Echocardiography is a diagnostic imaging technique used to assess the heart's structure and function in horses. It utilizes ultrasound waves to create detailed images of the heart, allowing veterinarians to evaluate cardiac anatomy, blood flow, and heart motion. Echocardiography is instrumental in diagnosing various cardiac conditions, such as valvular disorders, congenital heart defects, and myocardial diseases in equine patients. The procedure provides valuable information on heart size, wall thickness, and chamber dimensions. This page compiles peer-reviewed research studies and scholarly articles that explore the methodologies, applications, and clinical implications of echocardiography in equine cardiology.
Phillips W, Giguère S, Franklin RP, Hernandez J, Adin D, Peloso JG.Cardiac troponin I (cTnI), a myocardial polypeptide, is a highly sensitive and specific biomarker of myocardial injury in people and dogs. The structure of cTnI is highly conserved across species, and equine myocardium has high reactivity with human immunoassays. The purpose of this study was to describe cTnI concentrations in normal pastured and race-training Thoroughbred horses. Ten horses on pasture and 10 horses in race training were studied. Horses were considered normal on the basis of physical examination, training performance, electrocardiography (ECG), and echocardiography. Serum cTnI...
Guglielmini C, Bernardini D.A seven-month-old male Standardbred was referred with a 4-month history of left jugular groove distension. On physical examination severely dilated left maxillary, linguofacial and jugular veins were appreciable. Blood gas analysis results indicated higher degree of oxygenation in the left jugular vein. Bi-directional flow signals, with normal systolic and early diastolic flow, and late diastolic retrograde flow, were noted on pulsed-wave Doppler interrogation and color flow mapping of the left jugular blood flow. A systolic-diastolic signal with spectral broadening was detected when positioni...
Corley KT, Donaldson LL, Durando MM, Birks EK.Critical illness, anesthesia, primary cardiovascular disease, and exercise may result in marked hemodynamic alterations. Measuring cardiac output (CO) is central to defining these alterations for both clinician and researcher. In the past 10 years, several new methods of measuring CO have been developed for the human medical market. Some of these methods are now validated in the horse and are in clinical use. The Fick method has been used in equine research for more than a century. It depends on simultaneous measurement of mixed venous (pulmonary arterial) and peripheral arterial oxygen conten...
Frye MA, Bright JM, Dargatz DA, Fettman MJ, Frisbie DD, Baker DC, Traub-Dargatz JL.This study was done to determine whether administration of dobutamine would produce echocardiographic and electrocardiographic alterations comparable to those induced by treadmill exercise in healthy horses. Fourteen horses received maximal treadmill exercise and, separately, intravenous dobutamine infusion up to a maximum rate of 50 microg/kg/min. Ten of the 14 horses were euthanized, and the myocardial tissues were examined grossly and histopathologically. No significant differences were found in the chronotropic effects of dobutamine and exercise (P = .905). Dobutamine induced greater inter...
Durando MM, Reef VB, Birks EK.Thorough evaluation of myocardial function remains difficult to evaluate under exercising conditions. This study described right ventricular (RV) pressure dynamics during and immediately following exercise. Nine Thoroughbreds without evidence of cardiac disease completed treadmill exercise at 110% of the speed necessary to elicit VO2max while RV pressures were recorded. RV pressure dynamics were calculated at rest, maximal speed and at 10 s intervals for 2 min after exercise. Stress echocardiography was performed at rest and within 120 s after exercise. Mean dP/dtmax and dP/dtmin values were s...
Ohmura H, Hiraga A, Matsui A, Aida H, Inoue Y, Asai Y, Jones JH.Yearling horses are typically trained for more than a year before they begin racing; therefore, we questioned how relevant analyses of the initial responses to training are compared to physiological responses that occur over a year of training, and whether young horses with no history of training would respond the same as older horses that had been trained previously. We hypothesised that changes in O2 transport over the last months of a year of training would be different than at the beginning. We trained 5 yearling Thoroughbreds and evaluated metabolism, O2 transport and echocardiograms. Mea...
Young LE, Marlin DJ, Deaton C, Brown-Feltner H, Roberts CA, Wood JL.Maximum oxygen uptake also appears to correlate to athletic performance in horses. In the Thoroughbred industry, there has long been an empirical theory that heart size is related to athletic performance, despite a lack of scientific evidence supporting this assertion. To investigate the relationship between peak oxygen consumption (VO2max) and cardiac size measured by echocardiography, guided M-mode and 2-dimensional echocardiography were performed in 17 conditioned Thoroughbreds with a range of VO2max from 126 to 217 ml/min/kg STPD (mean +/- s.d. 158 +/- 28 m/min/kg). Horses were age 2-10 ye...
