Measurement techniques in horses encompass various methods and tools used to assess and quantify different physiological, anatomical, and biomechanical parameters in equine studies. These techniques are employed to gather data on aspects such as body condition, gait analysis, heart rate, and respiratory function, among others. Common measurement techniques include the use of thermography for detecting temperature variations, ultrasonography for imaging soft tissues, and force plates for analyzing gait dynamics. These methods provide valuable information for understanding equine health, performance, and biomechanics. This page compiles peer-reviewed research studies and scholarly articles that explore the application, accuracy, and reliability of measurement techniques in equine research.
Grimwood K, Lancaster B, Handel I.Accurate measurement of equine body weight is important for evaluating medication dosages and feed quantities. Different methods exist for measuring body weight, including weigh tapes (WT), though accuracy varies. Measurements could be affected by external variables, such as time of day, human error, or uneven surfaces, and also horse-based variables, such as height and body condition score (BCS). The aim of this study was to investigate how different horse-based variables affect WT reading. A retrospective analysis was performed using anonymised data from feed company nutrition consultations ...
Blanco MA, Di Rado FN, Peterson MM.Turfgrass in equine sports has clear advantages over other types of reinforcement but adds complexity to the management. This study investigates factors that influence the turfgrass' surface performance and how the use of a drainage package and a geotextile reinforcement affect quantitative measurements of turfgrass. The measurements are made using affordable, lightweight testing tools that are readily available or easily constructed. Eight boxes with turfgrass over a mix of the arena with peat at a consistent depth were tested for volumetric moisture content (VMC %) with time-domain reflectom...
Angeluci GC, Ricci CL, Passareli JVGC, Estanho GJG, Oliveira AS, Santos SGA, Giuffrida R, Rodrigues M, Andrade SF.Measurement of the intraocular pressure (IOP) is a useful diagnostic tool in equine ophthalmology. Handheld tonometers, such as Tonovet and Tonovet Plus (rebound), Tono-Pen AVIA Vet (applanation), and Kowa HA-2 (applanation using the Goldmann methodology) are used to obtain IOP measurements in veterinary medicine. Objective: To compare and evaluate the accuracy of four handheld tonometers in measuring IOP using different methodologies in healthy horses. Methods: In vivo experiment and cross-sectional survey of healthy horses. Methods: Intraocular pressure was measured in 72 eyes of 36 horses. ...
Sellke L, Patan-Zugaj B, Ludewig E, Cimrman R, Witter K.Different measuring techniques have been used to objectify the classification of hoof shape. The MicroScribe is a novel tool that might prove useful for measuring hooves without prior reconstruction or compensation of projection artefacts. The aim of this study was to compare biometric data of the equine hoof collected by the MicroScribe tool and measurements collected directly from hooves, scaled photographs and radiographs, from photogrammetry models and computed tomography datasets. The suitability of MicroScribe generated data to differentiate individual hoof conformations was tested. A to...
Shahkhosravi NA, Son J, Davies HMS, Komeili A.Equine hoof conformation is integral to equine performance and soundness. Consequently, it is a major area of interest within the field of equine health. Researchers have measured several hoof shape parameters to study the hoof conformation. Proximal hoof circumference (PHC) is a primary hoof shape parameter, and its assessment may help to recognize the early stages of the development of changes in hoof morphology or poor hoof shape. Previous studies have mainly used a measuring tape to measure PHC. However, some doubts still exist regarding the reliability, repeatability and accuracy of measu...
Bolt DM, Carrier ME, Sheridan KS, Manso-Diaz G, Berner D.Foot imbalance and malalignment of the digits are common in horses. Angle and distance measurements performed on bones, joints and hoof wall on radiographs provide essential guidance for precise corrective trimming and shoeing. This study aimed to investigate, if selected standing low-field magnetic resonance (MR) images can be used to accurately measure dorsopalmar and lateromedial foot conformation parameters in comparison to the radiographic gold standard. Images of 100 horses referred for standing low-field MR examination were selected. Foot conformation angles and distances were measured ...
