Electrocardiography (ECG) in horses is a diagnostic tool used to assess the electrical activity of the heart. It involves recording the electrical impulses that govern heartbeats, providing insights into cardiac function and rhythm. This non-invasive method is useful for identifying arrhythmias, conduction disturbances, and other cardiac abnormalities in equine patients. Electrocardiography can be performed at rest or during exercise to evaluate cardiac performance under different physiological conditions. This page compiles peer-reviewed research studies and scholarly articles that explore the methodology, interpretation, and clinical applications of electrocardiography in equine health.
Buhl R, Hesselkilde EM, Carstensen H, Hopster-Iversen C, van Loon G, Decloedt A, Van Steenkiste G, Marr CM, Reef VB, Schwarzwald CC, Mitchell KJ....The recurrence rate of atrial fibrillation (AF) in horses after cardioversion to sinus rhythm (SR) is relatively high. Atrial fibrillatory rate (AFR) derived from surface ECG is considered a biomarker for electrical remodelling and could potentially be used for the prediction of successful AF cardioversion and AF recurrence. Objective: Evaluate if AFR was associated with successful treatment and could predict AF recurrence in horses. Methods: Retrospective multicentre study. Methods: Electrocardiograms (ECG) from horses with persistent AF admitted for cardioversion with either medical treatmen...
Nath LC, Forbes G, Elliott AD, Tomren V, Ryan A, Franklin SH.AliveCor is a smartphone electrocardiography device (iECG) providing automated heart rate (HR) and rhythm determination. Atrial fibrillation (AF) in horses often is paroxysmal and rapid ECG acquisition is needed for diagnostic confirmation. iECGs were collected post-race from 15 horses with AF and 64 horses in sinus rhythm (SR). Results of manual assessment were compared to 3 commercial algorithms for HR and rhythm. Agreement between manually derived HR (HRM ) and HR derived by the AliveECG Vet (HRVET ) and Kardia version-1 (KV1 HR) and Kardia advanced (KADV HR) algorithms was quantified by th...
The incidence of significant arrhythmias in sport horses and knowledge about their exact influence on athletic performance need to be clarified. The aims of the present study are to report the prevalence of cardiac arrhythmias during maximal treadmill exercise in poorly performing Standardbreds, and to investigate the possible relationship of demographic, cardiac and performance indices on premature complexes (PCs). Electrocardiographic Holter recordings before, during and after treadmill exercise testing of 158 poorly performing Standardbreds were analyzed retrospectively. Fifty horses did no...
Vitale V, Vezzosi T, Tognetti R, Fraschetti C, Sgorbini M.Recently, the use of smartphone ECG devices has been reported in humans and animals. Nevertheless, as the electrodes of these devices are inseparable, they can create only a precordial reading in veterinary species. Thus, although the smartphone ECG devices are considered valuable as a screening tool for the detection of some common arrhythmias, they are not always a reliable method for the measurement of the duration of the electrical deflections. The objectives of this study were to evaluate the feasibility of a novel smartphone ECG device, to report the readings obtained recorded simultaneo...
Pedler C, Nath L, Agne GF, Hebart M, Franklin S.Atrial fibrillation (AF) is the most common performance-limiting arrhythmia of racehorses. A genetic contribution has been suggested in Standardbred racehorses but has not been investigated in Thoroughbreds. The objective of this study was to determine the heritability of AF in Thoroughbred racehorses. Methods: Horses racing between 2007 and 2019 in Hong Kong and Australia that had AF detected postrace via auscultation (n = 463 cases) were compared with five randomly selected racing contemporaries (n = 2,315 controls). The ASReml-R programme was used to fit an animal model to the AF data t...
Sedlinská M, Kabeš R, Novák M, Kološ F, Melková P.A five-month-old African jenny was presented with a history of exercise intolerance and syncopal episodes. Severe bradycardic arrhythmia due to a high-grade second-degree atrioventricular (AV) block with progression to complete AV block was diagnosed. The jenny underwent a transvenous single-chamber pacemaker implantation. The implantation procedure was performed in a lateral recumbency and the ventricular lead was inserted through the jugular vein. Positioning of the lead was guided by echocardiography. The pacemaker was programmed to VVI mode with a minimal ventricular rate of 40 pulses per ...