Bakos Z, Vörös K, Järvinen T, Reiczigel J.The aim of the study was to establish normal echocardiographic values of healthy Standardbred trotters not published previously. Twenty-three clinically normal horses weighing between 350 and 490 kg were examined in the same manner: first a thorough physical and then detailed echocardiographic examination were performed. Standardised two-dimensional (2D) and guided M-mode echocardiographic imaging techniques were used to measure interventricular septal thickness (IVS), left ventricular internal diameter (LVID), left ventricular wall thickness (LVW), left atrial internal diameter (LAID) in end-...
Kriz NG, Rose RJ.To assess the repeatability of commonly employed transthoracic echocardiographic measurements in standing horses. Methods: Thirteen healthy 3- to 4-year-old fit Standardbred geldings with a mean weight of 411 (SEM +/- 10) kg were studied. The horses' environment, feeding and management regimens were standardised. All measurements were performed by the same investigator at the same time every day for three consecutive days. Methods: Standard transthoracic measurements were made on all horses. Each measurement was performed over three consecutive cardiac cycles on 1 day and all measurements were...
Davis JL, Gardner SY, Schwabenton B, Breuhaus BA.To identify clinical signs, underlying cardiac conditions, echocardiographic findings, and prognosis for horses with congestive heart failure. Methods: Retrospective study. Methods: 14 horses. Methods: Signalment; history; clinical signs; clinicopathologic, echocardiographic, and radiographic findings; treatment; and outcome were determined by reviewing medical records. Results: All 14 horses were examined because of a heart murmur; tachycardia was identified in all 14. Twelve horses had echocardiographic evidence of enlargement of 1 or more chambers of the heart. Other common clinical finding...
Sleeper MM, Kearns CF, McKeever KH.Chronic administration of pharmacological levels of beta2-agonists have been shown to have toxic effects on the heart; however, no data exist on cardiac function after chronic clenbuterol administration. The purpose of this study was to examine the effect of therapeutic levels of clenbuterol on cardiac performance. Methods: Twenty unfit Standardbred mares were divided into four experimental groups: clenbuterol (2.4 microg.kg(-1) twice daily 5 d.wk(-1)) plus exercise (20 min at 50% .VO(2max)) (CLENEX; N = 6), clenbuterol (CLEN; N = 6), exercise (EX; N = 4), and control (CON; N = 4). M-mode and ...
van Loon G, Fonteyne W, Rottiers H, Tavernier R, Jordaens L, D'Hont L, Colpaert R, De Clercq T, Deprez P.The purpose of the present study was to develop a feasible and safe technique for dual-chamber pacemaker implantation in healthy horses. Implantation was performed in a standing, tranquilized horse and in ponies. Atrial and ventricular leads were transvenously inserted through the cephalic vein, and a subcutaneous pacemaker pocket was created between the lateral pectoral groove and the manubrium sterni in 6 equids. Positioning of each lead was guided by echocardiography and by measuring the electrical characteristics of the lead. The implantation procedure lasted about 4 hours in each animal a...
Reef VB.Stress echocardiography in the horse is in its infancy, and investigations need to continue to determine the significance and mechanism of postexercise echocardiographic abnormalities detected in horses. This work should be coupled with investigations on the exercise-induced changes in cardiac isoenzymes, cTnI, arterial oxygen content, and cardiac rhythm that may occur concurrently. With continued investigations into the cardiovascular problems that occur in the exercising horse, the sport horse veterinarian should be better able to accurately diagnose and treat problems causing poor performan...
Kriz NG, Hodgson DR, Rose RJ.To investigate the effects of deconditioning on cardiac dimensions and indices of cardiac function in horses. Methods: Thirteen 3-to 4-year-old Standardbred geldings. Methods: All horses had echocardiographic measurements performed at the conclusion of 9 months of intense training and at weeks 1.5, 4, 8, and 12 of deconditioning. Direct echocardiographic measurements included interventricular septal thickness, left ventricular internal dimensions, left ventricular freewall thickness, left atrial dimension, aortic diameter, diameter of the pulmonary artery, slopes of the mitral valve, heart rat...