Heun F, Böing L, Theunert J, Gasse H.This basically anatomical study focuses on two items; firstly, the establishment of a system for the cartographic subdivision of the neopallium; secondly, the topographical correlation of extracranial landmarks and intracranial sites on the neopallium. Methods: The surface of the neopallium was subdivided into 15 sectors with reference to a newly introduced pattern of Primary Sulci. The topographical link between extracranial landmarks and certain intracranial sites (i.e. neopallium sectors) was elaborated by using a simple stereotactic device and a computer-assisted measurement device. Measur...
Olusa TAO, Ismail SMY, Murray CM, Davies HMS.Carpal conformation is often considered as a contributory factor to performance and lameness in the horse; however, few attempts have been made to objectively measure radiographic variations of carpal conformation in horses due to insufficient measurable carpal parameters. This pilot study used carpal radiographic images acquired from 10 cadaveric equine forelimbs transected at the antebrachial midshaft from 7 adult horses (7.2 ± 2.6 years), positioned at 'zero lateromedial' (ZLM) and 'zero dorsopalmar' (ZDP) views, to investigate the anatomy of the equine carpus and develop parameters tha...
Górniak W, Wieliczko M, Soroko M, Korczyński M.Methods of estimating horse body weight using mathematical formulae have better accuracy than methods of reading body weight from measuring tape. The aim of the study was to evaluate established formulae for estimating horse body weight from data gathered using measurement tape. The research was conducted in a group of 299 adult horses and ponies of selected breeds: ponies ( = 58), Polish Noble Half Breed ( = 150), Silesian Breed ( = 23), Wielkopolski Breed ( = 52), and Thoroughbred ( = 16). Body measurements were performed on each horse using a measuring stick and tape. The actual body weight...
Nieth J, Krohn J.Aim of the study was to describe the echotexture and dimensions of the kidneys including the renal pelvis in neonatal foals using transabdominal sonography. Methods: In the course of a preliminary examination, sonographic examinations of the kidneys of 10 dead newborn foals were performed in order to determine their localization, measurement parameters, and echotexture. In subsequent necropsies, the kidneys were measured and the obtained values were compared with the sonographic measurements. A high level of agreement between the both measurement values could be demonstrated. In the main exami...
Vera L, De Clercq D, Paulussen E, Van Steenkiste G, Decloedt A, Chiers K, van Loon G.In human medicine, local and regional arterial wall stiffness (AWS) parameters are routinely used to assess the vascular health. In horses, information regarding reproducibility of ultrasonographically derived AWS parameters is lacking. Objective: To evaluate the inter-day and inter-observer and intra-observer measurement variability of both local and regional AWS parameters in horses. Methods: Experimental study. Methods: In 10 healthy, adult Warmblood horses, B-, M-mode and pulsed-wave Doppler ultrasound images were collected on two different days from aorta, cranial and caudal common caroti...
Quaresma M, Bacellar D, Leiva B, Silva SR.The use of the measurement of heart girth (HG), in locations where a scale is not available, with the application of weight estimation formulas or special weight tapes, is well established as a practical and accurate way to estimate the live weight (LW). Although several studies were performed to correlate donkey body measurements and LW, none of these was done in the large frame European donkey breeds. When using smaller frame breeds formulas, the tendency was to underestimate the live weight of larger frame breeds. The sample used in this study consisted of 65 Miranda breed donkeys, with age...
Peli A, Roccaro M.Catastrophic injuries in racehorses mostly involve the metacarpal region. Although many studies describe fractures of equine limbs, few examine the relationship between bone morphometrics and musculoskeletal problems in racing horses. And yet, according to the regulation of some Italian traditional races, the shin circumference represents a qualifying prerequisite for horses to be admitted to races. This study aims to evaluate the conformity of the shin circumference measurement in living animals and in post‑mortem examinations, in order to evaluate the forensic reliability of these measurem...
Hine L, Laven RA, Sahu SK.To compare the variation in rectal temperature measurement by digital, mercury and ethanol thermometers in cattle, horses and sheep. Methods: Seven different makes of thermometer (four digital, two mercury, and one ethanol; (n=27) were tested individually in a calibrated water bath to identify whether there was an effect of thermometer make on recorded temperature. In addition, rectal temperatures of four cattle, four sheep and four horses were recorded using the same thermometers, by seven persons, with each person being assigned to one thermometer make. Results: In the water bath test, mean ...
