Topic:Medical Device
Medical devices in equine care encompass a range of tools and technologies designed to diagnose, monitor, or treat medical conditions in horses. These devices can include imaging equipment, such as ultrasound and radiography machines, which help in visualizing internal structures; wearable sensors for tracking vital signs and activity levels; and therapeutic devices, such as laser therapy equipment, used in rehabilitation. Medical devices are integral to equine veterinary practice, aiding in the assessment of health status, guiding treatment decisions, and monitoring recovery. This page compiles peer-reviewed research studies and scholarly articles that explore the development, application, and impact of medical devices in equine medicine.
Comparison of three methods of tonometry in horses presented for ophthalmic disease. To compare the measurement of intraocular pressure in horses with clinical ocular disease using three tonometry devices. Conclusions: All three tonometers showed strong agreement, however, the TonoVet and the TonoVet Plus carried the strongest agreement with the TonoVet Plus having slightly higher measurements overall compared with the TonoVet. Due to small variations between devices, it is recommended that the same device be used for serial measurements of intraocular pressure. However, all three devices are appropriate to use in horses presented for ophthalmic evaluation.
Use of a new device for inversion of the necrotic ileal stump in the caecum in four horses. In jejunocaecal anastomosis leaving a necrotic ileal stump has been implicated in complications and poor outcomes. Elective inversion of the necrotic stump using a nasogastric tube has been previously described, although this procedure can be cumbersome and can cause caecocolic orifice occlusion. Objective: To describe the use of a new device for elective inversion of necrotic ileal stumps. Methods: Case report. Methods: Details of the four horses that underwent intestinal resection and anastomosis with elective inversion of the ileal stump were retrieved from their medical records. For each c...
Comparison of four tonometers in the measurement of intraocular pressure in healthy horses. Measurement of the intraocular pressure (IOP) is a useful diagnostic tool in equine ophthalmology. Handheld tonometers, such as Tonovet and Tonovet Plus (rebound), Tono-Pen AVIA Vet (applanation), and Kowa HA-2 (applanation using the Goldmann methodology) are used to obtain IOP measurements in veterinary medicine. Objective: To compare and evaluate the accuracy of four handheld tonometers in measuring IOP using different methodologies in healthy horses. Methods: In vivo experiment and cross-sectional survey of healthy horses. Methods: Intraocular pressure was measured in 72 eyes of 36 horses. ...
Novel Technique for Transducer Handling in Sterile Ultrasound Guided Procedures. The objective of this paper is to describe a novel technique for handling an ultrasound transducer while performing sterile ultrasound guided procedures. This novel technique involves placement of the transducer inside the sterile glove on the hand of the operator. This technique allows the operator access to use of both hands without having to pass the transducer to an assistant.
In Vivo Versus In Vitro Degradation of a 3D Printed Resorbable Device for Ligation of Vascular Tissue in Horses. A resorbable 3D printed polydioxanone (PDO) device is manufactured to facilitate ligation of vascular tissue during surgery. The device must provide sufficient mechanical performance throughout the healing period. Therefore, degradation and mechanical performance of the device are investigated as a function of in vivo and in vitro aging. During aging the PDO device released cyclic and linear water-soluble products. In vivo aging resulted in higher relative number of linear oligomers in comparison to in vitro aging. A major loss of mechanical performance is observed after only 10 days in vivo a...
An Overview of the Use of Equine Collagen as Emerging Material for Biomedical Applications. Type I collagen has always aroused great interest in the field of life-science and bioengineering, thanks to its favorable structural properties and bioactivity. For this reason, in the last five decades it has been widely studied and employed as biomaterial for the manufacture of implantable medical devices. Commonly used sources of collagen are represented by bovine and swine but their applications are limited because of the zoonosis transmission risks, the immune response and the religious constrains. Thus, type-I collagen isolated from horse tendon has recently gained increasing interest a...
Comparison of two rebound tonometers in healthy horses. To obtain a reference range for evaluation of intraocular pressure (IOP) in horses using Tonovet Plus , to compare the IOP readings obtained with Tonovet and Tonovet Plus , and to evaluate the repeatability of readings. Unassigned: Intraocular pressure of 30 client-owned horses (60 eyes) with no signs of illness or ocular disease was evaluated using Tonovet and Tonovet Plus rebound tonometers. Horses' mean age was 10.7 (range 6-17) years. Triplicate measurements were performed without using sedatives or local anesthetics, with minimal restraint. Results: Calculated reference intervals (the CLS...