Trachsel DS, Calloe K, J Rgensen E, Lunddahl CS, Pedersen PJ, Kanters JRK, Klaerke DA, Buhl R.To determine whether administration of trimethoprim-sulfadiazine (TMS), detomidine (DET), or TMS plus DET would be associated with changes in ECG repolarization parameters in horses. Methods: 9 healthy adult horses. Methods: Each horse received 4 treatments in a blinded, randomized, crossover study design as follows: TMS, 16 to 24 mg/kg, IV; DET, 0.015 to 0.02 mg/kg, IV; TMS plus DET; and saline (0.9% NaCl) solution. Surface ECG traces were obtained over 24 hours, and repolarization parameters were measured at predefined time points after each treatment and compared with a 2-way ANOVA for repe...
Li N, Yu J, Yang F, Shao Y, Wu S, Liu B, Li M, Wang T, Li J, Zeng S.The aim of this study was to evaluate the effects of L-proline on the extender quality of frozen and post-thawed jackass semen. Jackass (n = 6) semen samples were collected and cryopreserved in gradient concentrations (0-80 mM) of L-proline in extenders; post-thawed semen samples were cultured in L-proline medium for 10 hours at 37°C. For cryopreservation experiment I, the motile parameters, mitochondrial membrane potential (MMP), and plasma membrane, acrosome, and chromatin structure integrities of post-thawed semen were assessed. For culture experiment II, additional ROS contents were ana...
Van Steenkiste G, Carlson J, Decloedt A, Vera L, Buhl R, Platonov PG, van Loon G.To compare the atrial fibrillatory rate (AFR) derived from a local right atrial intracardiac recording (RA-FR) and from a single-lead surface electrocardiogram (ECG) during atrial fibrillation (AF) and to evaluate the correlation with transvenous electrical cardioversion (TVEC) threshold (in Joules), number of shocks and cardioversion success rate in horses. Methods: ECGs and clinical records of horses with AF treated by TVEC. Horses were included if a simultaneous recording of the right atrial intracardiac electrogram and a modified base-apex ECG were available. Methods: Clinical records of h...
Keen JA, O'Connor SA.Short-term electrocardiogram (ECG) examinations of horses may not detect paroxysmal arrhythmias. Twenty-four hour Holter equipment can be unwieldy and inconvenient for long-term use. This study evaluated a novel long-term ECG patch recorder, the Carnation Ambulatory Monitor (CAM) in horses, determining ideal placement, practicality, durability and performance. Methods: Twenty-one adult mixed-breed horses. Methods: Prospective observational study. Three horses had ECG patches fitted at selected sites (phase 1); the two most promising sites were used for further wear testing (phase 2) and the b...
Decloedt A, Van Steenkiste G, Vera L, Buhl R, van Loon G.Atrial fibrillation (AF) is suspected by an irregularly irregular rhythm during auscultation at rest and should be confirmed by electrocardiography. Heart rate monitoring is potentially interesting for AF detection by horse owners, based on the disproportionally high heart rate during exercise or increased heart rate variability. Echocardiography and laboratory analysis are useful to identify underlying cardiac disease. Horses with severe cardiac disease should not undergo cardioversion due to the risk of recurrence. Cardioversion is recommended especially in horses performing high intensity e...
Alberti E, Stucchi L, Pesce V, Stancari G, Ferro E, Ferrucci F, Zucca E.Due to compactness and cheapness, smartphone ECG (sECG) could be very useful to equine practitioners. However, previous studies have evaluated the accuracy of sECG in hospitalised horses only. Different conditions in the field could influence the accuracy of the device. The aim of this study is to compare the accuracy of sECG in field and in hospital conditions. Methods: This is a prospective study. Paired standard base-apex ECG (stECG) and sECG were recorded in hospitalised horses and in subjects examined in field conditions. ECGs were analysed for heart rate and rhythm, presence/type of arrh...
