Medical devices in equine care encompass a range of tools and technologies designed to diagnose, monitor, or treat medical conditions in horses. These devices can include imaging equipment, such as ultrasound and radiography machines, which help in visualizing internal structures; wearable sensors for tracking vital signs and activity levels; and therapeutic devices, such as laser therapy equipment, used in rehabilitation. Medical devices are integral to equine veterinary practice, aiding in the assessment of health status, guiding treatment decisions, and monitoring recovery. This page compiles peer-reviewed research studies and scholarly articles that explore the development, application, and impact of medical devices in equine medicine.
Latham E, Scherrer NM, Stefanovski D.To compare the measurement of intraocular pressure in horses with clinical ocular disease using three tonometry devices. Conclusions: All three tonometers showed strong agreement, however, the TonoVet and the TonoVet Plus carried the strongest agreement with the TonoVet Plus having slightly higher measurements overall compared with the TonoVet. Due to small variations between devices, it is recommended that the same device be used for serial measurements of intraocular pressure. However, all three devices are appropriate to use in horses presented for ophthalmic evaluation.
Gandini M, Giusto G.In jejunocaecal anastomosis leaving a necrotic ileal stump has been implicated in complications and poor outcomes. Elective inversion of the necrotic stump using a nasogastric tube has been previously described, although this procedure can be cumbersome and can cause caecocolic orifice occlusion. Objective: To describe the use of a new device for elective inversion of necrotic ileal stumps. Methods: Case report. Methods: Details of the four horses that underwent intestinal resection and anastomosis with elective inversion of the ileal stump were retrieved from their medical records. For each c...
Angeluci GC, Ricci CL, Passareli JVGC, Estanho GJG, Oliveira AS, Santos SGA, Giuffrida R, Rodrigues M, Andrade SF.Measurement of the intraocular pressure (IOP) is a useful diagnostic tool in equine ophthalmology. Handheld tonometers, such as Tonovet and Tonovet Plus (rebound), Tono-Pen AVIA Vet (applanation), and Kowa HA-2 (applanation using the Goldmann methodology) are used to obtain IOP measurements in veterinary medicine. Objective: To compare and evaluate the accuracy of four handheld tonometers in measuring IOP using different methodologies in healthy horses. Methods: In vivo experiment and cross-sectional survey of healthy horses. Methods: Intraocular pressure was measured in 72 eyes of 36 horses. ...
Beasley B, Perlini M.The objective of this paper is to describe a novel technique for handling an ultrasound transducer while performing sterile ultrasound guided procedures. This novel technique involves placement of the transducer inside the sterile glove on the hand of the operator. This technique allows the operator access to use of both hands without having to pass the transducer to an assistant.
Adolfsson KH, Sjöberg I, Höglund OV, Wattle O, Hakkarainen M.A resorbable 3D printed polydioxanone (PDO) device is manufactured to facilitate ligation of vascular tissue during surgery. The device must provide sufficient mechanical performance throughout the healing period. Therefore, degradation and mechanical performance of the device are investigated as a function of in vivo and in vitro aging. During aging the PDO device released cyclic and linear water-soluble products. In vivo aging resulted in higher relative number of linear oligomers in comparison to in vitro aging. A major loss of mechanical performance is observed after only 10 days in vivo a...
Gallo N, Natali ML, Sannino A, Salvatore L.Type I collagen has always aroused great interest in the field of life-science and bioengineering, thanks to its favorable structural properties and bioactivity. For this reason, in the last five decades it has been widely studied and employed as biomaterial for the manufacture of implantable medical devices. Commonly used sources of collagen are represented by bovine and swine but their applications are limited because of the zoonosis transmission risks, the immune response and the religious constrains. Thus, type-I collagen isolated from horse tendon has recently gained increasing interest a...
Mustikka MP, Pietilä EM, Mykkänen AK, Grönthal TSC.To obtain a reference range for evaluation of intraocular pressure (IOP) in horses using Tonovet Plus , to compare the IOP readings obtained with Tonovet and Tonovet Plus , and to evaluate the repeatability of readings. Unassigned: Intraocular pressure of 30 client-owned horses (60 eyes) with no signs of illness or ocular disease was evaluated using Tonovet and Tonovet Plus rebound tonometers. Horses' mean age was 10.7 (range 6-17) years. Triplicate measurements were performed without using sedatives or local anesthetics, with minimal restraint. Results: Calculated reference intervals (the CLS...
