Analyze Diet

Topic:Imaging Techniques

Imaging techniques in horses encompass a range of diagnostic tools used to visualize the internal structures and systems of equine patients. These techniques assist in the diagnosis, monitoring, and treatment planning of various conditions affecting horses. Common imaging modalities include radiography (X-rays), ultrasonography, magnetic resonance imaging (MRI), and computed tomography (CT). Each technique offers unique advantages in terms of resolution, depth of penetration, and the type of tissues that can be examined. For instance, radiography is frequently used for assessing bone structures, while ultrasonography is often employed for soft tissue evaluation. MRI and CT provide detailed cross-sectional images, aiding in the assessment of complex anatomical regions. This page compiles peer-reviewed research studies and scholarly articles that explore the application, advancements, and comparative efficacy of imaging techniques in equine veterinary medicine.
Ultrasonographic evaluation of fetlock annular ligament constriction in the horse.
Equine veterinary journal    July 1, 1991   Volume 23, Issue 4 285-288 doi: 10.1111/j.2042-3306.1991.tb03719.x
Dik KJ, van den Belt AJ, Keg PR.The diagnosis of restriction of free movement of the flexor tendons through the fetlock canal usually rests on the characteristic clinical appearance of this condition, or airtendography. In a series of seven normal Warmblood horses and 16 diseased horses of various breeds, the efficacy of ultrasonography in the diagnosis of this condition was determined. In normal limbs, the annular ligament is a very thin structure usually not visible on sonograms. In diseased limbs, ultrasonography outlined flexor tendon injury, distension and thickening of the digital sheath, peritendovaginal tissue prolif...
Ultrasonographic detection of chronic epididymitis in a stallion.
Journal of the American Veterinary Medical Association    April 15, 1991   Volume 198, Issue 8 1417-1420 
Traub-Dargatz JL, Trotter GW, Kaser-Hotz B, Bennett DG, Kiper ML, Veeramachaneni DN, Squires E.Clinical signs of chronic epididymitis in a stallion included recurrent signs of inguinal pain--retraction of the right testis into the inguinal area, resentment of palpation of the right testis, and right-sided scrotal swelling. The tail of the right epididymis was firm and seemed to be adhered to the testis. The tail of the left epididymis felt firmer than normal. Ultrasonographically, the diameter of the head of the epididymis was considered larger than normal, was hyperechoic in relation to the right testis, and had an irregular border. Several bright 1- to 5-mm-diameter echogenic areas th...
Pathway of ultrasound waves in the equine third metacarpal bone.
Journal of biomedical engineering    March 1, 1991   Volume 13, Issue 2 113-118 doi: 10.1016/0141-5425(91)90057-e
Langton CM, Riggs CM, Evans GP.The velocity of ultrasound waves through bone has been used widely as a non-invasive method for assessing bone quality. Accurate measurement of velocity depends on accurate assessment of the distance travelled by the sound wave. It has been argued that the sonic pathway is deflected around the marrow cavity and so does not follow a straight line through the bone; therefore, correction factors have been developed to account for the extra distance travelled. This hypothesis was examined in vitro using sections from the equine third metacarpal bone. Two 1 MHz transducers used with the transmittin...
Anatomical validation of two-dimensional echocardiography in the horse.
Equine veterinary journal    November 1, 1990   Volume 22, Issue 6 392-397 doi: 10.1111/j.2042-3306.1990.tb04302.x
Vörös K, Holmes JR, Gibbs C.This study was performed on 15 horses to validate the cardiac anatomy as imaged with two dimensional echocardiography (2DE) and to determine the accuracy of intracardiac measurements. 2DE images were recorded in five horses in life with a Diasonics DRF100 ultrasound system and a 3.5 MHz transducer in different tomographic planes. After slaughter, the hearts were fixed in 10 per cent formalin. To compare in vivo and in vitro results, the specimens were suspended in a water-filled tank and 2DE images were made using the same transducer positions as in life. In vitro 2DE and autopsy measurements ...
Left ventricular volume determination in the horse by two-dimensional echocardiography: an in vitro study.