Hesselkilde EM, Isaksen JL, Petersen BV, Carstensen H, Jespersen T, Pehrson S, Kanters JK, Buhl R.In equine medicine, 12-lead electrocardiograms (ECGs) rarely are used, which may in part be a result of shortcomings in the existing guidelines for obtaining 12-lead ECGs in horses. The guidelines recommend placing the limb leads on the extremities, which is inappropriate because the ventricular mean electrical axis is then perpendicular to the limb leads, leading to large variations in ECG configuration even among healthy horses. From an electrophysiological point of view, the leads instead should be parallel to the electrical axis to minimize variability. Objective: Develop an improved metho...
Mitchell KJ, Schwarzwald CC.Heart rate variability (HRV) analysis has been performed on ECG-derived data sets for more than 170 years but is currently undergoing a rapid evolution, thanks to the expansion of the human and veterinary medical technology sector. Traditional HRV analysis was initially performed to identify changes in vago-sympathetic balance, while the most recent focus has expanded to include the use of complex computer algorithms, neural networks and machine learning technology to identify cardiac arrhythmias, particularly atrial fibrillation (AF). Some of these techniques have recently been translated for...
Massie SL, Bezugley RJ, McDonald KJ, Leguillette R.The prevalence and severity of cardiac arrhythmias in healthy racehorses undergoing competition is not well defined. The aim was to characterize arrhythmias in Thoroughbreds participating in official Chuckwagon races and to determine normal beat-to-beat (R-R) variability during supramaximal exercise. Electrocardiograph (ECG) recordings were obtained during pre-race, race, and active-recovery from 82 clinically healthy Thoroughbreds. ECG recordings were analyzed for arrhythmias and mean percent R-R deviation. Plasma lactate and high-sensitivity troponin (hs-cTnT) were also measured. Fifty-two E...
Buhl R, Nissen SD, Winther MLK, Poulsen SK, Hopster-Iversen C, Jespersen T, Sanders P, Carstensen H, Hesselkilde EM.Limited information is available on paroxysmal atrial fibrillation (PAF) in the horse. Indeed, undiagnosed PAF could result in poor performance. Due to the intermittent occurrence, PAF is difficult to diagnose. However, implanting a small ECG device (implantable loop recorder, ILR) subcutaneously, allows the continuous and automatic detection of PAF. Objective: The aim was to investigate the potential of ILRs as a tool for diagnosing PAF in horses with poor performance. Methods: Prospective field study. Methods: Twelve racing Standardbred trotters with intermittent reduced performance (mean ag...
Huang YH, Alexeenko V, Tse G, Huang CL, Marr CM, Jeevaratnam K.Atrial fibrillation is the most frequent arrhythmia in both equine and human athletes. Currently, this condition is diagnosed via electrocardiogram (ECG) monitoring which lacks sensitivity in about half of cases when it presents in paroxysmal form. We investigated whether the arrhythmogenic substrate present between the episodes of paroxysmal atrial fibrillation (PAF) can be detected using restitution analysis of normal sinus-rhythm ECGs. In this work, ECG recordings were obtained during routine clinical work from control and horses with PAF. The extracted QT, TQ, and RR intervals were used fo...
Marr CM, Franklin S, Garrod G, Wylie C, Smith L, Dukes-McEwan J, Bright J, Allen K.Exercise-associated cardiac rhythm disturbances are common, but there is a lack of evidence-based criteria on which to distinguish clinically relevant rhythm disturbances from those that are not. Objective: To describe and characterise rhythm disturbances during clinical exercise testing; to explore potential risk factors for these rhythm disturbances and to determine whether they influenced future racing. Methods: Retrospective cohort using a convenience sample. Methods: Medical records were reviewed from two clinical services to identify horses with poor performance and/or respiratory noise ...
Corradini I, Fernández-Ruiz A, Barba M, Engel-Manchado J.Comparisons between smartphone ECG (SpECG) recordings obtained from the right and left sides of the thorax have not been reported in animals. Objective: To evaluate the screening potential of a SpECG obtained from both sides of the thorax and to compare the degree of agreement between the SpECG and a reference ECG (rECG) for measurement of the duration of baseline electrical deflections recorded over both sides of the thorax. Methods: Fifty horses admitted to the equine hospital, university-owned horses, and horses from an endurance riding facility. Methods: Prospective observational study. Si...