Raisis AL, Young LE, Blissitt KJ, Walsh K, Meire HB, Taylor PM, Lekeux P.To evaluate the hemodynamic effects of dobutamine hydrochloride (0.5 microg/kg of body weight/min) in halothane-anesthetized horses. Methods: 6 adult Thoroughbred horses. Methods: Anesthesia was induced by use of romifidine (100 microg/kg) and ketamine (2.2 mg/kg), IV. Anesthesia was maintained by halothane (end-tidal concentration 0.9 to 1.0%). Aortic, left ventricular, and right atrial pressures were measured, using catheter-mounted strain gauge transducers. Cardiac output (CO), velocity time integral, maximal aortic blood flow velocity and acceleration, and left ventricular preejection peri...
Raisis AL, Young LE, Blissitt KJ, Brearley JC, Meire HB, Taylor PM, Lekeux P.The purpose of this study was to compare the haemodynamic effects of equipotent isoflurane and halothane anaesthesia. Six adult horses were investigated on two separate occasions at least 4 weeks apart. On both occasions anaesthesia was induced by ketamine 2.2 mg/kg bwt given 5 min after i.v. administration 100 microg/kg bwt romifidine. Anaesthesia was maintained either by halothane or isoflurane (end-tidal concentrations 0.9-1.0% and 1.3-1.4%, respectively). Horses were ventilated by intermittent positive pressure to maintain PaCO2 between 40-50 mmHg. Haemodynamic variables were measured usin...
Linton RA, Young LE, Marlin DJ, Blissitt KJ, Brearley JC, Jonas MM, O'Brien TK, Linton NW, Band DM, Hollingworth C, Jones RS.To assess the suitability of lithium dilution as a method for measuring cardiac output in anesthetized horses, compared with thermodilution and transesophageal Doppler echocardiography. Methods: 6 horses (3 Thoroughbreds, 3 crossbreeds). Methods: Cardiac output was measured in 6 anesthetized horses as lithium dilution cardiac output (LiDCO), thermodilution cardiac output (TDCO), and transesophageal Doppler echocardiographic cardiac output (DopplerCO). For the LiDCO measurements, lithium chloride was administered i.v., and cardiac output was derived from the arterial lithium dilution curve. Sod...
Young LE, Wood JL.Cardiac auscultation was carried out on 111 Thoroughbred horses age 2-5 years to test the hypothesis that athletic training might influence the development of atrioventricular (AV) valve regurgitation in young Thoroughbreds. Murmurs of valvular regurgitation were identified and graded on a 1-6 scale. There were 2 sources of auscultation data: 1) 55 2-year-old horses that were examined by auscultation before training commenced and 9 months later when at race fitness; 2) 56 horses age 2-5 years that were examined on one occasion only (25 2-year-olds, 23 3-year-olds, five 4-year-olds and five 5-y...
Kriz NG, Hodgson DR, Rose RJ.To determine the prevalence of various types of heart murmurs in Thoroughbred racehorses and assess their association with performance by echocardiography and review of the horses' race records for the preceding 2 years. Methods: Clinical and retrospective study. Methods: 846 Thoroughbred racehorses. Methods: Cardiac auscultations were performed by 3 individuals; for 30 horses, Doppler echocardiographic examinations were also performed. Statistical analyses of race records for 753 horses were performed to assess association of heart murmurs with performance. Results: Heart murmurs were detecte...
Weigle GE, Langsetmo I, Gallagher RR, Dyer RA, Erickson HH, Fedde MR.The objective of this study was to develop and test a technique to allow dynamic cardiac function to be studied during exercise in the horse. Blood pressure waveforms in the exercising horse are difficult to interpret because of the large influence of stride and respiration. A method has been devised to study dynamic right ventricular variables during high-speed exercise in the horse. A Fast Fourier Transform was performed on the digitised pressure waveforms and the frequency components associated with stride and respiration were removed. An inverse Fourier Transform was then performed to gene...
Young LE.Guided M-mode echocardiography was performed in seven 2-year-old Thoroughbreds before commencement of commercial flat-race training, and 18 weeks later, when all horses were either racing regularly (5 horses), or at racing fitness (2 horses). M-mode echocardiography was performed using a 2.5 MHz annular phased array ultrasound transducer and a Vingmed 800 Supervision echocardiograph. Images were obtained from the right hemithorax; a short axis view of the left ventricle (LV) at the level of the chordae tendinae was used to position the M-mode cursor. The following variables were measured: left...
Sampson SN, Tucker RL, Bayly WM.We evaluated the relationships of heart score (HS) and echocardiographic measures to maximal oxygen consumption (VO2max), maximal cardiac output (Qmax), and maximal stroke volume (SVmax). Six fit, mature Thoroughbred horses weighing (mean +/- s.e.) 487 +/- 11 kg were run 4 times on an inclined (10%) treadmill. Each run consisted of a 3 min warm-up at 4 m/s followed by completion of an incremental exercise test in which each horse ran until VO2max was reached. Arterial and mixed venous blood was collected to determine arteriovenous oxygen content difference C(a-v)O2[ in the last 15 s of exercis...
