Analyze Diet

Topic:Measurement Techniques

Measurement techniques in horses encompass various methods and tools used to assess and quantify different physiological, anatomical, and biomechanical parameters in equine studies. These techniques are employed to gather data on aspects such as body condition, gait analysis, heart rate, and respiratory function, among others. Common measurement techniques include the use of thermography for detecting temperature variations, ultrasonography for imaging soft tissues, and force plates for analyzing gait dynamics. These methods provide valuable information for understanding equine health, performance, and biomechanics. This page compiles peer-reviewed research studies and scholarly articles that explore the application, accuracy, and reliability of measurement techniques in equine research.
Some factors affecting the accuracy and variability of measurements of the height of ponies.
The Veterinary record    May 22, 2007   Volume 160, Issue 20 691-694 doi: 10.1136/vr.160.20.691
Lamas LP, Giovagnoli G, Heath MF, Jeffcott LB.Height is the only factor used to differentiate horses and ponies for competitive purposes; any horse without shoes that is less than 148 cm at the highest point of the withers can be classified as a pony. However, variations in height associated with anatomical and other factors can occur. In this study the accuracy of the most commonly used measuring procedure and seven independent factors that might affect apparent height were evaluated in skeletally mature horses that were less than 155 cm in height. The results indicated that there was an improvement of 57 per cent in the accuracy of meas...
A comparison of three-dimensional ultrasound, two-dimensional ultrasound and dissections for determination of lesion volume in tendons.
Ultrasound in medicine & biology    June 21, 2006   Volume 32, Issue 6 797-804 doi: 10.1016/j.ultrasmedbio.2006.02.1418
Ferrari M, Weller R, Pfau T, Payne RC, Wilson AM.The purpose of this work was to evaluate the accuracy and precision of a freehand three-dimensional (3-D) ultrasonography system in the determination of lesion volume in tendons. The accuracy and precision of a 3-D ultrasonography system was assessed by performing repeated measurements on a phantom of known volume. Volume measurements of tendon lesions performed with 3-D ultrasonography were compared with measurements based on a series of two-dimensional (2-D) ultrasound (US) scans and to direct measurements from dissections. A novel method for the creation of tendon lesions in vitro was devel...
Skeletal muscle blood flow in anaesthetized horses. Part I: measurement techniques.
Veterinary anaesthesia and analgesia    November 22, 2005   Volume 32, Issue 6 324-330 doi: 10.1111/j.1467-2995.2005.00191.x
Raisis AL.The objective of this review was to describe the methodology and limitations of techniques that have been used to measure skeletal muscle blood flow in anaesthetized horses. Methods: Pubmed, personal files. Conclusions: Numerous techniques have been used in horses to study skeletal muscle blood flow during anaesthesia and after the administration of vasoactive agents. Of the available techniques, blood flow measurements are limited to either microvascular flow (radioactive xenon, laser Doppler flowmetry) or total blood flow (radioactive microspheres, electromagnetic flowmetry, Doppler ultrason...
Development and testing of a modular strain measurement clip.
Journal of biomechanics    October 3, 2003   Volume 36, Issue 11 1669-1674 doi: 10.1016/s0021-9290(03)00173-8
Whan G, Phillips J, Bullock S, Runciman RJ, Pearce S, Hurtig M.A novel, multi-use, low-stiffness and low-cost transducer for measuring in vitro strains has been developed and tested. Currently available strain measurement methods are either too expensive, too complicated or too inflexible for multi-use strain measurement. The stainless-steel modular strain measurement clip introduced here was instrumented with four 350 Omega axial strain gauges in a full Wheatstone bridge configuration to take advantage of commonly available strain gauge amplifier equipment. Adjustable extension arms were designed to allow greater application versatility. The clip was cal...
Comparison of Body Temperatures of Goats, Horses, and Sheep Measured With a Tympanic Infrared Thermometer, an Implantable Microchip Transponder, and a Rectal Thermometer.
Contemporary topics in laboratory animal science    November 29, 2002   Volume 37, Issue 3 51-55 
Goodwin S.Body temperature of goats, horses, and sheep was measured, using 3 methods. Tympanic temperature was measured with a tympanic infrared thermometer, subcutaneous temperature was measured with an implantable microchip transponder, and rectal temperature was measured with a digital thermometer. For goats, rectal and subcutaneous temperatures were significantly higher than tympanic temperatures, but rectal and subcutaneous temperatures did not differ significantly. For horses and sheep, rectal temperatures were significantly higher than tympanic and subcutaneous temperatures, and tympanic temperat...
Use of height-specific weigh tapes to estimate the bodyweight of horses.