Lee H, Kirkland WG, Whitmore RN, Theis KM, Young HE, Richardson AJ, Jackson RL, Hanson RR.Thicknesses of fresh equine articular cartilage surfaces from the fetlock, carpal and stifle joints were measured employing a needle probe test. Methods: Eighty-seven samples used in measurement were cultivated from fetlock, carpal and stifle joints of 12 deceased within 4 h of death. After approximately three minutes of exposure to air during dissection, all cartilage samples were preserved in a saline solution to keep the articular cartilage hydrated for testing. The thickness was measured on five different spots on the same sample. The thicknesses of the fetlock, carpus and stifle were co...
Couppé C, Svensson RB, Sødring-Elbrønd V, Hansen P, Kjaer M, Magnusson SP.Magnetic resonance imaging (MRI) has commonly been applied to determine tendon cross-sectional area (CSA) and length either to measure structural changes or to normalize mechanical measurements to stress and strain. The ability to reproduce CSA measurements on MRI images has been reported, but the accuracy in relation to actual tendon dimensions has never been investigated. The purpose of this study was to compare tendon CSA measured by MRI with that measured in vitro with the mould casting technique. The knee of a horse was MRI-scanned with 1.5 and 3 tesla, and two examiners measured the pate...
Holden-Douilly L, Pourcelot P, Desquilbet L, Falala S, Crevier-Denoix N, Chateau H.Longitudinal sliding of horse's hooves at the beginning of stance can affect both performance and orthopaedic health. The objective of this study was to compare two measurement methods for quantifying hoof slip distances at training trot. The right front hoof of four French Trotters was equipped with an accelerometer (10 kHz) and kinematic markers. A firm wet sand track was equipped with a 50 m calibration corridor. A high-frequency camera (600 Hz) was mounted in a vehicle following each horse trotting at about 7 m/s. One of the horses was also trotted on raw dirt and harrowed dirt tracks. Lon...
Westermann S, Buchner HH, Schramel JP, Tichy A, Stanek C.To assess effects of camera angle and distance on measurement and reproducibility of thermographically determined temperatures of the distolateral aspect of the forelimbs in horses. Methods: Evaluation study. Methods: 10 adult horses. Methods: Thermographic images of both forelimbs were obtained at 3 times during the day (replicates 1, 2, and 3); maximum surface temperature over 1 region (distolateral aspect of the third metacarpal bone and metacarpophalangeal joint) was measured. Standard images were obtained every 5 minutes for 1 hour with the camera positioned at an angle of 90° and a dist...
Zauscher JM, Estrada R, Edinger J, Lischer CJ.To evaluate intra- and interobserver variability in ultrasonographic measurements of the proximal aspect of the suspensory ligament (PSL) in the horse. Objective: A minimum difference of ≥20% is required to differentiate reliably between physiological and pathological alterations related to dimensions. Methods: Two operators examined the PSL in all 4 limbs of 14 horses twice using different techniques and different probes with and without standoff pads. Measurements were taken from the longitudinal and transverse images. Inter- and intraoperator variability was evaluated using agreement indi...
Oosterlinck M, Pille F, Sonneveld DC, Oomen AM, Gasthuys F, Back W.The aim of this study was to evaluate the accuracy of the vertical force curve of a pressure plate (PP) using dynamic calibration with a force plate (FP) in six sound Warmblood horses. The animals were walked and trotted over a combined PP-FP system sampling at 250 Hz. Five valid measurements of each forelimb were collected. The recalibration factor (RF), the ratio between the calibrated and raw PP data, was evaluated in each timeframe throughout the stance phase. Following dynamic calibration, the vertical force curve of the PP demonstrated a characteristic biphasic pattern at the walk and ty...
Draper AC, Bowen IM, Hallowell GD.The aims of this study were to establish a normal reference range (mean ± 2 SD) and assess reliability of renal dimensions obtained using transabdominal ultrasonography in Thoroughbred horses (n = 7). A minimum of three ultrasonographic cineloops were obtained from each intercostal space and the left paralumbar fossa by two observers daily for three consecutive days. Renal length, width, and thickness and cortex, medulla, and pelvic dimensions were obtained. Measurements were undertaken by both observers, who were unaware of prior measurements, to assess reproducibility and measured on three ...