Pascoe JR, Hiraga A, Hobo S, Birks EK, Yarbrough TB, Takahashi T, Hada T, Aida H, Steffey EP, Jones JH.Eight horses were fitted surgically with 8 ultrasonic sonomicrometer crystals each attached to their left ventricular pericardia and a left atrial catheter. Three horses returned to treadmill performance with a maximum rate of oxygen consumption similar to their presurgical values. These horses were evaluated to determine how well sonomicrometer estimates of cardiac output agreed with those obtained by a steady-state method, the Fick principle. Variance between the 2 was similar to the coefficient of variation (approximately 12.5%) of the Fick estimates. We conclude that left ventricular sonom...
Rueca F, Conti MB, Porciello F, Spaterna A, Antognoni MT, Mangili V, Fruganti G, Avellini G.The purpose of this study was to assess the possible relationship between maximal running speed, serum isoenzyme patterns of creatine kinase (CK) and lactate dehydrogenase (LDH) and echocardiographic indices of left ventricular function. A group of 15 healthy, 3-year-old Maremmano stallions were given a 100 day training programme. At the end of this the animals carried out a maximum speed test and were divided into 2 groups (A and B) according to whether or not they had attained a speed of 15 m/s. Venous blood samples were taken from each horse before exercise (T0), 2 min (T1) and 24 h (T2) af...
Hiraga A, Hobo S, Birks EK, Takahashi T, Hada T, Smith BL, Carr EA, Pascoe JR, Jones JH.Three mature Thoroughbred horses were prepared surgically with ultrasonic sonomicrometer crystals affixed to their ventricular pericardia. Signals from crystals recorded dimensions of axes across the left ventricle. Cubic algorithms were fitted to dimensional data to generate volume estimates that matched stroke volumes simultaneously measured using the Fick principle. As horses stood at rest or exercised at various intensities (approx 7, 12, 24, 47 and 100% maximal rate of O2 consumption VO2max[), left ventricular dimensions were recorded and 20 consecutive diastolic and systolic volumes calc...
Marr CM, Bright JM, Marlin DJ, Harris PA, Roberts CA.We hypothesised that exercise in a hot and humid environment would affect echocardiographic indices of cardiac dimensions and function more than exercise in a cool environment. M-mode echocardiograms were obtained in 5 clinically normal horses before, and at 0, 10, 30 and 60 min after a treadmill exercise test. The test was performed in a controlled environment at 20 degrees C/40% relative humidity (RH) and again at 30 degrees C/80% RH. All the horses completed the exercise test in cool conditions, but only one horse completed the exercise test in the hot/humid environment. The relaxation time...
East LM, Steyn PF, Dickinson CE, Frank AA.A 5-year-old Arabian horse was admitted with a 5-day history of undulant pyrexia of unknown origin, inappetence, obtundation, and acute collapse. Physical examination results were unremarkable except for a grade II/VI left-sided systolic cardiac murmur and abdominal splinting. Mild chronic inflammatory changes were evident on clinicopathologic evaluation. Echocardiography revealed moderate aortic insufficiency. A solitary soft tissue opacity was found on thoracic radiography but not on ultrasonography. Palliative treatment was ineffective. Nuclear scintigraphy with WBC labeled with technetium ...
Young LE, Blissitt KJ, Clutton RE, Molony V.To evaluate temporal hemodynamic effects of dobutamine in horses anesthetized with halothane. Methods: 8 adult Thoroughbreds. Methods: Anesthesia was induced by i.v. administration of romifidine and ketamine and maintained using halothane in oxygen. After 60 minutes, dobutamine was administered i.v. for 60 minutes at 4 micrograms/kg of body weight/min. Measurements of left ventricular function were obtained by transesophageal echocardiography and cardiac catheterization. Results: Mean, systolic, diastolic, aortic, pulmonary arterial, and left and right ventricular end-diastolic and systolic pr...
Young LE, Blissitt KJ, Clutton RE, Molony V.To describe the haemodynamic effects of a 60 min infusion of dopamine 4 microg/kg bwt/min during halothane anaesthesia, 7 mature Thoroughbred horses were studied. The infusion began 1 h after induction of anaesthesia by romifidine (100 microg/kg) and ketamine (2.2 mg/kg bwt). Throughout the period of dopamine infusion and for 30 min after its discontinuation, the horses were ventilated by intermittent positive pressure to maintain PaCO2 between 4.6-5.4 KPa. Inspired halothane concentration was adjusted to maintain an end tidal halothane concentration of 0.9%. Haemodynamic variables were measur...
