Analyze Diet

Topic:Imaging Techniques

Imaging techniques in horses encompass a range of diagnostic tools used to visualize the internal structures and systems of equine patients. These techniques assist in the diagnosis, monitoring, and treatment planning of various conditions affecting horses. Common imaging modalities include radiography (X-rays), ultrasonography, magnetic resonance imaging (MRI), and computed tomography (CT). Each technique offers unique advantages in terms of resolution, depth of penetration, and the type of tissues that can be examined. For instance, radiography is frequently used for assessing bone structures, while ultrasonography is often employed for soft tissue evaluation. MRI and CT provide detailed cross-sectional images, aiding in the assessment of complex anatomical regions. This page compiles peer-reviewed research studies and scholarly articles that explore the application, advancements, and comparative efficacy of imaging techniques in equine veterinary medicine.
Magic angle magnetic resonance imaging of diode laser induced and naturally occurring lesions in equine tendons. Spriet M, Murphy B, Vallance SA, Vidal MA, Whitcomb MB, Wisner ER.Magic angle magnetic resonance (MR) imaging consists of imaging tendons at 55° to the magnetic field. In people, magic angle MR imaging is valuable for detection of chronic tendon lesions and allows calculation of tendon T1 values. Increased T1 values occur in people with chronic tendinopathy. The T1 values of normal equine tendons have been reported but there are no available data for abnormal equine tendons. Twelve limbs were studied. Two limbs had diode laser tendon lesions induced postmortem, four limbs had diode laser tendon lesions induced in vivo and six limbs had naturally occurring t...
Comparison of radiography, nuclear scintigraphy, and magnetic resonance imaging for detection of specific conditions of the distal tarsal bones of horses: 20 cases (2006-2010).
Journal of the American Veterinary Medical Association    April 21, 2012   Volume 240, Issue 9 1109-1114 doi: 10.2460/javma.240.9.1109
Daniel AJ, Judy CE, Rick MC, Saveraid TC, Herthel DJ.To describe pathological findings identified with MRI in the distal tarsal bones of horses with unilateral hind limb lameness attributable to tarsal pain and to compare the usefulness of MRI with that of radiography and nuclear scintigraphy in evaluation of this region. Methods: Retrospective case series. Methods: 20 lame horses. Methods: In all horses, MRI, radiography (4 standard projections), and nuclear scintigraphy of the tarsus had been performed. Horses were excluded if the results of all 3 imaging modalities were not available or if lameness was detected in more than 1 limb. Pathologic...
Comparison of ultrasound and optical coherence tomography techniques for evaluation of integrity of spontaneously repaired horse cartilage.
Journal of medical engineering & technology    March 24, 2012   Volume 36, Issue 3 185-192 doi: 10.3109/03091902.2012.663054
Virén T, Huang YP, Saarakkala S, Pulkkinen H, Tiitu V, Linjama A, Kiviranta I, Lammi MJ, Brünott A, Brommer H, Van Weeren R, Brama PA, Zheng YP....The aim of this study was to compare sensitivity of ultrasound and optical coherence tomography (OCT) techniques for the evaluation of the integrity of spontaneously repaired horse cartilage. Articular surfaces of horse intercarpal joints, featuring both intact tissue and spontaneously healed chondral or osteochondral defects, were imaged ex vivo with arthroscopic ultrasound and laboratory OCT devices. Quantitative ultrasound (integrated reflection coefficient (IRC), apparent integrated backscattering coefficient (AIB) and ultrasound roughness index (URI)) and optical parameters (optical refle...
Standing CT and clinical progression of equine cholesterol granulomata.
The Veterinary record    March 1, 2012   Volume 170, Issue 11 289 doi: 10.1136/vr.100537
Finding E, Fletcher N, Avella C, Naylor RJ, Volk HA, Weller R, Dunkel B, Piercy RJ.No abstract available
Accuracy and precision of computer-assisted analysis of bone density via conventional and digital radiography in relation to dual-energy x-ray absorptiometry.
