Topic:Exercise Test
Exercise tests are assessments used to evaluate the cardiovascular and respiratory function of horses during physical activity. These tests help in determining the fitness level, performance capacity, and potential health issues in equine athletes. Parameters such as heart rate, respiratory rate, blood lactate levels, and oxygen consumption are typically measured during these tests. Variations in these parameters can indicate the horse's adaptation to training or uncover underlying medical conditions. This page compiles peer-reviewed research studies and scholarly articles that explore the methodologies, applications, and implications of exercise tests in equine sports medicine and veterinary practice.
Characteristics of respiratory function during swimming exercise in thoroughbreds. Equine respiratory patterns during swimming were examined in five normal horses. The experiment included a preliminary warming-up stage and 6 circuits of swimming around an annular pool of a 50-meter-circumference. The horses were examined for respiratory rates, intratracheal pressures, inspiratory time (TI), expiratory time (TE), respiratory cycle (T; TI + TE), heart rates, blood lactate concentrations, hematocrit and blood gases. The respiratory rates were maintained around 25/min. Blood gas values changed significantly during swimming. The intratracheal pressures during expiration and inspi...
Electromyographic activity of the long digital extensor muscle in the exercising Thoroughbred horse. Surface electrodes were used to record electromyographic (EMG) activity of the long digital extensor muscle on the right hindlimb of 8 Thoroughbred horses for 8 s at the walk and 8 s at the trot before (unfatigued) and after (fatigued) an exercise test. The exercise test was performed on a motorised treadmill set on a 10% grade. Each test started at a speed of 6 m/s which was increased by 1 m/s each minute until the horse fatigued as indicated by its inability to keep pace with the treadmill with minimal encouragement. Observations were made on the horses prior to conditioning (untrained state...
Fluid administration attenuates the haemodynamic effect of frusemide in running horses. The effect of blood volume repletion after frusemide administration on the right atrial and pulmonary artery pressure responses of horses to exercise has not been reported. We examined right atrial and pulmonary artery pressure and plasma atrial natriuretic peptide concentration (ANP) responses to an incremental exercise test in 6 Standardbred mares. Horses were treated, in a 3 way cross over design, with isotonic saline, frusemide (1 mg/kg bwt, i.v.), and frusemide followed 3 h later by lactated Ringer's solution (12 ml/kg bwt, i.v.). Three and a half hours after saline or frusemide administr...
Effect of high-intensity exercise on arterial blood gas tensions and upper airway and cardiac function in clinically normal quarter horses and horses heterozygous and homozygous for hyperkalemic periodic paralysis. To determine the effect of exercise on arterial blood gas tensions and upper airway and cardiac function in clinically normal Quarter Horses and horses heterozygous and homozygous for hyperkalemic periodic paralysis (HYPP). ANIMALS AND PROCEDURE: 5 clinically normal Quarter Horses, and 5 heterozygous and 2 homozygous HYPP-affected horses were examined before, during, and after exercise on a high-speed treadmill. Arterial blood gas tensions, ECG, and echocardiogram were obtained prior to exercise. Upper airway endoscopy, collection of arterial blood samples, and continuous electrocardiography w...
Catecholamine and cortisol responses of horses to incremental exertion. The responses of the plasma concentrations of catecholamines and cortisol in horses to varied relative intensities of exertion were examined. The plasma concentrations of cortisol, epinephrine and norepinephrine increased significantly (p < 0.05) with exertion. The plasma cortisol concentrations at relative work intensities of 48.3% +/- 1.4%, 82.3% +/- 2.0% and 99.6% +/- 0.4% of VO2max were 114%, 124%, and 126%, respectively, of those at rest, whereas the plasma epinephrine concentrations were 239%, 772% and 3483%, and the norepinephrine concentrations were 138%, 255%, and 1121% of the valu...
Does an acute COPD crisis modify the cardiorespiratory and ventilatory adjustments to exercise in horses? The present study was conducted to understand better the mechanisms leading to the decrease in exercise capacity observed in horses suffering from chronic obstructive pulmonary disease (COPD). Five COPD horses were submitted to a standardized submaximal treadmill exercise test while they were in clinical remission or in acute crisis. Respiratory airflow, O2 and CO2 fractions in the respired gas, pleural pressure changes and heart rate were recorded, and arterial and mixed venous blood were analyzed for gas tensions, hemoglobin, and plasma lactate concentrations. O2 consumption, CO2 production,...