Maxson-Sage A, Parente EJ, Beech J, Lindborg S, May LL, Teleis DC.To determine the effect of exercise on arterial blood gas tensions and upper airway and cardiac function in clinically normal Quarter Horses and horses heterozygous and homozygous for hyperkalemic periodic paralysis (HYPP). ANIMALS AND PROCEDURE: 5 clinically normal Quarter Horses, and 5 heterozygous and 2 homozygous HYPP-affected horses were examined before, during, and after exercise on a high-speed treadmill. Arterial blood gas tensions, ECG, and echocardiogram were obtained prior to exercise. Upper airway endoscopy, collection of arterial blood samples, and continuous electrocardiography w...
Seco Diaz O, Desrochers A, Hoffmann V, Reef VB.An 8-day-old Arabian-Morgan cross colt underwent cardiac evaluation. The foal was tachycardic, tachypneic, exercise intolerant and had a loud right-sided heart murmur and cyanotic mucous membranes. Total anomalous pulmonary venous connection was diagnosed with echocardiography and confirmed at postmortem examination. Total anomalous pulmonary venous connection is a very rare congenital cardiac abnormality that has not been reported before in the horse.
Pipers FS, Hamlin RL.Echocardiograms were obtained from 25 standing, clinically normal horses, using an ultrasonic recording device. The echobeam penetrated the right thoracic wall in the area of the 4th to 5th intercostal space, with a frequency of 2.5 mHz. Measurements of left ventricular wall thickness generated a mean value of 3.2 +/- 0.18 (SEM)cm, whereas the left ventricular chamber diameter in diastole was 9.3 +/- 0.30 cm and in systole was 5.7 +/- 0.23 cm. The aortic root dimensions had a mean of 7.7 cm, with a SEM of 0.16. Mitral valve closing slope (E-F) was calculated to be 17.7 +/- 0.87 mm/second, and ...
Brown CM, Holmes JR.The paper describes observations during individual cardiac cycles on the changing pressures and sounds recorded from the various chambers of the heart and aorta, related to phonocardiograms from an external microphone hand-held over the cardiac area. The majority of the first sound appears to arise from the left side of the heart after the AV valves have closed and the second sound is a consequence of sudden deceleration of blood against already closed semilunar valves. Systolic murmurs at the aortic root may be benign from increased flow and turbulence at the peak of ejection but these may no...
Brown CM, Holmes JR.The paper reports observations on the duration of various phases of the cardiac cycle using a bipole ECG record as a time base from which to measure the timing of pressure changes in the chambers of the heart and great vessels. From the findings the likely sequence of mechanical events during the cardiac cycle in the atria and ventricles is described.
Pipers FS, Reef V, Wilson J.Ventricular septal defects in a foal, a 2-year-old filly, and 2 calves were demonstrated with M-mode and two-dimensional real-time echocardiography. The studies were performed with the animals unsedated, either standing or in lateral recumbency. Cardiac windows were located between the 4th and 7th intercostal spaces, approximately at the level of the olecranon. In each case, the septal defect was visualized high in the membranous portion of the interventricular septum. Defects were visualized by use of sector scanning or linear-array ultrasonic equipment, with transducer frequencies of 2.25 to...
Deacon LJ, Navas de Solis C, Richardson DW, Polkes A, Reef VB.• An ACF developed in a hospitalized horse following orthopedic surgery. • Spontaneous closure of the ACF occurred 6 weeks after initial diagnosis. • Echocardiography is the primary imaging modality to confirm the presence of ACF in equids. [Figure: see text]
Gehlen H, Marnette S, Rohn K, Kreienbrock L, Stadler P.Echocardiographic measurements have to be reliable and reproducible with only a low day to day variability for detecting pathological changes of left ventricular myocardial function in horses. The day dependent fluctuation margin represents an important indicator for the reproducibility of a method. To find out the day to day variability of echocardiographic parameter in healthy warmblood horses, in the present study repeated echocardiographic measurements at three consecutive days were carried out (at the same time and by the same examiner) at 11 untrained and 7 trained warmblood horses. The ...
Vörös K, Holmes JR, Gibbs C.This study was performed on 15 horses to validate the cardiac anatomy as imaged with two dimensional echocardiography (2DE) and to determine the accuracy of intracardiac measurements. 2DE images were recorded in five horses in life with a Diasonics DRF100 ultrasound system and a 3.5 MHz transducer in different tomographic planes. After slaughter, the hearts were fixed in 10 per cent formalin. To compare in vivo and in vitro results, the specimens were suspended in a water-filled tank and 2DE images were made using the same transducer positions as in life. In vitro 2DE and autopsy measurements ...