American journal of veterinary research    March 1, 2012   Volume 73, Issue 3 381-384 doi: 10.2460/ajvr.73.3.381
Vaccaro C, Busetto R, Bernardini D, Anselmi C, Zotti A.To evaluate the precision and accuracy of assessing bone mineral density (BMD) by use of mean gray value (MGV) on digitalized and digital images of conventional and digital radiographs, respectively, of ex vivo bovine and equine bone specimens in relation to the gold-standard technique of dual-energy x-ray absorptiometry (DEXA). Methods: Left and right metatarsal bones from 11 beef cattle and right femurs from 2 horses. Methods: Bovine specimens were imaged by use of conventional radiography, whereas equine specimens were imaged by use of computed radiography (digital radiography). Each specim...
Differences in the morphology of distal border synovial invaginations of the distal sesamoid bone in the horse as evaluated by computed tomography compared with radiography.
Equine veterinary journal    February 15, 2012   Volume 44, Issue 6 679-683 doi: 10.1111/j.2042-3306.2012.00547.x
Claerhoudt S, Bergman HJ, Van Der Veen H, Duchateau L, Raes EV, Saunders JH.Distal border synovial invaginations of the distal sesamoid bone are radiographically assessed during the selection process of horses admitted as breeding stallions or in purchase examinations. Nowadays, many moderately or some deeply penetrating proximally enlarged synovial invaginations are considered as moderate or severe radiographic findings. Objective: To measure the difference between and agreement of the morphology of distal border synovial invaginations on radiography vs. computed tomography (CT). It was hypothesised that the morphology of distal border synovial invaginations would be...
Comparison of ultrasound-guided vs. ‘blind’ techniques for intra-synovial injections of the shoulder area in horses: scapulohumeral joint, bicipital and infraspinatus bursae.
Equine veterinary journal    February 15, 2012   Volume 44, Issue 6 674-678 doi: 10.1111/j.2042-3306.2011.00540.x
Schneeweiss W, Puggioni A, David F.Diagnosis and treatment of pathologies involving synovial structures in the shoulder region are technically difficult. Ultrasound-guided (UG) injection techniques have been shown to be highly accurate, safe and reliable for various structures in human and equine patients. Objective: To develop easy-to-use and reliable UG injection techniques for the infraspinatus bursa (IB), bicipital bursa (BB) and scapulohumeral joint (SHJ) and to compare them with conventional 'blind' methods. Methods: Eight pairs of equine shoulders were positioned on a computed-tomography (CT) table with left and right sh...
Characterization of the origin and body of the normal equine rear suspensory ligament using ultrasonography, magnetic resonance imaging, and histology. Schramme M, Josson A, Linder K.The suspensory ligament is difficult to image accurately, partly because it contains ligamentous fibers, as well as noncollagenous adipose and muscle tissue in the normal horse. Our hypothesis was that magnetic resonance (MR) imaging would be more accurate than ultrasonography in identifying the size of the suspensory ligament and the presence and size of noncollagenous tissues within the ligament. Eleven horses were used for ultrasonographic and MR imaging and histologic evaluation of the rear suspensory ligament. The origin and body of the normal suspensory ligament had a heterogenous appear...
Diagnostic imaging in veterinary dental practice.
Journal of the American Veterinary Medical Association    February 9, 2012   Volume 240, Issue 4 379-381 doi: 10.2460/javma.240.4.379
Menzies RA, Lundström TS, Lewis JR, Reiter AM.No abstract available
Precision of a photogrammetric method to perform 3D wound measurements compared to standard 2D photographic techniques in the horse.
Equine veterinary journal    January 28, 2012   Volume 45, Issue 1 41-46 doi: 10.1111/j.2042-3306.2011.00538.x
Labens R, Blikslager A.Methods of 3D wound imaging in man play an important role in monitoring of healing and determination of the prognosis. Standard photographic assessments in equine wound management consist of 2D analyses, which provide little quantitative information on the wound bed. Objective: 3D imaging of equine wounds is feasible using principles of stereophotogrammetry. 3D measurements differ significantly and are more precise than results with standard 2D assessments. Methods: Repeated specialised photographic imaging of 4 clinical wounds left to heal by second intention was performed. The intraoperator ...
