Inertial Measurement Units (IMUs) are electronic devices that measure and report a horse's specific force, angular rate, and sometimes the magnetic field surrounding the body. These units are used in equine studies to assess and analyze movement patterns, gait, and biomechanical performance. IMUs typically consist of accelerometers, gyroscopes, and sometimes magnetometers, allowing for detailed data collection in various equestrian activities. The application of IMUs in horses provides valuable insights into locomotion and can aid in the assessment of lameness, training regimens, and rehabilitation processes. This page compiles peer-reviewed research studies and scholarly articles that explore the utilization, accuracy, and applications of inertial measurement units in equine movement analysis.
Kallerud AS, Marques-Smith P, Bendiksen HK, Fjordbakk CT.A markerless artificial intelligence (AI) system for lameness detection has recently become available but has not been extensively compared with commonly used inertial measurement unit (IMU) systems for detecting asymmetry under field conditions. Objective: Comparison of classification of asymmetric limbs under field conditions and comparison of normalised asymmetry data using a markerless AI system (SleipAI; recorded on a tripod mounted iPhone 14pro [SL]); the Equinosis Q Lameness Locator (LL); the EquiMoves (EM); and subjective evaluation (SE). Methods: Descriptive clinical study. Methods: S...
Pfau T, Landsbergen K, Davis BL, Kenny O, Kernot N, Rochard N, Porte-Proust M, Sparks H, Takahashi Y, Toth K, Scott WM.With an increasing number of systems for quantifying lameness-related movement asymmetry, between-system comparisons under non-laboratory conditions are important for multi-centre or referral-level studies. This study compares an artificial intelligence video app to a validated inertial measurement unit (IMU) gait analysis system in a specific group of horses. Methods: Twenty-two reining Quarter horses were equipped with nine body-mounted IMUs while being videoed with a smartphone app. Both systems quantified head and pelvic movement symmetry during in-hand trot (hard/soft ground) and on the l...
Guyard KC, Montavon S, Bertolaccini J, Deriaz M.Quantitative information on how well a horse clears a jump has great potential to support the rider in improving the horse's jumping performance. This study investigated the validation of a GPS-based inertial measurement unit, namely Alogo Move Pro, compared with a traditional optical motion capture system. Accuracy and precision of the three jumping characteristics of maximum height (Zmax), stride/jump length (lhorz), and mean horizontal speed (vhorz) were compared. Eleven horse-rider pairs repeated two identical jumps (an upright and an oxer fence) several times ( = 6 to 10) at different hei...
Pasquiet B, Biau S, Trébot Q, Debril JF, Durand F, Fradet L.Detecting fatigue during training sessions would help riders and trainers to optimize their training. It has been shown that fatigue could affect movement patterns. Inertial measurement units (IMUs) are wearable sensors that measure linear accelerations and angular velocities, and can also provide orientation estimates. These sensors offer the possibility of a non-invasive and continuous monitoring of locomotion during training sessions. However, the indicators extracted from IMUs and their ability to show these locomotion changes are not known. The present study aims at defining which kinemat...
Mao A, Huang E, Gan H, Parkes RSV, Xu W, Liu K.With the recent advances in deep learning, wearable sensors have increasingly been used in automated animal activity recognition. However, there are two major challenges in improving recognition performance-multi-modal feature fusion and imbalanced data modeling. In this study, to improve classification performance for equine activities while tackling these two challenges, we developed a cross-modality interaction network (CMI-Net) involving a dual convolution neural network architecture and a cross-modality interaction module (CMIM). The CMIM adaptively recalibrated the temporal- and axis-wis...
Serra Bragança FM, Broomé S, Rhodin M, Björnsdóttir S, Gunnarsson V, Voskamp JP, Persson-Sjodin E, Back W, Lindgren G, Novoa-Bravo M, Gmel AI....No abstract available
Tijssen M, Hernlund E, Rhodin M, Bosch S, Voskamp JP, Nielen M, Serra Braganςa FM.For gait classification, hoof-on and hoof-off events are fundamental locomotion characteristics of interest. These events can be measured with inertial measurement units (IMUs) which measure the acceleration and angular velocity in three directions. The aim of this study was to present two algorithms for automatic detection of hoof-events from the acceleration and angular velocity signals measured by hoof-mounted IMUs in walk and trot on a hard surface. Seven Warmblood horses were equipped with two wireless IMUs, which were attached to the lateral wall of the right front (RF) and hind (RH) hoo...