Wound Retractor Laparoscopic Port System for Standing Laparoscopic Cryptorchidectomy in the Horse: A Case Report. Cryptorchidectomy is the most commonly performed laparoscopic procedure in horses. However, its use for the extraction of an abdominal testis has disadvantages such as loss of a resected testis from grasp and fragmentation of the specimen because of the excessive tension required for extraction through a thick body wall. The ring wound retractor laparoscopic port system was recently used in human and small animal surgery to perform laparoscopic-assisted procedures and retrieve large specimens from the abdomen. In the present case, the wound retractor was placed as the ventral port in the right...
On-site testing of sutured organs: An experimental set up to cyclically tighten sutures. A number of surgical practices are aimed to compensate for tissue relaxation or weakened/atrophied muscles by means of suture prostheses/thread lifts. The success rate of these procedures is often very good in the short term, while it is quite variable among subjects and techniques in the middle-long term. Middle-long term failures are mostly related to suture distraction, loosening or wear, coming from repeated loading cycles. In this work, an experimental device to perform ex vivo tests on prosthetic sutures has been set up. An equine laryngoplasty has been used as a benchmark, being represe...
Comparison of a continuous indwelling glucometer with a point-of-care device in healthy adult horses. Blood glucose is tightly regulated in horses; however, since hypoglycaemia and hyperglycaemia are associated with poor prognosis, close monitoring is warranted. This study aimed at evaluating a continuous indwelling glucometer (CIG) by comparing performance with a point-of-care glucometer (POC). Ten horses were equipped with CIG and an intravenous catheter. Interstitial glucose concentrations were determined by CIG every 5 min at rest, during insulin-induced hypoglycaemia and dextrose-induced hyperglycaemia, and compared with blood glucose determined by POC. Glucose concentrations were compa...
Measurement of peripheral muscle oxygen saturation in conscious healthy horses using a near-infrared spectroscopy device. Maintaining adequate muscle tissue oxygenation is of paramount importance during equine general anesthesia. The objectives of this study were to assess the feasibility, reliability and repeatability of near-infrared spectroscopy (NIRS) muscle oximetry using the Inspectra m650 in conscious healthy adult horses. Methods: Prospective, observational study. Methods: A group of 30 healthy client-owned adult horses admitted to the equine hospital between July 2017 and July 2018. Methods: The probe of an Inspectra m650 NIRS tissue oximeter was placed on the hairless surface of five muscle sites (omotr...
Feasibility of a disposable canister-free negative-pressure wound therapy (NPWT) device for treating open wounds in horses. Wounds are among the most common medical conditions affecting horses and have a major economic impact on the horse industry. Wound healing in horses is distinct to that documented in other species, and often results in delayed healing and extensive scarring, with compromised functional and aesthetic outcomes. To date, there is no conventional method objectively proven to accelerate healing or to successfully prevent complications associated with second intention healing. Several effects of Negative Pressure Wound Therapy (NPWT) may be particularly useful to the management of wounds in horses. ...
Evaluation of a prototype dynamic laryngoplasty system in vitro with an equine vacuum airflow system. To evaluate a prototype dynamic laryngoplasty system (DLPS) in a static airflow model. Methods: Experimental. Methods: Ten equine larynges. Methods: The right arytenoid was fixed in abduction in all specimens. A left-sided laryngoplasty was performed with No. 2 Fiberwire and a FASTakII anchor. Each larynx was tested in a static airflow model. The system was adjusted to a flow rate of 55 L/s and prelaryngeal pressure of 12 mm Hg prior to testing in maximal arytenoid abduction. In phase 1, the left suture was loosened, shortened, and tested in 3-mm steps from 0 to 30 mm. In phase 2, the su...
Very long-term outcome of coronary covered stents: a report from the SCAAR registry. Covered stents are mostly used for coronary perforations with a high risk of early adverse events; however, their long-term outcome is unknown. The aim of this study was to elucidate the short- and long-term outcome of patients treated with covered stents compared to all other stented patients. Results: The Swedish national registries from 2005-2017 disclosed 265 patients who had received 366 covered stents. Their outcomes were compared to all other stented patients (197,948) who had received 320,784 stents. Compared to regular stents, covered stents showed significant differences (p<0.001)...
