Echocardiography is a diagnostic imaging technique used to assess the heart's structure and function in horses. It utilizes ultrasound waves to create detailed images of the heart, allowing veterinarians to evaluate cardiac anatomy, blood flow, and heart motion. Echocardiography is instrumental in diagnosing various cardiac conditions, such as valvular disorders, congenital heart defects, and myocardial diseases in equine patients. The procedure provides valuable information on heart size, wall thickness, and chamber dimensions. This page compiles peer-reviewed research studies and scholarly articles that explore the methodologies, applications, and clinical implications of echocardiography in equine cardiology.
Marr CM, Love S, Pirie HM, Northridge DB.Regurgitation of blood through the left atrioventricular valve owing to the rupture of one of the chordae tendineae of the valve was diagnosed in a horse with sudden-onset respiratory distress and a holosystolic cardiac murmur. Severe regurgitation was confirmed with Doppler echocardiography and prolapse of part of the valve leaflet was identified with B-mode ultrasonography. The rupture of one of the chordae tendineae of a right accessory cusp of the left atrioventricular valve was confirmed post mortem. Bronchiolitis, multifocal haemorrhages and haemorrhagic fibrous plaques were found in the...
Reef VB, Klumpp S, Maxson AD, Sweeney RW.Two-dimensional real-time echocardiographic examination of a 3-year-old Thoroughbred gelding with pleuropneumonia revealed an intact aneurysm of the right sinus of Valsalva, which was confirmed at postmortem examination. The horse had no clinical signs associated with the aneurysm.
Lord PF, Croft MA.Echocardiography may be an accurate method of measuring left ventricular (LV) volumes and mass of the horse's heart. If so, studies of the heart size and hypertrophy would be possible. This study evaluated geometric models of the external and internal LV shapes, to determine which could be applied to echocardiographic measurements. We preserved 30 horses' hearts and measured their dimensions and cross sectional areas. These measurements were entered into seven formulae representing different geometric models of the ventricle and its chamber. We derived a correction factor to estimate the long ...
Reef VB, Lalezari K, De Boo J, van der Belt AJ, Spencer PA, Dik KJ.Pulsed-wave Doppler echocardiography was performed on 30 clinically normal 1- to 6-year-old racing Standardbreds. There were 13 females, 13 geldings, and 4 stallions. Cardiac disease was not detected with M-mode, 2-dimensional real-time or pulsed-wave Doppler echocardiography. Normal flow velocities for right and left atrial outflow, right and left ventricular outflow, the aorta, and pulmonary artery were determined. Peak flow velocities for right and left atrial outflow occurred during the rapid filling phase and were higher toward the mitral valve (mean, 0.70 +/- 0.24 m/s) than toward the tr...
Dedrick P, Reef VB, Sweeney RW, Morris DD.Using echocardiography, mitral valve bacterial endocarditis was diagnosed in a yearling Thoroughbred filly with a history of periodic fever and intermittent hind limb lameness. Streptococcus sp were isolated from blood, and the filly was treated with penicillin, resulting in a bacteriologic cure. Severe mitral regurgitation developed secondary to scarring of the valve, which resulted in the filly's death. A poor prognosis usually is indicated in horses with bacterial endocarditis, as bacteriologic cures are infrequent and severe valvular insufficiency often develops.
Bertone JJ, Paull KS, Wingfield WE, Boon JA.M-mode echocardiographic structures, and cardiac function indices, PCV, and total plasma protein values were determined for 34 endurance equine athletes before (base line) and after (after race) a 161-km endurance competition and were compared. The PCV (base-line mean, 37%; after-race mean, 46%) and total plasma protein value (base-line mean, 6.9 g/dl; after-race mean, 7.5 g/dl) increased. Compared with base-line echocardiography, after-race echocardiography indicated an increase in heart rate, as determined from the simultaneous ECG recorded on the echocardiograph (base-line mean, 41 beats/mi...