There are several bioengineering solutions aimed at improving human health and welfare. Smart electrodes based on textile substrates have met the growing demand for comfort, reliability, and robustness when acquiring physiological signals. Objective: Given the importance of good quality electrocardiograms (ECG) in equine sports medicine, this study focuses on the validation of smart textile electrodes to acquire ECG signals in horses during treadmill exercise. Methods: The performance of the smart textile electrodes is compared with standard silver/silver chloride (Ag/AgCl) electrodes in terms...
Drábková Z, Amory H, Kabeš R, Melková P, van Loon G.A partial atrioventricular septal defect, represented as a large ostium primum atrial septal defect and common (bridging) atrioventricular valve leaflets with cleft septal leaflet of the mitral valve, was diagnosed incidentally in a nine-year-old warmblood gelding used for show jumping. Initial examination findings and a three-year follow-up are documented in this report. The horse was first presented for the evaluation of chronic coughing. A left-sided, grade 4/6 holosystolic (band-shaped) murmur was identified along with a similar right-sided, grade 3/6 heart murmur. Echocardiography reveale...
Cherdchutham W, Koomgun K, Singtoniwet S, Wongsutthawart N, Nontakanun N, Wanmad W, Petchdee S.The objective of this study was to assess a new lead system method to improve electrocardiographic measurement in horses. Methods: Twenty-two horses with an average age of 8.8±0.8 years were enrolled in this study. Horses were divided into two groups, consisting of a control group (n=11) and athlete group (n=11). Electrocardiography (ECG) and echocardiography were performed to provide information on the structure and function of the heart. Two lead systems, base apex and modified precordial leads, were used for the electrocardiogram to assess the cardiac electrophysiological functions. Result...
Buhl R, Hesselkilde EM, Carstensen H, Fenner MF, Jespersen T, Tfelt-Hansen J, Michael Sattler S.Cardiac arrhythmias in horses are diagnosed by auscultation or electrocardiogram (ECG), which results in a low sensitivity for detecting arrhythmias that occur sporadically. Implantable loop recorders (ILRs) are small ECG devices placed subcutaneously, to automatically detect arrhythmias in human patients. Objective: To test ILRs ability to detect atrial fibrillation (AF) in horses. Furthermore, we hypothesised that anatomical location of the implant site might influence signal quality. Signal quality was evaluated both during exercise and over time. Methods: Experimental study. Methods: In fi...
Restan AZ, Camacho AA, Cerqueira JA, Zacché E, Kirnew MD, Loureiro BA, Silva SB, Moranza HG, Ferraz GC.The dogs' responses to training exercise are seldom monitored using physiological variables, and cardiac autonomic regulation (CAR) is a relevant determinant of endurance-training adaptation. There are studies in the literature establishing that regular exercise could interfere with CAR in dogs, measured by heart rate and vagal-derived indexes of heart-rate-variability (HRV). However, few studies were found using a prescribed training program based on the lactate threshold (LT) to determine HRV by a 24-h Holter analysis. The purpose of this study was to test whether an endurance-training progr...
Welch-Huston B, Durward-Akhurst S, Norton E, Ellingson L, Rendahl A, McCue M.Cardiac arrhythmias are commonly auscultated during routine physical examinations in horses and determining the underlying electrical abnormality using an ECG is important. The most commonly used device is a three-lead base apex system (Televet), however few practitioners carry this for routine visits. With recognition of the utility of smartphone-based ECGs in humans, dogs and ruminants, the AliveCor single-lead bipolar smartphone-based ECG has gained popularity. The objective of this study was to determine if AliveCor and Televet ECG measurements were comparable in healthy horses using multi...
Recchi L, Alvariza S, Benech A, Ruiz N, José Estradé M, Suarez G, Crosignani N.The purpose of this study was to evaluate the pharmacokinetics of oral amitriptyline in horses. Oral amitriptyline (1 mg/kg) was administered to six horses. Blood samples were collected from jugular and lateral thoracic vein at predetermined times from 0 to 24 hr after administration. Plasma concentrations were determined by high-performance liquid chromatography and analyzed using noncompartmental methods. Pharmacodynamic parameters including heart rate, respiration rate, and intestinal motility were evaluated, and electrocardiographic examinations were performed in all subjects. The mean m...