Borioni N, Marinaro P, Celestini S, Del Sole F, Magro R, Zoppi D, Mattei F, Dall' Armi V, Mazzarella F, Cesario A, Bonassi S.To assess the effects of equestrian rehabilitation (ER) and onotherapy (Ono) on physical and psycho-social performances of subjects affected by intellectual disability (ID), and to develop a measurement tool based on the International Classification of Functioning Disability and Health-Children and Youth (ICF-CY). Methods: A tool based on the ICF-CY classification was designed to evaluate subjects undergoing equine rehabilitation within a bio-psychosocial approach. A simplified version of this evaluation form was developed for the equestrian instructors. The agreement between the two tools was...
Norton JL, Nolen-Walston RD, Underwood C, Boston R, Slack J, Dallap BL.Central venous pressure (CVP) is a used as an estimation of intravascular volume status in various species. Techniques for measuring CVP in horses have been described, but the repeatability of these readings at a single time point or over time has not been established. Objective: That CVP measurements in healthy adult horses would be repeatable at each time point, that these readings would be reproducible over time, and that alteration in head position relative to the heart would alter CVP. Methods: Ten healthy adult research horses. Methods: In an experimental study, horses were instrumented ...
Vergari C, Pourcelot P, Holden L, Ravary-Plumioën B, Laugier P, Mitton D, Crevier-Denoix N.Measure of the cross-sectional area (CSA) of biological specimens is a primary concern for many biomechanical tests. Different procedures are presented in literature but besides the fact that noncontact techniques are required during mechanical testing, most of these procedures lack accuracy or speed. Moreover, they often require a precise positioning of the specimen, which is not always feasible, and do not enable the measure of the same section during tension. The objective of this study was to design a noncontact, fast, and accurate device capable of acquiring CSA of specimens mounted on a ...
Scrivani PV, Levine JM, Holmes NL, Furr M, Divers TJ, Cohen ND.Different examiners or the same examiner were observed at different times producing slightly different results when obtaining cervical-vertebral ratios. If the difference is substantial, then measurement variability would have an important impact of radiographic interpretation. Objective: To quantify agreement and repeatability of these measurements. Methods: An observer agreement study was performed using 75 horses. Measurements were made at C3-4 and C6-7 by a board-certified radiologist and an imaging resident. Intra- and interobserver agreement was quantified using Bland-Altman plots. Repea...
Curtis GC, Grove-White D, Ellis RN, Argo CM.Standard and modified measuring sticks were used to record height at the withers and a 'non-contact' laser was used to measure withers and loin heights. Sixty horses and ponies, ranging in height (115 to 155 cm) and body condition score (BCS) (moderate to obese) were measured by each method at 10-minute intervals for 40 minutes. Measurement series were repeated over three successive days. Unique regression models were constructed for method-specific data. Coefficients of variation were similar for stick and laser methods (0.002 to 0.004 per cent). Models were not influenced by day of measureme...
Carstens A, Kirberger RM, Grimbeek RJ, Donnellan CM, Saulez MN.Radiographic measurement of tracheal dimensions in the horse may be useful in evaluating upper and lower respiratory tract conditions due to the gradient of pressure changes between these areas. Lateral radiographs of the trachea of 15 normal sedated Thoroughbred horses were made at inspiration and expiration and magnification-corrected mean airway heights measured were, respectively: larynx: 5.89 and 5.86 cm; trachea at the third cervical vertebra (C3): 4.17 and 4.04cm; at the fifth cervical vertebra (C5): 3.62 and 3.59 cm; at the first thoracic vertebra (T1): 3.4 and 3.23cm; and carina: 3.85...
Oosterlinck M, Pille F, Back W, Dewulf J, Gasthuys F.Subtle lameness in horses may be difficult to diagnose and methods to evaluate lameness objectively are useful when equine clinicians fail to reach a consensus. The aim of this study was to determine whether equine pressure plate measurements are repeatable when used to calculate forelimb loading (peak vertical pressure [PVP], peak vertical force [PVF], vertical impulse [VI]) and symmetry ratios, and to establish if these data are similar to the 'gold standard' force plate values. Since plate dimensions are relatively small, ponies were used to enable recordings to be taken from both forelimbs...