Sampson SN, Tucker RL, Bayly WM.We evaluated the relationships of heart score (HS) and echocardiographic measures to maximal oxygen consumption (VO2max), maximal cardiac output (Qmax), and maximal stroke volume (SVmax). Six fit, mature Thoroughbred horses weighing (mean +/- s.e.) 487 +/- 11 kg were run 4 times on an inclined (10%) treadmill. Each run consisted of a 3 min warm-up at 4 m/s followed by completion of an incremental exercise test in which each horse ran until VO2max was reached. Arterial and mixed venous blood was collected to determine arteriovenous oxygen content difference C(a-v)O2[ in the last 15 s of exercis...
Afonso T, Giguère S, Brown SA, Barton MH, Rapoport G, Barba M, Dembek KA, Toribio RE, Coleman AE.Despite the paucity of data available, orally administered angiotensin-converting enzyme (ACE) inhibitors are empirically used in horses with valvular regurgitation. Objective: Evaluate the echocardiographic and hormonal changes in response to oral benazepril in horses with left-sided valvular regurgitation. Methods: Prospective, randomised double-blind, placebo-controlled trial. Methods: Horses with mitral valve (MR) and/or aortic valve regurgitation (AR) received oral benazepril (n = 6) at a dosage of 1 mg/kg q 12 h or a placebo (n = 5) for 28 days. Echocardiography was performed before drug...
Gehlen H, Stadler P.Clinical, electrocardiographic and echocardiographic examinations were conducted before therapy and 4 days after conversion to normal sinus rhythm in 15 horses with a history of atrial fibrillation of 2-6 months duration. Seven horses showed no other signs of cardiac disease. Four horses suffered additionally from mitral valve insufficiency, while six horses had aortic valve insufficiency, including two of the four horses with mitral valve insufficiency, but none had signs of congestive heart failure. Doppler echocardiographic estimates of various variables were made for assessment of systolic...
Sedacca CD, Bright JM, Boon J.Univentricular atrioventricular (AV) connections are rare and complex congenital cardiac anomalies in which both AV valves communicate into a large, common (single) receiving chamber. The common chamber can be of left, right, or mixed ventricular morphology. Although well documented in people, reports of the double-inlet ventricle malformation are rare in the veterinary literature. This report provides description of an Arabian horse with a double-inlet univentricular connection of left ventricular type, a hypoplastic subpulmonary right ventricle, two muscular ventricular septal defects, and a...
Marzok M, Kandeel M, Babiker H, Alkhodair KM, Farag A, Ibrahim H, El-Ashker M, Alghuwainem Y, El-Khodery S.The purpose of this study was to provide a systematic meta-analysis on echocardiographic measurements in normal Thoroughbred and Standardbred horses. The current systematic meta-analysis followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA). All the available published papers on the reference values of echocardiographic assessment via M-mode echocardiography were searched, and fifteen studies were finally selected for analysis. In both fixed and random effect, the confidence interval (CI) for the interventricular septum (IVS) was 2.8-3.1 and 4.7-7.5; for the ...
Young LE, Blissitt KJ, Clutton RE, Molony V.To describe the haemodynamic effects of a 60 min infusion of dopamine 4 microg/kg bwt/min during halothane anaesthesia, 7 mature Thoroughbred horses were studied. The infusion began 1 h after induction of anaesthesia by romifidine (100 microg/kg) and ketamine (2.2 mg/kg bwt). Throughout the period of dopamine infusion and for 30 min after its discontinuation, the horses were ventilated by intermittent positive pressure to maintain PaCO2 between 4.6-5.4 KPa. Inspired halothane concentration was adjusted to maintain an end tidal halothane concentration of 0.9%. Haemodynamic variables were measur...
The heart surgery forumApril 1, 2005
Volume 7, Issue 5 E498-E502 doi: 10.1532/HSF98.20041087
Eckstein FS, Tevaearai H, Keller D, Schmidli J, Immer FF, Seiler C, Saner H, Carrel TP.This study details a single-center experience with the 3F Therapeutics stentless aortic bioprosthesis(investigational device) and is part of a prospective,nonrandomized worldwide multicenter study. We assessed the implantation procedure and the valve's efficacy in terms of early mortality and morbidity and early echocardiographic valve performance. Methods: Between June 2001 and March 2004, 24 patients (14 men/10 women) underwent aortic valve replacement(AVR) with a 3F valve. Mean age was 72 +/- 13 years(range, 31-88 years). Combined revascularization was performed in 12 patients; 1 patient re...
