Imaging techniques in horses encompass a range of diagnostic tools used to visualize the internal structures and systems of equine patients. These techniques assist in the diagnosis, monitoring, and treatment planning of various conditions affecting horses. Common imaging modalities include radiography (X-rays), ultrasonography, magnetic resonance imaging (MRI), and computed tomography (CT). Each technique offers unique advantages in terms of resolution, depth of penetration, and the type of tissues that can be examined. For instance, radiography is frequently used for assessing bone structures, while ultrasonography is often employed for soft tissue evaluation. MRI and CT provide detailed cross-sectional images, aiding in the assessment of complex anatomical regions. This page compiles peer-reviewed research studies and scholarly articles that explore the application, advancements, and comparative efficacy of imaging techniques in equine veterinary medicine.
Spriet M, Murphy B, Vallance SA, Vidal MA, Whitcomb MB, Wisner ER.Magic angle magnetic resonance (MR) imaging consists of imaging tendons at 55° to the magnetic field. In people, magic angle MR imaging is valuable for detection of chronic tendon lesions and allows calculation of tendon T1 values. Increased T1 values occur in people with chronic tendinopathy. The T1 values of normal equine tendons have been reported but there are no available data for abnormal equine tendons. Twelve limbs were studied. Two limbs had diode laser tendon lesions induced postmortem, four limbs had diode laser tendon lesions induced in vivo and six limbs had naturally occurring t...
Daniel AJ, Judy CE, Rick MC, Saveraid TC, Herthel DJ.To describe pathological findings identified with MRI in the distal tarsal bones of horses with unilateral hind limb lameness attributable to tarsal pain and to compare the usefulness of MRI with that of radiography and nuclear scintigraphy in evaluation of this region. Methods: Retrospective case series. Methods: 20 lame horses. Methods: In all horses, MRI, radiography (4 standard projections), and nuclear scintigraphy of the tarsus had been performed. Horses were excluded if the results of all 3 imaging modalities were not available or if lameness was detected in more than 1 limb. Pathologic...
Virén T, Huang YP, Saarakkala S, Pulkkinen H, Tiitu V, Linjama A, Kiviranta I, Lammi MJ, Brünott A, Brommer H, Van Weeren R, Brama PA, Zheng YP....The aim of this study was to compare sensitivity of ultrasound and optical coherence tomography (OCT) techniques for the evaluation of the integrity of spontaneously repaired horse cartilage. Articular surfaces of horse intercarpal joints, featuring both intact tissue and spontaneously healed chondral or osteochondral defects, were imaged ex vivo with arthroscopic ultrasound and laboratory OCT devices. Quantitative ultrasound (integrated reflection coefficient (IRC), apparent integrated backscattering coefficient (AIB) and ultrasound roughness index (URI)) and optical parameters (optical refle...
Vaccaro C, Busetto R, Bernardini D, Anselmi C, Zotti A.To evaluate the precision and accuracy of assessing bone mineral density (BMD) by use of mean gray value (MGV) on digitalized and digital images of conventional and digital radiographs, respectively, of ex vivo bovine and equine bone specimens in relation to the gold-standard technique of dual-energy x-ray absorptiometry (DEXA). Methods: Left and right metatarsal bones from 11 beef cattle and right femurs from 2 horses. Methods: Bovine specimens were imaged by use of conventional radiography, whereas equine specimens were imaged by use of computed radiography (digital radiography). Each specim...
Claerhoudt S, Bergman HJ, Van Der Veen H, Duchateau L, Raes EV, Saunders JH.Distal border synovial invaginations of the distal sesamoid bone are radiographically assessed during the selection process of horses admitted as breeding stallions or in purchase examinations. Nowadays, many moderately or some deeply penetrating proximally enlarged synovial invaginations are considered as moderate or severe radiographic findings. Objective: To measure the difference between and agreement of the morphology of distal border synovial invaginations on radiography vs. computed tomography (CT). It was hypothesised that the morphology of distal border synovial invaginations would be...