Kleijn WM, Sloet van Oldruitenborgh-Oosterbaan MM.Measuring the height of ponies at the withers is currently a prerequisite at Fédération Equestre Internationale (FEI) competitions. A pony measured at a competition site must not measure more than 151 cm with, or 150 cm without horse shoes. When a pony exceeds the regulated height, it is excluded from participation in the competition. Moreover, the sale value of a pony can decrease dramatically if by height measurement it is designated as a 'horse'. The aim of this study was firstly to determine whether measuring ponies at the withers with a laser device is repeatable; secondly, to evaluate ...
Carroll CL, Huntington PJ.Three hundred and seventy two horses of varying breeds, height and fatness were weighed and measured for height at the withers. They were assessed for condition score by adaptation of a previously published method. The heart girth and length of 281 of the horses were also measured. Weight of horses was highly correlated (P less than 0.001) with height (r2 = 0.62), condition score (r2 = 0.22) and girth2 x length (r2 = 0.90). Nomograms were constructed to predict weight from height and condition score, and girth and length measurements. Weight can also be accurately estimated from the formula: (...
Goodwin S.Body temperature of goats, horses, and sheep was measured, using 3 methods. Tympanic temperature was measured with a tympanic infrared thermometer, subcutaneous temperature was measured with an implantable microchip transponder, and rectal temperature was measured with a digital thermometer. For goats, rectal and subcutaneous temperatures were significantly higher than tympanic temperatures, but rectal and subcutaneous temperatures did not differ significantly. For horses and sheep, rectal temperatures were significantly higher than tympanic and subcutaneous temperatures, and tympanic temperat...
Borioni N, Marinaro P, Celestini S, Del Sole F, Magro R, Zoppi D, Mattei F, Dall' Armi V, Mazzarella F, Cesario A, Bonassi S.To assess the effects of equestrian rehabilitation (ER) and onotherapy (Ono) on physical and psycho-social performances of subjects affected by intellectual disability (ID), and to develop a measurement tool based on the International Classification of Functioning Disability and Health-Children and Youth (ICF-CY). Methods: A tool based on the ICF-CY classification was designed to evaluate subjects undergoing equine rehabilitation within a bio-psychosocial approach. A simplified version of this evaluation form was developed for the equestrian instructors. The agreement between the two tools was...
Oosterlinck M, Pille F, Back W, Dewulf J, Gasthuys F.Subtle lameness in horses may be difficult to diagnose and methods to evaluate lameness objectively are useful when equine clinicians fail to reach a consensus. The aim of this study was to determine whether equine pressure plate measurements are repeatable when used to calculate forelimb loading (peak vertical pressure [PVP], peak vertical force [PVF], vertical impulse [VI]) and symmetry ratios, and to establish if these data are similar to the 'gold standard' force plate values. Since plate dimensions are relatively small, ponies were used to enable recordings to be taken from both forelimbs...
Pickersgill CH, Marr CM, Reid SW.A quantitative investigation of the variation that can occur during the course of ultrasonography of the equine superficial digital flexor tendons (SDFT) was undertaken. The aim of this investigation was to use an objective measure, namely the measurement of CSA, to quantify the variability occurring during the course of the ultrasonographic assessment of the equine SDFT. The effects of 3 variables on the CSA measurements were determined. 1) Image acquisition operator (IAc): two different operators undertaking the ultrasonographic examination; 2) image analysis operator (IAn): two different op...
Patteson MW, Gibbs C, Wotton PR, Cripps PJ.Cardiac dimensions and indices of cardiac function were measured in 29 clinically normal adult Thoroughbreds (TB) which performed minimal exercise using guided M-mode and two-dimensional (2-D) echocardiography, from a variety of image planes and measurement methods, and standardised imaging planes based on intracardiac anatomical landmarks. The different methods of measuring these variables were compared. The variables which were considered to be most valuable for quantitative echocardiography were measured in a further 9 horses. Comparable measurements of cardiac dimensions can be obtained fr...
Couppé C, Svensson RB, Sødring-Elbrønd V, Hansen P, Kjaer M, Magnusson SP.Magnetic resonance imaging (MRI) has commonly been applied to determine tendon cross-sectional area (CSA) and length either to measure structural changes or to normalize mechanical measurements to stress and strain. The ability to reproduce CSA measurements on MRI images has been reported, but the accuracy in relation to actual tendon dimensions has never been investigated. The purpose of this study was to compare tendon CSA measured by MRI with that measured in vitro with the mould casting technique. The knee of a horse was MRI-scanned with 1.5 and 3 tesla, and two examiners measured the pate...