Alexeenko V, Fraser JA, Bowen M, Huang CL, Marr CM, Jeevaratnam K.Equine athletes have a pattern of exercise which is analogous to human athletes and the cardiovascular risks in both species are similar. Both species have a propensity for atrial fibrillation (AF), which is challenging to detect by ECG analysis when in paroxysmal form. We hypothesised that the proarrhythmic background present between fibrillation episodes in paroxysmal AF (PAF) might be detectable by complexity analysis of apparently normal sinus-rhythm ECGs. In this retrospective study ECG recordings were obtained during routine clinical work from 82 healthy horses and from 10 horses with a ...
Van Steenkiste G, L V, Decloedt A, Schauvliege S, Boussy T, van Loon G.Understanding the depolarisation pattern of the equine heart under normal physiologic conditions, and its relationship to the surface electrocardiogram (ECG), is of uppermost importance before any further research can be done about the pathophysiology of complex arrhythmias. In the present study, a 3D electro-anatomical mapping system was used to evaluate the qualitative and quantitative depolarisation patterns and correlation to the surface ECG of both the atrial and ventricular endocardium in seven healthy horses in sinus rhythm under general anaesthesia. Bipolar activation maps of the endoc...
McGuirk SM, Muir WW.Cardiac arrhythmias are probably more common in horses than in any other domestic animal species. The most frequent clinical complaint associated with cardiac arrhythmias is exercise intolerance. Physical examination is characterized by auscultation abnormalities such as fast or slow heart rate, irregular rhythm, extra sounds, long pauses, or abnormal heart sounds. The electrocardiogram is used to make a definitive diagnosis of the dysrhythmia. Other laboratory and cardiac function tests are employed to determine the etiology and to assess the significance of the arrhythmia. Antiarrhythmic the...
Ayala I, Gutierrez-Panizo C, Benedito JL, Prieto F, Montes A.The aim of this work was to record the modifications of the form and amplitude of the electrocardiographic tracings during growth using the Dubois system and to study its sensibility to these physiological changes. This work was carried out on 179 healthy, young and adult Spanish-bred horses (98 females and 81 males). One electrocardiogram (ECG) was obtained from each horse using the Dubois leads system. The bifid shape deflection of the P wave was generally more frequent than the simple one in animals at 4 months of age or older. Amplitudes of the P2 component and of the simple positive wave ...
Trachsel DS, Bitschnau C, Waldern N, Weishaupt MA, Schwarzwald CC.Frequent supraventricular or ventricular arrhythmias during and after exercise are considered pathological in horses. Prevalence of arrhythmias seen in apparently healthy horses is still a matter of debate and may depend on breed, athletic condition and exercise intensity. Objective: To determine intra- and interobserver agreement for detection of arrhythmias at rest, during and after exercise using a telemetric electrocardiography device. Methods: The electrocardiogram (ECG) recordings of 10 healthy Warmblood horses (5 of which had an intracardiac catheter in place) undergoing a standardised ...
Welch-Huston B, Durward-Akhurst S, Norton E, Ellingson L, Rendahl A, McCue M.Cardiac arrhythmias are commonly auscultated during routine physical examinations in horses and determining the underlying electrical abnormality using an ECG is important. The most commonly used device is a three-lead base apex system (Televet), however few practitioners carry this for routine visits. With recognition of the utility of smartphone-based ECGs in humans, dogs and ruminants, the AliveCor single-lead bipolar smartphone-based ECG has gained popularity. The objective of this study was to determine if AliveCor and Televet ECG measurements were comparable in healthy horses using multi...
Meyer GA, Lin HC, Hanson RR, Hayes TL.This study aimed to identify blood serum lidocaine concentrations in the horse which resulted in clinical signs of intoxication, and to document the effects of toxic levels on the cardiovascular and cardiopulmonary systems. Nineteen clinically normal mature horses of mixed breed, age and sex were observed. Lidocaine administration was initiated in each subject with an i.v. loading dose of 1.5 mg/kg bwt and followed by continuous infusion of 0.3 mg/kg bwt/min until clinical signs of intoxication were observed. Intoxication was defined as the development of skeletal muscle tremors. Prior to admi...
