Analyze Diet

Topic:Heart

The equine cardiovascular system, particularly the heart, is fundamental to maintaining the health and performance of horses. The heart is responsible for pumping oxygenated blood throughout the body, supporting vital functions and physical activity. In horses, the heart's structure and function are adapted to meet the demands of both rest and exertion, with notable features such as a large cardiac output and efficient blood circulation. Conditions affecting the equine heart, such as arrhythmias, valvular diseases, and myocardial disorders, can significantly impact a horse's well-being and athletic capability. This page aggregates peer-reviewed research studies and scholarly articles that explore the anatomy, physiology, and pathophysiology of the equine heart, as well as diagnostic and therapeutic approaches to managing cardiac health in horses.
A biologically active, three-fragment complex of horse heart cytochrome c.
The Journal of biological chemistry    February 10, 1980   Volume 255, Issue 3 845-853 
Juillerat M, Parr GR, Taniuchi H.No abstract available
Ventricular defibrillation with myocardial electrodes in the dog, calf, pony, and pig.
Medical instrumentation    January 1, 1980   Volume 14, Issue 1 19-22 
Gold JH, Schuder JC, Stoeckle H.The defibrillation effectiveness of 4-msec rectangular wave shocks was evaluated using myocardial electrodes with 25-kg dogs and (nominally) 100-kg calves, ponies, and pigs as part of an evaluation of the suitability of these animals as models for automatic implanted defibrillator research. The percent success of defibrillation attempts in dogs ranged from 44% with 4-A, 6-J shocks to 93% with 8-A, 16-J shocks. The success achieved in calves with scaled electrodes was uniformly lower and reached a maximum of 28% with 23-A, 107-J shocks. Pigs defibrillated with scaled electrodes at a success lev...
Interventricular septal defect in a horse.
The Veterinary record    December 8, 1979   Volume 105, Issue 23 535 
No abstract available
[Forms of the vector loops in the atrial electrocardiogram of the horse].
Berliner und Munchener tierarztliche Wochenschrift    October 15, 1979   Volume 92, Issue 20 394-398 
Grauerholz H.No abstract available
Persistent right aortic arch associated with a persistent left ductus arteriosus and an interventricular septal defect in a horse.
Tijdschrift voor diergeneeskunde    October 15, 1979   Volume 104, Issue 20 189-194 
van der Linde-Sipman JS, Goedegebuure SA, Kroneman J.In this article a description is given of the clinical and postmortem findings of a persistent right aortic arch in association with a persistent left ductus arteriosus and a ventricular septal defect in a horse.
Assessment of myocardial function in the horse. 1. Theoretical and technical considerations.
Equine veterinary journal    October 1, 1979   Volume 11, Issue 4 244-247 doi: 10.1111/j.2042-3306.1979.tb01356.x
Brown CM, Holmes JR.The paper discusses the various parameters which are currently used in attempts to assess the contractile efficiency of the myocardium in various species. These procedures depend upon accurate recording of intracavity pressure. The response of a catheter-mounted microtransducer compared with a fluid-filled catheter manometer system is illustrated to show the advantage of the former in providing a true representation of pressure changes.
[The P-wave in the EKG of healthy horses].
Berliner und Munchener tierarztliche Wochenschrift    September 15, 1979   Volume 92, Issue 18 349-352 
Grauerholz H.No abstract available
Phonocardiography in the horse: 2. The relationship of the external phonocardiogram to intracardiac pressure and sound.
Equine veterinary journal    July 1, 1979   Volume 11, Issue 3 183-186 doi: 10.1111/j.2042-3306.1979.tb01337.x
Brown CM, Holmes JR.The paper describes observations during individual cardiac cycles on the changing pressures and sounds recorded from the various chambers of the heart and aorta, related to phonocardiograms from an external microphone hand-held over the cardiac area. The majority of the first sound appears to arise from the left side of the heart after the AV valves have closed and the second sound is a consequence of sudden deceleration of blood against already closed semilunar valves. Systolic murmurs at the aortic root may be benign from increased flow and turbulence at the peak of ejection but these may no...
Electrocardiography, heart scope and haematology of horses competing in an endurance ride.
