1950s to 1960s, leads to use for ECG recording were evaluated using several different approaches including unipolar leads, bipolar limb leads, and bipolar chest leads. Based on these studies, the AB lead, which is oriented along the long axis of the heart, became the standard reference method in Japan. Electrodes of the AB lead are placed on the upper 1/4th point along a straight line between the wither...