Imaging techniques in horses encompass a range of diagnostic tools used to visualize the internal structures and systems of equine patients. These techniques assist in the diagnosis, monitoring, and treatment planning of various conditions affecting horses. Common imaging modalities include radiography (X-rays), ultrasonography, magnetic resonance imaging (MRI), and computed tomography (CT). Each technique offers unique advantages in terms of resolution, depth of penetration, and the type of tissues that can be examined. For instance, radiography is frequently used for assessing bone structures, while ultrasonography is often employed for soft tissue evaluation. MRI and CT provide detailed cross-sectional images, aiding in the assessment of complex anatomical regions. This page compiles peer-reviewed research studies and scholarly articles that explore the application, advancements, and comparative efficacy of imaging techniques in equine veterinary medicine.
Pirie CG, LoPinto AJ, Tenney WA.OBJECTIVE To assess and compare 2 injection techniques for conducting ocular anterior segment indocyanine green angiography (ASICGA) and sodium fluorescein (SF) angiography in horses. ANIMALS 3 healthy adult female horses (age range, 19 to 25 years). PROCEDURES Horses were sedated, jugular catheters were placed, and manual restraint was used to ensure proper positioning for the angiography procedure. Two injection techniques (IV and intra-arterial) were performed for each horse 1 week apart. Intravenous injections of 0.25% indocyanine green (ICG; 50 mg) and 10% SF (10 mg/kg) were administered ...
Limone LE, Baratt RM.This step-by-step article describes radiographic imaging of the horse's teeth and paranasal sinuses with standard radiographic equipment. Obtaining radiographs of the horse's skull that are of diagnostic quality can be challenging. The descriptions offered in this article can help practitioners become more comfortable with obtaining diagnostic images, which will improve recognition of radiographic signs of dental and paradental pathology.
Gialletti R, Marchegiani A, Valeriani T, Nannarone S, Beccati F, Fruganti A, Laus F.To describe the association of clinical and ultrasonographic (US) findings in horses affected by visual impairments, to estimate the most frequent ultrasonographic alteration as well importance and limits of US as a part of ophthalmic evaluation in equine patients. Methods: One-hundred-forty-five horses referred to the Veterinary Teaching Hospitals of the University of Perugia and Camerino for ocular problems were submitted to ophthalmic examination and ocular ultrasound. The following group of abnormalities was established: corneal alteration, cataract, synechiae, iris prolapse, anterior cham...
Aarsvold S, Solano M, Garcia-Lopez J.Systemic administration of gadolinium contrast medium is common in small animals to increase lesion conspicuity and determine vascularisation of lesions identified with magnetic resonance imaging (MRI); however, the large volume required for systemic administration limits its use in horses. Objective: The purpose of this study was to assess the feasibility of administering a low dose of contrast medium via venous regional limb perfusion. Methods: Prospective clinical study. Methods: Distal limbs of 26 horses (one limb per horse) were imaged with MRI before and after administration of 5 mL of g...
Barton AK, Schulze T, Doherr MG, Gehlen H.Bronchoalveolar lavage (BAL) and thoracic radiography are routinely performed diagnostic procedures. We hypothesized that BAL increases the interstitial opacity of caudoventral and caudodorsal thoracic radiographs. Fifty-three horses, including 8 clinic owned and 45 from a referral hospital population, were classified as healthy controls (n = 12), severe equine asthma (recurrent airway obstruction, n = 12) or mild-to-moderate equine asthma (inflammatory airway disease, n = 21) based on the results of a clinical scoring system. Eight were excluded due to different diagnoses and poor image quali...
Nelson BB, Kawcak CE, Barrett MF, McIlwraith CW, Grinstaff MW, Goodrich LR.Articular cartilage is a critical joint tissue and its evaluation remains a diagnostic challenge in horses. Coupled with a poor capacity for healing, early degenerative changes in articular cartilage are difficult to characterise using routine diagnostic imaging evaluations. Both computed tomography (CT) and magnetic resonance imaging (MRI) provide volumetric joint assessment and highlight morphological and quantitative properties of articular cartilage, improving assessment of this essential tissue. While the use of CT and MRI for joint evaluation is not new, there still remains a shortage of...