Chronic recombinant equine somatotropin (eST) administration does not affect aerobic capacity or exercise performance in geriatric mares. The purpose of this experiment was to test the hypothesis that chronic (89 days) administration of recombinant equine somatotropin (eST) would increase aerobic capacity and improve exercise performance in old mares. Fifteen, healthy, unfit, aged (20-26 year old) mares were randomly assigned to a treatment (eST, 12.5 mg day-1 in 3 ml glycine/manitol buffer, s.c., n = 7) or control (vehicle, 3 ml day-1, s.c., n = 8) group. Aerobic capacity and exercise performance were measured using a standardized exercise test (SET) performed on a high speed treadmill. Tests were conducted before (-21 days), d...
The use of functional indexes to evaluate fitness in Andalusian horses. The fitness of 8 Andalusian horses between 3 and 4 years of age was analysed. The animals were subjected to an exercise test on a sandy track consisting of 2 stages of different intensities. The first stage was of submaximal intensity at 4 speeds which increased progressively (4.17, 5.56, 6.94 and 8.33 m/sec.) covering a distance of 1,000 m in each level. Between each of these speeds, the horses rested for 2 min. The second stage was a maximal speed test over the same distance carried out 2 min after the ending of the maximal phase. Data of heart rate, plasma lactate concentration, velocity, P...
VO2 kinetics in the horse during moderate and heavy exercise. The horse is a superb athlete, achieving a maximal O2 uptake (approximately 160 ml . min-1 . kg-1) approaching twice that of the fittest humans. Although equine O2 uptake (VO2) kinetics are reportedly fast, they have not been precisely characterized, nor has their exercise intensity dependence been elucidated. To address these issues, adult male horses underwent incremental treadmill testing to determine their lactate threshold (Tlac) and peak VO2 (VO2 peak), and kinetic features of their VO2 response to "square-wave" work forcings were resolved using exercise transitions from 3 m/s to a below...
Nitric oxide and thermoregulation during exercise in the horse. The effect of inhibition of nitric oxide production on sweating rate (SR) and on core, rectal, and tail skin temperatures was measured in five Thoroughbred horses during exercise of variable intensity on a high-speed treadmill. A standard exercise test consisting of three canters [approximately 55% maximum O2 uptake (VO2max)], with walking (approximately 9% VO2max) and trotting (approximately 22% VO2max) between each canter, was performed twice (control or test), in random order, by each horse. N(G)-nitro-L-arginine methyl ester (L-NAME; 20 mg/kg), a competitive inhibitor of nitric oxide synth...
Heart rate variability during exercise in the horse. High heart rate variability (HRV) has been associated with more efficient autonomic control, allowing more responsivity and sensitivity to changing environmental demands. Previous results from spectral analysis of interbeat intervals of equine heart rate (HR) indicated increased HRV, reflecting more effective vagal control of the heart. This study focuses on characterizing equine HR and HRV during increasing then decreasing physical demand. A non-invasive ambulatory monitoring system continuously records HR and HRV as horses exercise on a high speed equine treadmill at increasing then decreasi...
Evaluation of young or unproven horses for potential exercise intolerance. The determination of poor performance in the young or unproven horse can be a difficult experience for the practitioner. This article describes an incremental exercise test that may be helpful in determining the cause of poor performance in horses when a complete physical examination and a lameness examination fail to elucidate the causes of poor performance. Included are values from normal yearling and 2-year-old horses that have undergone the incremental exercise test.
Testing methods for exercise intolerance in horses. The many testing methods available and the increasing sophistication of diagnostic equipment have enhanced greatly our capabilities to diagnose causes of exercise intolerance in the equine athlete during the last several years. High-speed treadmill examination has become the focus of this form of evaluation. Not all clinicians perform or have access to high-speed treadmill examinations. Testing methods that require the use of the high-speed treadmill, as well as methods that do not, are discussed.
Exercise intolerance in endurance horses. Endurance competition requires synchronism and development of metabolic and musculoskeletal systems. An understanding of the existence of performance-limiting factors may permit the detection of exercise intolerance that could lead to performance failure, fatigue, and exhaustion. New concepts for assessment of fitness have increased the understanding of individual capacities and deficiencies and the interaction of the different systems involved in exercise.
Accuracy of Accusport for measurement of lactate concentrations in equine blood and plasma. The aim of this study was to investigate correlations between lactate concentrations in equine whole blood and plasma measured with Accusport1 and Yellow Springs Instruments (YSI2) (2300) methods. The effect of packed cell volume (PCV) on the accuracy of Accusport was also investigated. Blood samples were collected from Thoroughbred horses at 5-10 min intervals after a treadmill exercise test. Blood was added to NaEDTA (for PCV measurement) and to 2 tubes containing lithium heparin anticoagulant (for lactate assays). At concentrations greater than 10 mmol/l, Accusport1 greatly underestimated t...