Lacitignola L, Imperante A, De Siena R, Acquafredda C, Trisciuzzi R, Stabile M, Confalonieri E, Crovace AM, Staffieri F.Cryptorchidectomy is the most commonly performed laparoscopic procedure in horses. However, its use for the extraction of an abdominal testis has disadvantages such as loss of a resected testis from grasp and fragmentation of the specimen because of the excessive tension required for extraction through a thick body wall. The ring wound retractor laparoscopic port system was recently used in human and small animal surgery to perform laparoscopic-assisted procedures and retrieve large specimens from the abdomen. In the present case, the wound retractor was placed as the ventral port in the right...
Pascoletti G, Pressanto MC, Putame G, Terzini M, Audenino AL, Zanetti EM.A number of surgical practices are aimed to compensate for tissue relaxation or weakened/atrophied muscles by means of suture prostheses/thread lifts. The success rate of these procedures is often very good in the short term, while it is quite variable among subjects and techniques in the middle-long term. Middle-long term failures are mostly related to suture distraction, loosening or wear, coming from repeated loading cycles. In this work, an experimental device to perform ex vivo tests on prosthetic sutures has been set up. An equine laryngoplasty has been used as a benchmark, being represe...
Cunneen A, Wood KA, Mathison K, Herndon AM, Bertin FR.Blood glucose is tightly regulated in horses; however, since hypoglycaemia and hyperglycaemia are associated with poor prognosis, close monitoring is warranted. This study aimed at evaluating a continuous indwelling glucometer (CIG) by comparing performance with a point-of-care glucometer (POC). Ten horses were equipped with CIG and an intravenous catheter. Interstitial glucose concentrations were determined by CIG every 5 min at rest, during insulin-induced hypoglycaemia and dextrose-induced hyperglycaemia, and compared with blood glucose determined by POC. Glucose concentrations were compa...
Gingold BM, Killos MB, Griffith E, Posner L.Maintaining adequate muscle tissue oxygenation is of paramount importance during equine general anesthesia. The objectives of this study were to assess the feasibility, reliability and repeatability of near-infrared spectroscopy (NIRS) muscle oximetry using the Inspectra m650 in conscious healthy adult horses. Methods: Prospective, observational study. Methods: A group of 30 healthy client-owned adult horses admitted to the equine hospital between July 2017 and July 2018. Methods: The probe of an Inspectra m650 NIRS tissue oximeter was placed on the hairless surface of five muscle sites (omotr...
Kamus L, Rameau M, Theoret C.Wounds are among the most common medical conditions affecting horses and have a major economic impact on the horse industry. Wound healing in horses is distinct to that documented in other species, and often results in delayed healing and extensive scarring, with compromised functional and aesthetic outcomes. To date, there is no conventional method objectively proven to accelerate healing or to successfully prevent complications associated with second intention healing. Several effects of Negative Pressure Wound Therapy (NPWT) may be particularly useful to the management of wounds in horses. ...
Ahern BJ, Lukas E, Lam K, Wilke E, Bertin FR, Van Eps A, Franklin S.To evaluate a prototype dynamic laryngoplasty system (DLPS) in a static airflow model. Methods: Experimental. Methods: Ten equine larynges. Methods: The right arytenoid was fixed in abduction in all specimens. A left-sided laryngoplasty was performed with No. 2 Fiberwire and a FASTakII anchor. Each larynx was tested in a static airflow model. The system was adjusted to a flow rate of 55 L/s and prelaryngeal pressure of 12 mm Hg prior to testing in maximal arytenoid abduction. In phase 1, the left suture was loosened, shortened, and tested in 3-mm steps from 0 to 30 mm. In phase 2, the su...