Mawdsley A, Kelly EP, Smith FH, Brophy PO.A linear assessment trait evaluation system is proposed to allow quantitative description of the static conformation of the horse. Measurements were made on 27 selected traits. The system was tested initially for repeatability of measurements on 4 horses. Twenty-one of the selected traits were satisfactory and 6 proved unsatisfactory in terms of reproducibility. A population of 101, superior 2- and 3-year-old Thoroughbreds and 19 premium Thoroughbred stallions were similarly assessed. More than 65% of the traits exhibited large (CV > 10%) phenotypic variation within the sampled population. ...
Love CC, Garcia MC, Riera FR, Kenney RM.The semen of 26 stallions, 2-20 years of age, was collected once a day for 7 consecutive days to determine daily sperm output (DSO). After the last collection, 17 stallions were castrated. Testicular volume was estimated using two methods. Length, width, height, of each testis were measured by caliper. Length, width, height, cross-sectional area and circumference at the widest point of the testis were measured by ultrasonography. Both caliper and ultrasound measurements were first made in the live animal, and again in vitro. There were no differences in these measurements because of method or ...
Westermann S, Buchner HH, Schramel JP, Tichy A, Stanek C.To assess effects of camera angle and distance on measurement and reproducibility of thermographically determined temperatures of the distolateral aspect of the forelimbs in horses. Methods: Evaluation study. Methods: 10 adult horses. Methods: Thermographic images of both forelimbs were obtained at 3 times during the day (replicates 1, 2, and 3); maximum surface temperature over 1 region (distolateral aspect of the third metacarpal bone and metacarpophalangeal joint) was measured. Standard images were obtained every 5 minutes for 1 hour with the camera positioned at an angle of 90° and a dist...
Lee H, Kirkland WG, Whitmore RN, Theis KM, Young HE, Richardson AJ, Jackson RL, Hanson RR.Thicknesses of fresh equine articular cartilage surfaces from the fetlock, carpal and stifle joints were measured employing a needle probe test. Methods: Eighty-seven samples used in measurement were cultivated from fetlock, carpal and stifle joints of 12 deceased within 4 h of death. After approximately three minutes of exposure to air during dissection, all cartilage samples were preserved in a saline solution to keep the articular cartilage hydrated for testing. The thickness was measured on five different spots on the same sample. The thicknesses of the fetlock, carpus and stifle were co...
Ellis JM, Hollands T.Six hundred horses of different ages, heights and breeds were weighed on a weighbridge and had their weights estimated by two weigh tapes, 1 and 2, by a formula, and by a visual estimate. For the population as a whole, the most accurate method was the formula (mean [sd] 98.6 [10.6] per cent) closely followed by weigh tape 2 (98.1 [8.1] per cent). Tape 1 and the visual estimate were the least accurate (112.0 [9.3] and 88.3 [20.1] per cent respectively). When the population was divided into two height groups, the formula and weigh tape 2 were the most accurate for horses or = 15 hh weigh tape 1...
Vergari C, Pourcelot P, Holden L, Ravary-Plumioën B, Laugier P, Mitton D, Crevier-Denoix N.Measure of the cross-sectional area (CSA) of biological specimens is a primary concern for many biomechanical tests. Different procedures are presented in literature but besides the fact that noncontact techniques are required during mechanical testing, most of these procedures lack accuracy or speed. Moreover, they often require a precise positioning of the specimen, which is not always feasible, and do not enable the measure of the same section during tension. The objective of this study was to design a noncontact, fast, and accurate device capable of acquiring CSA of specimens mounted on a ...
Holden-Douilly L, Pourcelot P, Desquilbet L, Falala S, Crevier-Denoix N, Chateau H.Longitudinal sliding of horse's hooves at the beginning of stance can affect both performance and orthopaedic health. The objective of this study was to compare two measurement methods for quantifying hoof slip distances at training trot. The right front hoof of four French Trotters was equipped with an accelerometer (10 kHz) and kinematic markers. A firm wet sand track was equipped with a 50 m calibration corridor. A high-frequency camera (600 Hz) was mounted in a vehicle following each horse trotting at about 7 m/s. One of the horses was also trotted on raw dirt and harrowed dirt tracks. Lon...
