Reproducibility of results in equine research refers to the ability to consistently replicate study findings when experiments are repeated under the same conditions. This concept is fundamental in scientific research, as it ensures the reliability and accuracy of experimental outcomes. In equine studies, reproducibility is influenced by various factors, including experimental design, sample size, and the biological variability of horses. Challenges in achieving reproducibility can arise from differences in horse breeds, age, health status, and environmental conditions. This page assembles peer-reviewed research studies and scholarly articles that explore methodologies, statistical approaches, and case studies related to reproducibility in equine research, highlighting its importance in advancing equine science and improving research practices.
Freccero F, Di Maio C, Mariella J, Lanci A, Castagnetti C, Hallowell G.Different methods to measure tissue perfusion are available in equine neonatology, but they are not representative of microvascular derangements. Objective: To evaluate the feasibility of the sidestream dark-field (SDF) capillaroscopy to visualize the capillary microvasculature in conscious newborn foals, the differences between two imaging sites and times of measurements, and the measurements' reproducibility. Methods: Seventeen healthy newborn foals were enrolled. Three sites at the upper and lower lip mucosa were assessed by SDF, using a hand-held capiscope, at 24 h and at 4-5 days after bi...
Timmerman I, Macaire C, Hanne-Poujade S, Bertoni L, Martin P, Marin F, Chateau H.Repeatability and reproducibility of any measuring system must be evaluated to assess possible limitations for its use. The objective of this study was to establish the repeatability and the inter-operator reproducibility of a sensors-based system (EQUISYM®) for quantifying gait asymmetries in horses.. Seven wireless IMUs were placed on the head, the withers, the pelvis, and the 4 cannon bones on three horses, by four different operators, four times on each horse, which led to a total of 48 repetitions randomly assigned. Data were collected along three consecutive days and analysed to calcula...
Bertram CA, Marzahl C, Bartel A, Stayt J, Bonsembiante F, Beeler-Marfisi J, Barton AK, Brocca G, Gelain ME, Gläsel A, Preez KD, Weiler K....Exercise-induced pulmonary hemorrhage (EIPH) is a relevant respiratory disease in sport horses, which can be diagnosed by examination of bronchoalveolar lavage fluid (BALF) cells using the total hemosiderin score (THS). The aim of this study was to evaluate the diagnostic accuracy and reproducibility of annotators and to validate a deep learning-based algorithm for the THS. Digitized cytological specimens stained for iron were prepared from 52 equine BALF samples. Ten annotators produced a THS for each slide according to published methods. The reference methods for comparing annotator's and al...
Fugazzola MC, Wever KE, van de Lest C, de Grauw J, Salvatori D.Animal models continue to be used to investigate cartilage repair strategies. Adequate anaesthesia and pain management are essential in order to guarantee acceptable animal welfare as well as reproducible experimental results. This systematic review evaluates reporting of anaesthesia and pain management in surgical large animal models (horse, pig, dog, goat and sheep) of (osteo)chondral repair. Manuscripts published between 2015 and 2020 were included after a comprehensive search strategy. Data were evaluated using descriptive statistics and qualitative review. Out of 223 eligible studies, 220...
Pyrek P, Siwinska N, Zak-Bochenek A.Control of body condition is an important aspect of horse management. Its correct evaluation, and the possibility of using universal indicators are of key importance for preserving the animals' wellbeing and for providing them with proper care. The objective of this study was to evaluate the agreement between body condition scores assessed by teams and individuals, using the 9-point Body Condition Score scale created by Henneke. The evaluation of a herd of 49 healthy adult Silesian horses was conducted by veterinary medicine students with adequate training in body condition assessment. Group a...
Kam YN, McKenzie K, Coyle M, Bertin FR.Pituitary pars intermedia dysfunction (PPID) is a common endocrinopathy of horses diagnosed with a thyrotropin-releasing hormone (TRH) stimulation test. Objective: Describe the repeatability of TRH stimulation in horses with and without PPID in winter and autumn. Methods: Twenty adult horses; 6 controls and 6 with PPID tested in autumn, 8 controls and 6 with PPID tested in winter with 3 controls and 3 with PPID tested in both seasons. Methods: Thyrotropin-releasing hormone stimulation was performed on 2 consecutive occasions, 1 week before and 1 week after the winter solstice and the autumn ...
Straticò P, Guerri G, Palozzo A, Di Francesco P, Vignoli M, Varasano V, Petrizzi L.Capsulitis leads to the release of inflammatory mediators in the joint, causing capsular fibrosis and osteoarthritis (OA). Strain elastosonography (SE) measures the elasticity of tissue by evaluating its strain in operator-dependent deformation. The aims of the study were to assess the feasibility, repeatability, and reproducibility of SE for imaging the distal attachment of the joint capsule (DJC) of metacarpophalangeal joints in sound horses (Group S) and in horses with metacarpophalangeal OA (Group P) and to evaluate differences in the elastosonographic patterns of these horses. After a who...