Biggi M, Dyson SJ.OBJECTIVE To use high-field and low-field MRI to describe the anatomy of the proximal portion of the tarsal region (proximal tarsal region) of nonlame horses. SAMPLE 25 cadaveric equine tarsi. PROCEDURES The proximal portion of 1 tarsus from each of 25 nonlame horses with no history of tarsal lameness underwent high-field (1.5-T) and low-field (0.27-T) MRI. Resulting images were used to subjectively describe the anatomy of that region and obtain measurements of the collateral ligaments of the tarsocrural joint. RESULTS Long and short components of the lateral and medial collateral ligaments of...
Cribb NC, Arroyo LG.Diagnostic ultrasonography has been used as a test to determine the presence or absence of gastrointestinal disease in horses and foals. General techniques and anatomic landmarks are reviewed. Many clinical reports that have included diagnostic ultrasound as part of their diagnostic process and accuracy studies are necessary to determine the usefulness of diagnostic ultrasound in clinical practice.
Labens R, Daniel C, Hall S, Xia XR, Schwarz T.Early diagnosis of cartilage disease at a time when changes are limited to depletion of extracellular matrix components represents an important diagnostic target to reduce patient morbidity. This report is to present proof of concept for nanoparticle dependent cartilage barrier imaging in a large animal model including the use of clinical magnetic resonance imaging (MRI). Conditioned (following matrix depletion) and unconditioned porcine metacarpophalangeal cartilage was evaluated on the basis of fluorophore conjugated 30 nm and 80 nm spherical gold nanoparticle permeation and multiphoton lase...
Alzola Domingo R, Riggs CM, Gardner DS, Freeman SL.Superficial digital flexor tendon (SDFT) tendinopathy is an important musculoskeletal problem in horses. The study objective was to validate an ultrasonographic scoring system for SDFT injuries. Ultrasonographic images from 14 Thoroughbred racehorses with SDFT lesions (seven core; seven diffuse) and two controls were blindly assessed by five clinicians on two occasions. Ultrasonographic parameters evaluated were: type and extent of the injury, location, echogenicity, cross-sectional area and longitudinal fibre pattern of the maximal injury zone (MIZ). Inter-rater variability and intra-rater re...
Montgomery JB, Bracamonte JL, Alam MW, Khan AH, Mohammed SK, Wahid KA.This pilot study assessed wireless capsule endoscopy in horses. Image transmission was achieved with good image quality. Time to exit the stomach was variable and identified as one limitation, together with gaps in image transmission, capsule tumbling, and inability to accurately locate the capsule. Findings demonstrate usefulness and current limitations. Cette étude pilote a évalué l’endoscopie par capsule chez les chevaux. La transmission d’images a permis d’obtenir une bonne qualité d’image. Le temps jusqu’à la sortie de l’estomac était variable et identifié comme une li...
Tomich LM, Pieper JB, Stern AW.Dermoscopy is a noninvasive diagnostic technique that allows visualization of structures of the superficial dermis not visible with the naked eye. Objective: To assess the usefulness and applicability of dermoscopy for evaluation of healthy equine skin. Methods: Twelve healthy horses from a research herd. Methods: Five regions (cheek, lateral neck, dorsum, flank and abdomen) were examined with contact dermoscopy using both nonpolarized and polarized light at both 17-fold and 24-fold magnification. These findings were compared to histological features of skin biopsies cut both longitudinally an...
Kovac M, Litvin YA, Aliev RO, Zakirova EY, Rutland CS, Kiyasov AP, Rizvanov AA.In this clinical study, for the first time we used the direct gene therapy to restore severe injuries of the suspensory ligament branch and superficial digital flexor tendon in horses (). We injected the plasmid DNA encoding two therapeutic species-specific growth factors: vascular endothelial growth factor 164 and fibroblast growth factor 2 at the site of injury in the suspensory ligament branch and tendon. Treatment effects were evaluated with the use of clinical observation and ultrasound imaging during a period of a few months. We showed that gene therapy used within a period of 2-3 mont...
Gilger BC.This article reviews the literature for studies describing advanced imaging of the equine eye as a reference for practitioners to help in the selection of image modalities, describe how to use the instruments, and help interpret the image findings. Indications for, technique of, and image interpretation of advanced image modalities such as ultrasound, computed tomography, MRI, optical coherence tomography, confocal microscopy, and angiography are reviewed. The article is organized anatomically, not by instrument, so that the reader will be able to quickly research ways to image specific diseas...