Effects of pentoxifylline on hemorheologic alterations induced by incremental treadmill exercise in thoroughbreds. To determine whether pentoxifylline treatment altered hematologic, rheologic, electrolyte, or blood gas test results of Thoroughbreds during submaximal treadmill exercise. Methods: 5 healthy Thoroughbreds that had raced within the past year and had no history of exercise-induced pulmonary hemorrhage. Methods: Mixed venous blood samples were obtained before exercise, at treadmill speeds of 9 and 13 m/s, and 20 minutes after exercise; hematologic, rheologic, electrolyte, and blood gas test results were determined. Results: Pentoxifylline treatment resulted in a 45% reduction in RBC filtration pr...
Use of the relationship between blood lactate and running speed to determine the exercise intensity of horses. Eight thoroughbred horses, trained for racing competition, were subjected to a standardised incremental speed test to determine the relationship between their blood lactate concentrations and running speed. Between 14 days before and 14 days after completing the standardised exercise test, the horses were timed for runs of 2000 to 6000 m. The blood lactate concentration after each run was measured and compared with the blood lactate concentration predicted from the individual horse's blood lactate-running speed relationship curve determined from the standardised exercise test. The relationship...
Modified ventilated capsule for the measurement of sweating rate in the exercising horse. Modification of a ventilated capsule technique for the measurement of sweating rate (SR) is described for application in an exercising horse. The plastic capsule was sealed against the coat of the horse. Dry air was blown through the capsule over the skin and the change in absolute humidity (g/m3) between air entering and leaving the capsule was used to calculate SR. The effect of flow rate on the response characteristics of the system was investigated and measured over a range of sweating rates in a group of horses completing a short exercise test. Repeatability of SR measurements made at 2 s...
Elemental composition of muscle at rest and potassium levels in muscle, plasma and sweat of horses exercising at 20 degrees C and 35 degrees C. In this study, 4 Standardbred geldings were exercised at 20 and 35 degrees C. The exercise test (ET) consisted of 2 exercise bouts separated by 2 h of rest in their boxes. Blood samples were taken before, during and after the second exercise bout and muscle (m. gluteus medius) biopsies were taken before the first exercise bout and after an intensive trot over 2600 m in the second exercise bout. The blood samples were analysed for plasma potassium and total plasma protein concentration (TPP) and the muscle fibres were analysed for elemental composition by x-ray microanalysis. The intracellular ...
Physiological responses in nonheat acclimated horses performing treadmill exercise in cool (20 degrees C/40% RH), hot dry (30 degrees C/40% RH) and hot humid (30 degrees C/80% RH) conditions. The aim of the present study was to determine the effect of different environmental conditions on physiological response to exercise. Four winter acclimatised, nonheat acclimated horses of different breeds were exercised at 20 degrees C/40% RH (CD), 30 degrees C/40% RH (HD) and 30 degrees C/80% RH (HH). The exercise test was designed to represent the structure and intensity of a One star Speed and Endurance test (competition exercise test [CET]). All 4 horses were able to complete the full CET (60 min + 30 min active recovery) in CD and HD, but only one horse completed the CET in HH. Two horse...
The effects of locomotor-respiratory coupling on the pattern of breathing in horses. 1. To investigate the effect of locomotor activity on the pattern of breathing in quadrupeds, ventilatory response was studied in four healthy horses during horizontal and inclined (7%) treadmill exercise at different velocities (1.4-6.9 m s(-1)) and during chemical stimulation with a rebreathing method. Stride frequency (f(s)) and locomotor-respiratory coupling (LRC) were also simultaneously determined by means of video recordings synchronized with respiratory events. 2. Tidal volume (V(T)) was positively correlated with pulmonary ventilation (V(E)) but significantly different linear regressi...
Computerized ECG recording in horses during a standardized exercise test. In the horse, it is important to make a reliable ECG recording during exercise as cardiac arrhythmia is one of the possible causes of poor performance. The purpose of the present study was to obtain a satisfactory, standardized method for ECG recording by computer during a standardized treadmill exercise test and to evaluate the procedure both in healthy and in diseased horses. Ten experienced healthy research horses were used to develop and adapt the original method (for humans) of computerized ECG recording with the Cardio Perfect software program and to obtain reference values for heart rat...
Measurement of maximal oxygen consumption of thoroughbred horses at an altitude of 1250m using open-circuit flow-through calorimetry. This study determined the maximal O2 uptake (VO2max) of Thoroughbred horses acclimatised to mild hypobaric conditions using a standard exercise test on a treadmill inclined at a 7% slope. The O2 uptake (VO2) versus speed relationship was linear below the exercise intensity required to attain VO2max. The VO2max of individual horses ranged from 143.5 to 172.6 ml/kg/min. The proportion of total variance for the VO2 versus speed relationship was greater than 0.992, and the coefficients of variation in repeated tests in individual horses ranged between 0.07 and 1.54%. The VO2 versus speed relations...
