Analyze Diet

Topic:Imaging Techniques

Imaging techniques in horses encompass a range of diagnostic tools used to visualize the internal structures and systems of equine patients. These techniques assist in the diagnosis, monitoring, and treatment planning of various conditions affecting horses. Common imaging modalities include radiography (X-rays), ultrasonography, magnetic resonance imaging (MRI), and computed tomography (CT). Each technique offers unique advantages in terms of resolution, depth of penetration, and the type of tissues that can be examined. For instance, radiography is frequently used for assessing bone structures, while ultrasonography is often employed for soft tissue evaluation. MRI and CT provide detailed cross-sectional images, aiding in the assessment of complex anatomical regions. This page compiles peer-reviewed research studies and scholarly articles that explore the application, advancements, and comparative efficacy of imaging techniques in equine veterinary medicine.
In vivo measurement of bone quality in the horse: estimates of precision for ultrasound velocity measurement and single photon absorptiometry.
Medical & biological engineering & computing    January 1, 1992   Volume 30, Issue 1 41-45 doi: 10.1007/BF02446191
Buckingham SH, Jeffcott LB, Anderson GA, McCartney RN.The in vivo precision of ultrasound velocity measurement and single photon absorptiometry for the assessment of equine bone quality is discussed. In vivo precisions for ultrasound velocity measurements were less than 0.5 per cent, whereas cortical cross-sectional area, compact bone density and modulus of elasticity were around 1 per cent, and bone mineral content and density were just over 2 per cent. Except for ultrasound velocity, substantial improvements could be achieved by taking the mean of five readings for each measurement. The long-term precision of the techniques was also high, with ...
An ultrasonographic off-set system for examination of equine tendons and ligaments.
American journal of veterinary research    December 1, 1991   Volume 52, Issue 12 1945-1947 
Wood AK, Newell WH, Borg RP.In a dorsal plane, an improved ultrasonographic off-set system was used to obtain serial ultrasonographic images with enhanced anatomic and pathologic detail of the tendons, ligaments, and associated structures of the limbs of 100 horses. The off-set provided good acoustic coupling between a linear array ultrasonographic transducer and the horse's skin. A water-soluble gel contained within the off-set had acoustic properties similar to those of mammalian soft tissues.
Measurement of cardiac dimensions with two-dimensional echocardiography in the living horse.
Equine veterinary journal    November 1, 1991   Volume 23, Issue 6 461-465 doi: 10.1111/j.2042-3306.1991.tb03762.x
Voros K, Holmes JR, Gibbs C.Two-dimensional echocardiography (2DE) was performed on 22 unsedated Thoroughbred and part Thoroughbred horses weighing between 411 and 650 kg to establish normal reference values for 2DE measurements. Animals stood during examinations performed with a 3.5 MHz mechanical sector transducer using various transducer positions and tomographic planes. Right ventricular diameter (RVD), ventricular septal thickness (VSTh), aortic diameter (AoD), area of the chordal lumen of the left ventricle (CTA), left ventricular diameter (LVD) and left atrial diameter (LAD) were determined at ventricular end-dias...
A technique for transrectal ultrasonography of stallions during ejaculation.
Theriogenology    November 1, 1991   Volume 36, Issue 5 831-837 doi: 10.1016/0093-691x(91)90349-i
Weber JA, Woods GL.A technique was developed in which the accessory sex glands of stallions were visualized with transrectal ultrasonography during ejaculation. The technique was judged to be effective, since 10 of 11 stallions were trained to tolerate transrectal ultrasonography during ejaculation; they ejaculated during 195 of 200 attempts, and acceptable visualization of their accessory sex glands and excurrent ducts occurred during 97 of 195 ejaculations. Sixty-five percent (89 136 ) of the recordings were successful for stallions that weighed more than 300 kg, whereas 14% (8 59 ) of the recordings were succ...
Use of nonimaging nuclear medicine techniques to assess the effect of flunixin meglumine on effective renal plasma flow and effective renal blood flow in healthy horses.
American journal of veterinary research    October 1, 1991   Volume 52, Issue 10 1619-1621 
Held JP, Daniel GB.The effect of flunixin meglumine on renal function was studied in 6 healthy horses by use of nonimaging nuclear medicine techniques. Effective renal plasma flow (ERPF) and effective renal blood flow (ERBF) were determined by plasma clearance of 131I-orthoiodohippuric acid before and after administration of flunixin meglumine. Mean ERPF and ERBF was 6.03 ml/min/kg and 10.7 ml/min/kg, respectively, before treatment and was 5.7 ml/min/kg and 9.7 ml/min/kg, respectively, after treatment. Although ERPF and ERBF decreased after flunixin meglumine administration, the difference was not statistically ...