Tijssen M, Hernlund E, Rhodin M, Bosch S, Voskamp JP, Nielen M, Serra Braganςa FM.A prolonged break-over phase might be an indication of a variety of musculoskeletal disorders and can be measured with optical motion capture (OMC) systems, inertial measurement units (IMUs) and force plates. The aim of this study was to present two algorithms for automatic detection of the break-over phase onset from the acceleration and angular velocity signals measured by hoof-mounted IMUs in walk and trot on a hard surface. The performance of these algorithms was evaluated by internal validation with an OMC system and a force plate separately. Seven Warmblood horses were equipped with two ...
Bosch S, Serra Bragança F, Marin-Perianu M, Marin-Perianu R, van der Zwaag BJ, Voskamp J, Back W, van Weeren R, Havinga P.In this paper, we describe and validate the EquiMoves system, which aims to support equine veterinarians in assessing lameness and gait performance in horses. The system works by capturing horse motion from up to eight synchronized wireless inertial measurement units. It can be used in various equine gait modes, and analyzes both upper-body and limb movements. The validation against an optical motion capture system is based on a Bland-Altman analysis that illustrates the agreement between the two systems. The sagittal kinematic results (protraction, retraction, and sagittal range of motion) sh...
Bragança FM, Bosch S, Voskamp JP, Marin-Perianu M, Van der Zwaag BJ, Vernooij JCM, van Weeren PR, Back W.Inertial measurement unit (IMU) sensor-based techniques are becoming more popular in horses as a tool for objective locomotor assessment. Objective: To describe, evaluate and validate a method of stride detection and quantification at walk and trot using distal limb mounted IMU sensors. Methods: Prospective validation study comparing IMU sensors and motion capture with force plate data. Methods: A total of seven Warmblood horses equipped with metacarpal/metatarsal IMU sensors and reflective markers for motion capture were hand walked and trotted over a force plate. Using four custom built algo...
Pfau T, Weller R.Equine inertial measurement unit (IMU) gait analysis has gained in popularity for use in horses. Similar transducers are now found in consumer grade smartphones. However, to date there are no scientific data evaluating their use for assessment of movement (a)symmetry in the horse. Objective: To establish limits of agreement (LoA, mean difference ±2 s.d.) between a validated specialist IMU system and IMU data collected with a consumer grade smartphone for quantification of movement symmetry and range of motion (ROM) of pelvic movement in the trotting horse. Methods: Method comparison study bas...
Moorman VJ, Reiser RF, Mahaffey CA, Peterson ML, McIlwraith CW, Kawcak CE.To determine intralimb orientation changes with an inertial measurement unit (IMU) in hooves of horses at a walk and trot after induction of weight-bearing single forelimb lameness and to determine whether hoof orientations are similar to baseline values following perineural anesthesia. Methods: 6 clinically normal horses. Methods: 3-D hoof orientations were determined with an IMU mounted on the right forelimb hoof during baseline conditions, during 3 grades of lameness (induced by application of pressure to the sole), and after perineural anesthesia. Linear acceleration profiles were used to ...
Olsen E, Pfau T, Ritz C.Over ground motion analysis in horses is limited by a small number of strides and restraints of the indoor gait laboratory. Inertial measurement units (IMUs) are transforming the knowledge of human motion and objective clinical assessment through the opportunity to obtain clinically relevant data under various conditions. When using IMUs on the limbs of horses to determine local position estimates, conditions with high dynamic range of both accelerations and rotational velocities prove particularly challenging. Here we apply traditional method agreement and suggest a novel method of functional...