Effect of training on diverse hematologic parameters in Andalusian horses. A study has been made of the variations experienced by the hemogram and blood volume indices in 16 Andalusian horses after carrying out an exercise test of increasing intensity consisting of 3 sequences of 1000 m each, before and after being subjected to a daily exercise programme for two months. Samples were taken by external jugular vein puncture: while at rest, within the first minute of finalizing each exercise stage and at 10 and 15 minutes of recovery. Both the red blood cells and the hematocrit value showed a significant decrease in their mean values after two months training; conversel...
The effect of ambient temperature and saline loading on changes in plasma and urine electrolytes (Na+ and K+) following exercise. In this study 4 Standardbred geldings (age 3-8 years, weight 431-531 kg) were used. The horses were fed a hay and oat diet and the total sodium intake was about 32 mg/kg bwt (690 mmol/day). An exercise test (ET) which contained 3 phases was performed. Phase I consisted of 23.5 min of mainly submaximal exercise, Phase 2 of 2 h of box rest and Phase 3 of 26 min of exercise including an intensive trot over 2600 m at 90% of VO2max. The ET was repeated 3 times: the first at 20 degrees C (30-40% RH), the second at 35 degrees C (30-40% RH) and the third at 35 degrees C (30-40% RH) after a nasogastric...
Ventilatory and arterial blood gas tension adjustments to strenuous exercise in standardbreds. Five healthy, fit Standardbreds (mean +/- SEM, 490.4 +/- 15.0 kg, 4.0 +/- 0.5 years) were studied during a standardized test carried out on a treadmill. The test consisted of an 8-minute warm-up and a 9-minute exercise period (1 minute at 1.7, 4, 7, 8, 9, and 10 m/s; 2 minutes at 4 m/s; and a 1-minute walk at a 6% slope). Respiratory airflow, tidal volume (V(T)), and respiratory frequency (f) were continuously recorded, using 2 ultrasonic pneumotachographs connected to a face mask and mass spectrometer. Oxygen uptake, carbon dioxide output, and expired minute volume (V(E)) were obtained on a b...
Acid-base variables during incremental exercise in sprint-trained horses fed a high-fat diet. Seven Arabian horses performed a standard incremental exercise test on a high-speed treadmill at 6% slope then were randomly assigned to two diets, a control diet of ground hay and concentrates and a similar diet with 10% added fat (by weight). Horses were sprint-trained 4 d/wk, and two additional exercise tests were performed at 5-wk intervals. Heart rates and rectal temperatures were monitored and venous blood samples were collected at rest and at each speed increment. Whole blood was analyzed for glucose, lactate, and hemoglobin concentrations, and plasma was analyzed for pH, pCO2, albumin,...
Endoscopy of the upper respiratory tract during treadmill exercise: a clinical study of 100 horses. Endoscopy of the upper respiratory tract was performed in 100 horses during high speed treadmill exercise. Reasons for endoscopy were a history of an abnormal noise during exercise in 75 horses, poor performance in 17 horses and to evaluate the results of upper respiratory tract surgery in 8 horses. Of the 75 horses with a history of an abnormal noise during exercise the cause was determined in 67 (89%). Endoscopic abnormalities were detected at rest in 40 of these 75 horses (53%). In these 40 horses, a similar diagnosis as to the cause of the abnormal noise was made at rest and during exercis...
The effect of reversible left recurrent laryngeal neuropathy on the metabolic cost of locomotion and peak aerobic power in thoroughbred racehorses. The effect of left recurrent laryngeal neuropathy (LRLN) on the metabolic cost of locomotion (MCL) and peak aerobic power (VO2peak) was evaluated in four trained Thoroughbred racehorses. Oxygen consumption (VO2), carbon dioxide production (VCO2), venous lactate concentrations (LAC), and heart rate (HR) were measured during a treadmill exercise test (TET). Each horse performed the exercise test four times, alternating between normal upper airway function and reversibly induced LRLN. Subcutaneous infusion of 2% mepivicaine, a local anesthetic, into the region were the left recurrent laryngeal ne...
Principal component analysis, using the measurements during running and swimming test, in thoroughbred horses. To investigate whether the running exercise fitness of individual horses could be assessed by a standardized swimming exercise test, the results of multivariate analysis of the exercise parameters measured during incremental running and swimming tests were compared. Ten thoroughbred horses were subjected to different types of exercise tests on a track or in a pool, and the maximum heart rate during and the blood lactate concentration immediately after the exercise were examined. Serial exercise parameters (VLA2, VLA4, LA0, V150, V200, HRS, HRLA2, HRLA4) referred to as the indices related to th...