Soft palate hypoplasia in a horse.
The Veterinary record    September 28, 1991   Volume 129, Issue 13 284-286 doi: 10.1136/vr.129.13.284
Proudman CJ, Knottenbelt DC, May SA, Edwards GB.Several imaging techniques were used to diagnose hypoplasia of the soft palate in a horse. The absence of the caudal soft palate, hypertrophied lymphoid tissue and the formation of a pseudouvula were observed endoscopically. Plain and contrast radiography were used to demonstrate a soft palate remnant and to identify structures rostral to the epiglottis. Retrograde endoscopy of the pharynx via a tracheotomy incision is described.
The scintigraphic detection of muscle damage.
Equine veterinary journal    September 1, 1991   Volume 23, Issue 5 327-328 doi: 10.1111/j.2042-3306.1991.tb03731.x
Hornof WJ, Koblik PD.No abstract available
Scintigraphic identification of skeletal muscle damage in horses 24 hours after strenuous exercise.
Equine veterinary journal    September 1, 1991   Volume 23, Issue 5 347-352 doi: 10.1111/j.2042-3306.1991.tb03736.x
Morris E, Seeherman HJ, O'Callaghan MW, Schelling SH, Paradis MR, Steckel RS.The uptake of the bone-seeking radiopharmaceutical 99mTc-MDP by damaged skeletal muscle in horses is evaluated. Twenty-four hours following strenuous exercise, 109 racehorses with a history of inadequate athletic performance and subtle lameness were imaged using scintigraphic techniques. Ten horses (9.2 per cent) demonstrated abnormal uptake of the radioisotope within skeletal muscles. A muscle biopsy from one of these horses confirmed that the muscles with increased scintigraphic activity had histologic evidence of rhabdomyolysis. This technique allows localisation and relative quantification...
Ultrasonographic evaluation of horses with thrombophlebitis of the jugular vein: 46 cases (1985-1988).
Journal of the American Veterinary Medical Association    August 1, 1991   Volume 199, Issue 3 370-373 
Gardner SY, Reef VB, Spencer PA.Medical records of 46 horses with jugular vein thrombophlebitis that were evaluated ultrasonographically were reviewed. The ultrasonographic appearance of the thrombus within the jugular vein was classified as noncavitating if it had uniform low to medium amplitude echoes, or as cavitating if it was heterogenous with anechoic to hypoechoic areas representing fluid or necrotic areas within the thrombus, and/or hyperechoic areas representing gas. Signs of pain on palpation of the affected vein (P less than 0.001), heat over the vein (P = 0.001), and swelling of the vein (P less than 0.05) were s...
Future diagnostic methods. A brief look at new technologies and their potential application to equine diagnosis.
The Veterinary clinics of North America. Equine practice    August 1, 1991   Volume 7, Issue 2 467-479 doi: 10.1016/s0749-0739(17)30510-2
O'Callaghan MW.We live in an age in which highly sophisticated computerized equipment and imaging methods are becoming increasingly available. Demand from clients requires that we as veterinary professionals keep our eyes on the future potential of these technologies for diagnosis and treatment. This article briefly reviews some of the techniques that are just around the corner for the progressive equine practitioner.
The integration of radiography and alternative imaging methods in the diagnosis of equine orthopedic disease.
The Veterinary clinics of North America. Equine practice    August 1, 1991   Volume 7, Issue 2 339-364 doi: 10.1016/s0749-0739(17)30503-5
O'Callaghan MW.There is increasing demand on equine practitioners to provide confirmation of their diagnoses. For obscure lameness and for many of the more difficult locomotory problems presented in referral hospitals, the question to be answered is not only how to make the most accurate diagnosis but also how to document the findings so that there is less doubt in the mind of the client. This article describes a quasi algorithmic approach to choosing the best combinations of the increasingly sophisticated imaging methods available for evaluation of orthopedic disease.
Quantitative evaluation of the remodeling response of the proximal sesamoid bones to training-related stimuli in Thoroughbreds.