Sarin JK, Rieppo L, Brommer H, Afara IO, Saarakkala S, Töyräs J.Conventional arthroscopic evaluation of articular cartilage is subjective and poorly reproducible. Therefore, implementation of quantitative diagnostic techniques, such as near infrared spectroscopy (NIRS) and optical coherence tomography (OCT), is essential. Locations (n = 44) with various cartilage conditions were selected from mature equine fetlock joints (n = 5). These locations and their surroundings were measured with NIRS and OCT (n = 530). As a reference, cartilage proteoglycan (PG) and collagen contents, and collagen network organization were determined using quantitative ...
Geiger SM, Reich E, Böttcher P, Grund S, Hagen J.Biplane high-speed fluoroscopy is a new method for gait analysis of the equine distal extremity. This is the first study validating the noninvasive tracking possibilities (Autoscoping and Scientific Rotoscoping) taking equine anatomy into account. Objective: To determine the resolution with which Autoscoping and Scientific Rotoscoping depict motion of the equine phalanges in comparison to the invasive gold standard marker-based registration. Methods: Comparative ex vivo study. Methods: In 5 distal extremities of slaughtered ponies, 3 or 4 tantalum beads with 1 mm diameter were implanted in e...
Spriet M, Espinosa P, Kyme AZ, Phillips KL, Katzman SA, Galuppo LD, Stepanov P, Beylin D.Positron emission tomography (PET) is a cross-sectional, functional imaging modality that has recently become available to the horse. The use of 18 F-sodium fluoride (18 F-NaF), a PET bone tracer, has not previously been reported in this species. Objective: To assess the feasibility of 18 F-NaF PET in the equine distal limb and explore possible applications in the horse in comparison with other imaging modalities. Methods: Exploratory descriptive study involving three research horses. Methods: Horses were placed under general anaesthesia prior to intravenous (i.v.) administration of 1.5 MBq/kg...
Englisch LM, Kostrzewa K, Kopke S, Failing K, Staszyk C.Hypsodont equine cheek teeth possess large dental crowns, resting partly in the bony alveolus. Over a horse's life cheek teeth erupt continuously to compensate for occlusal wear of 3-4 mm per year. Parts of the crown initially resting in the bony alveolus become progressively exposed at the occlusal surface with time. Hitherto, it is unclear whether the typical structure of the equine occlusal surface, composed of a complex arrangement of enamel, dentin and cementum, remains constant or undergoes structural changes with age. Therefore, we tested the hypothesis that the occlusal surface composi...
Lorenzo JM, Guedes CM, Agregán R, Sarriés MV, Franco D, Silva SR.This work represents the first contribution for the application of the video image analysis (VIA) technology in predicting lean meat and fat composition in the equine species. Images of left sides of the carcass (n=42) were captured from the dorsal, lateral and medial views using a high-resolution digital camera. A total of 41 measurements (angles, lengths, widths and areas) were obtained by VIA. The variation of percentage of lean meat obtained from the forequarter (FQ) and hindquarter (HQ) carcass ranged between 5.86% and 7.83%. However, the percentage of fat (FAT) obtained from the FQ and H...
Groom LM, White NA, Adams MN, Barrett JG.Lesions of the distal deep digital flexor tendon (DDFT) are frequently diagnosed using MRI in horses with foot pain. Intralesional injection of biologic therapeutics shows promise in tendon healing; however, accurate injection of distal deep digital flexor tendon lesions within the hoof is difficult. The aim of this experimental study was to evaluate accuracy of a technique for injection of the deep digital flexor tendon within the hoof using MRI-guidance, which could be performed in standing patients. We hypothesized that injection of the distal deep digital flexor tendon within the hoof coul...
Martel G, Forget C, Gilbert G, Richard H, Moser T, Olive J, Laverty S.Noninvasive imaging tools are needed to screen foal femoropatellar joints to detect subclinical osteochondrosis lesions due to focal failure of endochondral ossification to enhance early management to optimise intrinsic healing events. Recently investigations employing 3T susceptibility-weighted magnetic resonance imaging (3T SWI MRI) and CT have demonstrated their capacity for early osteochondrosis diagnosis, but these technologies are not practical for field screening. We postulate that ultrasonography is a valuable field tool for the detection of subclinical osteochondrosis lesions. Objecti...
