Topic:Measurement Techniques
Measurement techniques in horses encompass various methods and tools used to assess and quantify different physiological, anatomical, and biomechanical parameters in equine studies. These techniques are employed to gather data on aspects such as body condition, gait analysis, heart rate, and respiratory function, among others. Common measurement techniques include the use of thermography for detecting temperature variations, ultrasonography for imaging soft tissues, and force plates for analyzing gait dynamics. These methods provide valuable information for understanding equine health, performance, and biomechanics. This page compiles peer-reviewed research studies and scholarly articles that explore the application, accuracy, and reliability of measurement techniques in equine research.
Factors Affecting Weigh Tape Reading in the Measurement of Equine Body Weight. Accurate measurement of equine body weight is important for evaluating medication dosages and feed quantities. Different methods exist for measuring body weight, including weigh tapes (WT), though accuracy varies. Measurements could be affected by external variables, such as time of day, human error, or uneven surfaces, and also horse-based variables, such as height and body condition score (BCS). The aim of this study was to investigate how different horse-based variables affect WT reading. A retrospective analysis was performed using anonymised data from feed company nutrition consultations ...
Warm Season Turfgrass Equine Sports Surfaces: An Experimental Comparison of the Independence of Simple Measurements Used for Surface Characterization. Turfgrass in equine sports has clear advantages over other types of reinforcement but adds complexity to the management. This study investigates factors that influence the turfgrass' surface performance and how the use of a drainage package and a geotextile reinforcement affect quantitative measurements of turfgrass. The measurements are made using affordable, lightweight testing tools that are readily available or easily constructed. Eight boxes with turfgrass over a mix of the arena with peat at a consistent depth were tested for volumetric moisture content (VMC %) with time-domain reflectom...
Comparison of four tonometers in the measurement of intraocular pressure in healthy horses. Measurement of the intraocular pressure (IOP) is a useful diagnostic tool in equine ophthalmology. Handheld tonometers, such as Tonovet and Tonovet Plus (rebound), Tono-Pen AVIA Vet (applanation), and Kowa HA-2 (applanation using the Goldmann methodology) are used to obtain IOP measurements in veterinary medicine. Objective: To compare and evaluate the accuracy of four handheld tonometers in measuring IOP using different methodologies in healthy horses. Methods: In vivo experiment and cross-sectional survey of healthy horses. Methods: Intraocular pressure was measured in 72 eyes of 36 horses. ...
Comparison of Six Different Methods for Measuring the Equine Hoof and Recording of its Three-Dimensional Conformation. Different measuring techniques have been used to objectify the classification of hoof shape. The MicroScribe is a novel tool that might prove useful for measuring hooves without prior reconstruction or compensation of projection artefacts. The aim of this study was to compare biometric data of the equine hoof collected by the MicroScribe tool and measurements collected directly from hooves, scaled photographs and radiographs, from photogrammetry models and computed tomography datasets. The suitability of MicroScribe generated data to differentiate individual hoof conformations was tested. A to...
An Investigation Into Different Measurement Techniques to Assess Equine Proximal Hoof Circumference. Equine hoof conformation is integral to equine performance and soundness. Consequently, it is a major area of interest within the field of equine health. Researchers have measured several hoof shape parameters to study the hoof conformation. Proximal hoof circumference (PHC) is a primary hoof shape parameter, and its assessment may help to recognize the early stages of the development of changes in hoof morphology or poor hoof shape. Previous studies have mainly used a measuring tape to measure PHC. However, some doubts still exist regarding the reliability, repeatability and accuracy of measu...
Measurement accuracy of foot conformation parameters on low-field magnetic resonance images in horses. Foot imbalance and malalignment of the digits are common in horses. Angle and distance measurements performed on bones, joints and hoof wall on radiographs provide essential guidance for precise corrective trimming and shoeing. This study aimed to investigate, if selected standing low-field magnetic resonance (MR) images can be used to accurately measure dorsopalmar and lateromedial foot conformation parameters in comparison to the radiographic gold standard. Images of 100 horses referred for standing low-field MR examination were selected. Foot conformation angles and distances were measured ...