Clark ES, Reef VB, Sweeney CR, Lichtensteiger C.Aortic insufficiency was suspected in a thin 1-year-old colt with a grade IV/V decrescendo holodiastolic murmur and a bounding arterial pulse. Echocardiographic findings (diastolic fluttering of the septal leaflet of the mitral valve, left ventricular volume overload, and incomplete aortic valve closure) were diagnostic for aortic valve insufficiency. Moderately thick fibrotic aortic valve leaflets were found at necropsy. Fenestrations were found in the aortic and pulmonic valve cusps. Congenital valvular disease may have led to aortic valvular insufficiency in this horse.
Reef VB.Mitral valvular insufficiency associated with ruptured chordae tendineae was diagnosed in 3 foals with signs of congestive heart failure, which were believed to be secondary to the development of pulmonary hypertension associated with the valvular insufficiency. The septal leaflet of the mitral valve was affected in all 3 foals, and foal 2 also had ruptured chordae tendineae associated with the caudal mitral valve leaflet. Bacterial endocarditis and myocardial necrosis were associated with the ruptured chordae tendineae in foals 3 and 2, respectively. Idiopathic rupture was considered in foal ...
Reef VB, Mann PC, Orsini PG.M-mode, 2-dimensional, and contrast echocardiographic studies were used to detect tricuspid atresia in 2 foals. M-mode echocardiographic findings included a small right ventricle, large left ventricle, large mitral valve excursion, large left atrium (foal 2), dropout of the cranial aspect of the aortic root, and a thick band of echoes in the tricuspid valve region. These findings were confirmed by 2-dimensional echocardiography. In addition, a large right atrium, persistent foramen ovale, ventricular septal defect, and large mitral valve apparatus were imaged. One foal also had a thick right a...
Reef VB, Spencer P.Echocardiographic evaluation of 23 horses with aortic insufficiency was performed, using M-mode (n = 23) and 2-dimensional real-time echocardiography (n = 14 of 23). Echocardiograms were evaluated for abnormalities of aortic and mitral valves and alterations in motion of these valves. Changes in left ventricular chamber size and function, as well as aortic root size, were evaluated. The presence of other cardiac disease was also evaluated. Horses with aortic insufficiency had significant increases (P less than 0.01) in mean values of left ventricular chamber size, aortic root diameter, and sho...
Freestone JF, Thomas WP, Carlson GP, Brumbaugh GW.Pericarditis and pericardial effusion are considered to occur rarely in the horse. The clinical and laboratory features of idiopathic pericarditis with effusion diagnosed in 10 horses over a seven-year period were reviewed. Consistent physical findings included tachycardia, ventral oedema, jugular venous distention and diminished heart sounds. Electrocardiographic features included diminished voltages and electrical alternans, and the effusion was identified by echocardiography in the six horses in which it was performed. Pericardiocentesis relieved clinical signs in nine horses. Laboratory an...
Reef VB, Clark ES, Oliver JA, Donawick WJ.A permanent, transvenous, atrioventricular, sequential pacing system was implanted successfully in a 7-year-old Quarter Horse gelding with complete heart block. The transvenous atrial and ventricular electrodes were placed in their respective positions in the heart, using real-time, 2-dimensional echocardiography. The horse was able to return successfully to competition as a show horse.
Roby KA, Reef VB, Shaw DP, Sweeney CR.A 15-year-old, Standardbred broodmare with an aortic sinus aneurysm developed rupture of the aneurysm with subsequent rupture of a tricuspid valve chorda tendinae, tricuspid regurgitation, acute right-sided congestive heart failure, and pulmonary thromboembolism. Shunting of blood from the aorta through the ruptured aneurysm into the right ventricle resulted in decreased renal perfusion and acute renal failure. Initially, treatment of the mare with analgesics, fluids, and digoxin resulted in clinical improvement, but the mare's condition deteriorated after 8 days and the mare was euthanatized ...