Equine veterinary journal    November 1, 1990   Volume 22, Issue 6 398-402 doi: 10.1111/j.2042-3306.1990.tb04303.x
Vörös K, Holmes JR, Gibbs C.This study was designed to evaluate the accuracy of two-dimensional echocardiography (2DE) in determining the left ventricular volume (LVV) of the horse in vitro. After examining the shape of the left ventricular silicon rubber casts of four equine hearts, two modified Simpson's rule methods (Model A and Model B) as combinations of conical shapes and one biplane area-length method as a single cone (Model C) were chosen for volume calculations. One long axis and three short axis planes were used for linear and area 2DE measurements, respectively. The ventricular length (L) was calculated from t...
Radiology in racetrack practice.
The Veterinary clinics of North America. Equine practice    April 1, 1990   Volume 6, Issue 1 31-61 doi: 10.1016/s0749-0739(17)30556-4
Blevins WE, Widmer WR.This article focuses on the principles involved in making radiographs of equine limbs; understanding radiographic anatomy, including normal variations; and principles of radiographic interpretation. The influence of pathogenesis of disease on the radiographic image is considered. Diseases associated with racing as well as the developing racehorse are discussed.
The use of sports medicine techniques in evaluating the problem equine athlete.
The Veterinary clinics of North America. Equine practice    April 1, 1990   Volume 6, Issue 1 239-274 doi: 10.1016/s0749-0739(17)30565-5
Seeherman HJ, Morris E, O'Callaghan MW.Discovering the cause of poor performance in racehorses can often represent a considerable challenge eluding the more common diagnostic techniques available at the racetrack. Application of sports medicine techniques to these problem cases can aid in the diagnosis of poor performance. Central to the development of this capability has been the use of highspeed treadmills, allowing the racehorse to be evaluated in the controlled laboratory setting, at exercise intensities equivalent to those of racing. Video and cinematographic gait analysis can be used in the diagnosis of subtle lameness condit...
Ultrasound as an aid to diagnosis of granulosa cell tumour in the mare.
Equine veterinary journal    March 1, 1990   Volume 22, Issue 2 99-103 doi: 10.1111/j.2042-3306.1990.tb04218.x
Hinrichs K, Hunt PR.The ultrasonic appearance of seven cases of granulosa cell tumour is described, and compared with an ovarian haematoma and an ovarian serous cystadenoma. The granulosa cell tumours varied from being uniformly dense to having one or several large fluid filled cysts. Some tumours resembled the haematoma or cystadenoma and also, in some aspects, normal ovarian structures such as corpora haemorrhagica or follicles in early pregnancy. There was no typical ultrasonographic appearance of the granulosa cell tumours which enabled definitive diagnosis. However, ultrasound may be a diagnostic aid when us...
Diagnostic ultrasonography for evaluation of cryptorchidism in horses.
Journal of the American Veterinary Medical Association    January 15, 1990   Volume 196, Issue 2 297-300 
Jann HW, Rains JR.The location and size of 11 retained testes were accurately determined ultrasonographically. There was 100% correlation between the location of the testis determined by ultrasound vs that determined by surgery. Testicular size determined presurgically in all cases closely approximated the actual size obtained by gross measurement of the excised testis. The cryptorchid testicular echotexture was less dense than that of the normal descended testicles, but was easily identified. Ultrasonographic evaluations were completed by use of an ultrasound base unit with attached 5-MHz transrectal transduce...
Investigations of the horse conceptus via magnetic resonance imaging (MRI) and nitroxide spin labels as contrast agents.
Free radical research communications    January 1, 1990   Volume 9, Issue 3-6 391-397 doi: 10.3109/10715769009145699
Oehler UM, Janzen EG, Betteridge K, Fyfe C, Towner RA, Savage N, Scodras J.Results are presented which illustrate the usefulness of Magnetic Resonance Imaging as applied to the study of living embryos. Nitroxide spin labels were employed as contrast agents to study the structure and properties of the embryos. These spin labels offer the additional advantage that they may potentially be bound to biologically important molecules thereby imparting the ability to produce contrast in the MR images to these new molecules. The horse conceptus was chosen over other embryos due to its large size. Whereas the embryos of cattle and swine are sub-millimetre in size, the horse co...
Wounds associated with osseous sequestration and penetrating foreign bodies.