Angeluci GC, Ricci CL, Passareli JVGC, Estanho GJG, Oliveira AS, Santos SGA, Giuffrida R, Rodrigues M, Andrade SF.Measurement of the intraocular pressure (IOP) is a useful diagnostic tool in equine ophthalmology. Handheld tonometers, such as Tonovet and Tonovet Plus (rebound), Tono-Pen AVIA Vet (applanation), and Kowa HA-2 (applanation using the Goldmann methodology) are used to obtain IOP measurements in veterinary medicine. Objective: To compare and evaluate the accuracy of four handheld tonometers in measuring IOP using different methodologies in healthy horses. Methods: In vivo experiment and cross-sectional survey of healthy horses. Methods: Intraocular pressure was measured in 72 eyes of 36 horses. ...
Scrivani PV, Levine JM, Holmes NL, Furr M, Divers TJ, Cohen ND.Different examiners or the same examiner were observed at different times producing slightly different results when obtaining cervical-vertebral ratios. If the difference is substantial, then measurement variability would have an important impact of radiographic interpretation. Objective: To quantify agreement and repeatability of these measurements. Methods: An observer agreement study was performed using 75 horses. Measurements were made at C3-4 and C6-7 by a board-certified radiologist and an imaging resident. Intra- and interobserver agreement was quantified using Bland-Altman plots. Repea...
Young LE, Scott GR.In order to assess the reliability and repeatability of transthoracic echocardiography for detecting serial changes in cardiac function in horses, day to day variability of a number of echocardiographic indices of ventricular function were studied. The variables investigated were, from 2-dimensional (2-D) and M-mode echocardiography - aortic diameter in systole (Aos), pulmonary artery diameter in systole (Pas), left ventricular internal diameter in systole (LLVIDs) and diastole (LLVIDd), and left ventricular fractional shortening (%FS) and estimated ejection fraction (EF). From pulsed Doppler ...
Górniak W, Wieliczko M, Soroko M, Korczyński M.Methods of estimating horse body weight using mathematical formulae have better accuracy than methods of reading body weight from measuring tape. The aim of the study was to evaluate established formulae for estimating horse body weight from data gathered using measurement tape. The research was conducted in a group of 299 adult horses and ponies of selected breeds: ponies ( = 58), Polish Noble Half Breed ( = 150), Silesian Breed ( = 23), Wielkopolski Breed ( = 52), and Thoroughbred ( = 16). Body measurements were performed on each horse using a measuring stick and tape. The actual body weight...
Draper AC, Bowen IM, Hallowell GD.The aims of this study were to establish a normal reference range (mean ± 2 SD) and assess reliability of renal dimensions obtained using transabdominal ultrasonography in Thoroughbred horses (n = 7). A minimum of three ultrasonographic cineloops were obtained from each intercostal space and the left paralumbar fossa by two observers daily for three consecutive days. Renal length, width, and thickness and cortex, medulla, and pelvic dimensions were obtained. Measurements were undertaken by both observers, who were unaware of prior measurements, to assess reproducibility and measured on three ...
Quaresma M, Bacellar D, Leiva B, Silva SR.The use of the measurement of heart girth (HG), in locations where a scale is not available, with the application of weight estimation formulas or special weight tapes, is well established as a practical and accurate way to estimate the live weight (LW). Although several studies were performed to correlate donkey body measurements and LW, none of these was done in the large frame European donkey breeds. When using smaller frame breeds formulas, the tendency was to underestimate the live weight of larger frame breeds. The sample used in this study consisted of 65 Miranda breed donkeys, with age...
Oosterlinck M, Pille F, Sonneveld DC, Oomen AM, Gasthuys F, Back W.The aim of this study was to evaluate the accuracy of the vertical force curve of a pressure plate (PP) using dynamic calibration with a force plate (FP) in six sound Warmblood horses. The animals were walked and trotted over a combined PP-FP system sampling at 250 Hz. Five valid measurements of each forelimb were collected. The recalibration factor (RF), the ratio between the calibrated and raw PP data, was evaluated in each timeframe throughout the stance phase. Following dynamic calibration, the vertical force curve of the PP demonstrated a characteristic biphasic pattern at the walk and ty...