Extracranial guiding structures for navigation to specific topographical sectors of the equine neopallium: an anatomical investigation performing three-dimensional distance measurements in adult warm-blooded horses. This basically anatomical study focuses on two items; firstly, the establishment of a system for the cartographic subdivision of the neopallium; secondly, the topographical correlation of extracranial landmarks and intracranial sites on the neopallium. Methods: The surface of the neopallium was subdivided into 15 sectors with reference to a newly introduced pattern of Primary Sulci. The topographical link between extracranial landmarks and certain intracranial sites (i.e. neopallium sectors) was elaborated by using a simple stereotactic device and a computer-assisted measurement device. Measur...
Radiographic assessment of carpal conformation in the horse: Technique development and validation of the consistency of measurements. Carpal conformation is often considered as a contributory factor to performance and lameness in the horse; however, few attempts have been made to objectively measure radiographic variations of carpal conformation in horses due to insufficient measurable carpal parameters. This pilot study used carpal radiographic images acquired from 10 cadaveric equine forelimbs transected at the antebrachial midshaft from 7 adult horses (7.2 ± 2.6 years), positioned at 'zero lateromedial' (ZLM) and 'zero dorsopalmar' (ZDP) views, to investigate the anatomy of the equine carpus and develop parameters tha...
Evaluation of the Accuracy of Horse Body Weight Estimation Methods. Methods of estimating horse body weight using mathematical formulae have better accuracy than methods of reading body weight from measuring tape. The aim of the study was to evaluate established formulae for estimating horse body weight from data gathered using measurement tape. The research was conducted in a group of 299 adult horses and ponies of selected breeds: ponies ( = 58), Polish Noble Half Breed ( = 150), Silesian Breed ( = 23), Wielkopolski Breed ( = 52), and Thoroughbred ( = 16). Body measurements were performed on each horse using a measuring stick and tape. The actual body weight...
[Ultrasonography in neonatal foals: Depiction and measurement of the kidneys]. Aim of the study was to describe the echotexture and dimensions of the kidneys including the renal pelvis in neonatal foals using transabdominal sonography. Methods: In the course of a preliminary examination, sonographic examinations of the kidneys of 10 dead newborn foals were performed in order to determine their localization, measurement parameters, and echotexture. In subsequent necropsies, the kidneys were measured and the obtained values were compared with the sonographic measurements. A high level of agreement between the both measurement values could be demonstrated. In the main exami...
Aortic, common carotid and external iliac artery arterial wall stiffness parameters in horses: Inter-day and inter-observer and intra-observer measurement variability. In human medicine, local and regional arterial wall stiffness (AWS) parameters are routinely used to assess the vascular health. In horses, information regarding reproducibility of ultrasonographically derived AWS parameters is lacking. Objective: To evaluate the inter-day and inter-observer and intra-observer measurement variability of both local and regional AWS parameters in horses. Methods: Experimental study. Methods: In 10 healthy, adult Warmblood horses, B-, M-mode and pulsed-wave Doppler ultrasound images were collected on two different days from aorta, cranial and caudal common caroti...
Estimation of Live Weight by Body Measurements in the Miranda Donkey Breed. The use of the measurement of heart girth (HG), in locations where a scale is not available, with the application of weight estimation formulas or special weight tapes, is well established as a practical and accurate way to estimate the live weight (LW). Although several studies were performed to correlate donkey body measurements and LW, none of these was done in the large frame European donkey breeds. When using smaller frame breeds formulas, the tendency was to underestimate the live weight of larger frame breeds. The sample used in this study consisted of 65 Miranda breed donkeys, with age...
The reliability and forensic soundness of the equine shin circumference measurement in living animals versus post‑mortem examination. Catastrophic injuries in racehorses mostly involve the metacarpal region. Although many studies describe fractures of equine limbs, few examine the relationship between bone morphometrics and musculoskeletal problems in racing horses. And yet, according to the regulation of some Italian traditional races, the shin circumference represents a qualifying prerequisite for horses to be admitted to races. This study aims to evaluate the conformity of the shin circumference measurement in living animals and in post‑mortem examinations, in order to evaluate the forensic reliability of these measurem...
An analysis of the effect of thermometer type and make on rectal temperature measurements of cattle, horses and sheep. To compare the variation in rectal temperature measurement by digital, mercury and ethanol thermometers in cattle, horses and sheep. Methods: Seven different makes of thermometer (four digital, two mercury, and one ethanol; (n=27) were tested individually in a calibrated water bath to identify whether there was an effect of thermometer make on recorded temperature. In addition, rectal temperatures of four cattle, four sheep and four horses were recorded using the same thermometers, by seven persons, with each person being assigned to one thermometer make. Results: In the water bath test, mean ...