Schneeweiss W, Puggioni A, David F.Diagnosis and treatment of pathologies involving synovial structures in the shoulder region are technically difficult. Ultrasound-guided (UG) injection techniques have been shown to be highly accurate, safe and reliable for various structures in human and equine patients. Objective: To develop easy-to-use and reliable UG injection techniques for the infraspinatus bursa (IB), bicipital bursa (BB) and scapulohumeral joint (SHJ) and to compare them with conventional 'blind' methods. Methods: Eight pairs of equine shoulders were positioned on a computed-tomography (CT) table with left and right sh...
Schramme M, Josson A, Linder K.The suspensory ligament is difficult to image accurately, partly because it contains ligamentous fibers, as well as noncollagenous adipose and muscle tissue in the normal horse. Our hypothesis was that magnetic resonance (MR) imaging would be more accurate than ultrasonography in identifying the size of the suspensory ligament and the presence and size of noncollagenous tissues within the ligament. Eleven horses were used for ultrasonographic and MR imaging and histologic evaluation of the rear suspensory ligament. The origin and body of the normal suspensory ligament had a heterogenous appear...
Labens R, Blikslager A.Methods of 3D wound imaging in man play an important role in monitoring of healing and determination of the prognosis. Standard photographic assessments in equine wound management consist of 2D analyses, which provide little quantitative information on the wound bed. Objective: 3D imaging of equine wounds is feasible using principles of stereophotogrammetry. 3D measurements differ significantly and are more precise than results with standard 2D assessments. Methods: Repeated specialised photographic imaging of 4 clinical wounds left to heal by second intention was performed. The intraoperator ...
Adrian AM, Koene M, Roberts S, Doughty P, Bolas N, Kinns J, Brehm W, Gerlach K.The extent of fat suppression using short tau inversion recovery (STIR) imaging is variable between horses. Our aim was to determine if patient's age and/or hoof temperature have an influence on the T(1) relaxation time of bone marrow in the equine distal limb, thereby affecting the suppression of fat signal. Magnetic resonance imaging was conducted on standing horses and cadaver samples using a low-field magnet (0.27 T). The hoof temperature was measured at the lateral side of the coronary band. A modified inversion recovery fast spin-echo (IR-FSE) sequence was used to measure the signal inte...
Buck AR, Verstraete N, Li Y, Schweizer A, Snedeker JG, Buck FM.To assess the capability of a commercial sonoelastography system to detect small tendon lesions by quantitative analysis of elastogram profiles. Methods: Strips of equine digital flexor tendons were used to model small human tendons. Two tendons were examined. From each tendon, six unmodified tendon strips (controls) and six tendon strips with a central defect of the same tendons were compared. The tendon strips were placed under a physiological tensile strain of 5%. Sonoelastographic visualization of the strain profile was performed. Regions of interest (ROI) were defined left and right of th...
Kotoyori Y, Yokoo N, Ito K, Murase H, Sato F, Korosue K, Nambo Y.The objective was to assess the optimal procedure for real-time, three-dimensional (3D) ultrasound (US) imaging for assessing the equine fetus during the first half of gestation and the possibility of using 3D US imaging of the equine fetus in clinical applications. Seventeen pregnant mares were examined by 3D US between Days 35 and 180 of gestation. Abdominal and endo-vaginal real-time 3D transducers used in human medicine were used for transrectal and transvaginal examinations, respectively. Images were recorded by both 3D stationary and real-time movies. In a comparison of four methods, tra...
Schramel J, Nagel C, Auer U, Palm F, Aurich C, Moens Y.The regional distribution of ventilation in conscious standing pregnant Shetland pony mares was investigated by Electrical Impedance Tomography (EIT). Six ponies were repeatedly examined a minimum of four weeks prior to (antepartum, AP) until three weeks after parturition (postpartum, PP). From the cross-sectional ventilation image the ventral to dorsal (V/D), left to right (L/R) ventilation distribution ratio and the relative ventilation in four horizontal regions of interest (ROI) placed symmetrically in the chest was analyzed. Antepartum V/D was 0.74 ± 0.09 on day -28 ± 3 (AP28) and decre...