The influence of temperature and age on the T1 relaxation time of the equine distal limb. Adrian AM, Koene M, Roberts S, Doughty P, Bolas N, Kinns J, Brehm W, Gerlach K.The extent of fat suppression using short tau inversion recovery (STIR) imaging is variable between horses. Our aim was to determine if patient's age and/or hoof temperature have an influence on the T(1) relaxation time of bone marrow in the equine distal limb, thereby affecting the suppression of fat signal. Magnetic resonance imaging was conducted on standing horses and cadaver samples using a low-field magnet (0.27 T). The hoof temperature was measured at the lateral side of the coronary band. A modified inversion recovery fast spin-echo (IR-FSE) sequence was used to measure the signal inte...
Detection of small tendon lesions by sonoelastographic visualization of strain profile differences: initial experiences.
Skeletal radiology    January 5, 2012   Volume 41, Issue 9 1073-1079 doi: 10.1007/s00256-011-1349-2
Buck AR, Verstraete N, Li Y, Schweizer A, Snedeker JG, Buck FM.To assess the capability of a commercial sonoelastography system to detect small tendon lesions by quantitative analysis of elastogram profiles. Methods: Strips of equine digital flexor tendons were used to model small human tendons. Two tendons were examined. From each tendon, six unmodified tendon strips (controls) and six tendon strips with a central defect of the same tendons were compared. The tendon strips were placed under a physiological tensile strain of 5%. Sonoelastographic visualization of the strain profile was performed. Regions of interest (ROI) were defined left and right of th...
Three-dimensional ultrasound imaging of the equine fetus.
Theriogenology    December 20, 2011   Volume 77, Issue 7 1480-1486 doi: 10.1016/j.theriogenology.2011.10.020
Kotoyori Y, Yokoo N, Ito K, Murase H, Sato F, Korosue K, Nambo Y.The objective was to assess the optimal procedure for real-time, three-dimensional (3D) ultrasound (US) imaging for assessing the equine fetus during the first half of gestation and the possibility of using 3D US imaging of the equine fetus in clinical applications. Seventeen pregnant mares were examined by 3D US between Days 35 and 180 of gestation. Abdominal and endo-vaginal real-time 3D transducers used in human medicine were used for transrectal and transvaginal examinations, respectively. Images were recorded by both 3D stationary and real-time movies. In a comparison of four methods, tra...
Distribution of ventilation in pregnant Shetland ponies measured by Electrical Impedance Tomography.
Respiratory physiology & neurobiology    December 8, 2011   Volume 180, Issue 2-3 258-262 doi: 10.1016/j.resp.2011.11.018
Schramel J, Nagel C, Auer U, Palm F, Aurich C, Moens Y.The regional distribution of ventilation in conscious standing pregnant Shetland pony mares was investigated by Electrical Impedance Tomography (EIT). Six ponies were repeatedly examined a minimum of four weeks prior to (antepartum, AP) until three weeks after parturition (postpartum, PP). From the cross-sectional ventilation image the ventral to dorsal (V/D), left to right (L/R) ventilation distribution ratio and the relative ventilation in four horizontal regions of interest (ROI) placed symmetrically in the chest was analyzed. Antepartum V/D was 0.74 ± 0.09 on day -28 ± 3 (AP28) and decre...
Axial speed of sound is related to tendon’s nonlinear elasticity.
Journal of biomechanics    November 10, 2011   Volume 45, Issue 2 263-268 doi: 10.1016/j.jbiomech.2011.10.032
Vergari C, Ravary-Plumioën B, Evrard D, Laugier P, Mitton D, Pourcelot P, Crevier-Denoix N.Axial speed of sound (SOS) measurements have been successfully applied to noninvasively evaluate tendon load, while preliminary studies showed that this technique also has a potential clinical interest in the follow up of tendon injuries. The ultrasound propagation theory predicts that the SOS is determined by the effective stiffness, mass density and Poisson's ratio of the propagating medium. Tendon stiffness characterizes the tissue's mechanical quality, but it is often measured in quasi-static condition and for entire tendon segments, so it might not be the same as the effective stiffness w...