American journal of veterinary research    August 1, 1991   Volume 52, Issue 8 1350-1356 
Young DR, Nunamaker DM, Markel MD.Eight untrained 2-year-old Thoroughbred horses were used in a study of the remodeling response of the proximal sesamoid bone (PSB) to training-related stimuli. Two horses each were assigned to 1 of 4 groups: group 1, untrained, pasture turnout (control); group 2, modified-classically trained, dirt track; group 3, classically trained, dirt track; and group 4, classically trained, wood chip track. Horses were given fluorochromic bone labels every 28 days during training. All horses were euthanatized after 5 months of training, and the proximal sesamoid bones (PSB) were removed. A midsagittal sec...
Advances in diagnostic ultrasonography.
The Veterinary clinics of North America. Equine practice    August 1, 1991   Volume 7, Issue 2 451-466 doi: 10.1016/s0749-0739(17)30509-6
Reef VB.A wide variety of ultrasonographic equipment currently is available for use in equine practice, but no one machine is optimal for every type of imaging. Image quality is the most important factor in equipment selection once the needs of the practitioner are ascertained. The transducer frequencies available, transducer footprints, depth of field displayed, frame rate, gray scale, simultaneous electrocardiography, Doppler, and functions to modify the image are all important considerations. The ability to make measurements off of videocassette recorder playback and future upgradability should be ...
Thermography as an aid to the clinical lameness evaluation.
The Veterinary clinics of North America. Equine practice    August 1, 1991   Volume 7, Issue 2 311-338 doi: 10.1016/s0749-0739(17)30502-3
Turner TA.Thermography has been shown to be a practical aid in the clinical evaluation of lameness. This modality specifically increases the accuracy of diagnosis. Thermography represents skin temperature, usually pictorially. The techniques involve contacting and noncontacting modalities. Noncontacting thermography, which detects infrared radiation, is the most accurate. In order to be accurate, thermography must be performed in a temperature-controlled, draft-free area. The area should be protected from sunlight to avoid erroneous heating of the skin, and the hair length should be uniform. Thermograph...
Radiographic technique for the pelvis in the standing horse.
Equine veterinary journal    July 1, 1991   Volume 23, Issue 4 312-314 doi: 10.1111/j.2042-3306.1991.tb03725.x
May SA, Patterson LJ, Peacock PJ, Edwards GB.No abstract available
Ultrasonographic evaluation of fetlock annular ligament constriction in the horse.
Equine veterinary journal    July 1, 1991   Volume 23, Issue 4 285-288 doi: 10.1111/j.2042-3306.1991.tb03719.x
Dik KJ, van den Belt AJ, Keg PR.The diagnosis of restriction of free movement of the flexor tendons through the fetlock canal usually rests on the characteristic clinical appearance of this condition, or airtendography. In a series of seven normal Warmblood horses and 16 diseased horses of various breeds, the efficacy of ultrasonography in the diagnosis of this condition was determined. In normal limbs, the annular ligament is a very thin structure usually not visible on sonograms. In diseased limbs, ultrasonography outlined flexor tendon injury, distension and thickening of the digital sheath, peritendovaginal tissue prolif...
Ultrasonographic detection of chronic epididymitis in a stallion.
Journal of the American Veterinary Medical Association    April 15, 1991   Volume 198, Issue 8 1417-1420 
Traub-Dargatz JL, Trotter GW, Kaser-Hotz B, Bennett DG, Kiper ML, Veeramachaneni DN, Squires E.Clinical signs of chronic epididymitis in a stallion included recurrent signs of inguinal pain--retraction of the right testis into the inguinal area, resentment of palpation of the right testis, and right-sided scrotal swelling. The tail of the right epididymis was firm and seemed to be adhered to the testis. The tail of the left epididymis felt firmer than normal. Ultrasonographically, the diameter of the head of the epididymis was considered larger than normal, was hyperechoic in relation to the right testis, and had an irregular border. Several bright 1- to 5-mm-diameter echogenic areas th...
Pathway of ultrasound waves in the equine third metacarpal bone.
Journal of biomedical engineering    March 1, 1991   Volume 13, Issue 2 113-118 doi: 10.1016/0141-5425(91)90057-e
Langton CM, Riggs CM, Evans GP.The velocity of ultrasound waves through bone has been used widely as a non-invasive method for assessing bone quality. Accurate measurement of velocity depends on accurate assessment of the distance travelled by the sound wave. It has been argued that the sonic pathway is deflected around the marrow cavity and so does not follow a straight line through the bone; therefore, correction factors have been developed to account for the extra distance travelled. This hypothesis was examined in vitro using sections from the equine third metacarpal bone. Two 1 MHz transducers used with the transmittin...