Nelson BB, Goodrich LR, Barrett MF, Grinstaff MW, Kawcak CE.The use of contrast media in computed tomography (CT) and magnetic resonance imaging (MRI) is increasing in horses. These contrast-enhanced imaging techniques provide improved tissue delineation and evaluation, thereby expanding diagnostic capabilities. While generally considered safe, not all contrast media exhibit the same safety profiles. The safety of contrast media use and descriptions of adverse events occurring in horses are sparsely reported. This review summarises the reported evidence of contrast media use and adverse events that occur in horses, with added contribution from other ve...
Mackenzie CJ, Haggett EF, Pinchbeck GL, Marr CM.Ultrasonography of the atlanto-occipital (AO) space may be useful as a non-invasive diagnostic tool in neonatal foals. The aims of the study were establish a range of values for ultrasonographic measurements of the AO space in healthy Thoroughbred foals and to compare these variables in healthy foals with foals diagnosed with neonatal maladjustment syndrome (NMS). Ultrasonography of the AO space was performed on 38 healthy Thoroughbred foals and 28 Thoroughbred foals with NMS≤4days of age. Transverse image spinal cord height (P=0.001), width (P<0.001) and spinal cord cross sectional area ...
Khairuddin NH, Sullivan M, Pollock PJ.In horses, the extracranial and intracranial pathway of the internal carotid artery has been described. The extracranial pathway of the internal carotid artery begins at the carotid termination and runs on the dorsal surface of the medial compartment of the guttural pouch. Thereafter the internal carotid artery passes through the foramen lacerum to continue intracranially, forming part of the rostrolateral quadrants of the cerebral arterial circle (Circle of Willis). The objectives of this study were to define and record the anatomy of the carotid arterial tree and the internal carotid artery ...
Dotzel AR, Baratt RM.The use of oral endoscopy can be very beneficial in that it helps the clinician to perform a more thorough oral examination. However, due to the high cost, most commercially available equine oral endoscopy systems have been out of reach for clinicians who practice equine dentistry outside a large hospital setting. This article details how to set up an oral endoscopy system that can be used on equine patients either in an ambulatory practice or in a hospital setting. The system is more cost-effective than most other systems currently on the market without sacrificing functionality or image qual...
Soroko M, Howell K, Dudek K.The aim of the study was to describe the dependence on ambient temperature of distal joint temperature at the forelimbs of racehorses. The study also investigated the influence of differing ambient temperatures on the temperature difference between joints: this was measured ipsilaterally (i.e. between the carpal and fetlock joints along each forelimb) and contralaterally (i.e. between the same joints of the left and right forelimbs). Sixty-four healthy racehorses were monitored over 10 months. At each session, three thermographic images were taken of the dorsal, lateral and medial aspects of t...
Eberhardt C, Schwarzwald CC.Focused cardiac ultrasound examination (FoCUS) is rapidly emerging for point-of-care cardiac assessment using hand-carried ultrasound (HCU) devices. A specific FoCUS protocol for horses and adequate training guidelines currently are not available. Objective: To gain knowledge about the training necessary to become proficient in performing FoCUS using a HCU device. Methods: Three healthy Warmblood horses were used for practical training of veterinarians and veterinary students in equine focused cardiac ultrasound (eFoCUS). Methods: Prospective educational study. An eFoCUS protocol and 1-day tra...
Ness SL, Bain FT, Zantingh AJ, Gaughan EM, Story MR, Nydam DV, Divers TJ.Visualization of colonic mesenteric vasculature during transabdominal ultrasonographic examination of horses with colic can be a predictor of right dorsal displacement of the large colon or 180° large colon volvulus, or both. Medical records of 82 horses having had surgical treatment of colic and having received a transabdominal ultrasonographic examination on admission were reviewed. Colonic mesenteric vessels were sonographically identified coursing laterally on the right side of the abdomen in 24 of the 82 cases. Horses with colonic vessels identified on ultrasound were 32.5 times more lik...