Secchi V, Masala G, Corda A, Corda F, Potop E, Barbero Fernandez A, Pinna Parpaglia ML, Sanna Passino E.Early diagnosis of tendon injuries and accurate long-term monitoring of the healing process are key for equine veterinarians that use conventional ultrasonography. The development of strain elastography could improve the management of clinical cases. The aim of the study was to assess the intraobserver repeatability and interobserver reproducibility of manual measurements of the colored areas of the tendons within elastograms and to standardize this manual modality by comparing the analysis of the images with ImageJ. Twenty elastograms of the injured superficial digital flexor tendons (SDFTs) ...
de Oliveira AR, Gozalo-Marcilla M, Ringer SK, Schauvliege S, Fonseca MW, Trindade PHE, Puoli Filho JNP, Luna SPL.The lack of standardization of sedation scales in horses limits the reproducibility between different studies. This prospective, randomized, blinded, horizontal and controlled trial aimed to validate a scale for sedation in horses (EquiSed). Seven horses were treated with intravenous detomidine in low/high doses alone (DL 2.5 μg/kg + 6.25 μg/kg/h; DH 5 μg/kg +12.5 μg/kg/h) or associated with methadone (DLM and DHM, 0.2 mg/kg + 0.05 mg/kg/h) and with low (ACPL 0.02 mg/kg) or high (ACPH 0.09 mg/kg) doses of acepromazine alone. Horses were filmed at (i) baseline (ii) peak, (iii) intermediate,...
Vera L, De Clercq D, Paulussen E, Van Steenkiste G, Decloedt A, Chiers K, van Loon G.In human medicine, local and regional arterial wall stiffness (AWS) parameters are routinely used to assess the vascular health. In horses, information regarding reproducibility of ultrasonographically derived AWS parameters is lacking. Objective: To evaluate the inter-day and inter-observer and intra-observer measurement variability of both local and regional AWS parameters in horses. Methods: Experimental study. Methods: In 10 healthy, adult Warmblood horses, B-, M-mode and pulsed-wave Doppler ultrasound images were collected on two different days from aorta, cranial and caudal common caroti...
Durán-Ferrer M, Agüero M, Zientara S, Beck C, Lecollinet S, Sailleau C, Smith S, Potgieter C, Rueda P, Sastre P, Monaco F, Villalba R....The laboratory diagnosis of African horse sickness (AHS) is important for: (a) demonstrating freedom from infection in a population, animals or products for trade (b) assessing the efficiency of eradication policies; (c) laboratory confirmation of clinical diagnosis; (d) estimating the prevalence of AHS infection; and (e) assessing postvaccination immune status of individual animals or populations. Although serological techniques play a secondary role in the confirmation of clinical cases, their use is very important for all the other purposes due to their high throughput, ease of use and good...
de Almeida MP, Rezende CP, Ferreira FD, de Souza LF, de Assis DC, de Figueiredo TC, de Oliveira Leite M, de Vasconcelos Cançado S.Methods are validated by a process that defines the analytical requirements and confirms that the investigated method is capable of performing consistently. A quantitative and confirmatory method for determining the presence of β-lactam and tetracycline multiresidues in avian, bovine, equine, and swine kidney tissues using ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) was developed, optimized, and validated. Analytes were extracted from the kidneys by a mixture of water and acetonitrile, and the extract was then purified with hexane and C18 (dispersive phase). ...
Ellison ME, Duenwald-Kuehl S, Forrest LJ, Vanderby R, Brounts SH.To evaluate the feasibility and repeatability of in vivo measurement of stiffness gradients by means of acoustoelastography in the superficial digital flexor tendons (SDFTs) of clinically normal horses. Methods: 15 clinically normal horses. Methods: For each horse, stiffness gradient index and dispersion values for SDFTs in both forelimbs were evaluated in longitudinal orientation by use of acoustoelastography at 3 sites (5, 10, and 15 cm distal to the accessory carpal bone) by 2 observers; for each observer, data were acquired twice per site. The left forelimb was always scanned before the ri...
Lustgarten M, Redding WR, Labens R, Morgan M, Davis W, Seiler GS.Tendon and ligament injuries are common causes of impaired performance in equine athletes. Gray-scale ultrasonography is the current standard method for diagnosing and monitoring these injuries, however this modality only provides morphologic information. Elastography is an ultrasound technique that allows detection and measurement of tissue strain, and may provide valuable mechanical information about equine tendon and ligament injuries. The purpose of this study was to determine the feasibility, reproducibility, and repeatability of elastography; and to describe elastographic characteristics...