The Veterinary clinics of North America. Equine practice    December 1, 1989   Volume 5, Issue 3 695-708 doi: 10.1016/s0749-0739(17)30583-7
Gift LJ, DeBowes RM.Nonhealing wounds can present a frustrating clinical challenge to the veterinary practitioner. In many cases, healing is delayed by the presence of a foreign body or sequestrum; a review of wounds complicated by the presence of osseous sequestration and penetrating foreign bodies is presented. The typical signs include delayed wound healing and the presence of serous to exudative drainage, which may vary from intermittent to continuous. The use of radiographic or sonographic imaging modalities is often of value in reaching a diagnosis. Removal of the sequestra or foreign body is generally cura...
Misdiagnosis in normal radiographic anatomy: nine structural configurations simulating disease entities in horses.
Journal of the American Veterinary Medical Association    November 1, 1989   Volume 195, Issue 9 1272-1282 
Kneller SK, Losonsky JM.No abstract available
In vitro ultrasonographic appearance of the normal and verminous equine aorta, cranial mesenteric artery, and its branches.
American journal of veterinary research    October 1, 1989   Volume 50, Issue 10 1774-1778 
Wallace KD, Selcer BA, Tyler DE, Brown J.Ninety-one equine aortic and cranial mesenteric arterial segments were evaluated ultrasonographically in a water bath. On the basis of pathologic evidence of verminous arteritis, arterial segments were classified into 4 categories, and the ultrasonographic characteristics of each group were evaluated. Normal arteries (class 1) were ultrasonographically characterized by a smooth luminal surface layer and uniform wall thickness and echogenicity. Arteries with only histopathologic evidence of verminous arteritis (class 2) were ultrasonographically characterized by a smooth luminal surface layer, ...
Technique for transrectal ultrasonography of the cranial mesenteric artery of the horse.
American journal of veterinary research    October 1, 1989   Volume 50, Issue 10 1695-1698 
Wallace KD, Selcer BA, Becht JL.Transrectal ultrasonography was successfully used to image the cranial mesenteric artery and its branches in 23 adult horses. The artery could be imaged from its origin at the aorta distally to identify several bifurcations. The method for transrectal imaging of the cranial mesenteric artery and its major branches required 3 distinct transducer positions. One position was used to locate the cranial mesenteric artery by imaging the caudal portion of the aorta from the aortic bifurcation cranially to the level of the cranial mesenteric artery. The second position was used to image the origin of ...
Ultrasonographic evaluation of the healing of ventral midline abdominal incisions in the horse.
Equine veterinary journal. Supplement    June 1, 1989   Issue 7 107-110 doi: 10.1111/j.2042-3306.1989.tb05667.x
Wilson DA, Badertscher RR, Boero MJ, Baker GJ, Foreman JH.Ultrasonography was used to evaluate the ventral midline incisions of 21 ponies following exploratory laparotomy. The incisions were evaluated before surgery and at weekly intervals from one to seven weeks after surgery. Both 5.0 and 7.5 MHz linear array and 7.5 MHz sector transducers were used for the evaluations. The incisional complications observed were drainage, oedema, suture sinus formation, suture abscess, superficial dehiscence and incisional hernia. Ultrasonographic imaging of the ventral midline incision was an easy, reliable and objective method for detecting and monitoring the pro...
Radiographic examination of the equine foot.
The Veterinary clinics of North America. Equine practice    April 1, 1989   Volume 5, Issue 1 47-66 doi: 10.1016/s0749-0739(17)30603-x
Park RD.A complete radiographic examination of the equine foot consists of properly exposed, processed, and positioned radiographs. For radiographic interpretation, in addition to knowing radiographic signs of disease, a knowledge of normal radiographic anatomy and possible insignificant anatomic variations is necessary.
Development of an equine nuclear medicine facility for gamma camera imaging.
Equine veterinary journal    March 1, 1989   Volume 21, Issue 2 86-90 doi: 10.1111/j.2042-3306.1989.tb02100.x
Attenburrow DP, Portergill MJ, Vennart W.A nuclear medicine facility constructed specifically for the application of a gamma camera system to the radioisotope imaging of bone, pulmonary circulation and ventilation in the horse is described. The gamma camera was previously used for human nuclear medicine, and a support for the gamma camera head was specifically designed for this work. Imaging protocols are suggested and the necessary materials for bone and lung studies are described. Images of bone and lung are shown and computer analysis of the data indicated. Imaging times are approximately 1 to 2 mins and typical bone and lung stud...