Englisch LM, Kostrzewa K, Kopke S, Failing K, Staszyk C.Hypsodont equine cheek teeth possess large dental crowns, resting partly in the bony alveolus. Over a horse's life cheek teeth erupt continuously to compensate for occlusal wear of 3-4 mm per year. Parts of the crown initially resting in the bony alveolus become progressively exposed at the occlusal surface with time. Hitherto, it is unclear whether the typical structure of the equine occlusal surface, composed of a complex arrangement of enamel, dentin and cementum, remains constant or undergoes structural changes with age. Therefore, we tested the hypothesis that the occlusal surface composi...
Sherlock CE, Mair TS.Recognition of artefacts is an essential component of the accurate interpretation of diagnostic images. This study aimed to investigate the presence of magic angle effect in the superficial digital flexor tendon (SDFT) in the equine proximal pastern region. The proximal pastern of four cadaver limbs was imaged using a 0.27 Tesla magnet with high-resolution sequences that are commonly utilised in clinical equine practice. The limbs were imaged in a neutral position and positions that simulated the horse 'leaning in', 'leaning out' and having internal and external rotation of the distal limb. Si...
Spriet M, Mai W, McKnight A.Increased signal intensity in one of the collateral ligaments of the distal interphalangeal (DIP) joint of sound horses in images acquired using a low-field magnet with vertical orientation of the magnetic field was investigated as a possible manifestation of the magic angle effect. Three isolated equine digits were imaged using the following pulse sequences: (1) spin echo TI, (2) turbo spin echo proton density and T2, and (3) 3D gradient echo T1, in different positions by mildly changing the orientation of the long axis of the digit, in the dorsal plane, relative to the magnetic field. The si...
Khairuddin NH, Sullivan M, Pollock PJ.To record the angiographic anatomy of the equine internal carotid artery (ICA) using angiography techniques. Methods: In vitro descriptive study. Methods: Equine cadaver specimens (n = 50). Methods: Head and neck specimens from horses of mixed breed, age, sex, and use without a history of guttural pouch disease had carotid and cerebral angiography using conventional (n = 7) and rotational angiography (43). Angiographic findings were verified by arterial latex casts. Results: Variation in ICA anatomy was categorized into 4 groups: (1) the internal carotid and occipital arteries arising ...
Puhakka PH, Te Moller NC, Tanska P, Saarakkala S, Tiitu V, Korhonen RK, Brommer H, Virén T, Jurvelin JS, Töyräs J.Background and purpose - Arthroscopic estimation of articular cartilage thickness is important for scoring of lesion severity, and measurement of cartilage speed of sound (SOS)-a sensitive index of changes in cartilage composition. We investigated the accuracy of optical coherence tomography (OCT) in measurements of cartilage thickness and determined SOS by combining OCT thickness and ultrasound (US) time-of-flight (TOF) measurements. Material and methods - Cartilage thickness measurements from OCT and microscopy images of 94 equine osteochondral samples were compared. Then, SOS in cartilage w...
Faulkner JE, Broeckx BJG, Martens A, Raes E, Haardt H, Vanderperren K.Metal artifacts in CT negatively impact the evaluation of surgical implants and the surrounding tissues. The aim of this prospective experimental study was to evaluate the ability of a single energy metal artifact reduction (SEMAR™, Canon) algorithm and virtual monoenergetic (VM) dual-energy CT (DECT) scanning techniques to reduce metal artifacts from stainless steel screws surgically inserted into the equine proximal phalanx. Seven acquisitions of 18 cadaver limbs were performed on a Canon Aquilion One Vision CT scanner (Helical +SEMAR, Volume +SEMAR, Standard Helical, Standard Volume and V...
Lascola KM, Joslyn S.Diagnostic imaging plays an essential role in the diagnosis and monitoring of lower respiratory disease in neonatal foals. Radiography is most widely available to equine practitioners and is the primary modality that has been used for the characterization of respiratory disease in foals. Computed tomography imaging, although still limited in availability to the general practitioner, offers advantages over radiography and has been used diagnostically in neonatal foals with respiratory disease. Recognition of appropriate imaging protocols and patient-associated artifacts is critical for accurate...