Anterior and posterior segment photography. An alternative approach using a dSLR camera adaptor.
Veterinary ophthalmology    October 31, 2011   Volume 15, Issue 4 280-287 doi: 10.1111/j.1463-5224.2011.00963.x
Pirie CG, Pizzirani S.  To describe a novel digital single lens reflex (dSLR) camera adaptor for anterior and posterior segment photography. Methods:   The adaptor was used to evaluate canine, feline, and equine patients presenting to Tufts Ophthalmology service. Anterior segment imaging was conducted with the adaptor mounted between a dSLR camera body (Canon 7D) and a macro lens (Canon EF-S 60mm/f2.8). Posterior segment imaging was performed with the aid of an indirect ophthalmic lens mounted in front of the macro lens. Coaxial illumination during viewing was provided by a single white light-emitting diode (LE...
Web-based documentation of clinical skills to assess the competency of veterinary students.
Journal of veterinary medical education    October 26, 2011   Volume 38, Issue 3 242-250 doi: 10.3138/jvme.38.3.242
Rush BR, Biller DS, Davis EG, Higginbotham ML, Klocke E, Miesner MD, Rankin DC.Kansas State University implemented a Web-based program to assess students' competency to perform technical skills during clinical rotations throughout the fourth year of the veterinary curriculum. The classes of 2009 and 2010 recorded a minimum number of procedures (104 and 103, respectively) from a menu of more than 220 recommended procedures. Procedures were categorized by species (small animal, equine, food animal) and disciplines (imaging, anesthesia, diagnostic medicine/necropsy). Ophthalmology was added as a fourth discipline for the class of 2010. Students recorded procedures into the ...
Understanding abdominal ultrasonography in horses: which way is up?
Compendium (Yardley, PA)    October 14, 2011   Volume 33, Issue 9 E2 
Henry Barton M.The recent introduction of more affordable and portable ultrasound equipment makes it possible to perform transabdominal ultrasonography on equine patients in the field. Clipping the hair is not always necessary: intraabdominal structures can be quickly evaluated by soaking hair with isopropyl alcohol and using a 3.0- to 3.5-MHz curvilinear transducer. The ultrasonographer must be acquainted with the location and architecture of normal intraabdominal structures and simultaneously mindful of the depth of the viewing field, the tissue interface densities, the orientation of the transducer relati...
Optimization of a Staphylococcus aureus adhesion assay for equine corneocytes.
Veterinary dermatology    October 13, 2011   Volume 23, Issue 1 57-e13 doi: 10.1111/j.1365-3164.2011.01012.x
Griffeth GC, Callori N, Rankin SC, Boston RC, Morris DO.Meticillin-resistant Staphylococcus aureus (MRSA) causes serious skin and soft-tissue infections of humans and animals. Multiple strains of MRSA have been characterized, and one in particular, designated as strain USA 500, causes infections predominantly of horses and the people who work with them. The purpose of this study was to optimize an assay which could subsequently be used to compare the relative avidity of different S. aureus strains for equine corneocytes. Corneocytes were collected from the perineal skin of 10 healthy horses onto adhesive discs. The discs were then incubated at 37°...
Movement associated reduction of spatial capacity of the equine cervical vertebral canal.
Veterinary journal (London, England : 1997)    September 14, 2011   Volume 192, Issue 3 525-528 doi: 10.1016/j.tvjl.2011.08.011
Schmidburg I, Pagger H, Zsoldos RR, Mehnen J, Peham C, Licka TF.Laterolateral radiographs of equine necks are reported to be inaccurate in determining the site of spinal cord lesions even when a myelogram is carried out. The goal of this study was to assess constrictions present in the cervical vertebral canal at any time point throughout the extremes of movement. Sixteen equine cervical vertebral columns without history of cervical disease were used. After removal of the spinal cord, the dura mater was filled with polyurethane foam and during its plastic phase the cervical vertebral column was passively moved in flexion-extension, lateral bending and 30°...