Anatomical validation of two-dimensional echocardiography in the horse.
Equine veterinary journal    November 1, 1990   Volume 22, Issue 6 392-397 doi: 10.1111/j.2042-3306.1990.tb04302.x
Vörös K, Holmes JR, Gibbs C.This study was performed on 15 horses to validate the cardiac anatomy as imaged with two dimensional echocardiography (2DE) and to determine the accuracy of intracardiac measurements. 2DE images were recorded in five horses in life with a Diasonics DRF100 ultrasound system and a 3.5 MHz transducer in different tomographic planes. After slaughter, the hearts were fixed in 10 per cent formalin. To compare in vivo and in vitro results, the specimens were suspended in a water-filled tank and 2DE images were made using the same transducer positions as in life. In vitro 2DE and autopsy measurements ...
Left ventricular volume determination in the horse by two-dimensional echocardiography: an in vitro study.
Equine veterinary journal    November 1, 1990   Volume 22, Issue 6 398-402 doi: 10.1111/j.2042-3306.1990.tb04303.x
Vörös K, Holmes JR, Gibbs C.This study was designed to evaluate the accuracy of two-dimensional echocardiography (2DE) in determining the left ventricular volume (LVV) of the horse in vitro. After examining the shape of the left ventricular silicon rubber casts of four equine hearts, two modified Simpson's rule methods (Model A and Model B) as combinations of conical shapes and one biplane area-length method as a single cone (Model C) were chosen for volume calculations. One long axis and three short axis planes were used for linear and area 2DE measurements, respectively. The ventricular length (L) was calculated from t...
Radiology in racetrack practice.
The Veterinary clinics of North America. Equine practice    April 1, 1990   Volume 6, Issue 1 31-61 doi: 10.1016/s0749-0739(17)30556-4
Blevins WE, Widmer WR.This article focuses on the principles involved in making radiographs of equine limbs; understanding radiographic anatomy, including normal variations; and principles of radiographic interpretation. The influence of pathogenesis of disease on the radiographic image is considered. Diseases associated with racing as well as the developing racehorse are discussed.
The use of sports medicine techniques in evaluating the problem equine athlete.
The Veterinary clinics of North America. Equine practice    April 1, 1990   Volume 6, Issue 1 239-274 doi: 10.1016/s0749-0739(17)30565-5
Seeherman HJ, Morris E, O'Callaghan MW.Discovering the cause of poor performance in racehorses can often represent a considerable challenge eluding the more common diagnostic techniques available at the racetrack. Application of sports medicine techniques to these problem cases can aid in the diagnosis of poor performance. Central to the development of this capability has been the use of highspeed treadmills, allowing the racehorse to be evaluated in the controlled laboratory setting, at exercise intensities equivalent to those of racing. Video and cinematographic gait analysis can be used in the diagnosis of subtle lameness condit...
Ultrasound as an aid to diagnosis of granulosa cell tumour in the mare.
Equine veterinary journal    March 1, 1990   Volume 22, Issue 2 99-103 doi: 10.1111/j.2042-3306.1990.tb04218.x
Hinrichs K, Hunt PR.The ultrasonic appearance of seven cases of granulosa cell tumour is described, and compared with an ovarian haematoma and an ovarian serous cystadenoma. The granulosa cell tumours varied from being uniformly dense to having one or several large fluid filled cysts. Some tumours resembled the haematoma or cystadenoma and also, in some aspects, normal ovarian structures such as corpora haemorrhagica or follicles in early pregnancy. There was no typical ultrasonographic appearance of the granulosa cell tumours which enabled definitive diagnosis. However, ultrasound may be a diagnostic aid when us...
Diagnostic ultrasonography for evaluation of cryptorchidism in horses.
Journal of the American Veterinary Medical Association    January 15, 1990   Volume 196, Issue 2 297-300 
Jann HW, Rains JR.The location and size of 11 retained testes were accurately determined ultrasonographically. There was 100% correlation between the location of the testis determined by ultrasound vs that determined by surgery. Testicular size determined presurgically in all cases closely approximated the actual size obtained by gross measurement of the excised testis. The cryptorchid testicular echotexture was less dense than that of the normal descended testicles, but was easily identified. Ultrasonographic evaluations were completed by use of an ultrasound base unit with attached 5-MHz transrectal transduce...