The Veterinary record    June 6, 2002   Volume 150, Issue 20 632-634 doi: 10.1136/vr.150.20.632
Ellis JM, Hollands T.Two thousand horses of different ages, heights and breeds were divided into two height groups of up to 14.2 hands high (hh) and more than 14.2 hh, and weighed on a weighbridge; each horse then had its weight estimated by three weigh tapes, one height specific (tape 1 or 2, depending on the animal's height) and two for general use (tapes 3 and 4). For horses up to 14.2 hh, weigh tape 1 provided the most accurate estimate of mean (sd) bodyweight (100.5 [6.2] per cent), and weigh tapes 3 and 4 were 112 (6.8) and 97-0 (6.1) per cent accurate, respectively. For horses more than 14.2 hh, weigh tape ...
Ultrasound-spirometry and capnography in horses: analysis of measurement reliability.
Veterinary research communications    March 13, 2001   Volume 25, Issue 2 137-147 doi: 10.1023/a:1006409003122
Herholz C, Straub R, Busato A.Ultrasound-spirometry and capnography and the evaluation of corresponding 'single-breath diagrams for CO2' (SBD-CO2) is a relatively new, non-invasive method for assessing pulmonary function in horses. The relative variation and the reliability of observations within measurement sessions were calculated for expiratory tidal volume, for expired CO2 volume (%) and for the phase II and phase III slopes of the SBD-CO2 in horses without pulmonary disease and in horses suffering from differing degrees of chronic obstructive pulmonary disease. The coefficient of variation of expiratory tidal volume r...
Repeatability of diagnostic ultrasonography in the assessment of the equine superficial digital flexor tendon.
Equine veterinary journal    February 24, 2001   Volume 33, Issue 1 33-37 doi: 10.2746/042516401776767494
Pickersgill CH, Marr CM, Reid SW.A quantitative investigation of the variation that can occur during the course of ultrasonography of the equine superficial digital flexor tendons (SDFT) was undertaken. The aim of this investigation was to use an objective measure, namely the measurement of CSA, to quantify the variability occurring during the course of the ultrasonographic assessment of the equine SDFT. The effects of 3 variables on the CSA measurements were determined. 1) Image acquisition operator (IAc): two different operators undertaking the ultrasonographic examination; 2) image analysis operator (IAn): two different op...
Measuring sphere-like structures using transrectal ultrasonography. Löfstedt RM, Ireland WP.Sphere-like structures are commonly measured for clinical or research purposes. We measured two diameters, the circumference (perimeter) and cross sectional area of 113 equine ovarian follicles in a water bath then determined the relationships between those measurements and the actual volume of fluid in the follicles. Cross-sectional area, diameter3 and area2/3 were all highly correlated with the volume of the structures and superior (p 0.05) between cross-sectional area, diameter3, and area2/3. Because of the ease of measuring diameter, we suggest that diameter3 be used to estimate the actua...
Accuracy of different methods of estimating the weight of horses.
The Veterinary record    October 31, 1998   Volume 143, Issue 12 335-336 doi: 10.1136/vr.143.12.335
Ellis JM, Hollands T.Six hundred horses of different ages, heights and breeds were weighed on a weighbridge and had their weights estimated by two weigh tapes, 1 and 2, by a formula, and by a visual estimate. For the population as a whole, the most accurate method was the formula (mean [sd] 98.6 [10.6] per cent) closely followed by weigh tape 2 (98.1 [8.1] per cent). Tape 1 and the visual estimate were the least accurate (112.0 [9.3] and 88.3 [20.1] per cent respectively). When the population was divided into two height groups, the formula and weigh tape 2 were the most accurate for horses or = 15 hh weigh tape 1...
Measurement of cardiac function by transthoracic echocardiography: day to day variability and repeatability in normal Thoroughbred horses.
Equine veterinary journal    April 16, 1998   Volume 30, Issue 2 117-122 doi: 10.1111/j.2042-3306.1998.tb04470.x
Young LE, Scott GR.In order to assess the reliability and repeatability of transthoracic echocardiography for detecting serial changes in cardiac function in horses, day to day variability of a number of echocardiographic indices of ventricular function were studied. The variables investigated were, from 2-dimensional (2-D) and M-mode echocardiography - aortic diameter in systole (Aos), pulmonary artery diameter in systole (Pas), left ventricular internal diameter in systole (LLVIDs) and diastole (LLVIDd), and left ventricular fractional shortening (%FS) and estimated ejection fraction (EF). From pulsed Doppler ...
Linear assessment of the thoroughbred horse: an approach to conformation evaluation.