Propagation of two longitudinal waves in a cancellous bone with the closed pore boundary.
The Journal of the Acoustical Society of America    September 1, 2011   Volume 130, Issue 2 EL122-EL127 doi: 10.1121/1.3607196
Mizuno K, Nagatani Y, Yamashita K, Matsukawa M.Ultrasound propagation in cancellous bone (porous media) under the condition of closed pore boundaries was investigated. A cancellous bone and two plate-like cortical bones obtained from a racehorse were prepared. A water-immersion ultrasound technique in the MHz range and a three-dimensional elastic finite-difference time-domain (FDTD) method were used to investigate the waves. The experiments and simulations showed a clear separation of the incident longitudinal wave into fast and slow waves. The findings advance the evaluation of bones based on the two-wave phenomenon for in vivo assessment...
The value of radiographic screening for metallic particles in the equine foot and size of related artifacts on low-field MRI. Urraca del Junco CI, Shaw DJ, Weaver MP, Schwarz T.Magnetic susceptibility artifacts as a result of metal debris from shoeing are a common problem in magnetic resonance imaging of the equine foot. Our purpose was to determine the suitability of radiography as a screening tool for the presence and location of metallic particles in the equine foot and to predict the size of the resultant magnetic susceptibility artifact. Radiography had 100% sensitivity for detection of metal particles > or = 1 mm diameter. Metal particles of known diameter were placed within the hoof wall of 22 cadaver feet and scanned with a low-field strength MR imaging un...
Ultrasonographic evidence of colonic mesenteric vessels as an indicator of right dorsal displacement of the large colon in 13 horses.
Equine veterinary journal. Supplement    August 4, 2011   Issue 39 153-155 doi: 10.1111/j.2042-3306.2011.00418.x
Grenager NS, Durham MG.This report describes the use of ultrasound to diagnose right dorsal displacement of the large colon (RDDLC) in 13 horses prior to surgery. Horses had ultrasonographic examinations performed of the right lateroventral aspect of the abdomen upon admission to the hospital with a 2-5 MHz broadband curvilinear sector scanning transducer after alcohol was used to wet the hair. First, the caecal vessels were identified in the right flank and followed medially and cranially. Next, each intercostal space, from caudal to cranial, was scanned from dorsal to ventral evaluating for abnormally-located mese...
Method to calibrate phase fluctuation in polarization-sensitive swept-source optical coherence tomography.
Journal of biomedical optics    August 3, 2011   Volume 16, Issue 7 070502 doi: 10.1117/1.3597721
Lu Z, Kasaragod DK, Matcher SJ.We present a phase fluctuation calibration method for polarization-sensitive swept-source optical coherence tomography (PS-SS-OCT) using continuous polarization modulation. The method uses a low-voltage broadband polarization modulator driven by a synchronized sinusoidal burst waveform rather than an asynchronous waveform, together with the removal of the global phases of the measured Jones matrices by the use of matrix normalization. This makes it possible to average the measured Jones matrices to remove the artifact due to the speckle noise of the signal in the sample without introducing aux...
Distal border fragments and shape of the navicular bone: radiological evaluation in lame horses and horses free from lameness.
Equine veterinary journal    July 27, 2011   Volume 44, Issue 3 325-331 doi: 10.1111/j.2042-3306.2011.00429.x
Biggi M, Dyson S.The significance of distal border fragments of the navicular bone is not well understood. There are also no objective data about changes in thickness and proximal/distal extension of the palmar cortex of the navicular bone. Objective: To describe the distribution of distal border fragments and their association with other radiological abnormalities of the navicular bone and describe the shape of the navicular bone in sound horses and horses with foot-related lameness, including navicular pathology. Methods: Sound horses had radiographs acquired as part of a prepurchase examination. Lame horses...
Comparisons of computed tomography, contrast-enhanced computed tomography and standing low-field magnetic resonance imaging in horses with lameness localised to the foot. Part 2: Lesion identification.