Holmes JR, Alps BJ.Theoretical consideration has been given in two horses to the properties of the electric field created by the equine heart acting as a simple electric generator. The principles of the vectorial theory have been applied to test the validity of application of the dipole concept. The cardiac electric forces, althrough complex in the immediate region of the heart, appear at the body surface in a similar form to those arising from a relatively immobile, single equivalent dipole. The potential value of the technique of vectorcardiography in cardiological investigations is briefly discussed.
Nostell K, Bröjer J, Höglund K, Edner A, Häggström J.The aim of this study was to determine whether experimentally-induced endotoxaemia induced elevations in plasma cardiac troponin I (cTnI) concentrations in horses and how this might affect the incidence of cardiac arrhythmias. Eight Standardbred horses received an intravenous continuous rate infusion of endotoxin (total dose 500 ng/kg) for 6 h while being monitored using electrocardiography (ECG). Blood samples were collected before the start of the endotoxin infusion, every 60 min during the infusion, then 1, 2, 3, 8, 10 and 24 h post-infusion, and analysed for cTnI concentrations. One horse ...
There are several bioengineering solutions aimed at improving human health and welfare. Smart electrodes based on textile substrates have met the growing demand for comfort, reliability, and robustness when acquiring physiological signals. Objective: Given the importance of good quality electrocardiograms (ECG) in equine sports medicine, this study focuses on the validation of smart textile electrodes to acquire ECG signals in horses during treadmill exercise. Methods: The performance of the smart textile electrodes is compared with standard silver/silver chloride (Ag/AgCl) electrodes in terms...
Hilwig RW.Electrocardiograms were obtained from normal horses and from horses with cardiac or other organic disease that affected the cardiac rhythm. Tracings were obtained from a base-apex bipolar monitor lead, with the negative electrode attached to the skin in the right jugular furrow and the positive electrode attached to the skin on the ventral medline, beneath the apex of the heart. Each arrhythmia was discussed relative to importance and probable cause.
The effects of cryopreservation on the acrosomal status of equine spermatozoa were investigated. Ejaculates (n=10) from six stallions were processed fresh, after cooled storage at 4-6 degrees C for 24 h in either a milk-based or lactose-EDTA freezing extender and after freeze-thawing in lactose-EDTA extender in liquid nitrogen at either 5 x 10(7) or 2 x 10(8) spermatozoa ml(-1). All samples were incubated in TALP-TEST for 2 h at 39 degrees C in 5% CO2. Subsamples were challenged with calcium ionophore A23187 for 10 min. The acrosomal status of the spermatozoa was evaluated by staining the sper...
Escudero A, González JR, Benedito JL, Prieto FR, Ayala I.Limited information exists regarding electrocardiographic parameters in clinically healthy donkeys. The study was carried out in 75 healthy adult animals (40 females and 35 males) using the Einthoven standard II and base-apex leads. The P wave showed usually a bifid shape deflection. The QRS complex of the donkeys appeared in several forms: QR and R were the most frequent in limb lead II, and QS and QR in the base-apex lead. Most T waves presented a simple negative configuration in lead II and biphasic shape in the base-apex one. Mean heart rate value was 52 beats per minute. The direction of ...
Evans DL, Rose RJ.The measurement of heart rate during exercise in the horse has been recommended as a means of prescribing work effort, monitoring the changes in aerobic capacity during training and as part of the clinical examination of the performance horse. The accuracy of four heart rate meters (PEH 100, PU 10, HR 14 and HRM-7) was assessed by comparison with heart rate determined by simultaneous telemetry electrocardiography (ECG) using a rapid incremental exercise test on a treadmill. Heart rate displayed by all four meters showed significant correlations with the ECG heart rate, but only two meters (PEH...
Morgan RA, Raftery AG, Cripps P, Senior JM, McGowan CM.The prevalence and nature of arrhythmias in horses following general anaesthesia and surgery is poorly documented. It has been proposed that horses undergoing emergency surgery for gastrointestinal disorders may be at particular risk of developing arrhythmias. Our primary objective was to determine the prevalence and nature of arrhythmias in horses following anaesthesia in a clinical setting and to establish if there was a difference in the prevalence of arrhythmias between horses with and without gastrointestinal disease undergoing surgery. Our secondary objective was to assess selected avail...