Pipers FS, Reef V, Wilson J.Ventricular septal defects in a foal, a 2-year-old filly, and 2 calves were demonstrated with M-mode and two-dimensional real-time echocardiography. The studies were performed with the animals unsedated, either standing or in lateral recumbency. Cardiac windows were located between the 4th and 7th intercostal spaces, approximately at the level of the olecranon. In each case, the septal defect was visualized high in the membranous portion of the interventricular septum. Defects were visualized by use of sector scanning or linear-array ultrasonic equipment, with transducer frequencies of 2.25 to...
Kvart C, Carlsten J, Jeffcott LB, Nilsfors L.M-mode echocardiography is a safe and practical means of using ultrasound to evaluate the dynamic movements of cardiac structures. The technique can be refined by using a simple contrast medium in the form of carbon dioxide mixed with heparinised blood to provide a strong echogenic result. This technique was employed in a series of 15 normal conscious standing horses and in three animals with specific cardiac defects. In the clinical cases it was possible to confirm the diagnosis and differentiate between a congenital septal defect and mitral regurgitation. The method was found to be safe and ...
O'Callaghan MW.This study was initiated to determine the accuracy of M-mode echocardiography in measuring left ventricular dimensions and estimating heart weights in horses. Left ventricular free wall and interventricular septal thickness and left ventricular external and internal diameters were measured and heart weights estimated from the echocardiograms of 47 horses. Autopsy measurements of the same parameters were then recorded. Statistical comparison of the data demonstrated: (1) Systolic measurements of wall thickness more closely resembled the heart in death than the diastolic measurements; (2) good c...
Bonagura JD, Herring DS, Welker F.Diagnostic ultrasound permits the clinician to image the beating heart, quantitate cardiac dimensions, identify specific congenital and acquired cardiac lesions, and estimate the degree of cardiac compensation and muscle failure that accompanies a specific lesion. The M-mode (motion) echocardiogram and two-dimensional echocardiogram are complementary studies that have proved useful for identification of cardiac septal defects, endocarditis, pericardial effusion, intracardiac shunting, cardiomegaly, and heart muscle failure. Appreciation of the technique and basic knowledge of the types of info...
Reef VB.A thorough examination of the cardiovascular system is an integral part of a physical examination in the horse. The normal equine cardiovascular parameters are discussed, with an emphasis on auscultatory findings. The availability and application of other diagnostic techniques are discussed based upon findings of the physical examination.
Bonagura JD.The clinician must appreciate unique aspects of equine cardiovascular physiology in order to distinguish normal variation from a pathophysiologic state. Cardiovascular problems in the horse include auscultation of cardiac murmurs, identification of cardiac arrhythmias, and recognition of congestive heart failure. A cardiac data base including history, general and cardiovascular examination, and resting and postexercise electrocardiogram are necessary to evaluate most horses for significant heart disease. Additional studies, such as echocardiography and cardiac catheterization, are useful in se...
van Aarde MN, Littlejohn A, Van der Walt JJ.A method was developed for determining the ratio of cardiopulmonary blood volume to stroke volume, in horses. The radioisotope 99 Tc (technetium 99m pertechnetate) was injected into the jugular vein as a bolus, which was then detected in the right and left ventricles consecutively by a scanning device consisting of a Na I crystal, a collimator, an amplifier and a discriminator. The radiocardiogram (RCG) and the ECG were recorded simultaneously by a two-channel writing device. The ratio of cardiopulmonary blood volume to stroke volume (cardiopulmonary flow index = CPFI) was then determined from...
Stewart JH, Rose RJ, Barko AM.Simultaneous echocardiograms, phonocardiograms and electrocardiograms were performed on 16 foals at the following times after birth: 15 mins, 60 mins, 2, 4, 12, 24, 48 h, four, seven, 14 days and four, eight and 12 weeks. Positive correlations were found between both age and body weight and the following measurements: left ventricular end-diastolic dimension, right ventricular end-diastolic dimension, left atrial dimension and aortic root dimension, posterior left ventricular wall thickness and interventricular septal thickness. Heart rate was negatively correlated with left ventricular electr...