Harnek J, James SK, Lagerqvist B.Covered stents are mostly used for coronary perforations with a high risk of early adverse events; however, their long-term outcome is unknown. The aim of this study was to elucidate the short- and long-term outcome of patients treated with covered stents compared to all other stented patients. Results: The Swedish national registries from 2005-2017 disclosed 265 patients who had received 366 covered stents. Their outcomes were compared to all other stented patients (197,948) who had received 320,784 stents. Compared to regular stents, covered stents showed significant differences (p<0.001)...
Ahern BJ, Lim YW, van Eps A, Franklin S.To determine the effect of a prototype dynamic laryngoplasty system (DLPS) on arytenoid abduction. Methods: In vitro experimental. Methods: Ten equine larynges. Methods: Dissected larynges were mounted, and the right arytenoid was maximally abducted for testing. A left-sided laryngoplasty (LP) was performed by using a strand of No. 2 FiberWire and a FASTakII anchor. Phase 1 involved tightening the suture, without the DLPS device in place, in 1-mm increments and acquiring a digital image of the rima glottidis at each increment. Phase 2 involved tying the suture with the DLPS in place at a left ...
Gonzalez-Cantero JL, Del Valle Diéguez M, Monteserín Matesanz C, Saura Lorente J, Villoria Medina F, Fortea Gil F, Castro Reyes E.We report a case of traumatic intracranial carotid artery pseudoaneurysm treated with an equine pericardium-covered stent. The patient was admitted to the Emergency Department after sustaining severe polytrauma in a motor vehicle accident. A cavernous carotid pseudoaneurysm was detected after an episode of massive epistaxis that required emergent nasal packing. Treatment with parent vessel sacrifice was ruled out after an unfavourable balloon test occlusion. We opted for an equine pericardium-covered stent as a means to immediately seal the wall defect in the setting of massive bleeding second...
Kanz P, Krieger S, Drillich M, Iwersen M.Pulse oximetry is a well-established technique in human and veterinary medicine. In farm animals, it could also be a useful tool for the detection of critical conditions relating to oxygen supply and the cardiovascular system. Among other uses, an innovative application could be the monitoring of fetuses during birth. This could help in the early identification of critical situations and support farmers and veterinarians in their decision to start obstetric or life-support interventions. Until now, however, its use in ruminant medicine was still limited to experimental applications. The object...
Easley JT, McGilvray KC, Hendrickson DA, Bruemmer J, Hackett ES.To determine the temperature of a vessel sealer and divider device during unilateral paralumbar laparoscopic ovariectomy in standing, sedated mares. Methods: Prospective study. Methods: Fifteen healthy research mares. Methods: Healthy mares with normal ovarian palpation and ultrasonographic appearance were enrolled. Horses were restrained in standing stocks and sedated. A right or left paralumbar ovariectomy was performed with a laparoscopic portal and 2 instrument portals. Ovaries were excised with traumatic forceps and a blunt tip vessel sealer and divider. Temperatures of the vessel sealer ...
Reiners JK, Rossdeutscher W, Hopster K, Kästner SBR.The use of pulse oximetry in horses is limited due to inadequate readings with conventional transmission sensor probes. Objective: The objectives of this study were to 1) develop an improved sensor design for horses to be used at an appropriate anatomical site, and 2) evaluate this design in an experimental study. Methods: In vivo experiment. Methods: A new sensor design for reflectance pulse oximetry at the buccal mucosa was developed. A conventional Nonin 2000SL sensor for transmission pulse oximetry was included into this design. Three different prototypes (N1, N2a, N2b) were constructed an...
Moran CJ, Ramesh A, Brama PA, O'Byrne JM, O'Brien FJ, Levingstone TJ.Much research is currently ongoing into new therapies for cartilage defect repair with new biomaterials frequently appearing which purport to have significant regenerative capacity. These biomaterials may be classified as medical devices, and as such must undergo rigorous testing before they are implanted in humans. A large part of this testing involves in vitro trials and biomechanical testing. However, in order to bridge the gap between the lab and the clinic, in vivo preclinical trials are required, and usually demanded by regulatory approval bodies. This review examines the in vivo models ...