Decloedt A, Van Steenkiste G, Vera L, Buhl R, van Loon G.Atrial fibrillation (AF) is suspected by an irregularly irregular rhythm during auscultation at rest and should be confirmed by electrocardiography. Heart rate monitoring is potentially interesting for AF detection by horse owners, based on the disproportionally high heart rate during exercise or increased heart rate variability. Echocardiography and laboratory analysis are useful to identify underlying cardiac disease. Horses with severe cardiac disease should not undergo cardioversion due to the risk of recurrence. Cardioversion is recommended especially in horses performing high intensity e...
Durando MM.Horses have a high prevalence of resting arrhythmias, cardiac murmurs, and valvular regurgitation, and training can increase the prevalence. This makes it challenging for equine veterinarians who are asked to evaluate horses for poor performance to determine the clinical relevance of some findings. In addition, cardiac disease has the potential to cause collapse or sudden death, putting both the horse and rider at risk. Further diagnostics, such as echocardiograms and resting and exercising ECGs can help to sort out the impact of an abnormality found on resting physical examination. However un...
Gelzer AR, Moïse NS, Vaidya D, Wagner KA, Jalife J.Atrial fibrillation (AF) is common in healthy horses. We studied the temporal organization of AF to test the hypothesis that the arrhythmia is governed by a high degree of periodicity and therefore is not random in the horse. Further, we surmised that concealed conduction of AF impulses in the AV node results in an inverse relationship between AF frequency and ventricular frequency. Results: Fast Fourier transform (FFT) analysis of atrial activity was done on signal-averaged ECGs (n = 11) and atrial electrograms (n = 3) of horses with AF at control (C), after quinidine sulfate (22 mg/kg by mou...
Reef VB, Clark ES, Oliver JA, Donawick WJ.A permanent, transvenous, atrioventricular, sequential pacing system was implanted successfully in a 7-year-old Quarter Horse gelding with complete heart block. The transvenous atrial and ventricular electrodes were placed in their respective positions in the heart, using real-time, 2-dimensional echocardiography. The horse was able to return successfully to competition as a show horse.
Buntenkötter S, Deegen E.Cardioversion through varying quinidine sulphate treatments was achieved in 3 riding horses with auricular fibrillation. The horses were subjected to continual telemetric ECG registration before and after reversion in a uniform exercise-tolerance-test. A comparison of the heart rate curves showed a strong decline of the heart beat frequency during the exercise phase after synchronisation. The decrease in heart rate during exercise was greater than 30% in all 3 patients. Anti-arrhythmic treatment is, therefore, recommended for horses with auricular fibrillation and without concurrent heart dise...
Lombard CW, Evans M, Martin L, Tehrani J.Twelve newborn pony foals underwent cardiovascular examinations (auscultation, arterial blood pressure measurements, electrocardiograms and M-mode echocardiograms) on their first day of life and then on Days 7, 14, 21, 30, 60 and 90. An age dependent, statistically significant, rapid increase of the arterial blood pressure in the first month was documented together with a slower decrease of the resting heart rate after two and three months of life. Innocent soft systolic murmurs were audible over the left heart base in a large number of the foals. The electrocardiograms showed age dependent in...
Bayly WM, Reed SM, Leathers CW, Brown CM, Traub JL, Paradis MR, Palmer GH.Five Arabian or half-Arabian foals with suspected multiple cardiac anomalies were examined. Various combinations of clinical examination, electrocardiography, angiocardiography, cardiac catheterization, blood gas analysis, radiography, and echocardiography resulted in clinical data that allowed accurate antemortem diagnoses to be made. In 4 cases, the clinical diagnosis was substantiated by postmortem findings. The confirmed diagnoses were: pseudotruncus arteriosus, a combination of patent ductus arteriosus, pulmonic stenosis, and tricuspid stenosis, pentalogy of Fallot, and tricuspid atresia....