Equine veterinary journal    November 1, 1996   Volume 28, Issue 6 461-467 doi: 10.1111/j.2042-3306.1996.tb01618.x
Mawdsley A, Kelly EP, Smith FH, Brophy PO.A linear assessment trait evaluation system is proposed to allow quantitative description of the static conformation of the horse. Measurements were made on 27 selected traits. The system was tested initially for repeatability of measurements on 4 horses. Twenty-one of the selected traits were satisfactory and 6 proved unsatisfactory in terms of reproducibility. A population of 101, superior 2- and 3-year-old Thoroughbreds and 19 premium Thoroughbred stallions were similarly assessed. More than 65% of the traits exhibited large (CV > 10%) phenotypic variation within the sampled population. ...
Echocardiographic measurements of cardiac dimensions and indices of cardiac function in normal adult thoroughbred horses.
Equine veterinary journal. Supplement    September 1, 1995   Issue 19 18-27 doi: 10.1111/j.2042-3306.1995.tb04985.x
Patteson MW, Gibbs C, Wotton PR, Cripps PJ.Cardiac dimensions and indices of cardiac function were measured in 29 clinically normal adult Thoroughbreds (TB) which performed minimal exercise using guided M-mode and two-dimensional (2-D) echocardiography, from a variety of image planes and measurement methods, and standardised imaging planes based on intracardiac anatomical landmarks. The different methods of measuring these variables were compared. The variables which were considered to be most valuable for quantitative echocardiography were measured in a further 9 horses. Comparable measurements of cardiac dimensions can be obtained fr...
Novel force transducer for the measurement of tendon force in vivo.
Journal of biomechanics    December 1, 1994   Volume 27, Issue 12 1489-1493 doi: 10.1016/0021-9290(94)90198-8
Platt D, Wilson AM, Timbs A, Wright IM, Goodship AE.No abstract available
Concept of a force-measuring horseshoe.
Acta anatomica    January 1, 1993   Volume 146, Issue 2-3 114-119 doi: 10.1159/000147431
Roepstorff L, Drevemo S.To further develop objective methods in the field of gait analysis a force-measuring horseshoe (FM shoe) has been developed. The ground reaction forces were determined by measuring the degree of displacement between the two solid parts of the shoe. This was done by three removable measuring units (MUs) that were equipped with strain gauges and placed in the toe and in each of the quarter parts. Before performing force recordings the sensors were calibrated with the actual MUs mounted on the shoe. This can be done in the field with a specially developed equipment. The shape of the signal genera...
Measurement of cardiac dimensions with two-dimensional echocardiography in the living horse.
Equine veterinary journal    November 1, 1991   Volume 23, Issue 6 461-465 doi: 10.1111/j.2042-3306.1991.tb03762.x
Voros K, Holmes JR, Gibbs C.Two-dimensional echocardiography (2DE) was performed on 22 unsedated Thoroughbred and part Thoroughbred horses weighing between 411 and 650 kg to establish normal reference values for 2DE measurements. Animals stood during examinations performed with a 3.5 MHz mechanical sector transducer using various transducer positions and tomographic planes. Right ventricular diameter (RVD), ventricular septal thickness (VSTh), aortic diameter (AoD), area of the chordal lumen of the left ventricle (CTA), left ventricular diameter (LVD) and left atrial diameter (LAD) were determined at ventricular end-dias...
Evaluation of measures taken by ultrasonography and caliper to estimate testicular volume and predict daily sperm output in the stallion.
Journal of reproduction and fertility. Supplement    January 1, 1991   Volume 44 99-105 
Love CC, Garcia MC, Riera FR, Kenney RM.The semen of 26 stallions, 2-20 years of age, was collected once a day for 7 consecutive days to determine daily sperm output (DSO). After the last collection, 17 stallions were castrated. Testicular volume was estimated using two methods. Length, width, height, of each testis were measured by caliper. Length, width, height, cross-sectional area and circumference at the widest point of the testis were measured by ultrasonography. Both caliper and ultrasound measurements were first made in the live animal, and again in vitro. There were no differences in these measurements because of method or ...
Accuracy of formulae for calculating left ventricular volumes of the equine heart.
Equine veterinary journal. Supplement    June 1, 1990   Issue 9 53-56 doi: 10.1111/j.2042-3306.1990.tb04735.x
Lord PF, Croft MA.Echocardiography may be an accurate method of measuring left ventricular (LV) volumes and mass of the horse's heart. If so, studies of the heart size and hypertrophy would be possible. This study evaluated geometric models of the external and internal LV shapes, to determine which could be applied to echocardiographic measurements. We preserved 30 horses' hearts and measured their dimensions and cross sectional areas. These measurements were entered into seven formulae representing different geometric models of the ventricle and its chamber. We derived a correction factor to estimate the long ...