Lombard CW, Evans M, Martin L, Tehrani J.Twelve newborn pony foals underwent cardiovascular examinations (auscultation, arterial blood pressure measurements, electrocardiograms and M-mode echocardiograms) on their first day of life and then on Days 7, 14, 21, 30, 60 and 90. An age dependent, statistically significant, rapid increase of the arterial blood pressure in the first month was documented together with a slower decrease of the resting heart rate after two and three months of life. Innocent soft systolic murmurs were audible over the left heart base in a large number of the foals. The electrocardiograms showed age dependent in...
Holmes JR, Miller PJ.The paper describes clinical observations in three horses with ruptured mitral valve chordae. Horses with ruptured mitral valve chordae may have a history of sudden onset of acute distress with predominantly respiratory symptoms. On auscultation there will be a widespread pansystolic murmur with an extension of the area of cardiac auscultation. The third heart sound may be very pronounced and unduly prolonged, associated with high volume flow during early ventricular filling in diastole. However, these sounds are not specific for chordal rupture--they are typical of severe mitral regurgitation...
Lombard CW, Scarratt WK, Buergelt CD.Clinical, echocardiographic, and right-side cardiac catheterization data were collected in 6 horses with ventricular septal defects. The defects were confirmed by necropsy in 5 horses. On echocardiography, the cardiac dimensions were normal in 3 horses and enlarged in 2 others. A step-up in partial oxygen pressure between right atrium and right ventricle suggested a left-to-right shunt in 3 of the 4 horses catheterized. In 1 foal, a small defect without PO2 step-up was documented by angiocardiography. The oxymetry and pressure data were compared with previous cases from the reviewed literature...
Bonagura JD, Pipers FS.A horse, a cow, and a dog with aortic valve vegetative endocarditis were studied by M-mode echocardiography. Echocardiographic abnormalities of the aortic valve, mitral valve, and left ventricle were observed. These features were identical to those reported in human beings with aortic valve endocarditis. Abnormalities associated with aortic valve endocarditis included irregular thickening of the valve, multiple linear echoes in the aortic root, diastolic prolapse of the aortic vegetation, and diastolic fluttering of a torn aortic valve. Some of these features were found in each animal. The con...
Bonagura JD, Pipers FS.Contrast M-mode echocardiography was utilized to study animals with congenital and acquired cardiac defects. Contrast was produced through the rapid injection of isotonic NaCl solution, the patient's blood, or indocyanine green dye into the circulation. Peripheral vein and intracardiac injections of contrast material were used to document ventricular septal defect, tetralogy of Fallot, atrial septal defect, and mitral valve regurgitation. The technique was safe and useful for both small and large animals.
Durando MM, Reef VB, Birks EK.Thorough evaluation of myocardial function remains difficult to evaluate under exercising conditions. This study described right ventricular (RV) pressure dynamics during and immediately following exercise. Nine Thoroughbreds without evidence of cardiac disease completed treadmill exercise at 110% of the speed necessary to elicit VO2max while RV pressures were recorded. RV pressure dynamics were calculated at rest, maximal speed and at 10 s intervals for 2 min after exercise. Stress echocardiography was performed at rest and within 120 s after exercise. Mean dP/dtmax and dP/dtmin values were s...
Stern JA, Doreste YR, Barnett S, Lahmers SM, Baumwart RD, Seino KK, Bonagura JD.Sustained narrow-QRS tachycardia of three months duration and left ventricular systolic dysfunction were identified in a fifteen-year-old Quarter Horse. No underlying cause for the tachyarrhythmia was found and no predisposing structural cardiac lesions were evident by echocardiography. Intravenous diltiazem and lidocaine were administered without achieving successful conversion of the arrhythmia. Oral quinidine therapy converted the tachyarrhythmia to sinus rhythm. Ventricular systolic dysfunction and chamber dilatation subsequently resolved. As with other species, echocardiographic features ...