Australian veterinary journal    June 1, 1979   Volume 55, Issue 6 247-250 
Rose RJ, Ilkiw JE, Hodgson D.Thirty-one horses competing in a 100 kilometre endurance ride had electrocardiograms recorded before and after the ride from which the heart score of each horse was calculated. Blood was also taken to determine the packed cell volume (PCV) and total plasma protein (TPP) before the ride, after 60 kilometres (mid ride) and at completion of the ride. Statistical analysis of the heart scores showed that a faster group of horses had significantly higher heart scores than either a slower group or those eliminated due to inadequate recovery of heart rate. No horses developed electrocardiogram abnorma...
[Congenital tricuspid atresia in a premature foal (author’s transl)].
Tijdschrift voor diergeneeskunde    May 15, 1979   Volume 104, Issue 10 411-416 
van Nie CJ, van der Kamp JS.A case of tricuspid atresia in a premature foal associated with large atrial septal and ventricular septal defects is reported. This anomaly is compared with other cases in horses as reported in the literature. As tricuspid atresia in horses is usually not diagnosed so that relatively few cases have been reported, a classification similar to that of human anomalies is not possible. It is suggested that the present malformation is due to abnormal development of the atrioventricular canal. The factors involved in the pathogenesis of this abnormal development are obscure.
The effect of binding ions on the oxidation of horse heart ferrocytochrome c.
Canadian journal of biochemistry    May 1, 1979   Volume 57, Issue 5 372-377 doi: 10.1139/o79-047
Peterman BF, Morton RA.The research explores how different binding ions affect the oxidation speed of horse heart ferrocytochrome c, a protein, by potassium ferricyanide at a constant ionic strength. Studying the Ion Effect […]
Tricuspid atresia in a foal and a lamb.
Zentralblatt fur Veterinarmedizin. Reihe A    April 1, 1979   Volume 26A, Issue 3 239-242 doi: 10.1111/j.1439-0442.1979.tb00670.x
van der Linde-Sipman JS, van den Ingh TS.No abstract available
[Effects of exercise and training on the heart and circulation in horses (author’s transl)].
DTW. Deutsche tierarztliche Wochenschrift    January 5, 1979   Volume 86, Issue 1 2-7 
von Engelhardt W.No abstract available
Phonocardiography in the horse: 1. The intracardiac phonocardiogram.
Equine veterinary journal    January 1, 1979   Volume 11, Issue 1 11-18 doi: 10.1111/j.2042-3306.1979.tb01285.x
Brown CM, Holmes JR.Using microtransducers, the intracardiac phonocardiogram was recorded in 8 horses from the right heart and in 6 of them also on the left side. All 4 heart sounds were recorded but not in all sites. Their timing was related to pressure events. Systolic ejection murmurs were recorded in both the pulmonary artery and the aorta. Diastolic murmurs were recorded in 2 horses with aortic regurgitation, with maximum amplitude in the left ventricle. The findings were similar to those reported in man and agree with some of the recent concepts on heart sound production.
Myocardial perfusion and function during acute right ventricular systolic hypertension.
The American journal of physiology    December 1, 1978   Volume 235, Issue 6 H628-H636 doi: 10.1152/ajpheart.1978.235.6.H628
Manohar M, Bisgard GE, Bullard V, Will JA, Anderson D, Rankin JH.Hemodynamics, myocardial function, and regional myocardial blood flow (MBF) were measured in 6 closed-chest ponies anesthetized with ketamine hydrochloride before (control) and after creation of acute right ventricular systolic hypertension (RVSH) during normoxia and isocapnic hypoxia. The right ventricular (RV) systolic pressure during each RVSH approached 90 mmHg. There were significant alterations in the pattern of total ventricular MBG distribution in favor of the RV. Because RV myocardium received proportionate increments to its endocardium as well as epicardium, it is concluded that auto...
The redox potential of horse heart cytochrome.
Biochemical and biophysical research communications    November 14, 1978   Volume 85, Issue 1 7-13 doi: 10.1016/s0006-291x(78)80003-5
Pande A, Myer YP.No abstract available
Haemodynamics in the horse: 2. Intracardiac, pulmonary arterial and aortic pressures.
Equine veterinary journal    October 1, 1978   Volume 10, Issue 4 207-215 doi: 10.1111/j.2042-3306.1978.tb02263.x
Brown CM, Holmes JR.The paper reports the changing pressure values during the cardiac cycle recorded from various chambers of the heart and great vessels using 2 catheter-mounted transducers, 9 cm apart. Pulse pressures are calculated. Transvalval pressure differences are determined taking account of the effect of hydrostatic pressure between the 2 sensors. The effects of some valvular lesions and arrhythmias and of changes in intrathoracic pressure are also described.