Vergari C, Ravary-Plumioën B, Evrard D, Laugier P, Mitton D, Pourcelot P, Crevier-Denoix N.Axial speed of sound (SOS) measurements have been successfully applied to noninvasively evaluate tendon load, while preliminary studies showed that this technique also has a potential clinical interest in the follow up of tendon injuries. The ultrasound propagation theory predicts that the SOS is determined by the effective stiffness, mass density and Poisson's ratio of the propagating medium. Tendon stiffness characterizes the tissue's mechanical quality, but it is often measured in quasi-static condition and for entire tendon segments, so it might not be the same as the effective stiffness w...
Pirie CG, Pizzirani S. To describe a novel digital single lens reflex (dSLR) camera adaptor for anterior and posterior segment photography. Methods: The adaptor was used to evaluate canine, feline, and equine patients presenting to Tufts Ophthalmology service. Anterior segment imaging was conducted with the adaptor mounted between a dSLR camera body (Canon 7D) and a macro lens (Canon EF-S 60mm/f2.8). Posterior segment imaging was performed with the aid of an indirect ophthalmic lens mounted in front of the macro lens. Coaxial illumination during viewing was provided by a single white light-emitting diode (LE...
Rush BR, Biller DS, Davis EG, Higginbotham ML, Klocke E, Miesner MD, Rankin DC.Kansas State University implemented a Web-based program to assess students' competency to perform technical skills during clinical rotations throughout the fourth year of the veterinary curriculum. The classes of 2009 and 2010 recorded a minimum number of procedures (104 and 103, respectively) from a menu of more than 220 recommended procedures. Procedures were categorized by species (small animal, equine, food animal) and disciplines (imaging, anesthesia, diagnostic medicine/necropsy). Ophthalmology was added as a fourth discipline for the class of 2010. Students recorded procedures into the ...
Henry Barton M.The recent introduction of more affordable and portable ultrasound equipment makes it possible to perform transabdominal ultrasonography on equine patients in the field. Clipping the hair is not always necessary: intraabdominal structures can be quickly evaluated by soaking hair with isopropyl alcohol and using a 3.0- to 3.5-MHz curvilinear transducer. The ultrasonographer must be acquainted with the location and architecture of normal intraabdominal structures and simultaneously mindful of the depth of the viewing field, the tissue interface densities, the orientation of the transducer relati...
Griffeth GC, Callori N, Rankin SC, Boston RC, Morris DO.Meticillin-resistant Staphylococcus aureus (MRSA) causes serious skin and soft-tissue infections of humans and animals. Multiple strains of MRSA have been characterized, and one in particular, designated as strain USA 500, causes infections predominantly of horses and the people who work with them. The purpose of this study was to optimize an assay which could subsequently be used to compare the relative avidity of different S. aureus strains for equine corneocytes. Corneocytes were collected from the perineal skin of 10 healthy horses onto adhesive discs. The discs were then incubated at 37°...
Schmidburg I, Pagger H, Zsoldos RR, Mehnen J, Peham C, Licka TF.Laterolateral radiographs of equine necks are reported to be inaccurate in determining the site of spinal cord lesions even when a myelogram is carried out. The goal of this study was to assess constrictions present in the cervical vertebral canal at any time point throughout the extremes of movement. Sixteen equine cervical vertebral columns without history of cervical disease were used. After removal of the spinal cord, the dura mater was filled with polyurethane foam and during its plastic phase the cervical vertebral column was passively moved in flexion-extension, lateral bending and 30°...
Mizuno K, Nagatani Y, Yamashita K, Matsukawa M.Ultrasound propagation in cancellous bone (porous media) under the condition of closed pore boundaries was investigated. A cancellous bone and two plate-like cortical bones obtained from a racehorse were prepared. A water-immersion ultrasound technique in the MHz range and a three-dimensional elastic finite-difference time-domain (FDTD) method were used to investigate the waves. The experiments and simulations showed a clear separation of the incident longitudinal wave into fast and slow waves. The findings advance the evaluation of bones based on the two-wave phenomenon for in vivo assessment...