An application of the image analyzer to the soft radiogram of the third metacarpus in horses.
Nihon juigaku zasshi. The Japanese journal of veterinary science    February 1, 1989   Volume 51, Issue 1 184-186 doi: 10.1292/jvms1939.51.184
Yoshihara T, Kaneko M, Oikawa M, Wada R, Tomioka Y.No abstract available
Ultrasonographic diagnosis of small-intestinal intussusception in three foals.
Journal of the American Veterinary Medical Association    February 1, 1989   Volume 194, Issue 3 395-397 
Bernard WV, Reef VB, Reimer JM, Humber KA, Orsini JA.Small-intestinal intussusceptions were diagnosed in 3 foals. Cross-sectional ultrasonography through the apex of the intussusceptum revealed a target-like pattern with a thick hypoechoic rim. The thick hypoechoic rim was caused by severe edema of the entering and returning walls of the intussusceptum. At the more proximal portion of the intestines, where parietal edema was less severe, the image appeared as 2 concentric rings and an inner circular area. The outer ring and inner circular area were hypoechoic and represented the returning and the entering wall of the intussusceptum. An additiona...
[The appearance of subchondral cystoid defects in the joints of the distal extremities of the horse].
Tierarztliche Praxis    January 1, 1989   Volume 17, Issue 1 79-83 
van Suntum M, Hartung K.Subchondral bone cysts or cyst like lesions are an important hint in the radiographic diagnosis of degenerative joint disease. In this study we set artificial lesions of different size in the subchondral bone of different joint surfaces of horses, and we then tried to determine from which size on these lesions could be made visible on radiographs in different projections. It shows that the possibility of visualization of such lesions is frequently overestimated, cyst like lesions have to be quite large, before they can be seen on routine radiographs.
[The radiologic image of the normal equine tarsus].
Schweizer Archiv fur Tierheilkunde    January 1, 1989   Volume 131, Issue 4 165-175 
Dahn M, Ueltschi G.Normal radiographs of hocks were analyzed for 270 horses (3 views for each hock). They were mainly from young and sound horses. For such animals, the mean number of abnormalities found was 2 to 4.5 for each picture. The mean dimension of certain tarsal bones was measured; geldings had greater bones than mares. An increase of reactions at the origin of the M. interosseus was seen with the age. It was possible to demonstrate that Medichrome films increase the number of discrete abnormalities to be found; this is of particular value for purchase examinations of young horses. The direction of the ...
Ultrasonography of umbilical structures in clinically normal foals.
American journal of veterinary research    December 1, 1988   Volume 49, Issue 12 2143-2146 
Reef VB, Collatos C.The umbilical arteries, urachus, and umbilical vein were scanned ultrasonographically in 13 clinically normal foals that ranged in age from 6 hours to 4 weeks. Sonograms were obtained using a 7.5-MHz sector scanner transducer placed across the midline of the ventral portion of the foal's abdominal wall. The umbilical vein was scanned from the umbilical stalk to its entrance into the hepatic parenchyma. The mean (+/- SD) diameter of the umbilical vein was 0.61 +/- 0.20 cm immediately cranial to the umbilical stalk, 0.52 +/- 0.19 cm midway between the umbilicus and liver, and 0.6 +/- 0.19 cm at ...
Aorto-iliac thrombosis in two horses: clinical course of the disease and use of real-time ultrasonography to confirm diagnosis.
Equine veterinary journal    September 1, 1988   Volume 20, Issue 5 384-387 doi: 10.1111/j.2042-3306.1988.tb01553.x
Edwards GB, Allen WE.No abstract available
Ultrasonic transmission velocity and single photon absorptiometric measurement of metacarpal bone strength: an in vitro study in the horse.
Equine veterinary journal. Supplement    September 1, 1988   Issue 6 80-87 doi: 10.1111/j.2042-3306.1988.tb04652.x
McCarhey RN, Jeffcott LB, McCartney RN.Ten pairs of third metacarpal bones from Thoroughbred horses aged two to 12 years were used to estimate bone strength. Measurements of transverse cortical ultrasound velocity, cortical cross sectional area and bone mineral content were made using ultrasonic transmission velocity and single photon absorptiometry. These data were used to determine bone mineral density, compact bone density and modulus of elasticity. The results were compared with those measured by direct means or chemical analysis and satisfactory correlations were obtained between estimated and measured values. Single photon ab...