Sakes A, Arkenbout EA, Jelínek F, van der Kolk JH, Breedveld P.A new paradigm of surgical treatment of equine Cushing's disease has been developed using the vascular system combined with a flexible morcellation instrument to reach the pituitary gland. Objective: The goal was twofold: (1) to design, prototype, and test an instrument that can reach the pituitary gland using the vascular system unique to equids and (2) to test the feasibility of the endovascular approach. Methods: The morcellator consists of a radial rotating cutting blade for tissue resection, a flexible shaft incorporating a cable drive for flexible actuation, and central morcellated tissu...
Rickert M, Rauschmann M, Fleege C, Behrbalk E, Harms J.The development of interbody fusion now stretches over many decades and is still not complete. Conclusions: Due to the lack of appropriate implants, the initial fusions were performed via decortication of the dorsal and lateral structures of the spine, followed by placement of an autograft. Despite acceptable fusion results, better primary stability and higher fusion rates were desired. In addition, it became known that the primary load-bearing of the spine is located ventrally in the area of the corpus of the vertebrae. These considerations led to the development of the PLIF technique that wa...
Biedrzycki A, Markel MD, Brounts SH.To compare the in vitro biomechanical properties of a novel subcuticular stapling device to current methods of abdominal skin closure for equine abdominal surgery. Methods: In vitro randomized, matched design. Methods: Equine ventral median abdominal skin specimens (n = 24 horses). Methods: Subcuticular absorbable staples (SAS), metallic staples (MS), polyglyconate suture (PG), and nylon monofilament (NYL) were applied to longitudinally transected portions of equine ventral midline skin. Loads that resulted in an initial failure point and the ultimate failure load and mechanism were record...
McMichael M, Goggs R, Smith S, Wagg C, Warman S, Wiinberg B.To systematically examine the evidence on system comparability between the thromboelastography and the rotational thromboelastometry viscoelastic point-of-care instruments and to identify knowledge gaps. Methods: Standardized, systematic evaluation of the literature, categorization of relevant articles according to level of evidence and quality, and development of consensus on conclusions for application of the concepts to clinical practice. Methods: Academic and referral veterinary medical centers. Results: Medline via PubMed, CAB abstracts, and Google Scholar were searched. A total of 8 rele...
Ambrisko TD, Lammer V, Schramel JP, Moens YP.A spirometry device equipped with mainstream CO2 flow sensor is not available for large animal anaesthesia. Objective: To measure the resistance of a new large animal spirometry device and assess its agreement with reference methods for volume measurements. Methods: In vitro experiment and crossover study using anaesthetised horses. Methods: A flow partitioning device (FPD) equipped with 4 human CO2 flow sensors was tested. Pressure differences were measured across the whole FPD and across each sensor separately using air flows (range: 90-720 l/min). One sensor was connected to a spirometry ...
Gregson R, Clutton RE.A 7-year-old gelded Irish sports horse weighing 650 kg was anesthetized on 2 consecutive days for lavage of a septic right radio-carpal joint. On both occasions the endotracheal tube connector, which had been bound in medical tape to produce an airtight seal, functioned as a unidirectional valve during mechanical ventilation, retarding expiration, imposing positive end expiratory pressure (PEEP), and probably continuous positive airway pressure (CPAP). The equipment dysfunction was not identified on either occasion despite close inspection prompted by progressive increases in airway pressure a...
Neelis DA, Roberts GD.The many advancements in ultrasound technology, including spatial compounding, harmonic imaging, multidimensional and extended field-of-view images, and improvements in transducer capabilities, are used to enhance the ultrasonographic examination of the equine patient. The improvements in software and hardware capabilities help overcome artifacts, improve image quality, and allow better documentation of the examination for follow-up studies. In addition, the ability of smaller, more portable machines to produce better images is ideal for the ambulatory practice setting.
Caron JP.Laparoscopic techniques for veterinary surgery are growing in popularity for the same reason the use of minimally invasive procedures has increased tremendously in human surgery. Compared with open surgery, the benefits of laparoscopic surgery include smaller incisions, reduced postoperative morbidity and pain, shorter hospitalization, a more rapid return to normal activities, and, in some instances, superior access. Laparoscopic surgery is different from open surgery in equipment/instrumentation and psychomotor skills. This first article in a series on equine laparoscopic surgery introduces t...