Comparison of equine articular cartilage thickness in various joints. Thicknesses of fresh equine articular cartilage surfaces from the fetlock, carpal and stifle joints were measured employing a needle probe test. Methods: Eighty-seven samples used in measurement were cultivated from fetlock, carpal and stifle joints of 12 deceased within 4 h of death. After approximately three minutes of exposure to air during dissection, all cartilage samples were preserved in a saline solution to keep the articular cartilage hydrated for testing. The thickness was measured on five different spots on the same sample. The thicknesses of the fetlock, carpus and stifle were co...
Accuracy of MRI technique in measuring tendon cross-sectional area. Magnetic resonance imaging (MRI) has commonly been applied to determine tendon cross-sectional area (CSA) and length either to measure structural changes or to normalize mechanical measurements to stress and strain. The ability to reproduce CSA measurements on MRI images has been reported, but the accuracy in relation to actual tendon dimensions has never been investigated. The purpose of this study was to compare tendon CSA measured by MRI with that measured in vitro with the mould casting technique. The knee of a horse was MRI-scanned with 1.5 and 3 tesla, and two examiners measured the pate...
Equine hoof slip distance during trot at training speed: comparison between kinematic and accelerometric measurement techniques. Longitudinal sliding of horse's hooves at the beginning of stance can affect both performance and orthopaedic health. The objective of this study was to compare two measurement methods for quantifying hoof slip distances at training trot. The right front hoof of four French Trotters was equipped with an accelerometer (10 kHz) and kinematic markers. A firm wet sand track was equipped with a 50 m calibration corridor. A high-frequency camera (600 Hz) was mounted in a vehicle following each horse trotting at about 7 m/s. One of the horses was also trotted on raw dirt and harrowed dirt tracks. Lon...
Effects of infrared camera angle and distance on measurement and reproducibility of thermographically determined temperatures of the distolateral aspects of the forelimbs in horses. To assess effects of camera angle and distance on measurement and reproducibility of thermographically determined temperatures of the distolateral aspect of the forelimbs in horses. Methods: Evaluation study. Methods: 10 adult horses. Methods: Thermographic images of both forelimbs were obtained at 3 times during the day (replicates 1, 2, and 3); maximum surface temperature over 1 region (distolateral aspect of the third metacarpal bone and metacarpophalangeal joint) was measured. Standard images were obtained every 5 minutes for 1 hour with the camera positioned at an angle of 90° and a dist...
The proximal aspect of the suspensory ligament in the horse: How precise are ultrasonographic measurements? To evaluate intra- and interobserver variability in ultrasonographic measurements of the proximal aspect of the suspensory ligament (PSL) in the horse. Objective: A minimum difference of ≥20% is required to differentiate reliably between physiological and pathological alterations related to dimensions. Methods: Two operators examined the PSL in all 4 limbs of 14 horses twice using different techniques and different probes with and without standoff pads. Measurements were taken from the longitudinal and transverse images. Inter- and intraoperator variability was evaluated using agreement indi...
Contribution of dynamic calibration to the measurement accuracy of a pressure plate system throughout the stance phase in sound horses. The aim of this study was to evaluate the accuracy of the vertical force curve of a pressure plate (PP) using dynamic calibration with a force plate (FP) in six sound Warmblood horses. The animals were walked and trotted over a combined PP-FP system sampling at 250 Hz. Five valid measurements of each forelimb were collected. The recalibration factor (RF), the ratio between the calibrated and raw PP data, was evaluated in each timeframe throughout the stance phase. Following dynamic calibration, the vertical force curve of the PP demonstrated a characteristic biphasic pattern at the walk and ty...
Reference ranges and reliability of transabdominal ultrasonographic renal dimensions in thoroughbred horses. The aims of this study were to establish a normal reference range (mean ± 2 SD) and assess reliability of renal dimensions obtained using transabdominal ultrasonography in Thoroughbred horses (n = 7). A minimum of three ultrasonographic cineloops were obtained from each intercostal space and the left paralumbar fossa by two observers daily for three consecutive days. Renal length, width, and thickness and cortex, medulla, and pelvic dimensions were obtained. Measurements were undertaken by both observers, who were unaware of prior measurements, to assess reproducibility and measured on three ...