Claerhoudt S, Bergman EH, Saunders JH.This study describes a detailed computed tomographic reference of the normal equine foot. Ten forefeet of five adult cadavers, without evidence of orthopaedic disease, were used. Computed tomography (CT) was performed on all feet. Two-millimetre thick transverse slices were obtained, and sagittal and dorsal planes were reformatted. The CT images were matched with the corresponding anatomic slices. The phalanges and the distal sesamoid bone showed excellent detail. The extensor and flexor tendons (including their attachments) could be clearly evaluated. The collateral (sesamoidean) ligaments co...
Gacem S, Bompart D, Valverde A, Catalán J, Miró J, Soler C.This study was conducted to determine optimum image capture frame rates (FRO) when there was evaluation of different types of counting chambers used for CASA-Mot determinations of stallion sperm motility. Sperm VCL was determined at frame rates of 25-250 f/s in: 1) Spermtrack® (Spk) 10 and 20 chambers (drop displacement-type chambers 10 and 20 μm-deep respectively; and 2) ISAS®D4C10, ISAS®D4C20 (10 and 20 μm-deep respectively) and ISAS®D4C20 L (20 μm-deep) capillary loaded chambers. Values for different sperm kinematic variables were determined using each chamber at 250 f/s, whi...
Lascola KM, Clark-Price SC, Joslyn SK, Mitchell MA, O'Brien RT, Hartman SK, Kline KH.OBJECTIVE To evaluate use of single manual alveolar recruitment maneuvers (ARMs) to eliminate atelectasis during CT of anesthetized foals. ANIMALS 6 neonatal Standardbred foals. PROCEDURES Thoracic CT was performed on spontaneously breathing anesthetized foals positioned in sternal (n = 3) or dorsal (3) recumbency when foals were 24 to 36 hours old (time 1), 4 days old (time 2), 7 days old (time 3), and 10 days old (time 4). The CT images were collected without ARMs (all times) and during ARMs with an internal airway pressure of 10, 20, and 30 cm HO (times 2 and 3). Quantitative analysis of CT...
McKnight AL, Manduca A, Felmlee JP, Rossman PJ, McGee KP, Ehman RL.Magnetic resonance imaging (MRI) of the distal extremities of the standing, sedated horse would be desirable if diagnostic quality images could be obtained. With the availability of extremity and special purpose magnet designs on the market, a system to safely accommodate the standing horse may gain increasing popularity. This paper considers the issue of motion that will need to be addressed to achieve successful, diagnostic quality images. The motion of the carpus and tarsus of five standing, sedated horses was quantified. The obtained motion records were then used to induce motion in cadave...
Tóth P, Horváth C, Ferencz V, Nagy K, Gligor N, Szenci O, Bodó G.In the first part of this methodological study eleven metacarpi of 9 skeletally normal horses were examined from 4 directions by dual energy x-ray absorptiometry (DXA). The differences between the dorsopalmar-palmarodorsal and lateromedial-mediolateral (opposite sites) bone mineral density (BMD) values were found to be nonsignificant. In the second part of the study the precision of the Norland XR-26 densitometer was tested by measuring 34 metacarpal bones and 34 proximal phalanges, each of them three times, from a single direction. The difference between the individual measurements of the fir...
Pollaris E, Staszyk C, Proost K, Boone MN, Josipovic I, Pardon B, Vlaminck L.Fissures on the occlusal surface of equine cheek teeth are commonly encountered during oral examination. Generally, their presence is considered abnormal but their aetiopathogenesis and clinical impact on pulp disease is still undetermined. The aims of this research were to study the extent of occlusal cheek teeth fissures using high-resolution X-ray computed tomography (μCT) imaging and their histological characteristics. Twenty-seven teeth (of 15 horses) were scanned using μCT imaging to analyse fissure extent. Histological examination of a subset of teeth (n=7) was performed. Forty-three ...
Hartl B, Egerbacher M, Kneissl SM. Detailed radiological evaluation of the normal hyoid apparatus by computed tomography (CT) has not yet been conducted. Thus, it is unclear what type of junction connects the different parts of the equine hyoid apparatus. To describe the normal CT anatomy of the equine hyoid apparatus, and to determine the junction type that connects the different parts of the hyoid apparatus. Combination of retrospective study and prospective cadaver study. The medical records of horses that underwent head CT scans from 2009 to 2018 were retrieved. Inclusion criteria for the CT scans were visibility of at ...