Olsen E, Andersen PH, Pfau T.The increased variations of temporal gait events when pathology is present are good candidate features for objective diagnostic tests. We hypothesised that the gait events hoof-on/off and stance can be detected accurately and precisely using features from trunk and distal limb-mounted Inertial Measurement Units (IMUs). Four IMUs were mounted on the distal limb and five IMUs were attached to the skin over the dorsal spinous processes at the withers, fourth lumbar vertebrae and sacrum as well as left and right tuber coxae. IMU data were synchronised to a force plate array and a motion capture sy...
Bosch S, Serra Bragança F, Marin-Perianu M, Marin-Perianu R, van der Zwaag BJ, Voskamp J, Back W, van Weeren R, Havinga P.In this paper, we describe and validate the EquiMoves system, which aims to support equine veterinarians in assessing lameness and gait performance in horses. The system works by capturing horse motion from up to eight synchronized wireless inertial measurement units. It can be used in various equine gait modes, and analyzes both upper-body and limb movements. The validation against an optical motion capture system is based on a Bland-Altman analysis that illustrates the agreement between the two systems. The sagittal kinematic results (protraction, retraction, and sagittal range of motion) sh...
Bragança FM, Bosch S, Voskamp JP, Marin-Perianu M, Van der Zwaag BJ, Vernooij JCM, van Weeren PR, Back W.Inertial measurement unit (IMU) sensor-based techniques are becoming more popular in horses as a tool for objective locomotor assessment. Objective: To describe, evaluate and validate a method of stride detection and quantification at walk and trot using distal limb mounted IMU sensors. Methods: Prospective validation study comparing IMU sensors and motion capture with force plate data. Methods: A total of seven Warmblood horses equipped with metacarpal/metatarsal IMU sensors and reflective markers for motion capture were hand walked and trotted over a force plate. Using four custom built algo...
Olsen E, Andersen PH, Pfau T.The increased variations of temporal gait events when pathology is present are good candidate features for objective diagnostic tests. We hypothesised that the gait events hoof-on/off and stance can be detected accurately and precisely using features from trunk and distal limb-mounted Inertial Measurement Units (IMUs). Four IMUs were mounted on the distal limb and five IMUs were attached to the skin over the dorsal spinous processes at the withers, fourth lumbar vertebrae and sacrum as well as left and right tuber coxae. IMU data were synchronised to a force plate array and a motion capture sy...
Pfau T, Weller R.Equine inertial measurement unit (IMU) gait analysis has gained in popularity for use in horses. Similar transducers are now found in consumer grade smartphones. However, to date there are no scientific data evaluating their use for assessment of movement (a)symmetry in the horse. Objective: To establish limits of agreement (LoA, mean difference ±2 s.d.) between a validated specialist IMU system and IMU data collected with a consumer grade smartphone for quantification of movement symmetry and range of motion (ROM) of pelvic movement in the trotting horse. Methods: Method comparison study bas...
Tijssen M, Hernlund E, Rhodin M, Bosch S, Voskamp JP, Nielen M, Serra Braganςa FM.For gait classification, hoof-on and hoof-off events are fundamental locomotion characteristics of interest. These events can be measured with inertial measurement units (IMUs) which measure the acceleration and angular velocity in three directions. The aim of this study was to present two algorithms for automatic detection of hoof-events from the acceleration and angular velocity signals measured by hoof-mounted IMUs in walk and trot on a hard surface. Seven Warmblood horses were equipped with two wireless IMUs, which were attached to the lateral wall of the right front (RF) and hind (RH) hoo...
Mao A, Huang E, Gan H, Parkes RSV, Xu W, Liu K.With the recent advances in deep learning, wearable sensors have increasingly been used in automated animal activity recognition. However, there are two major challenges in improving recognition performance-multi-modal feature fusion and imbalanced data modeling. In this study, to improve classification performance for equine activities while tackling these two challenges, we developed a cross-modality interaction network (CMI-Net) involving a dual convolution neural network architecture and a cross-modality interaction module (CMIM). The CMIM adaptively recalibrated the temporal- and axis-wis...
Olsen E, Pfau T, Ritz C.Over ground motion analysis in horses is limited by a small number of strides and restraints of the indoor gait laboratory. Inertial measurement units (IMUs) are transforming the knowledge of human motion and objective clinical assessment through the opportunity to obtain clinically relevant data under various conditions. When using IMUs on the limbs of horses to determine local position estimates, conditions with high dynamic range of both accelerations and rotational velocities prove particularly challenging. Here we apply traditional method agreement and suggest a novel method of functional...