Dunay MP, Németh T, Makra Z, Izing S, Bodó G.In the present series of cases, 8 laparoscopic cryptorchidectomies and 4 laparoscopic ovariectomies were carried out in sedated standing horses. Sedation involved a lesser anaesthesiological risk than does general anaesthesia. As compared to laparotomic exposure, the minimally invasive laparoscopic intervention provided better visualisation, shorter operative time and faster recovery. The blood vessels supplying the testes and ovaries and the suspensory ligaments of the organs were sealed and cut with EnSeal®, an adaptive bipolar electrosurgical blood vessel- and tissue-sealing device. The cl...
Balazs EA, Denlinger JL.Viscosupplementation is a new medical concept that has as its therapeutic goal the restoration of rheological homeostasis in pathological structures such as osteoarthritic joints. When the normal viscoelasticity of a solid tissue compartment or the elastoviscosity of a liquid tissue compartment is decreased under pathological conditions, normal function and regenerative processes are impaired. By introducing viscosupplementary devices, the normal rheological state of such compartments is restored or augmented. These devices stay in the tissue compartment for various periods of time, depending ...
Moran CJ, Ramesh A, Brama PA, O'Byrne JM, O'Brien FJ, Levingstone TJ.Much research is currently ongoing into new therapies for cartilage defect repair with new biomaterials frequently appearing which purport to have significant regenerative capacity. These biomaterials may be classified as medical devices, and as such must undergo rigorous testing before they are implanted in humans. A large part of this testing involves in vitro trials and biomechanical testing. However, in order to bridge the gap between the lab and the clinic, in vivo preclinical trials are required, and usually demanded by regulatory approval bodies. This review examines the in vivo models ...
Gallo N, Natali ML, Sannino A, Salvatore L.Type I collagen has always aroused great interest in the field of life-science and bioengineering, thanks to its favorable structural properties and bioactivity. For this reason, in the last five decades it has been widely studied and employed as biomaterial for the manufacture of implantable medical devices. Commonly used sources of collagen are represented by bovine and swine but their applications are limited because of the zoonosis transmission risks, the immune response and the religious constrains. Thus, type-I collagen isolated from horse tendon has recently gained increasing interest a...
Dursun E, Dursun N, Alican D.In this study our aim was to evaluate the effectiveness of Ankle-Foot Orthoses (AFOs) on gait function in patients with spastic cerebral palsy for whom orthoses were indicated to control dynamic equines deformity. Methods: Twenty-four spastic cerebral palsied patients with dynamic equines deformity were included in the study. Videotape recordings were performed to each patient on the same day with barefoot and AFOs. Temporal distance factors including velocity, cadence, stride length, stride width and Clinical Gait Assessment Score (CGAS) were compared across two conditions. Results: The use o...
Hendrickson DA.This article describes surgical complications associated with laparoscopy, how to avoid them, how to recognize them if they do happen, and how to deal with them in the most expedient method possible. Complications of sedation, anesthesia, positioning, the general surgical approach, and complications associated with specific surgical procedures are examined. The best defense against surgical complications is a thorough training program and an understanding of anatomy that will help the surgeon work in the three-dimensional environment while being limited to two dimensions on the monitor. The au...
McMichael M, Goggs R, Smith S, Wagg C, Warman S, Wiinberg B.To systematically examine the evidence on system comparability between the thromboelastography and the rotational thromboelastometry viscoelastic point-of-care instruments and to identify knowledge gaps. Methods: Standardized, systematic evaluation of the literature, categorization of relevant articles according to level of evidence and quality, and development of consensus on conclusions for application of the concepts to clinical practice. Methods: Academic and referral veterinary medical centers. Results: Medline via PubMed, CAB abstracts, and Google Scholar were searched. A total of 8 rele...