In vitro evaluation of the effect of a prototype dynamic laryngoplasty system on arytenoid abduction. To determine the effect of a prototype dynamic laryngoplasty system (DLPS) on arytenoid abduction. Methods: In vitro experimental. Methods: Ten equine larynges. Methods: Dissected larynges were mounted, and the right arytenoid was maximally abducted for testing. A left-sided laryngoplasty (LP) was performed by using a strand of No. 2 FiberWire and a FASTakII anchor. Phase 1 involved tightening the suture, without the DLPS device in place, in 1-mm increments and acquiring a digital image of the rima glottidis at each increment. Phase 2 involved tying the suture with the DLPS in place at a left ...
Equine pericardium-covered stenting in post-traumatic pseudoaneurysm of cavernous internal carotid artery. We report a case of traumatic intracranial carotid artery pseudoaneurysm treated with an equine pericardium-covered stent. The patient was admitted to the Emergency Department after sustaining severe polytrauma in a motor vehicle accident. A cavernous carotid pseudoaneurysm was detected after an episode of massive epistaxis that required emergent nasal packing. Treatment with parent vessel sacrifice was ruled out after an unfavourable balloon test occlusion. We opted for an equine pericardium-covered stent as a means to immediately seal the wall defect in the setting of massive bleeding second...
Technical note: Evaluation of a wireless pulse oximeter for measuring arterial oxygen saturation and pulse rate in newborn Holstein Friesian calves. Pulse oximetry is a well-established technique in human and veterinary medicine. In farm animals, it could also be a useful tool for the detection of critical conditions relating to oxygen supply and the cardiovascular system. Among other uses, an innovative application could be the monitoring of fetuses during birth. This could help in the early identification of critical situations and support farmers and veterinarians in their decision to start obstetric or life-support interventions. Until now, however, its use in ruminant medicine was still limited to experimental applications. The object...
Vessel sealer and divider instrument temperature during laparoscopic ovariectomy in horses. To determine the temperature of a vessel sealer and divider device during unilateral paralumbar laparoscopic ovariectomy in standing, sedated mares. Methods: Prospective study. Methods: Fifteen healthy research mares. Methods: Healthy mares with normal ovarian palpation and ultrasonographic appearance were enrolled. Horses were restrained in standing stocks and sedated. A right or left paralumbar ovariectomy was performed with a laparoscopic portal and 2 instrument portals. Ovaries were excised with traumatic forceps and a blunt tip vessel sealer and divider. Temperatures of the vessel sealer ...
Development and clinical evaluation of a new sensor design for buccal pulse oximetry in horses. The use of pulse oximetry in horses is limited due to inadequate readings with conventional transmission sensor probes. Objective: The objectives of this study were to 1) develop an improved sensor design for horses to be used at an appropriate anatomical site, and 2) evaluate this design in an experimental study. Methods: In vivo experiment. Methods: A new sensor design for reflectance pulse oximetry at the buccal mucosa was developed. A conventional Nonin 2000SL sensor for transmission pulse oximetry was included into this design. Three different prototypes (N1, N2a, N2b) were constructed an...
The benefits and limitations of animal models for translational research in cartilage repair. Much research is currently ongoing into new therapies for cartilage defect repair with new biomaterials frequently appearing which purport to have significant regenerative capacity. These biomaterials may be classified as medical devices, and as such must undergo rigorous testing before they are implanted in humans. A large part of this testing involves in vitro trials and biomechanical testing. However, in order to bridge the gap between the lab and the clinic, in vivo preclinical trials are required, and usually demanded by regulatory approval bodies. This review examines the in vivo models ...
Design of an endovascular morcellator for the surgical treatment of equine Cushing’s disease. A new paradigm of surgical treatment of equine Cushing's disease has been developed using the vascular system combined with a flexible morcellation instrument to reach the pituitary gland. Objective: The goal was twofold: (1) to design, prototype, and test an instrument that can reach the pituitary gland using the vascular system unique to equids and (2) to test the feasibility of the endovascular approach. Methods: The morcellator consists of a radial rotating cutting blade for tissue resection, a flexible shaft incorporating a cable drive for flexible actuation, and central morcellated tissu...