Heart rate during a defined exercise test in horses with heart and lung diseases.
Equine veterinary journal    October 1, 1978   Volume 10, Issue 4 235-242 doi: 10.1111/j.2042-3306.1978.tb02269.x
Maier-Bock H, Ehrlein HJ.During a gradually increasing exercise test heart rates were determined in healthy animals and in 2 groups of sick horse. These included 31 animals with a chronic pulmonary disorder and 5 with chronic heart disease. The alteration in heart rate was correlated with the clinical signs exhibited. In the horses with lung disease there was a close correlation between the stage of the diseases and the heart rate during the exercise test. In 3 animals with heart valve disease there was no apparent difference in heart rate compared with healthy horses. On the other hand the exercising heart rate of ho...
Haemodynamics in the horse: 3. Duration of the phases of the cardiac cycle.
Equine veterinary journal    October 1, 1978   Volume 10, Issue 4 216-223 doi: 10.1111/j.2042-3306.1978.tb02265.x
Brown CM, Holmes JR.The paper reports observations on the duration of various phases of the cardiac cycle using a bipole ECG record as a time base from which to measure the timing of pressure changes in the chambers of the heart and great vessels. From the findings the likely sequence of mechanical events during the cardiac cycle in the atria and ventricles is described.
Haemodynamics in the horse: 1. Pressure pulse contours.
Equine veterinary journal    July 1, 1978   Volume 10, Issue 3 188-194 doi: 10.1111/j.2042-3306.1978.tb02257.x
Brown CM, Holmes JR.Using a catheter with 2 transducers, one mounted at the tip and one 9 cm proximal to it, enabled transvalval pressure waveforms to be recorded in 8 horses. A simultaneous electrocardiogram acted as a time base. The changing waveforms produced in the chambers of the heart and great vessels are described and related to the events of the cardiac cycle. The effect of second degree AV block, ectopic beats, a pan diastolic murmur and chronic obstructive pulmonary disease are described.
Chronic lead poisoning in horses.
American journal of veterinary research    June 1, 1978   Volume 39, Issue 6 961-964 
Dollahite JW, Younger RL, Crookshank HR, Jones LP, Petersen HD.Lead acetate was fed to 4 groups of 2 horses each to study chronic lead intoxication. A 5th group of 3 horses was maintained as controls. The leas was fed in capsules, with the minimum dosage of 6.25 mg/kg/day of lead as lead acetate (group I). The dose was increased from group I through group IV in an approximate geometric series, with each group being given about 125% of the dose given the previous group. These doses were given for 105 days, a period designated as phase 1. Since clinical signs were not observed after 105 days, the doses were increased and fed for an additional 190 days (days...
Cardiopathological observations on histopathogenesis of wandering pacemaker in horses.
Nihon juigaku zasshi. The Japanese journal of veterinary science    April 1, 1978   Volume 40, Issue 2 131-140 doi: 10.1292/jvms1939.40.131
Kiryu K, Kaneko M, Satoh H.Histopathololgical observations were performed on the heart and cardiac nervous system of 5 horses affected with wandering pacemaker. The histopathological lesions common to all the animals were as follows: (1) Focal fibrosis in the atrial myocardium just beneath the subendocardium and/or in the endo- and subendocardium, and existence of atrial Purkinje-like fibers within the fibrotic lesions, (2) Microvascular altetation, characterized by edematous-loosening and/or fibrous swelling of the walls of the small and minute arteries, in both the atria, (3) Edema in the intracadiac nerves of both th...
A phonocardiographic study of equine heart sounds.
Australian veterinary journal    April 1, 1978   Volume 54, Issue 4 161-170 doi: 10.1111/j.1751-0813.1978.tb02439.x
Vanselow B, McCarthy M, Gay CC.The occurrence and timing of heart sounds were examined from phonocardiograms taken from the mitral, aortic and tricupsid recording areas in each of 18 horses. 10 sound events could be identified with each cardiac cycle. Atrial contraction produced up to 3 sound events. The first heart sound consisted of 4 components whereas the second sound was single. Two sound events were associated with the 3rd heart sound in early diastole. The occurrence of third and fourth heart sound components varied between horses and between recording areas. The mitral recording area was considered most satisfactory...