Ultrasonic imaging of equine ovarian follicles and corpora lutea.
The Veterinary clinics of North America. Equine practice    August 1, 1988   Volume 4, Issue 2 197-213 doi: 10.1016/s0749-0739(17)30636-3
Ginther OJ.One of the most profound theriogenology applications of transrectal diagnostic ultrasonography in mares involves the imaging of ovarian follicles and corpora lutea. The resolving capabilities (frequency) and quality of the scanner directly affect the minimal size of a structure that can be imaged and the quality of the image. High-frequency scanners (5 or 7.5 MHz) of good quality can image a 2-mm follicle and the corpus luteum throughout its functional life. A low-frequency scanner (3 or 3.5 MHz) can image a 6-mm follicle and the corpus luteum for several days after ovulation. Equine follicles...
Quantification of skin displacement near the carpal, tarsal and fetlock joints of the walking horse.
Equine veterinary journal    May 1, 1988   Volume 20, Issue 3 203-208 doi: 10.1111/j.2042-3306.1988.tb01500.x
van Weeren PR, van den Bogert AJ, Barneveld A.A technique enabling simultaneous visualisation of skin and underlying bony structures in the walking horse was used to quantify skin displacements on the lateral surface of carpal, tarsal and fetlock joints. The technique employed implanted light-emitting-diodes (LEDs) for marking the bone, and self adhesive spot labels for marking the overlying skin. Photographic recordings were made. Skin displacement was measured in six Dutch Warmblood horses. Mean total displacements and mean displacement per degree of change of joint angle were calculated. Displacements at the level of the fetlock joints...
[The diagnostic value of the ‘skyline’ view for the radiographic study of the navicular bone in horses].
Tijdschrift voor diergeneeskunde    March 1, 1988   Volume 113, Issue 5 260-269 
Zweers AD, Dik KJ.The radiographic diagnostic value of Rose's palmaroproximal-dorsodistal ('skyline') projection and Oxspring's dorsopalmar projection of the equine navicular bone were compared, by examining radiographs of 102 navicular bones originating from 66 randomly selected horses with clinical evidence of lameness located in the navicular area. In 27 navicular bones essential information was obtained from the skyline view, 15 independently of Oxspring's projection and 12 in addition to this view. For 11 navicular studies the D.P. projection was the most important diagnostic view. In the other 64 navicula...
Incomplete linear tibial fractures in two horses.
Journal of the American Veterinary Medical Association    February 15, 1988   Volume 192, Issue 4 522-524 
Johnson PJ, Allhands RV, Baker GJ, Boero MJ, Foreman JH, Hyyppa T, Huhn JC.Incomplete linear tibial fractures were identified in two horses with the aid of scintigraphy. Both horses were treated successfully by strict stall confinement, and both returned to normal athletic activity. Scintigraphy can be used to facilitate the generally difficult diagnosis of incomplete tibial fractures.
Effect of dorsopalmar projection obliquity on radiographic measurement of distal phalangeal rotation angle in horses with laminitis.
Journal of the American Veterinary Medical Association    February 1, 1988   Volume 192, Issue 3 346-349 
Koblik PD, O'Brien TR, Coyne CP.The effect of dorsopalmar projection obliquity on calculation of distal phalangeal rotation (DPR) angle was determined in 8 feet obtained from 5 horses that had been euthanatized because of laminitis. A true lateromedial view of each foot served as a reference, with additional views taken at 5, 10, 15, and 20 degrees of x-ray tube head rotation in both a dorsal and in a palmar direction. Projection obliquity resulted in consistent underestimation of DPR angle. Where projection obliquity exceeded 10 degrees, there were significant (P less than 0.05) differences in DPR angle. The magnitude of un...
Detection by computed tomography of occult osteochondral defects in the fetlock of a horse.
Equine veterinary journal    November 1, 1987   Volume 19, Issue 6 556-558 doi: 10.1111/j.2042-3306.1987.tb02673.x
Barbee DD, Allen JR, Grant BD, Riggs MW, Crawley GR, Sande RD.No abstract available
1 30 31 32 33 34 36