Weigle GE, Langsetmo I, Gallagher RR, Dyer RA, Erickson HH, Fedde MR.The objective of this study was to develop and test a technique to allow dynamic cardiac function to be studied during exercise in the horse. Blood pressure waveforms in the exercising horse are difficult to interpret because of the large influence of stride and respiration. A method has been devised to study dynamic right ventricular variables during high-speed exercise in the horse. A Fast Fourier Transform was performed on the digitised pressure waveforms and the frequency components associated with stride and respiration were removed. An inverse Fourier Transform was then performed to gene...
Fries RC, Clark-Price SC, Kadotani S, Stack JP, Schaeffer DJ, Lascola KM.To compare measurements of left ventricular volume and function derived from 2-D transthoracic echocardiography (2DE), transesophageal echocardiography (TEE), and the ultrasound velocity dilution cardiac output method (UDCO) with those derived from cardiac MRI (cMRI) in healthy neonatal foals. Methods: 6 healthy 1-week-old Standardbred foals. Methods: Foals were anesthetized and underwent 2DE, TEE, and cMRI; UDCO was performed simultaneously with 2DE. Images acquired by 2DE included the right parasternal 4-chamber (R4CH), left apical 4- and 2-chamber (biplane), and right parasternal short-axis...
Valdes-Martinez A, Eades SC, Strickland KN, Roberts ED.We describe the echocardiographic findings in a 4-day-old thoroughbred foal with an aortico-pulmonary septal defect. The foal had labored breathing, cyanotic mucous membranes and a continuous grade 5/6 heart murmur with point of maximal intensity over the base of the heart on the right side. Echocardiographically, there was a large communication between the aorta and the pulmonary artery just dorsal to the base of the heart. The cardiac anomaly seen during the echocardiographic exam was confirmed at necropsy where a large communication between the two great vessels was observed. These findings...
Gehlen H, Shety T, El-Zahar H, Hofheinz I.Cardiac biomarkers are important tools for monitoring disease progress and can monitor progression of therapy. Endothelin-1 (ET-1) has been studied for its use as a cardiac biomarker in human and small animal medicine while in horses with cardiac disease it has not been evaluated yet. The objective of the present study was to determine the concentration of plasma ET-1 in healthy horses and compare it with ET-1 concentration in horses with cardiac disease during rest and after exercise. Fifty four horses admitted to the Equine Clinic of Free University of Berlin were used in the present study, ...
Alberti E, Stucchi L, Lo Feudo CM, Ferrucci F, Zucca E.Pulmonary artery stiffness (PAS) is an index of pulmonary artery elasticity that permits to evaluate the pulmonary vascular bed in humans. It can early detect an increase in pulmonary artery stiffness as a consequence of remodeling of the vessel wall caused by chronic pulmonary and congenital heart diseases. This remodeling can occur also in horses with chronic respiratory diseases. Thus, PAS could be a useful echocardiographic parameter also in horses. However, in literature, there are no studies regarding PAS in horses. The aim of this study is to evaluate the feasibility of PAS in horses. F...
Ter Woort F, Stefanovski D, Reef VB.Hyperthyroidism is a predisposing factor for atrial fibrillation (AF) in humans. The relationship between high thyroid hormone (TH) and AF in horses has not been evaluated. Objective: The aim of this study is to identify whether (1) high TH concentrations were present in horses with AF, (2) other cardiovascular effects were observed in horses with high TH and AF, and (3) TH status affected recurrence rate. Methods: Twenty-three horses presented with naturally occurring AF. Methods: Prospective case-control clinical study. Thyroid hormone concentration was measured in horses presenting with AF....
Gehlen H, Bubeck K, Rohn K, Stadler P.The aim of this study was to investigate the potential haemodynamic effects of valvular insufficiency and recurrent airway obstruction (RAO) in horses with atrial fibrillation (AF). Therefore in ten healthy horses (group 1) and 40 horses with AF a clinical examination, a lung examination, echocardiography and right heart catheterization for measurement of intracardic and pulmonary pressures were performed. According to the clinical findings the horses with AF were subdivided into 4 groups (group 2: AF; group 3: AF/valvular insufficiency; group 4: AF/RAO; group 5: AF/valvular insufficiency/RAO)...