Harnek J, James SK, Lagerqvist B.Covered stents are mostly used for coronary perforations with a high risk of early adverse events; however, their long-term outcome is unknown. The aim of this study was to elucidate the short- and long-term outcome of patients treated with covered stents compared to all other stented patients. Results: The Swedish national registries from 2005-2017 disclosed 265 patients who had received 366 covered stents. Their outcomes were compared to all other stented patients (197,948) who had received 320,784 stents. Compared to regular stents, covered stents showed significant differences (p<0.001)...
Angeluci GC, Ricci CL, Passareli JVGC, Estanho GJG, Oliveira AS, Santos SGA, Giuffrida R, Rodrigues M, Andrade SF.Measurement of the intraocular pressure (IOP) is a useful diagnostic tool in equine ophthalmology. Handheld tonometers, such as Tonovet and Tonovet Plus (rebound), Tono-Pen AVIA Vet (applanation), and Kowa HA-2 (applanation using the Goldmann methodology) are used to obtain IOP measurements in veterinary medicine. Objective: To compare and evaluate the accuracy of four handheld tonometers in measuring IOP using different methodologies in healthy horses. Methods: In vivo experiment and cross-sectional survey of healthy horses. Methods: Intraocular pressure was measured in 72 eyes of 36 horses. ...
Kanz P, Krieger S, Drillich M, Iwersen M.Pulse oximetry is a well-established technique in human and veterinary medicine. In farm animals, it could also be a useful tool for the detection of critical conditions relating to oxygen supply and the cardiovascular system. Among other uses, an innovative application could be the monitoring of fetuses during birth. This could help in the early identification of critical situations and support farmers and veterinarians in their decision to start obstetric or life-support interventions. Until now, however, its use in ruminant medicine was still limited to experimental applications. The object...
Steffey EP.Both desflurane and sevoflurane offer theoretical and practical advantages over other inhalation anesthetics for horses. The lower solubility of both agents provides improved control of delivery and helps to counteract the confounding influence of the voluminous patient breathing circuit commonly used for anesthetizing horses. The lower solubility should account for faster rates of recovery compared with the older agents; whether or not the quality of recovery differs remains to be objectively evaluated in a broad range of circumstances. The pharmacodynamic effects are, in large part, similar ...
Lacitignola L, Imperante A, De Siena R, Acquafredda C, Trisciuzzi R, Stabile M, Confalonieri E, Crovace AM, Staffieri F.Cryptorchidectomy is the most commonly performed laparoscopic procedure in horses. However, its use for the extraction of an abdominal testis has disadvantages such as loss of a resected testis from grasp and fragmentation of the specimen because of the excessive tension required for extraction through a thick body wall. The ring wound retractor laparoscopic port system was recently used in human and small animal surgery to perform laparoscopic-assisted procedures and retrieve large specimens from the abdomen. In the present case, the wound retractor was placed as the ventral port in the right...
Mustikka MP, Pietilä EM, Mykkänen AK, Grönthal TSC.To obtain a reference range for evaluation of intraocular pressure (IOP) in horses using Tonovet Plus , to compare the IOP readings obtained with Tonovet and Tonovet Plus , and to evaluate the repeatability of readings. Unassigned: Intraocular pressure of 30 client-owned horses (60 eyes) with no signs of illness or ocular disease was evaluated using Tonovet and Tonovet Plus rebound tonometers. Horses' mean age was 10.7 (range 6-17) years. Triplicate measurements were performed without using sedatives or local anesthetics, with minimal restraint. Results: Calculated reference intervals (the CLS...
Dziezyc J, Millichamp NJ, Smith WB.Two Mackay-Marg tonometers and 2 Tono-Pen tonometers were evaluated in eyes in which intraocular pressure (IOP) had been altered and measured by use of a manometer. Eyes of anesthetized dogs and enucleated horse eyes were used. Compared with the manometer, none of the tonometers accurately measured IOP over the range between 0 and 100 mm of Hg. However at manometer measurements from 0 to 30 mm of Hg, several of the tonometers accurately measured IOP. In addition, significant differences were observed when the measurement accuracy of one tonometer was compared with that of another, especially a...