Urraca del Junco CI, Shaw DJ, Weaver MP, Schwarz T.Magnetic susceptibility artifacts as a result of metal debris from shoeing are a common problem in magnetic resonance imaging of the equine foot. Our purpose was to determine the suitability of radiography as a screening tool for the presence and location of metallic particles in the equine foot and to predict the size of the resultant magnetic susceptibility artifact. Radiography had 100% sensitivity for detection of metal particles > or = 1 mm diameter. Metal particles of known diameter were placed within the hoof wall of 22 cadaver feet and scanned with a low-field strength MR imaging un...
Grenager NS, Durham MG.This report describes the use of ultrasound to diagnose right dorsal displacement of the large colon (RDDLC) in 13 horses prior to surgery. Horses had ultrasonographic examinations performed of the right lateroventral aspect of the abdomen upon admission to the hospital with a 2-5 MHz broadband curvilinear sector scanning transducer after alcohol was used to wet the hair. First, the caecal vessels were identified in the right flank and followed medially and cranially. Next, each intercostal space, from caudal to cranial, was scanned from dorsal to ventral evaluating for abnormally-located mese...
Lu Z, Kasaragod DK, Matcher SJ.We present a phase fluctuation calibration method for polarization-sensitive swept-source optical coherence tomography (PS-SS-OCT) using continuous polarization modulation. The method uses a low-voltage broadband polarization modulator driven by a synchronized sinusoidal burst waveform rather than an asynchronous waveform, together with the removal of the global phases of the measured Jones matrices by the use of matrix normalization. This makes it possible to average the measured Jones matrices to remove the artifact due to the speckle noise of the signal in the sample without introducing aux...
Biggi M, Dyson S.The significance of distal border fragments of the navicular bone is not well understood. There are also no objective data about changes in thickness and proximal/distal extension of the palmar cortex of the navicular bone. Objective: To describe the distribution of distal border fragments and their association with other radiological abnormalities of the navicular bone and describe the shape of the navicular bone in sound horses and horses with foot-related lameness, including navicular pathology. Methods: Sound horses had radiographs acquired as part of a prepurchase examination. Lame horses...
Vallance SA, Bell RJ, Spriet M, Kass PH, Puchalski SM.No previous study compares computed tomography (CT), contrast-enhanced computed tomography (CECT) and standing low-field magnetic resonance imaging (LFMRI) to detect lesions in horses with lameness localised to the foot. This study will help clinicians understand the limitations of these techniques. Objective: To determine if CT, CECT and LFMRI would identify lesions within the distal limb and document discrepancies with lesion distribution and lesion classification. Methods: Lesions in specific structures identified on CT and MR images of feet (31 limbs) from the same horse were reviewed and ...
Whitcomb MB, Doval J, Peters J.Ultrasonography has gained increased utility to diagnose pelvic fractures in horses; however, internal pelvic contours can be difficult to appreciate from external palpable landmarks. We developed three-dimensional (3D) simulations of the pelvic ultrasonographic examination to assist with translation of pelvic contours into two-dimensional (2D) images. Contiguous 1mm transverse computed tomography (CT) images were acquired through an equine femur and hemipelvis using a single slice helical scanner. 3D surface models were created using a DICOM reader and imported into a 3D modeling and animatio...
Barrett MF, Frisbie DD, McIlwraith CW, Werpy NM.While descriptions of the visible soft tissues of the femorotibial joints exist for both arthroscopy and ultrasonography, there are few examples in the literature that discuss in detail the combined findings of these modalities. Objective: To further elucidate the ultrasonographic and arthroscopic boundaries of the normal equine femorotibial joints and improve the understanding of the benefits and limitations of each individual modality. Methods: Simultaneous arthroscopy and ultrasonography were performed in 10 equine cadaver stifles as well as bilateral stifles on a horse that underwent nonre...