Equine veterinary journal    June 23, 2011   Volume 44, Issue 2 149-156 doi: 10.1111/j.2042-3306.2011.00386.x
Vallance SA, Bell RJ, Spriet M, Kass PH, Puchalski SM.No previous study compares computed tomography (CT), contrast-enhanced computed tomography (CECT) and standing low-field magnetic resonance imaging (LFMRI) to detect lesions in horses with lameness localised to the foot. This study will help clinicians understand the limitations of these techniques. Objective: To determine if CT, CECT and LFMRI would identify lesions within the distal limb and document discrepancies with lesion distribution and lesion classification. Methods: Lesions in specific structures identified on CT and MR images of feet (31 limbs) from the same horse were reviewed and ...
The use of computed tomographic three-dimensional reconstructions to develop instructional models for equine pelvic ultrasonography. Whitcomb MB, Doval J, Peters J.Ultrasonography has gained increased utility to diagnose pelvic fractures in horses; however, internal pelvic contours can be difficult to appreciate from external palpable landmarks. We developed three-dimensional (3D) simulations of the pelvic ultrasonographic examination to assist with translation of pelvic contours into two-dimensional (2D) images. Contiguous 1mm transverse computed tomography (CT) images were acquired through an equine femur and hemipelvis using a single slice helical scanner. 3D surface models were created using a DICOM reader and imported into a 3D modeling and animatio...
The arthroscopic and ultrasonographic boundaries of the equine femorotibial joints.
Equine veterinary journal    June 8, 2011   Volume 44, Issue 1 57-63 doi: 10.1111/j.2042-3306.2011.00369.x
Barrett MF, Frisbie DD, McIlwraith CW, Werpy NM.While descriptions of the visible soft tissues of the femorotibial joints exist for both arthroscopy and ultrasonography, there are few examples in the literature that discuss in detail the combined findings of these modalities. Objective: To further elucidate the ultrasonographic and arthroscopic boundaries of the normal equine femorotibial joints and improve the understanding of the benefits and limitations of each individual modality. Methods: Simultaneous arthroscopy and ultrasonography were performed in 10 equine cadaver stifles as well as bilateral stifles on a horse that underwent nonre...
Impact of successive freezing-thawing cycles on 3-T magnetic resonance images of the digits of isolated equine limbs.
American journal of veterinary research    June 2, 2011   Volume 72, Issue 6 780-790 doi: 10.2460/ajvr.72.6.780
Bolen GE, Haye D, Dondelinger RF, Massart L, Busoni V.To assess the impact of cycles of freezing and thawing on magnetic resonance (MR) images (obtained by use of a 3-T magnet) of equine feet examined ex vivo. Methods: 9 forelimbs from 9 horse cadavers. Methods: 9 forefeet underwent MR imaging first at ambient temperature within 12 hours after the horses' death and then after each freezing-thawing cycle. Three digits underwent freezing and thawing (at 4°C for 36 hours) 2 times, 3 digits underwent freezing and thawing (at 4°C for 36 hours) once and rescanning after 24 hours at ambient temperature, and 3 digits underwent freezing and thawing at a...
Comparisons of computed tomography, contrast enhanced computed tomography and standing low-field magnetic resonance imaging in horses with lameness localised to the foot. Part 1: anatomic visualisation scores.
Equine veterinary journal    May 30, 2011   Volume 44, Issue 1 51-56 doi: 10.1111/j.2042-3306.2011.00372.x
Vallance SA, Bell RJ, Spriet M, Kass PH, Puchalski SM.To date, few reports exist comparing magnetic resonance imaging (MRI) and computed tomography (CT) for imaging of the equine distal limb, yet clinicians are required to decide which modality to use regularly. Objective: To report and compare anatomic visualisation scores obtained for CT, contrast enhanced CT (CECT) and standing low-field MRI (LFMRI) in the equine foot. Objective: Anatomic visualisation score discrepancies would exist between CT, CECT and LFMRI. Methods: Images of 22 lame horses (31 limbs) undergoing both CT and LFMRI of the foot were reviewed. When available, CECT images were ...
1 17 18 19 20 21 36