Gingold BM, Killos MB, Griffith E, Posner L.Maintaining adequate muscle tissue oxygenation is of paramount importance during equine general anesthesia. The objectives of this study were to assess the feasibility, reliability and repeatability of near-infrared spectroscopy (NIRS) muscle oximetry using the Inspectra m650 in conscious healthy adult horses. Methods: Prospective, observational study. Methods: A group of 30 healthy client-owned adult horses admitted to the equine hospital between July 2017 and July 2018. Methods: The probe of an Inspectra m650 NIRS tissue oximeter was placed on the hairless surface of five muscle sites (omotr...
Cunneen A, Wood KA, Mathison K, Herndon AM, Bertin FR.Blood glucose is tightly regulated in horses; however, since hypoglycaemia and hyperglycaemia are associated with poor prognosis, close monitoring is warranted. This study aimed at evaluating a continuous indwelling glucometer (CIG) by comparing performance with a point-of-care glucometer (POC). Ten horses were equipped with CIG and an intravenous catheter. Interstitial glucose concentrations were determined by CIG every 5 min at rest, during insulin-induced hypoglycaemia and dextrose-induced hyperglycaemia, and compared with blood glucose determined by POC. Glucose concentrations were compa...
Rickert M, Rauschmann M, Fleege C, Behrbalk E, Harms J.The development of interbody fusion now stretches over many decades and is still not complete. Conclusions: Due to the lack of appropriate implants, the initial fusions were performed via decortication of the dorsal and lateral structures of the spine, followed by placement of an autograft. Despite acceptable fusion results, better primary stability and higher fusion rates were desired. In addition, it became known that the primary load-bearing of the spine is located ventrally in the area of the corpus of the vertebrae. These considerations led to the development of the PLIF technique that wa...
Whitehair KJ, Watney GC, Leith DE, Debowes RM.The clinical usefulness of two pulse oximeters was evaluated at two probe sites in nine anesthetized horses. The hemoglobin saturation determined by the pulse oximeters (SaOx) was compared with the hemoglobin saturation calculated from the measured arterial oxygen tension (SaO2). The mean and standard deviation (SD) were calculated from the differences in saturation measurements, over the saturation range of 80% to 100%, for each oximeter used at the tongue probe site and for one oximeter used at the ear. The oximeter results tended to underestimate the SaO2 with mean differences of -3.7% on t...
Caron JP.Laparoscopic techniques for veterinary surgery are growing in popularity for the same reason the use of minimally invasive procedures has increased tremendously in human surgery. Compared with open surgery, the benefits of laparoscopic surgery include smaller incisions, reduced postoperative morbidity and pain, shorter hospitalization, a more rapid return to normal activities, and, in some instances, superior access. Laparoscopic surgery is different from open surgery in equipment/instrumentation and psychomotor skills. This first article in a series on equine laparoscopic surgery introduces t...
Hendrickson DA.Equine surgery continues to benefit from advances in endoscopic surgical techniques. Much of what we have learned in equine endoscopy comes from techniques used in humans. Descriptions of the normal anatomy of the standing horse and advances in instrumentation have improved our ability to perform laparoscopic surgery in standing and dorsally recumbent horses. This article describes the history of laparoscopy and available instrumentation.
Kamus L, Rameau M, Theoret C.Wounds are among the most common medical conditions affecting horses and have a major economic impact on the horse industry. Wound healing in horses is distinct to that documented in other species, and often results in delayed healing and extensive scarring, with compromised functional and aesthetic outcomes. To date, there is no conventional method objectively proven to accelerate healing or to successfully prevent complications associated with second intention healing. Several effects of Negative Pressure Wound Therapy (NPWT) may be particularly useful to the management of wounds in horses. ...
Trotter GW, McIlwraith CW.Surgical procedures completed under arthroscopic guidance have become commonplace in many equine practices and have largely replaced surgery using arthrotomy incisions. With a limited amount of equipment, numerous diagnostic and surgical procedures can be completed. Surgeons need to become familiar with regional and intraarticular (intrasynovial) anatomy to ensure that proper surgical approaches are used, access to the lesion will be realized, and potential complications will be minimized. Specialized motorized instruments and surgical lasers are now available and may be useful in the treatmen...