Norman SE, Eager RA, Waran NK, Jeffery L, Schroter RC, Marlin DJ.Analysis of heart rate variability (HRV) is a non-invasive technique useful for investigating autonomic function in both humans and animals. It has been used for research into both behaviour and physiology. Commercial systems for human HRV analysis are expensive and may not have sufficient flexibility for appropriate analysis in animals. Some heart rate monitors have the facility to provide inter-beat interval (IBI), but verification following collection is not possible as only IBIs are recorded, and not the raw electrocardiogram (ECG) signal. Computer-based data acquisition and analysis syste...
Lorello O, Ramseyer A, Burger D, Gerber V, Navas de Solis C.The objectives of this study were to describe the changes in clinical cardiovascular examination variables over a competition season in groups of competitive eventing and endurance horses and to compare these findings to non-competitive controls of the same breeds. Methods: This study included two eventing horses, 11 endurance horses, and 13 eventing and seven endurance control breed-matched horses. Methods: Cardiovascular examinations were performed before starting the competition season, in the middle and at the peak/end of the competition season. Examinations included auscultation of the he...
Squires EL, McCue PM.Embryo recovery from single ovulating mares is approximately 50 per cent per estrous cycle. Superovulation could be used to increase embryo recovery and provide extra embryos for embryo freezing. This review addresses some historical approaches to superovulation, as well as examines factors that affect the response of mares to equine FSH. eCG, GnRH and inhibin vaccines have been of limited success in stimulating multiple ovulation. Numerous studies have shown that injection of equine pituitary extract (EPE) will result in three to four ovulations per estrous cycle and two embryos. A purified, ...
Kraus MS, Rishniw M, Divers TJ, Reef VB, Gelzer AR.Evaluate accuracy and utility of a smartphone-based ECG device compared to a standard base-apex lead ECG in horses. Methods: ECGs were acquired prospectively from 28 client-owned horses at 2 equine referral hospitals. Twenty-five pairs of 30-s ECG recordings were acquired simultaneously from 23 horses with a smartphone ECG device (a bi-polar single lead recorder coupled to a smartphone with an ECG application) and with a standard base-apex lead ECG; 2 horses provided two pairs of simultaneously acquired ECGs. In one horse, the ECGs pairs were recorded immediately sequentially. An additional 7 ...
Robertson JT, Muir WW, Sams R.The cardiopulmonary and behavioral effects of butorphanol were evaluated in pain-free adult horses. Butorphanol tartrate was administered IV in doses of 0.1, 0.2, and 0.4 mg/kg to the same horses on 3 separate occasions. There were no significant (P less than 0.05) changes in heart rate, mean and diastolic arterial pressure, mean and diastolic pulmonary arterial blood pressure, or cardiac output recorded in the horses given these doses. Systolic arterial blood pressure was significantly (P less than 0.05) increased in only the horses given the 0.2 mg/kg dose. Significant (P greater than 0.05) ...
Pérez-Marín CC, Requena FD, Arando A, Ortiz-Villalón S, Requena F, Agüera EI.There has been a lack of research into equine sperm vitrification to date, but studies of other species suggest it may have significant potential. To evaluate the impact of various cryoprotectant agents (CPA) and vitrification on equine sperm quality, a controlled study was carried out. A total of 12 ejaculates were subjected to exposure to CPA and vitrification. Sperm was diluted in a range of CPA: fresh, control (BSA), sucrose (0.15M, 0.3M and 0.5M), trehalose (0.15M, 0.3M and 0.5M) and the combination of sucrose and trehalose (M1: 0.15M sucrose+0.5M trehalose; M2: 0.5M sucrose+0.15M trehalo...
Frye MA, Selders CG, Mama KR, Wagner AE, Bright JM.Rectilinear biphasic cardioversion was used in 2 horses with idiopathic sustained atrial fibrillation; 1 horse converted to sustained sinus rhythm. Variables that potentially affected outcome of the electrical cardioversion procedures in these horses included duration of arrhythmia, placement of cardioverter pads and paddles, serum electrolyte concentrations, and treatment with quinidine. Serum cardiac troponin I concentration, measured to determine whether the myocardium was damaged from the electrical shocks, was within the reference range in both horses after the procedure. Biphasic electri...