Mizuno Y, Aida H, Hara H, Fujinaga T, Hagio M.Cardiac output (CO) measurements by the three methods of dye dilution, pulsed Doppler echocardiography and thermodilution in horses under anesthetized conditions were compared. Although CO determined by the thermodilution method was slightly higher than those obtained by the other two methods, the measurements by all methods showed almost similar results. The coefficients of correlation between the dye dilution and thermodilution methods, the dye dilution and pulsed Doppler echocardiography methods, and the thermodilution and pulsed Doppler echocardiography methods were 0.87, 0.89, and 0.88, r...
Sepulveda MF, Perkins JD, Bowen IM, Marr CM.Doppler tissue imaging (DTI) is a novel noninvasive method by which myocardial velocity can be assessed directly and it allows regional, rather than global, cardiac function to be evaluated. Objective: That regional differences in myocardial velocities exist within the equine ventricle. Objective: To develop a repeatable examination technique for DTI in horses, describe DTI findings in various regions of the normal equine ventricle, compare colour (CDTI) and spectral (SDTI) techniques of DTI, and document regional differences in myocardial velocity. Methods: Five regions of the ventricles (rig...
Marr CM.Echocardiography is an extremely versatile tool for both the equine clinician and physiologist. There are three useful forms of echocardiography, B mode, M mode and Doppler. Together they provide complementary information on cardiac disease and haemodynamic status. B mode is used to image the cardiac chambers, valves, myocardium and pericardium. M mode allows determination of motion of cardiac structures; it is superior to B mode for timing of events and it is used to make precise measurements of the heart. Doppler echocardiography can assess intracardiac blood flow and its velocity. Echocardi...
Wingfield WE, Miller CW, Voss JL, Bennett DG, Breukels J.Echocardiography is a non-invasive, safe means of assessing intracardiac structures and their motion. In the normal motion of the mitral valve there is anterior motion noted during atrial systole. In 3 horses with atrial fibrillation the mitral valve motion had no anterior motion to correspond with atrial contractions. Quinidine returned the electrocardiogram of one horse to a sinus rhythm after which echocardiography demonstrated the reappearance of the anterior motion of the mitral valve.
Gehlen H, Groner U, Rohn K, Stadler P.In 18 horses, the pulmonary artery wedge pressure and the heart rate were measured during pharmacological stress load. 12 horses were healthy (4 trained, 8 untrained) and 6 horses had a heart disease (3 trained, 3 untrained). Pharmacological stress induction was carried out with the sympathomimetic drug dobutamine at a dosage rate of 7.5 microg/kg/min over 10 minutes of infusion. At the fourth minute, the parasympatholytic drug atropine was administered (5 microg/kg bw), and the heart rate and the pulmonary artery wedge pressure were continuously measured over 26 minutes. During sole dobutamin...
Stadler P, Weinberger T, Kinkel N, Deegen E.B- and M-mode echocardiography was performed on 38 horses. 34 patients had systolic heart murmur with the point of maximal intensity over mitral valve. Additionally, 17 of these patients were examined with the pulsed wave doppler echocardiography (Vingmed 200). In 26 patients with cardiac murmur and in 4 patients without cardiac murmur a mitral valve insufficiency was diagnosed by echocardiography. In 8 horses with a systolic murmur over mitral valve M- and B-mode evaluation could not reveal a haemodynamic importance of the murmur. The diagnosis of MVI was based on a dilation of left atrium wi...
Gehlen H, Haubold A, Rohn K, Stadler P.In the present study we examined, if in Icelandic horses an increase in heart and/ or breathing rate is physiological and breed dependend or a sign of a pulmonary or cardiac disease. Therefore we examined 37 Icelandic horses with the prereport of being healthy. During clinical lung examination four horses showed symptoms of a pulmonary disease like increased breathing rate and enforced breathing at rest. These horses were excluded from the study. The other 33 horses were clinically normal. 17 of these horses were unridden (untrained) and 16 horses were regularly worked (trained). After clinica...