Hine L, Laven RA, Sahu SK.To compare the variation in rectal temperature measurement by digital, mercury and ethanol thermometers in cattle, horses and sheep. Methods: Seven different makes of thermometer (four digital, two mercury, and one ethanol; (n=27) were tested individually in a calibrated water bath to identify whether there was an effect of thermometer make on recorded temperature. In addition, rectal temperatures of four cattle, four sheep and four horses were recorded using the same thermometers, by seven persons, with each person being assigned to one thermometer make. Results: In the water bath test, mean ...
Carstens A, Kirberger RM, Grimbeek RJ, Donnellan CM, Saulez MN.Radiographic measurement of tracheal dimensions in the horse may be useful in evaluating upper and lower respiratory tract conditions due to the gradient of pressure changes between these areas. Lateral radiographs of the trachea of 15 normal sedated Thoroughbred horses were made at inspiration and expiration and magnification-corrected mean airway heights measured were, respectively: larynx: 5.89 and 5.86 cm; trachea at the third cervical vertebra (C3): 4.17 and 4.04cm; at the fifth cervical vertebra (C5): 3.62 and 3.59 cm; at the first thoracic vertebra (T1): 3.4 and 3.23cm; and carina: 3.85...
Ferrari M, Weller R, Pfau T, Payne RC, Wilson AM.The purpose of this work was to evaluate the accuracy and precision of a freehand three-dimensional (3-D) ultrasonography system in the determination of lesion volume in tendons. The accuracy and precision of a 3-D ultrasonography system was assessed by performing repeated measurements on a phantom of known volume. Volume measurements of tendon lesions performed with 3-D ultrasonography were compared with measurements based on a series of two-dimensional (2-D) ultrasound (US) scans and to direct measurements from dissections. A novel method for the creation of tendon lesions in vitro was devel...
Voros K, Holmes JR, Gibbs C.Two-dimensional echocardiography (2DE) was performed on 22 unsedated Thoroughbred and part Thoroughbred horses weighing between 411 and 650 kg to establish normal reference values for 2DE measurements. Animals stood during examinations performed with a 3.5 MHz mechanical sector transducer using various transducer positions and tomographic planes. Right ventricular diameter (RVD), ventricular septal thickness (VSTh), aortic diameter (AoD), area of the chordal lumen of the left ventricle (CTA), left ventricular diameter (LVD) and left atrial diameter (LAD) were determined at ventricular end-dias...
Sellke L, Patan-Zugaj B, Ludewig E, Cimrman R, Witter K.Different measuring techniques have been used to objectify the classification of hoof shape. The MicroScribe is a novel tool that might prove useful for measuring hooves without prior reconstruction or compensation of projection artefacts. The aim of this study was to compare biometric data of the equine hoof collected by the MicroScribe tool and measurements collected directly from hooves, scaled photographs and radiographs, from photogrammetry models and computed tomography datasets. The suitability of MicroScribe generated data to differentiate individual hoof conformations was tested. A to...
Herholz C, Straub R, Busato A.Ultrasound-spirometry and capnography and the evaluation of corresponding 'single-breath diagrams for CO2' (SBD-CO2) is a relatively new, non-invasive method for assessing pulmonary function in horses. The relative variation and the reliability of observations within measurement sessions were calculated for expiratory tidal volume, for expired CO2 volume (%) and for the phase II and phase III slopes of the SBD-CO2 in horses without pulmonary disease and in horses suffering from differing degrees of chronic obstructive pulmonary disease. The coefficient of variation of expiratory tidal volume r...
O'Callaghan MW.This study was initiated to determine the accuracy of M-mode echocardiography in measuring left ventricular dimensions and estimating heart weights in horses. Left ventricular free wall and interventricular septal thickness and left ventricular external and internal diameters were measured and heart weights estimated from the echocardiograms of 47 horses. Autopsy measurements of the same parameters were then recorded. Statistical comparison of the data demonstrated: (1) Systolic measurements of wall thickness more closely resembled the heart in death than the diastolic measurements; (2) good c...