Moorman VJ, Reiser RF, Mahaffey CA, Peterson ML, McIlwraith CW, Kawcak CE.To determine intralimb orientation changes with an inertial measurement unit (IMU) in hooves of horses at a walk and trot after induction of weight-bearing single forelimb lameness and to determine whether hoof orientations are similar to baseline values following perineural anesthesia. Methods: 6 clinically normal horses. Methods: 3-D hoof orientations were determined with an IMU mounted on the right forelimb hoof during baseline conditions, during 3 grades of lameness (induced by application of pressure to the sole), and after perineural anesthesia. Linear acceleration profiles were used to ...
Pasquiet B, Biau S, Trébot Q, Debril JF, Durand F, Fradet L.Detecting fatigue during training sessions would help riders and trainers to optimize their training. It has been shown that fatigue could affect movement patterns. Inertial measurement units (IMUs) are wearable sensors that measure linear accelerations and angular velocities, and can also provide orientation estimates. These sensors offer the possibility of a non-invasive and continuous monitoring of locomotion during training sessions. However, the indicators extracted from IMUs and their ability to show these locomotion changes are not known. The present study aims at defining which kinemat...
Guyard KC, Montavon S, Bertolaccini J, Deriaz M.Quantitative information on how well a horse clears a jump has great potential to support the rider in improving the horse's jumping performance. This study investigated the validation of a GPS-based inertial measurement unit, namely Alogo Move Pro, compared with a traditional optical motion capture system. Accuracy and precision of the three jumping characteristics of maximum height (Zmax), stride/jump length (lhorz), and mean horizontal speed (vhorz) were compared. Eleven horse-rider pairs repeated two identical jumps (an upright and an oxer fence) several times ( = 6 to 10) at different hei...
Serra Bragança FM, Broomé S, Rhodin M, Björnsdóttir S, Gunnarsson V, Voskamp JP, Persson-Sjodin E, Back W, Lindgren G, Novoa-Bravo M, Gmel AI....No abstract available
Tijssen M, Hernlund E, Rhodin M, Bosch S, Voskamp JP, Nielen M, Serra Braganςa FM.A prolonged break-over phase might be an indication of a variety of musculoskeletal disorders and can be measured with optical motion capture (OMC) systems, inertial measurement units (IMUs) and force plates. The aim of this study was to present two algorithms for automatic detection of the break-over phase onset from the acceleration and angular velocity signals measured by hoof-mounted IMUs in walk and trot on a hard surface. The performance of these algorithms was evaluated by internal validation with an OMC system and a force plate separately. Seven Warmblood horses were equipped with two ...
Pfau T, Landsbergen K, Davis BL, Kenny O, Kernot N, Rochard N, Porte-Proust M, Sparks H, Takahashi Y, Toth K, Scott WM.With an increasing number of systems for quantifying lameness-related movement asymmetry, between-system comparisons under non-laboratory conditions are important for multi-centre or referral-level studies. This study compares an artificial intelligence video app to a validated inertial measurement unit (IMU) gait analysis system in a specific group of horses. Methods: Twenty-two reining Quarter horses were equipped with nine body-mounted IMUs while being videoed with a smartphone app. Both systems quantified head and pelvic movement symmetry during in-hand trot (hard/soft ground) and on the l...
Kallerud AS, Marques-Smith P, Bendiksen HK, Fjordbakk CT.A markerless artificial intelligence (AI) system for lameness detection has recently become available but has not been extensively compared with commonly used inertial measurement unit (IMU) systems for detecting asymmetry under field conditions. Objective: Comparison of classification of asymmetric limbs under field conditions and comparison of normalised asymmetry data using a markerless AI system (SleipAI; recorded on a tripod mounted iPhone 14pro [SL]); the Equinosis Q Lameness Locator (LL); the EquiMoves (EM); and subjective evaluation (SE). Methods: Descriptive clinical study. Methods: S...