The relationship of frog pressure to heel expansion.
Equine veterinary journal    January 1, 1989   Volume 21, Issue 1 13-16 doi: 10.1111/j.2042-3306.1989.tb02082.x
Colles CM.A study was carried out on five horses and four ponies to assess the effect of altering frog pressure on hoof expansion. Measurements of hoof expansion were made using strain gauges. It was concluded that whereas frog pressure affects hoof expansion, it is only one of several factors. Increasing frog pressure may result in increased expansion, or contraction, or may have virtually no affect. The variable results of changing frog pressure should be taken into account when considering therapeutic shoeing.
A technique for assessing hoof function in the horse.
Equine veterinary journal    January 1, 1989   Volume 21, Issue 1 17-22 doi: 10.1111/j.2042-3306.1989.tb02083.x
Colles CM.This paper describes the application of foil strain gauges to the hoof wall, and the use of measuring equipment to monitor weightbearing and changes in hoof shape in shod and unshod horses. It concludes that the systems can detect hoof movement and that results are reproducible. It is also concluded that the use of a conventional nailed on iron shoe restricts flexion and spreading of the hoof wall at the ground surface, but has little effect on the degree of expansion of the heels of the foot.
Body condition scoring and weight estimation of horses.
Equine veterinary journal    January 1, 1988   Volume 20, Issue 1 41-45 doi: 10.1111/j.2042-3306.1988.tb01451.x
Carroll CL, Huntington PJ.Three hundred and seventy two horses of varying breeds, height and fatness were weighed and measured for height at the withers. They were assessed for condition score by adaptation of a previously published method. The heart girth and length of 281 of the horses were also measured. Weight of horses was highly correlated (P less than 0.001) with height (r2 = 0.62), condition score (r2 = 0.22) and girth2 x length (r2 = 0.90). Nomograms were constructed to predict weight from height and condition score, and girth and length measurements. Weight can also be accurately estimated from the formula: (...
Comparison of echocardiographic and autopsy measurements of cardiac dimensions in the horse.
Equine veterinary journal    September 1, 1985   Volume 17, Issue 5 361-368 doi: 10.1111/j.2042-3306.1985.tb02522.x
O'Callaghan MW.This study was initiated to determine the accuracy of M-mode echocardiography in measuring left ventricular dimensions and estimating heart weights in horses. Left ventricular free wall and interventricular septal thickness and left ventricular external and internal diameters were measured and heart weights estimated from the echocardiograms of 47 horses. Autopsy measurements of the same parameters were then recorded. Statistical comparison of the data demonstrated: (1) Systolic measurements of wall thickness more closely resembled the heart in death than the diastolic measurements; (2) good c...
Measurement of horses.
The Veterinary record    May 19, 1984   Volume 114, Issue 20 491-493 doi: 10.1136/vr.114.20.491
Hickman J, Colles C.No abstract available
Factors affecting measurement of horses and ponies.
The Veterinary record    May 19, 1984   Volume 114, Issue 20 485 doi: 10.1136/vr.114.20.485
No abstract available
Joint measurement scheme.
The Veterinary record    February 11, 1984   Volume 114, Issue 6 150 doi: 10.1136/vr.114.6.150-b
Hull PN.No abstract available
An indirect method for measurement of systemic blood pressure in animals.
Nihon juigaku zasshi. The Japanese journal of veterinary science    June 1, 1976   Volume 38, Issue 03 305-308 doi: 10.1292/jvms1939.38.305
Sawazaki H, Hirose H.No abstract available
Letter: In vivo tendon tension and bone strain measurement and correlation.
Journal of biomechanics    January 1, 1975   Volume 8, Issue 1 87-88 doi: 10.1016/0021-9290(75)90047-0
Salmons S.No abstract available
In vivo tendon tension and bone strain measurement and correlation.
Journal of biomechanics    January 1, 1974   Volume 7, Issue 1 35-42 doi: 10.1016/0021-9290(74)90068-2
Barnes GR, Pinder DN.No abstract available
Direct measurement of left ventricular ejection time and ejection time index in the domestic pony.
American journal of veterinary research    August 1, 1972   Volume 33, Issue 8 1569-1574 
Amend JF, Garner HE, Rosborough JP, Hoff HE.No abstract available
Impact force measurement using preloaded transducers.
American journal of veterinary research    December 1, 1970   Volume 31, Issue 12 2279-2283 
Frederick FH, Henderson JM.No abstract available