Worth LT, Reef VB.To determine clinical signs of pericarditis in horses and to determine whether there were any relationships among clinical signs, echocardiographic findings, treatment, and outcome. Methods: Retrospective study. Methods: 18 horses. Results: Physical examination was performed on 16 horses. Cardiovascular abnormalities included tachycardia (n = 16), pericardial friction rub (10), venous distention (7), murmur (7), muffled heart sounds (6), weak arterial pulse (6), jugular pulse (6), and edema (5). Twelve horses also had respiratory abnormalities; the most common was dull lung sounds, ventrally, ...
Buhl R, Ersbøll AK.Although valvular regurgitation is diagnosed frequently by colour Doppler echocardiography in racehorses at rest, there is currently no information about the effect of exercise on valvular regurgitation. Objective: To investigate the effect of light exercise on valvular regurgitation in a population of trotters. Methods: Standardbred trotters (n = 73) were examined by resting auscultation and echocardiography, of which 50 fullfilled the criteria of the study. Of these, 4 had reduced performance according to the trainers and were not included in the statistical analyses. Horses that showed valv...
Junge HK, Glaus T, Matos JN, Meira C, Schwarz A, Hoey S, Dennler M, Schwarzwald CC, Mitchell KJ.In a 1-day old filly with a loud heart murmur, transthoracic echocardiography revealed right ventricular hypertrophy associated with severe pulmonary valvular stenosis and a transvalvular pressure gradient (between right ventricle and pulmonary artery) of 125 mmHg. Computed tomographic angiography confirmed the finding, with no evidence of other relevant concurrent abnormalities. Balloon valvuloplasty was performed using a single balloon technique. The foal recovered well from anaesthesia. Following the procedure, the right ventricle-pulmonary artery transvalvular gradient decreased to 38 mm...
Rueca F, Conti MB, Porciello F, Spaterna A, Antognoni MT, Mangili V, Fruganti G, Avellini G.The purpose of this study was to assess the possible relationship between maximal running speed, serum isoenzyme patterns of creatine kinase (CK) and lactate dehydrogenase (LDH) and echocardiographic indices of left ventricular function. A group of 15 healthy, 3-year-old Maremmano stallions were given a 100 day training programme. At the end of this the animals carried out a maximum speed test and were divided into 2 groups (A and B) according to whether or not they had attained a speed of 15 m/s. Venous blood samples were taken from each horse before exercise (T0), 2 min (T1) and 24 h (T2) af...
Young LE, Blissitt KJ, Clutton RE, Molony V.To evaluate the hemodynamic effects of a 60-minute infusion of dopexamine in horses anesthetized with halothane. Methods: 7 adult Thoroughbreds. Methods: Measurements of left ventricular function obtained by transesophageal Doppler echocardiography and cardiac catheterization. Results: Infusion of dopexamine (4 micrograms/kg of body weight/min) significantly increased heart rate, cardiac output, maximal rates of increase and decrease of left ventricular pressure, and maximal acceleration and maximal velocity of aortic blood flow. Left ventricular ejection time significantly increased, and pre-...
Brinkman EL, Weed BC, Patnaik SS, Brazile BL, Centini RM, Wills RW, Olivier B, Sledge DG, Cooley J, Liao J, Rashmir-Raven AM.OBJECTIVE To compare biomechanical and histologic features of heart valves and echocardiographic findings between Quarter Horses with and without heritable equine regional dermal asthenia (HERDA). DESIGN Prospective case-control study. ANIMALS 41 Quarter Horses. PROCEDURES Ultimate tensile strength (UTS) of aortic and mitral valve leaflets was assessed by biomechanical testing in 5 horses with HERDA and 5 horses without HERDA (controls). Histologic evaluation of aortic and mitral valves was performed for 6 HERDA-affected and 3 control horses. Echocardiography was performed in 14 HERDA-affected...
Gehlen H, Fisch J, Merle R, Trachsel DS.Pituitary pars intermedia dysfunction (PPID), a neurodegenerative disease leading to reduced dopamine production, is a common disease in aged horses. The treatment is based on administration of the dopamine agonist pergolide. This drug has been related to valvular fibrosis in humans, but the cardiovascular effect of this drug has not yet been investigated in horses. Objective: To determine whether pergolide induces valvular disease in horses or affects the cardiac function. Methods: Standard, tissue Doppler (TDE) and two-dimensional speckle tracking (STE) echocardiography were performed in hor...