Effect of equestrian therapy and onotherapy in physical and psycho-social performances of adults with intellectual disability: a preliminary study of evaluation tools based on the ICF classification. To assess the effects of equestrian rehabilitation (ER) and onotherapy (Ono) on physical and psycho-social performances of subjects affected by intellectual disability (ID), and to develop a measurement tool based on the International Classification of Functioning Disability and Health-Children and Youth (ICF-CY). Methods: A tool based on the ICF-CY classification was designed to evaluate subjects undergoing equine rehabilitation within a bio-psychosocial approach. A simplified version of this evaluation form was developed for the equestrian instructors. The agreement between the two tools was...
Repeatability, reproducibility, and effect of head position on central venous pressure measurement in standing adult horses. Central venous pressure (CVP) is a used as an estimation of intravascular volume status in various species. Techniques for measuring CVP in horses have been described, but the repeatability of these readings at a single time point or over time has not been established. Objective: That CVP measurements in healthy adult horses would be repeatable at each time point, that these readings would be reproducible over time, and that alteration in head position relative to the heart would alter CVP. Methods: Ten healthy adult research horses. Methods: In an experimental study, horses were instrumented ...
A linear laser scanner to measure cross-sectional shape and area of biological specimens during mechanical testing. Measure of the cross-sectional area (CSA) of biological specimens is a primary concern for many biomechanical tests. Different procedures are presented in literature but besides the fact that noncontact techniques are required during mechanical testing, most of these procedures lack accuracy or speed. Moreover, they often require a precise positioning of the specimen, which is not always feasible, and do not enable the measure of the same section during tension. The objective of this study was to design a noncontact, fast, and accurate device capable of acquiring CSA of specimens mounted on a ...
Observer agreement study of cervical-vertebral ratios in horses. Different examiners or the same examiner were observed at different times producing slightly different results when obtaining cervical-vertebral ratios. If the difference is substantial, then measurement variability would have an important impact of radiographic interpretation. Objective: To quantify agreement and repeatability of these measurements. Methods: An observer agreement study was performed using 75 horses. Measurements were made at C3-4 and C6-7 by a board-certified radiologist and an imaging resident. Intra- and interobserver agreement was quantified using Bland-Altman plots. Repea...
Height measurement in horses and ponies: optimising standard protocols. Standard and modified measuring sticks were used to record height at the withers and a 'non-contact' laser was used to measure withers and loin heights. Sixty horses and ponies, ranging in height (115 to 155 cm) and body condition score (BCS) (moderate to obese) were measured by each method at 10-minute intervals for 40 minutes. Measurement series were repeated over three successive days. Unique regression models were constructed for method-specific data. Coefficients of variation were similar for stick and laser methods (0.002 to 0.004 per cent). Models were not influenced by day of measureme...
Radiographic quantification of tracheal dimensions of the normal Thoroughbred horse. Radiographic measurement of tracheal dimensions in the horse may be useful in evaluating upper and lower respiratory tract conditions due to the gradient of pressure changes between these areas. Lateral radiographs of the trachea of 15 normal sedated Thoroughbred horses were made at inspiration and expiration and magnification-corrected mean airway heights measured were, respectively: larynx: 5.89 and 5.86 cm; trachea at the third cervical vertebra (C3): 4.17 and 4.04cm; at the fifth cervical vertebra (C5): 3.62 and 3.59 cm; at the first thoracic vertebra (T1): 3.4 and 3.23cm; and carina: 3.85...
Use of a stand-alone pressure plate for the objective evaluation of forelimb symmetry in sound ponies at walk and trot. Subtle lameness in horses may be difficult to diagnose and methods to evaluate lameness objectively are useful when equine clinicians fail to reach a consensus. The aim of this study was to determine whether equine pressure plate measurements are repeatable when used to calculate forelimb loading (peak vertical pressure [PVP], peak vertical force [PVF], vertical impulse [VI]) and symmetry ratios, and to establish if these data are similar to the 'gold standard' force plate values. Since plate dimensions are relatively small, ponies were used to enable recordings to be taken from both forelimbs...
Measuring the height at the withers of ponies at a competition and at home using a laser device. Measuring the height of ponies at the withers is currently a prerequisite at Fédération Equestre Internationale (FEI) competitions. A pony measured at a competition site must not measure more than 151 cm with, or 150 cm without horse shoes. When a pony exceeds the regulated height, it is excluded from participation in the competition. Moreover, the sale value of a pony can decrease dramatically if by height measurement it is designated as a 'horse'. The aim of this study was firstly to determine whether measuring ponies at the withers with a laser device is repeatable; secondly, to evaluate ...