Hoffmann KL, Wood AK, McCarthy PH.Sonographic and anatomic observations were made of the kidneys of 23 Thoroughbreds or Standardbreds. In an in vitro study of 16 horses, precise correlations were established between the gross anatomic features of the kidneys and their sonographic appearance in images obtained in dorsal, sagittal, transverse, and transverse oblique anatomic planes. The renal cortex had a uniformly mottled echogenicity, and the renal medulla was relatively hypoechogenic, compared with the cortex. Acoustic anisotropy was observed in the cortex and medulla of the cranial and caudal extremities of each kidney. The ...
Jann HW, Rains JR.The location and size of 11 retained testes were accurately determined ultrasonographically. There was 100% correlation between the location of the testis determined by ultrasound vs that determined by surgery. Testicular size determined presurgically in all cases closely approximated the actual size obtained by gross measurement of the excised testis. The cryptorchid testicular echotexture was less dense than that of the normal descended testicles, but was easily identified. Ultrasonographic evaluations were completed by use of an ultrasound base unit with attached 5-MHz transrectal transduce...
Ferrari M, Weller R, Pfau T, Payne RC, Wilson AM.The purpose of this work was to evaluate the accuracy and precision of a freehand three-dimensional (3-D) ultrasonography system in the determination of lesion volume in tendons. The accuracy and precision of a 3-D ultrasonography system was assessed by performing repeated measurements on a phantom of known volume. Volume measurements of tendon lesions performed with 3-D ultrasonography were compared with measurements based on a series of two-dimensional (2-D) ultrasound (US) scans and to direct measurements from dissections. A novel method for the creation of tendon lesions in vitro was devel...
Perez-Jimenez EE, Biedrzycki AH, Morton AJ, McCarrel TM.To determine the influence of a custom 3D-printed guide for placement of cortical bone screws in the equine navicular bone. Methods: Ex vivo study. Methods: Eight pairs of normal adult equine forelimbs. Methods: A 3.5 × 55 mm cortical screw was placed in the longitudinal axis of each intact navicular bone. Screws were placed with a 3D-printed guide (3D) in one bone and with a traditional aiming device (AD) in the contralateral bone within each pair. Duration of surgery and the number of fluoroscopy images were compared between techniques. Screw placement was subjectively evaluated by gros...
Beccati F, Santinelli I, Nannarone S, Pepe M.OBJECTIVE To determine the influence of various neck positions on cervical vertebral radiographic measurements in horses. ANIMALS 18 client-owned horses examined for lameness but free of cervical disease. PROCEDURES Laterolateral radiographs of the cervical vertebrae from C1 through T1 were acquired for each horse in 3 neck positions (low, neutral, and high). Minimum sagittal diameter, intravertebral sagittal diameter (intra-VSD) ratio, inter-VSD ratio, length of the articular processes joint ratio, vertebral alignment angle, and vertebral fossa angle were measured at each segment in each neck...
Voros K, Holmes JR, Gibbs C.Two-dimensional echocardiography (2DE) was performed on 22 unsedated Thoroughbred and part Thoroughbred horses weighing between 411 and 650 kg to establish normal reference values for 2DE measurements. Animals stood during examinations performed with a 3.5 MHz mechanical sector transducer using various transducer positions and tomographic planes. Right ventricular diameter (RVD), ventricular septal thickness (VSTh), aortic diameter (AoD), area of the chordal lumen of the left ventricle (CTA), left ventricular diameter (LVD) and left atrial diameter (LAD) were determined at ventricular end-dias...
Baldwin CM, Morgan RE, Crawford AL, Villarino NF, Rubio-Martínez LM.(1) To describe the computed tomography (CT) and gross anatomy of the equine extensor carpi radialis sheath (ECRS) and common digital extensor sheath (CDETS); (2) to describe a single-portal endoscopic examination of the ECRS and CDETS. Methods: Ex vivo experimental. Methods: Thirty clinically normal cadaver thoracic equine limbs severed at the humeral diaphysis. Methods: Ten limbs underwent plain and intrathecal contrast CT examinations and gross dissection of the ECRS and CDETS. Single-portal endoscopic examination of ECRS and CDETS was attempted in 4 limbs and endoscopic examination was per...