Bolen GE, Haye D, Dondelinger RF, Massart L, Busoni V.To assess the impact of cycles of freezing and thawing on magnetic resonance (MR) images (obtained by use of a 3-T magnet) of equine feet examined ex vivo. Methods: 9 forelimbs from 9 horse cadavers. Methods: 9 forefeet underwent MR imaging first at ambient temperature within 12 hours after the horses' death and then after each freezing-thawing cycle. Three digits underwent freezing and thawing (at 4°C for 36 hours) 2 times, 3 digits underwent freezing and thawing (at 4°C for 36 hours) once and rescanning after 24 hours at ambient temperature, and 3 digits underwent freezing and thawing at a...
Vallance SA, Bell RJ, Spriet M, Kass PH, Puchalski SM.To date, few reports exist comparing magnetic resonance imaging (MRI) and computed tomography (CT) for imaging of the equine distal limb, yet clinicians are required to decide which modality to use regularly. Objective: To report and compare anatomic visualisation scores obtained for CT, contrast enhanced CT (CECT) and standing low-field MRI (LFMRI) in the equine foot. Objective: Anatomic visualisation score discrepancies would exist between CT, CECT and LFMRI. Methods: Images of 22 lame horses (31 limbs) undergoing both CT and LFMRI of the foot were reviewed. When available, CECT images were ...
Twardock AR.It is well known that skeletal scintigraphy is an imaging modality with high sensitivity but low specificity. Sites of IRU provide good evidence of increased bone turnover but not its specific cause. Results of lameness workups, blocks, and other imaging techniques are required to determine specific causes. Overinterpretation of causes of IRU is tempting, especially in assigning diagnoses to EIBR--adaptive or non-adaptive. Nevertheless, a quarter of a century's experience with equine skeletal scintigraphy has shown that certain patterns and locations can be fairly predictive of certain patholo...
Denoix JM, Busoni V.The ultrasonographic anatomy of the accessory ligament of the superficial digital flexor tendon (AL-SDFT) in the horse is presented. Comparison between anatomical sections of isolated limbs and ultrasound scans of the distal antebrachium in sound horses enabled the authors to establish the normal reference ultrasonographic images of this structure. The AL-SDFT inserts 7-14 cm above the antebrachiocarpal joint on the palmaromedial aspect of the radius. Ultrasonographically it appears as an uniformly echogenic structure located deep to the median artery. The knowledge of ultrasonographic anatomy...
Vörös K, Holmes JR, Gibbs C.This study was performed on 15 horses to validate the cardiac anatomy as imaged with two dimensional echocardiography (2DE) and to determine the accuracy of intracardiac measurements. 2DE images were recorded in five horses in life with a Diasonics DRF100 ultrasound system and a 3.5 MHz transducer in different tomographic planes. After slaughter, the hearts were fixed in 10 per cent formalin. To compare in vivo and in vitro results, the specimens were suspended in a water-filled tank and 2DE images were made using the same transducer positions as in life. In vitro 2DE and autopsy measurements ...
Hirano Y, Kimura J, Nambo Y, Yokota H, Nakamura S, Takemoto S, Himeno R, Mishima T, Matsui M, Miyake YI.The structure of the equine ovary is different from that of other mammals in its extremely large size, the presence of ovarian fossa and the inverted location of its cortex and medulla. A three-dimensional internal structure microscopy (3D-ISM), which consists of a computer-controlled slicer, a CCD camera, a laser disc recorder and a PC, is very useful for the observation of the internal structures in equine ovaries. In addition, the three-dimensional images of follicles and corpus luteum (CL) reconstructed by the segmentation technique can clarify the spatial arrangement in the equine ovary. ...
Votion D, Vandenput S, Duvivier H, Art T, Lekeux P.A method is proposed (1) to create inhalation to perfusion ratio (I/Q) images from equine lung scintiscans and (2) to analyse these I/Q images. This method was applied to five healthy horses in order to establish reference ranges of I/Q distribution pattern. Computed I/Q images were divided in three regions based on the activity due to the inhalation (I) versus perfusion (Q) procedure. For each region a regional mismatching factor (Iri), i.e. the I/Q of the region, and an intraregional mismatching factor (Lri), which expresses the variability of pixels' I/Q within the region, were calculated. ...