Ambrisko TD, Lammer V, Schramel JP, Moens YP.A spirometry device equipped with mainstream CO2 flow sensor is not available for large animal anaesthesia. Objective: To measure the resistance of a new large animal spirometry device and assess its agreement with reference methods for volume measurements. Methods: In vitro experiment and crossover study using anaesthetised horses. Methods: A flow partitioning device (FPD) equipped with 4 human CO2 flow sensors was tested. Pressure differences were measured across the whole FPD and across each sensor separately using air flows (range: 90-720 l/min). One sensor was connected to a spirometry ...
Dunay MP, Németh T, Makra Z, Izing S, Bodó G.In the present series of cases, 8 laparoscopic cryptorchidectomies and 4 laparoscopic ovariectomies were carried out in sedated standing horses. Sedation involved a lesser anaesthesiological risk than does general anaesthesia. As compared to laparotomic exposure, the minimally invasive laparoscopic intervention provided better visualisation, shorter operative time and faster recovery. The blood vessels supplying the testes and ovaries and the suspensory ligaments of the organs were sealed and cut with EnSeal®, an adaptive bipolar electrosurgical blood vessel- and tissue-sealing device. The cl...
Ahern BJ, Lukas E, Lam K, Wilke E, Bertin FR, Van Eps A, Franklin S.To evaluate a prototype dynamic laryngoplasty system (DLPS) in a static airflow model. Methods: Experimental. Methods: Ten equine larynges. Methods: The right arytenoid was fixed in abduction in all specimens. A left-sided laryngoplasty was performed with No. 2 Fiberwire and a FASTakII anchor. Each larynx was tested in a static airflow model. The system was adjusted to a flow rate of 55 L/s and prelaryngeal pressure of 12 mm Hg prior to testing in maximal arytenoid abduction. In phase 1, the left suture was loosened, shortened, and tested in 3-mm steps from 0 to 30 mm. In phase 2, the su...
Geddes LA.The benchmarks in cardiac pacing are identified, beginning with F. Steiner (1871), who rhythmically stimulated the chloroform-arrested hearts of 3 horses, 1 donkey, 10 dogs, 14 cats, and 8 rabbits. The chloroform-arrested heart in human subjects was paced by T. Greene in the following year (1872) in the UK. In 1882, H. Ziemssen in Germany applied cardiac pacing to a 42-year old woman who had a large defect in the anterior left chest wall subsequent to resection of an enchondroma. Intentional cardiac pacing did not occur until 1932, when A.A. Hyman in the US demonstrated that cardiac pacing cou...
Pascoletti G, Pressanto MC, Putame G, Terzini M, Audenino AL, Zanetti EM.A number of surgical practices are aimed to compensate for tissue relaxation or weakened/atrophied muscles by means of suture prostheses/thread lifts. The success rate of these procedures is often very good in the short term, while it is quite variable among subjects and techniques in the middle-long term. Middle-long term failures are mostly related to suture distraction, loosening or wear, coming from repeated loading cycles. In this work, an experimental device to perform ex vivo tests on prosthetic sutures has been set up. An equine laryngoplasty has been used as a benchmark, being represe...
Sanders-Shamis M, Bramlage LR, Weisbrode SE, Gabel AA.The effect of electrical stimulation by means of selected electromagnetic field devices on healing of cannon bone osteotomies in horses was examined. The defects were created as 3 cm x 1 mm longitudinal osteotomies through the dorsal cortices of the mid-metacarpi/metatarsi of adult horses. This type of defect would asses bone healing in a situation similar to an acute, stable fracture of the cortex. Three electromagnetic devices of different design were tested in three different groups of horses. Healing was evaluated radiographically and histologically. Results showed that osteotomies treated...
Latham E, Scherrer NM, Stefanovski D.To compare the measurement of intraocular pressure in horses with clinical ocular disease using three tonometry devices. Conclusions: All three tonometers showed strong agreement, however, the TonoVet and the TonoVet Plus carried the strongest agreement with the TonoVet Plus having slightly higher measurements overall compared with the TonoVet. Due to small variations between devices, it is recommended that the same device be used for serial measurements of intraocular pressure. However, all three devices are appropriate to use in horses presented for ophthalmic evaluation.