Tricuspid atresia in a foal.
Journal of the American Veterinary Medical Association    April 1, 1978   Volume 172, Issue 7 825-830 
Button C, Gross DR, Allert JA, Kitzman JV.An Arabian crossbred foal was examined because of a suspected congenital cardiac anomaly. There was a grade V/V crescendo-decresendo holosystolic murmur and thrill in the left 4th intercostal space. The foal was slightly cyanotic and polycythemic. Electrocardiography suggested left ventricular hypertrophy. Angiography and cardiac and vascular pressure recordings led to a diagnosis of pulmonic stenosis. The foal died after cardiac bypass and corrective surgery. Postmortem examination revealed an enlarged right atrium, atresia of the tricuspid orifice, a large, fenestrated patent foramen ovale, ...
Artifact production with micromanometers used to record intracardiac pressure and sound.
Catheterization and cardiovascular diagnosis    January 1, 1978   Volume 4, Issue 3 275-282 doi: 10.1002/ccd.1810040309
Brown CM, Holmes JR.In horses experimental right and left heart catheterization using a catheter with two microtransducers 9 cm apart, usually in a transvalval position produced pressure and sound artifacts that confounded the diagnosis. Most were probably due to malpositioning resulting in movement through a valve during recording or impingement on the valve cusps or the chordae tendineae or lodgement in the apex of the heart. The recognition of these artifacts is particularly important in studies of large animals in which catheter siting cannot be monitored by radiography.
Paroxysmal atrial fibrillation in a racehorse.
Australian veterinary journal    November 1, 1977   Volume 53, Issue 11 545-549 doi: 10.1111/j.1751-0813.1977.tb07943.x
Rose RJ, Davis PE.A 4-year-old thoroughbred stallion with a history of loss of racing form was studied over a period of approximately 7 months. At the initial examination he showed positive T waves in 1 chest lead and wandering of the pacemaker. This was followed by an episode of paroxysmal atrial fibrillation which disappeared spontaneously and was replaced by significant T wave changes in all the chest leads. During a period when these changes persisted, there was progressive lengthening of the P wave and the P-R interval. Because the last ECG showed evidence of intra-atrial block, first degree A-V block and ...
Prognosis of equine cardiac conditions.
Equine veterinary journal    October 1, 1977   Volume 9, Issue 4 181-182 doi: 10.1111/j.2042-3306.1977.tb04022.x
Holmes JR.No abstract available
Cardiological problems in equine medicine.
Equine veterinary journal    October 1, 1977   Volume 9, Issue 4 173-175 doi: 10.1111/j.2042-3306.1977.tb04018.x
Littlewort MC.This paper outlines the major problems in evaluating and assessing prognosis in horses with minor cardiac abnormalities. It emphasises that progress will only be made if adequate data on the "natural history" of equine cardiac disease can be collected. This will necessitate a long-term study of suitable cases and will require the collaboration of specialist institutions and general practitioners if it is to be successful.
Pacing techniques in assessing cardiac function in the horse.
Equine veterinary journal    October 1, 1977   Volume 9, Issue 4 178-180 doi: 10.1111/j.2042-3306.1977.tb04021.x
O'Callaghan MW.The problem of transitory cardiac arrhythmias in equidae is discussed particularly with regard to the referral of suspect cases to specialist institutions for second opinion. Recently developed electro-stimulation techniques designed to uncover problem arrythmias, are briefly described and their potential in the analysis of cardiac electrical function under varying conditions is reviewed. The author cautions on the too rapid evaluation of the techniques for this purpose while remaining optimistic of the potential of electro-stimulation in the objective analysis of cardiac electric parameters.
Studies on left ventricular isotonic function in conscious and anaesthetized ponies.
The British veterinary journal    September 1, 1977   Volume 133, Issue 5 446-453 doi: 10.1016/s0007-1935(17)33983-0
Hillidge CJ, Lees P.The effects of thiopentone-halothane and thiopentone-ether anaesthesia on left ventricular isotonic function were assessed in Welsh Mountain ponies from measurements of left ventricular stroke work, minute work, stroke power, mean ejection rate and tension-time index. All of these variables were affected similarly during anaesthesia, an initial marked reduction being followed by a progressive return towards control levels in the later stages of anaesthesia. Quantitative differences between the effects of each agent were evident, the depression which occurred during halothane anaesthesia bei...
1 24 25 26 27 28 31