Gehlen H, Bubeck K, Stadler P.In 12 healthy warmblood horses (six trained and six untrained) the pulmonary wedge pressure and heart frequency was measured at rest and during a standardised exercise test on a treadmill. The mean pulmonary wedge pressure at rest was 14.53 +/- 2.36 mmHg. There was no significant difference in pulmonary wedge pressure either at rest or during exercise between trained and untrained horses. During walking (1.8 m/s) the mean pulmonary wedge pressure was 19.62 +/- 4.03 mmHg, during trotting (4 und 5 m/s) it was between 22.38 +/- 3.92 mmHg and 25.28 +/- 3.7 mmHg. During canter (6 m/s) and gallop (8...
Vitale V, Van Galen G, Laurberg M, Young B, Mciver V, Wereszka M, Gimeno M.Congenital heart disease is relatively uncommon in horses. Only three reports exist that describe a tetralogy of Fallot in adult horses. Whereas in humans the presence of congenital heart disease constitutes a risk factor for developing aortic aneurysms, their association has never been reported in horses. Here, we present a case with a large ascending aortic aneurysm as a complication of a tetralogy of Fallot in an adult mare. The mare was referred with sustained tachycardia and a 5 days history of mild intermittent colic, depression, inappetence and weight loss. Echocardiography was used to...
Marr CM, Bright JM, Marlin DJ, Harris PA, Roberts CA.We hypothesised that exercise in a hot and humid environment would affect echocardiographic indices of cardiac dimensions and function more than exercise in a cool environment. M-mode echocardiograms were obtained in 5 clinically normal horses before, and at 0, 10, 30 and 60 min after a treadmill exercise test. The test was performed in a controlled environment at 20 degrees C/40% relative humidity (RH) and again at 30 degrees C/80% RH. All the horses completed the exercise test in cool conditions, but only one horse completed the exercise test in the hot/humid environment. The relaxation time...
East LM, Steyn PF, Dickinson CE, Frank AA.A 5-year-old Arabian horse was admitted with a 5-day history of undulant pyrexia of unknown origin, inappetence, obtundation, and acute collapse. Physical examination results were unremarkable except for a grade II/VI left-sided systolic cardiac murmur and abdominal splinting. Mild chronic inflammatory changes were evident on clinicopathologic evaluation. Echocardiography revealed moderate aortic insufficiency. A solitary soft tissue opacity was found on thoracic radiography but not on ultrasonography. Palliative treatment was ineffective. Nuclear scintigraphy with WBC labeled with technetium ...
Young LE, Helwegen MM, Rogers K, Kearns L, Schreiber C, Wood JL.Exercise-induced pulmonary haemorrhage (EIPH) and tricuspid (TR) and mitral valve regurgitation (MR) are conditions with high prevalence in conditioned Thoroughbreds. Stress failure of pulmonary capillaries, leading to EIPH, is most likely when pulmonary vascular pressure is increased, and mitral regurgitation can result in pulmonary venous hypertension. Objective: There might be an association between MR and EIPH and the right ventricle (RV) of horses known to suffer repeated episodes of EIPH, as their hearts would be subject to higher pulmonary vascular pressures and cardiac output during tr...
Bakos Z, Vörös K.Since percussion started to be a method forgotten and not trusted by many practitioners, the aim of the study was to demonstrate whether this procedure could deliver exact data if done accurately and by a practised examiner. The trial presented here included 31 healthy warm-blooded horses. Percussion of the area of cardiac dullness and then echocardiographic imaging of the same region were performed. To obtain the relevant measurement points, the 4th and 5th intercostal spaces (ICS) were used on the left and the 4th ICS on the right side. On the left side, the dorsal border of cardiac dullness...