Hiraga A, Hobo S, Birks EK, Takahashi T, Hada T, Smith BL, Carr EA, Pascoe JR, Jones JH.Three mature Thoroughbred horses were prepared surgically with ultrasonic sonomicrometer crystals affixed to their ventricular pericardia. Signals from crystals recorded dimensions of axes across the left ventricle. Cubic algorithms were fitted to dimensional data to generate volume estimates that matched stroke volumes simultaneously measured using the Fick principle. As horses stood at rest or exercised at various intensities (approx 7, 12, 24, 47 and 100% maximal rate of O2 consumption VO2max[), left ventricular dimensions were recorded and 20 consecutive diastolic and systolic volumes calc...
Drábková Z, Amory H, Kabeš R, Melková P, van Loon G.A partial atrioventricular septal defect, represented as a large ostium primum atrial septal defect and common (bridging) atrioventricular valve leaflets with cleft septal leaflet of the mitral valve, was diagnosed incidentally in a nine-year-old warmblood gelding used for show jumping. Initial examination findings and a three-year follow-up are documented in this report. The horse was first presented for the evaluation of chronic coughing. A left-sided, grade 4/6 holosystolic (band-shaped) murmur was identified along with a similar right-sided, grade 3/6 heart murmur. Echocardiography reveale...
Kvart C, Carlsten J, Jeffcott LB, Nilsfors L.M-mode echocardiography is a safe and practical means of using ultrasound to evaluate the dynamic movements of cardiac structures. The technique can be refined by using a simple contrast medium in the form of carbon dioxide mixed with heparinised blood to provide a strong echogenic result. This technique was employed in a series of 15 normal conscious standing horses and in three animals with specific cardiac defects. In the clinical cases it was possible to confirm the diagnosis and differentiate between a congenital septal defect and mitral regurgitation. The method was found to be safe and ...
Gehlen H, Sundermann T, Rohn K, Stadler P.This study measured plasma atrial natriuretic peptide (ANP) concentration in horses with heart valve regurgitations (HVR) with and without atrial and ventricular dilatation. Background: In humans and small animals, plasma ANP concentration is increased in heart disease and correlates with the severity of clinical signs and heart enlargement. Methods: Ten healthy horses (control) and 36 horses with HVR were evaluated by auscultation, electrocardiography, echocardiography, and determination of plasma ANP. Results: Control horses demonstrated mean plasma ANP concentration of 21+/-5.4 pg/mL. Of th...
Walders W, Gehlen H.This study evaluated a device for blood pressure measurement using high definition oscillometry (HDO) for its acceptability and practicability in the horse. Furthermore, we evaluated whether this device can determine differences in blood pressure between healthy horses and horses with heart diseases and between different measurement times. Methods: The study population consisted of 60 horses (aged 4-31 years). All horses underwent clinical examination, conventional echocardiography (including cardiac output measurement at the pulmonary artery), repeated noninvasive blood pressure measurement a...
Reimer JM, Reef VB, Sommer M.Pulmonic valve rupture was determined to be the cause of severe right-sided heart failure in a 20-year-old Thoroughbred gelding. A flail in the intermediate pulmonic valve cusp was detected by 2-dimensional echocardiography. Significant pulmonic and tricuspid valvular regurgitation were confirmed by Doppler echocardiography. Despite treatment, the horse's condition deteriorated, and euthanasia was performed. At necropsy, a tear in the pulmonary artery extending into the right valve cusp and a tear at the base of the intermediate valve cusp were identified at the junction of the right and inter...
Reef VB.Mitral valvular insufficiency associated with ruptured chordae tendineae was diagnosed in 3 foals with signs of congestive heart failure, which were believed to be secondary to the development of pulmonary hypertension associated with the valvular insufficiency. The septal leaflet of the mitral valve was affected in all 3 foals, and foal 2 also had ruptured chordae tendineae associated with the caudal mitral valve leaflet. Bacterial endocarditis and myocardial necrosis were associated with the ruptured chordae tendineae in foals 3 and 2, respectively. Idiopathic rupture was considered in foal ...
Fregin GF.The approach to pre-purchase evaluation of the equine cardiovascular system is discussed with emphasis on cardiac auscultation and on the terminology that should be used when reporting clinical findings. Innocent cardiac murmurs and arrhythmias are contrasted with those that should be considered as reliable signs of cardiovascular disease. Ultrasonography and electrocardiography are recommended to establish baseline values for future reference, to support opinions rendered by the examining veterinarians, or to provide for diagnosis and treatment.