[Interbody fusion procedures. Development from a historical perspective]. The development of interbody fusion now stretches over many decades and is still not complete. Conclusions: Due to the lack of appropriate implants, the initial fusions were performed via decortication of the dorsal and lateral structures of the spine, followed by placement of an autograft. Despite acceptable fusion results, better primary stability and higher fusion rates were desired. In addition, it became known that the primary load-bearing of the spine is located ventrally in the area of the corpus of the vertebrae. These considerations led to the development of the PLIF technique that wa...
Biomechanical evaluation of a novel subcuticular skin stapling device for use in equine abdominal surgeries. To compare the in vitro biomechanical properties of a novel subcuticular stapling device to current methods of abdominal skin closure for equine abdominal surgery. Methods: In vitro randomized, matched design. Methods: Equine ventral median abdominal skin specimens (n = 24 horses). Methods: Subcuticular absorbable staples (SAS), metallic staples (MS), polyglyconate suture (PG), and nylon monofilament (NYL) were applied to longitudinally transected portions of equine ventral midline skin. Loads that resulted in an initial failure point and the ultimate failure load and mechanism were record...
Systematic evaluation of evidence on veterinary viscoelastic testing part 1: System comparability. To systematically examine the evidence on system comparability between the thromboelastography and the rotational thromboelastometry viscoelastic point-of-care instruments and to identify knowledge gaps. Methods: Standardized, systematic evaluation of the literature, categorization of relevant articles according to level of evidence and quality, and development of consensus on conclusions for application of the concepts to clinical practice. Methods: Academic and referral veterinary medical centers. Results: Medline via PubMed, CAB abstracts, and Google Scholar were searched. A total of 8 rele...
In vitro and in vivo evaluation of a new large animal spirometry device using mainstream CO2 flow sensors. A spirometry device equipped with mainstream CO2 flow sensor is not available for large animal anaesthesia. Objective: To measure the resistance of a new large animal spirometry device and assess its agreement with reference methods for volume measurements. Methods: In vitro experiment and crossover study using anaesthetised horses. Methods: A flow partitioning device (FPD) equipped with 4 human CO2 flow sensors was tested. Pressure differences were measured across the whole FPD and across each sensor separately using air flows (range: 90-720 l/min). One sensor was connected to a spirometry ...
Near-fatal misuse of medical tape around an endotracheal tube connector during inhalation anesthesia in a horse. A 7-year-old gelded Irish sports horse weighing 650 kg was anesthetized on 2 consecutive days for lavage of a septic right radio-carpal joint. On both occasions the endotracheal tube connector, which had been bound in medical tape to produce an airtight seal, functioned as a unidirectional valve during mechanical ventilation, retarding expiration, imposing positive end expiratory pressure (PEEP), and probably continuous positive airway pressure (CPAP). The equipment dysfunction was not identified on either occasion despite close inspection prompted by progressive increases in airway pressure a...
Advances in equine ultrasonography. The many advancements in ultrasound technology, including spatial compounding, harmonic imaging, multidimensional and extended field-of-view images, and improvements in transducer capabilities, are used to enhance the ultrasonographic examination of the equine patient. The improvements in software and hardware capabilities help overcome artifacts, improve image quality, and allow better documentation of the examination for follow-up studies. In addition, the ability of smaller, more portable machines to produce better images is ideal for the ambulatory practice setting.
Equine laparoscopy: equipment and basic principles. Laparoscopic techniques for veterinary surgery are growing in popularity for the same reason the use of minimally invasive procedures has increased tremendously in human surgery. Compared with open surgery, the benefits of laparoscopic surgery include smaller incisions, reduced postoperative morbidity and pain, shorter hospitalization, a more rapid return to normal activities, and, in some instances, superior access. Laparoscopic surgery is different from open surgery in equipment/instrumentation and psychomotor skills. This first article in a series on equine laparoscopic surgery introduces t...
Laparoscopic cryptorchidectomy and ovariectomy in standing horses using the EnSeal® tissue-sealing device. In the present series of cases, 8 laparoscopic cryptorchidectomies and 4 laparoscopic ovariectomies were carried out in sedated standing horses. Sedation involved a lesser anaesthesiological risk than does general anaesthesia. As compared to laparotomic exposure, the minimally invasive laparoscopic intervention provided better visualisation, shorter operative time and faster recovery. The blood vessels supplying the testes and ovaries and the suspensory ligaments of the organs were sealed and cut with EnSeal®, an adaptive bipolar electrosurgical blood vessel- and tissue-sealing device. The cl...