Investigations of the horse conceptus via magnetic resonance imaging (MRI) and nitroxide spin labels as contrast agents.
Free radical research communications    January 1, 1990   Volume 9, Issue 3-6 391-397 doi: 10.3109/10715769009145699
Oehler UM, Janzen EG, Betteridge K, Fyfe C, Towner RA, Savage N, Scodras J.Results are presented which illustrate the usefulness of Magnetic Resonance Imaging as applied to the study of living embryos. Nitroxide spin labels were employed as contrast agents to study the structure and properties of the embryos. These spin labels offer the additional advantage that they may potentially be bound to biologically important molecules thereby imparting the ability to produce contrast in the MR images to these new molecules. The horse conceptus was chosen over other embryos due to its large size. Whereas the embryos of cattle and swine are sub-millimetre in size, the horse co...
Wounds associated with osseous sequestration and penetrating foreign bodies.
The Veterinary clinics of North America. Equine practice    December 1, 1989   Volume 5, Issue 3 695-708 doi: 10.1016/s0749-0739(17)30583-7
Gift LJ, DeBowes RM.Nonhealing wounds can present a frustrating clinical challenge to the veterinary practitioner. In many cases, healing is delayed by the presence of a foreign body or sequestrum; a review of wounds complicated by the presence of osseous sequestration and penetrating foreign bodies is presented. The typical signs include delayed wound healing and the presence of serous to exudative drainage, which may vary from intermittent to continuous. The use of radiographic or sonographic imaging modalities is often of value in reaching a diagnosis. Removal of the sequestra or foreign body is generally cura...
Misdiagnosis in normal radiographic anatomy: nine structural configurations simulating disease entities in horses.
Journal of the American Veterinary Medical Association    November 1, 1989   Volume 195, Issue 9 1272-1282 
Kneller SK, Losonsky JM.No abstract available
In vitro ultrasonographic appearance of the normal and verminous equine aorta, cranial mesenteric artery, and its branches.
American journal of veterinary research    October 1, 1989   Volume 50, Issue 10 1774-1778 
Wallace KD, Selcer BA, Tyler DE, Brown J.Ninety-one equine aortic and cranial mesenteric arterial segments were evaluated ultrasonographically in a water bath. On the basis of pathologic evidence of verminous arteritis, arterial segments were classified into 4 categories, and the ultrasonographic characteristics of each group were evaluated. Normal arteries (class 1) were ultrasonographically characterized by a smooth luminal surface layer and uniform wall thickness and echogenicity. Arteries with only histopathologic evidence of verminous arteritis (class 2) were ultrasonographically characterized by a smooth luminal surface layer, ...
Technique for transrectal ultrasonography of the cranial mesenteric artery of the horse.
American journal of veterinary research    October 1, 1989   Volume 50, Issue 10 1695-1698 
Wallace KD, Selcer BA, Becht JL.Transrectal ultrasonography was successfully used to image the cranial mesenteric artery and its branches in 23 adult horses. The artery could be imaged from its origin at the aorta distally to identify several bifurcations. The method for transrectal imaging of the cranial mesenteric artery and its major branches required 3 distinct transducer positions. One position was used to locate the cranial mesenteric artery by imaging the caudal portion of the aorta from the aortic bifurcation cranially to the level of the cranial mesenteric artery. The second position was used to image the origin of ...
Ultrasonographic evaluation of the healing of ventral midline abdominal incisions in the horse.
Equine veterinary journal. Supplement    June 1, 1989   Issue 7 107-110 doi: 10.1111/j.2042-3306.1989.tb05667.x
Wilson DA, Badertscher RR, Boero MJ, Baker GJ, Foreman JH.Ultrasonography was used to evaluate the ventral midline incisions of 21 ponies following exploratory laparotomy. The incisions were evaluated before surgery and at weekly intervals from one to seven weeks after surgery. Both 5.0 and 7.5 MHz linear array and 7.5 MHz sector transducers were used for the evaluations. The incisional complications observed were drainage, oedema, suture sinus formation, suture abscess, superficial dehiscence and incisional hernia. Ultrasonographic imaging of the ventral midline incision was an easy, reliable and objective method for detecting and monitoring the pro...