Tnibar MA, Auer JA, Bakkali S.This study was intended to document normal ultrasonographic appearance of the equine shoulder and anatomic landmarks useful in clinical imaging. Both forelimbs of five equine cadavers and both forelimbs of six live adult horses were used. To facilitate understanding of the images, a zoning system assigned to the biceps brachii and to the infraspinatus tendon was developed. Ultrasonography was performed with a real-time B-mode semiportable sector scanner using 7.5- and 5-MHz transducers. On one cadaver limb, magnetic resonance imaging (MRI) was performed using a system at 1.5 Tesla, T1-weighted...
Raisis AL, Mosing M, Hosgood GL, Secombe CJ, Adler A, Waldmann AD.Electrical impedance tomography (EIT) provides clinically useful lung images; however, it would be an advantage to extract additional cardiovascular information from the data. The aim of this study was to evaluate if cardiac-related changes measured by EIT can be used to measure pulse rate (PR) under physiological as well as high and low blood pressure states in anaesthetised horses. Electrical impedance tomography data and PR from seven horses anaesthetised in dorsal recumbency were recorded over 1 min during mechanical ventilation and 1 min of apnoea. Data were collected at four measurement ...
Pozor MA, McDonnell SM.For the purpose of establishing clinical reference values, this paper reports results of ultrasonographic examination and measurement of accessory sex glands, ampullae, and the pelvic urethra of 102 mature, healthy breeding stallions (2-29 years of age) of various size types (7 Miniature Horses, 27 small ponies, 53 light horses and 15 heavy horses). Examinations were done per rectum in mostly unsedated stallions using an Aloka 210 scanner with a 7.5 MHz linear veterinary transrectal transducer (Corometrics Medical Systems, Inc., North Wallingford, CT, USA). Most measures of accessory sex gland...
Sellke L, Patan-Zugaj B, Ludewig E, Cimrman R, Witter K.Different measuring techniques have been used to objectify the classification of hoof shape. The MicroScribe is a novel tool that might prove useful for measuring hooves without prior reconstruction or compensation of projection artefacts. The aim of this study was to compare biometric data of the equine hoof collected by the MicroScribe tool and measurements collected directly from hooves, scaled photographs and radiographs, from photogrammetry models and computed tomography datasets. The suitability of MicroScribe generated data to differentiate individual hoof conformations was tested. A to...
Carstens A, Kirberger RM, Dahlberg LE, Prozesky L, Fletcher L, Lammentausta E.The purpose of this study was to determine whether delayed gadolinium-enhanced magnetic resonance imaging of cartilage (dGEMRIC) and T2 mapping are accurate techniques for measuring cartilage thickness in the metacarpus3/metatarsus3 (Mc3/Mt3) of Thoroughbred racehorses. Twenty-four Mc3/Mt3 cadaver specimens were acquired from six healthy racehorses. Cartilage thickness was measured from postintra-articular Gd-DTPA(2-) images acquired using short tau inversion recovery (STIR), and proton density weighted (PDw) sequences, and compared with cartilage thickness measured from corresponding histolog...
Byrne CA, Marshall JF, Voute LC.Investigation of image quality in clinical equine magnetic resonance (MR) imaging may optimise diagnostic value. Objective: To assess the influence of field strength and anaesthesia on image quality in MR imaging of the equine foot in a clinical context. Methods: Analytical clinical study. Methods: Fifteen equine foot studies (five studies per system) were randomly selected from the clinical databases of three MR imaging systems: low-field standing (LF St), low-field anaesthetised (LF GA) and high-field anaesthetised (HF GA). Ten experienced observers graded image quality for entire studies an...
Mirmojarabian SA, Kajabi AW, Ketola JHJ, Nykänen O, Liimatainen T, Nieminen MT, Nissi MJ, Casula V.Machine learning models trained with multiparametric quantitative MRIs (qMRIs) have the potential to provide valuable information about the structural composition of articular cartilage. To study the performance and feasibility of machine learning models combined with qMRIs for noninvasive assessment of collagen fiber orientation and proteoglycan content. Retrospective, animal model. An open-source single slice MRI dataset obtained from 20 samples of 10 Shetland ponies (seven with surgically induced cartilage lesions followed by treatment and three healthy controls) yielded to 1600 data points...