Wallace KD, Selcer BA, Tyler DE, Brown J.Ninety-one equine aortic and cranial mesenteric arterial segments were evaluated ultrasonographically in a water bath. On the basis of pathologic evidence of verminous arteritis, arterial segments were classified into 4 categories, and the ultrasonographic characteristics of each group were evaluated. Normal arteries (class 1) were ultrasonographically characterized by a smooth luminal surface layer and uniform wall thickness and echogenicity. Arteries with only histopathologic evidence of verminous arteritis (class 2) were ultrasonographically characterized by a smooth luminal surface layer, ...
Reichel M, Martinek J.Distribution of the electrical field is very important to activate muscle and nerve cells properly. One therapeutic method to treat Recurrent Laryngeal Neuropathy (RLN) in horses can be performed by Functional Electrical Stimulation (FES). Current method to optimize the stimulation effect is to use implanted quadripolar electrodes to the musculus cricoarythenoideus dorsalis (CAD) and testing electrode configuration until best possible optimum is reached. For better understanding and finding of maximum possible activation of CAD a simulation model of the actual entire setting is currently in de...
Ella A, Gomot G, Lévy I, Dominici C, Adriaensen H, Reigner F, Keller M, Guillaume D.Magnetic resonance imaging (MRI) is now widely used in equine veterinary practice. However, the mandatory European legislation regarding horse identification imposes the implantation of a transponder within the fatty tissue of the neck cervical ligament. While performing brain MRI for scientific purposes in ponies, we faced artifacts produced by such transponder and reported here this problem. Indeed, pony mares were anesthetized for 2 hours and placed, bedded on their back, in a 3T MRI scanner. A four-element flexible antenna positioned around the head was used. Three MRI sequences were perfo...
Biggi M, Dyson SJ, Murray RC.Our aims were to evaluate the pattern of radiopharmaceutical uptake in horses with lameness related to the metacarpophalangeal and/or metatarsophalangeal joint and compare the results with similar information from sound horses. It was hypothesized bthat there would be a difference in radiopharmaceutical uptake between the lame and contralateral limb in unilaterally lame horses and that there would be a difference between lame and sound horses. Nuclear scintigraphic images of 43 horses with forelimb lameness and 30 horses with hindlimb lameness were evaluated. In all horses lameness was improve...
Gatherer ME, Faulkner J, Voûte LC.The aim of this study was to compare the radiation doses received by the personnel drawing up and injecting the radiopharmaceutical and operating the nuclear scintigraphy equipment, and those restraining nine horses while they were being scanned during scintigraphic investigations of lameness. Sensitive electronic dosimeters were worn by the personnel and the doses they received during the administration of the radiopharmaceutical and during the period of image acquisition were recorded at intervals. On average, 90 per cent of the total doses were received during the period of image acquisitio...
Neuhauser S, Handler J.The aims of this study were to compare two different methods of quantifying the colour of the luminal surface of the equine endometrium and to relate the results to histopathological evidence of inflammation and fibrosis. The mucosal surfaces of 17 equine uteri obtained from an abattoir were assessed using a spectrophotometer and by computer-assisted analysis of photographs. Values were converted into L(*)a(*)b(*) colour space. Although there was significant correlation between the two methods of quantification, variations in 'brightness', 'red' and 'yellow' values were noted. Within a given u...
Wilson DA, Badertscher RR, Boero MJ, Baker GJ, Foreman JH.Ultrasonography was used to evaluate the ventral midline incisions of 21 ponies following exploratory laparotomy. The incisions were evaluated before surgery and at weekly intervals from one to seven weeks after surgery. Both 5.0 and 7.5 MHz linear array and 7.5 MHz sector transducers were used for the evaluations. The incisional complications observed were drainage, oedema, suture sinus formation, suture abscess, superficial dehiscence and incisional hernia. Ultrasonographic imaging of the ventral midline incision was an easy, reliable and objective method for detecting and monitoring the pro...