Schwarzwald CC, Bonagura JD, Luis-Fuentes V.Quinidine is effective for treatment of atrial fibrillation (AF) in horses, but often accelerates ventricular response rate. Diltiazem effectively controls heart rate response to AF in other species. This investigation determined the effects of diltiazem on cardiac rate and rhythm, left ventricular (LV) function, central hemodynamics, and peripheral blood flow in normal, standing, nonsedated horses. A dose-finding study was performed. Afterward, 8 healthy horses were treated with diltiazem IV every 30 minutes to achieve cumulative dosages of 0 (saline control), 1, 1.5, and 2 mg/kg. Plasma dilt...
Meyer C, Gerber R, Guthrie AJ.A 4-year-old Thoroughbred gelding racehorse was referred to the Onderstepoort Veterinary Academic Hospital (OVAH) with a history of post-race distress and collapse. In the absence of any obvious abnormalities in the preceding diagnostic work-up, a standard exercise test was performed to determine an underlying cause for the post-race distress reported. In this particular case oxygen desaturation became evident at speeds as slow as 6 m/s, where PO2 was measured at 82.3 mm Hg. Similarly at a blood pH of 7.28, PCO2 had dropped to 30.0 mm Hg indicating a combined metabolic acidosis and respiratory...
Helwegen MM, Young LE, Rogers K, Wood JL.The effect of tricuspid valve regurgitation (TR) in right ventricular (RV) chamber size has not been reported. Methods: An echocardiographic and auscultation study was conducted on 394 race-fit National Hunt Thoroughbreds (TBs) in 4 training yards. Auscultation was performed on each horse and audible murmurs of TR graded using a 1-6 scale. Echocardiography was also performed and standard, 2-dimensional (2D), short (SA) and long axis (LA) images of the RV obtained from a right parasternal location. An m-mode image was recorded from an SA view of the RV just below the level of the tricuspid valv...
Gehlen H, Vieht JC, Stadler P.Twenty horses with mitral valve insufficiency, but without signs of congestive heart failure, and five horses without signs of heart disease were examined before and after medication with an angiotensin-converting enzyme (ACE) inhibitor. The examination included echocardiography assessment as well as heart catheterization. The echocardiographic examination included B-mode, M-mode, conventional and colour Doppler techniques. For 8 weeks, all horses were treated with Accupro 20 (active substance: Quinapril) at an oral dose rate of 120 mg/horse/day. A follow-up of the horses with mitral valve ins...
Vörös K.Quantitative two-dimensional echocardiography (2DE) was introduced into equine cardiology in the early 1990s. At first, linear and area dimensions and left ventricular volume were validated by the comparison of parameters determined during in vitro 2DE and autopsy measurements. Based on these studies, tomographic planes and intracardiac reference points for in vivo measurements were established and 2DE values have been determined for healthy adult horses by various authors. These data were similar to each other and proved to be comparable with M-mode echocardiography measurements. However, dif...
Peters ST, Hopkins A, Stewart S, Slack J, de Solis CN.To describe the clinical findings and management of myocardial injury secondary to blunt thoracic trauma and rib fracture in an adult horse. Methods: A 6-year-old Warmblood gelding presented for treatment of blunt thoracic trauma. Sonographic examination of the thorax revealed a complete, mildly comminuted fracture of the left 5th rib with a fragment overlying the left atrium and coronary artery, hemothorax, and subjective left ventricular dyskinesis. Evidence of myocardial injury included atrial fibrillation, ventricular ectopy, and increased plasma cardiac troponin I concentration. The rib f...
Vitums A, Grant BD, Stone EC, Spencer GR.ABSTRACT Transposition of the aorta to the right ventricle with atresia of the pulmonary trunk was described in a 2 year old horse. Clinical and physiological examinations were performed and data recorded. Teratogenesis of the present anomaly was discussed and the literature reviewed. The probable course of circulation during the fetal life and after birth of this animal was suggested. An extensive col-lateral circulation was developed to the lungs, which might explain how the animal could live so long.