Gehlen H, Bradaric Z.The evaluation of plasma ACTH and the dexamethasone suppression test are considered the methods of choice to evaluate the course of therapy of pituitary pars intermedia dysfunction (PPID). Sampling protocols as well as vacutainers for analysis differ between the laboratories. To evaluate the reproducability of plasma ACTH measurement between four different laboratories (A, B, C, D) in Germany as well as within the laboratories themselves, ten horses with previously diagnosed PPID and four healthy horses were sampled and analyzed. Each laboratory received two differently labeled samples of each...
Westermann S, Buchner HH, Schramel JP, Tichy A, Stanek C.To assess effects of camera angle and distance on measurement and reproducibility of thermographically determined temperatures of the distolateral aspect of the forelimbs in horses. Methods: Evaluation study. Methods: 10 adult horses. Methods: Thermographic images of both forelimbs were obtained at 3 times during the day (replicates 1, 2, and 3); maximum surface temperature over 1 region (distolateral aspect of the third metacarpal bone and metacarpophalangeal joint) was measured. Standard images were obtained every 5 minutes for 1 hour with the camera positioned at an angle of 90° and a dist...
Slack J, Durandot MM, Belcher CN, Collins N, Palmer L, Ousey J, Birks EK, Marr CM.The repeatability of various echocardiographic measurements is unknown. Objective: To determine the intraoperator, intraobserver and interoperator variability of echocardiographic measures in healthy foals. Methods: Echocardiographic examinations were carried out on 6 healthy foals by 3 experienced echocardiographers. Intraoperator variability was determined by having a single echocardiographer obtain and measure images from 6 foals scanned on 3 consecutive days. Interoperator and intraobserver variability were determined by having 3 echocardiographers each obtain images from an additional 6 s...
Draper AC, Bowen IM, Hallowell GD.The aims of this study were to establish a normal reference range (mean ± 2 SD) and assess reliability of renal dimensions obtained using transabdominal ultrasonography in Thoroughbred horses (n = 7). A minimum of three ultrasonographic cineloops were obtained from each intercostal space and the left paralumbar fossa by two observers daily for three consecutive days. Renal length, width, and thickness and cortex, medulla, and pelvic dimensions were obtained. Measurements were undertaken by both observers, who were unaware of prior measurements, to assess reproducibility and measured on three ...
Suthers JM, Christley RM, Clutton RE.To assess the reproducibility and repeatability of two commonly used recovery quality scoring systems and compare them with those of a novel system based on a greater number of objective criteria. Methods: The video-recorded recoveries of ten client-owned horses selected from all recovery recordings taken between September 2005 and March 2006 at the Royal (Dick) School of Veterinary Studies. Methods: A digital versatile disc (DVD) was produced using edited video recordings of ten horses recovering from general anaesthesia. Twelve experienced equine anaesthetists (raters) studied the DVD on thr...
Norton JL, Nolen-Walston RD, Underwood C, Boston R, Slack J, Dallap BL.Central venous pressure (CVP) is a used as an estimation of intravascular volume status in various species. Techniques for measuring CVP in horses have been described, but the repeatability of these readings at a single time point or over time has not been established. Objective: That CVP measurements in healthy adult horses would be repeatable at each time point, that these readings would be reproducible over time, and that alteration in head position relative to the heart would alter CVP. Methods: Ten healthy adult research horses. Methods: In an experimental study, horses were instrumented ...
Bithell S, Habershon-Butcher JL, Bowen IM, Hallowell GD.The aims of this study were to assess the repeatability and reproducibility of transabdominal ultrasonography to assess intestinal wall thickness in adult Thoroughbred horses (n = 8). Ultrasonographic cineloops were captured by one examiner from each horse for five consecutive days. During each examination at least three cineloops were obtained for five different intestinal tract locations. Measurements were performed by three separate observers to assess reproducibility and measured on three separate occasions by three observers to evaluate short-term repeatability. The repeatability of measu...
Scrivani PV, Levine JM, Holmes NL, Furr M, Divers TJ, Cohen ND.Different examiners or the same examiner were observed at different times producing slightly different results when obtaining cervical-vertebral ratios. If the difference is substantial, then measurement variability would have an important impact of radiographic interpretation. Objective: To quantify agreement and repeatability of these measurements. Methods: An observer agreement study was performed using 75 horses. Measurements were made at C3-4 and C6-7 by a board-certified radiologist and an imaging resident. Intra- and interobserver agreement was quantified using Bland-Altman plots. Repea...
Vettorato E, Chase-Topping ME, Clutton RE.The recovery quality scoring systems (RQSSs) in current use have not been critically reviewed for reliability. Objective: To examine reliability (reproducibility) of 4 RQSSs when applied to a ranked series. Methods: A DVD incorporating the recordings of 9 horses recovering from general anaesthesia was evaluated by final year students over 5 days. On Day 1, each evaluator ranked recoveries from 1-9 (1 = best). Over the following 4 days, each evaluator scored the same recoveries using 4 different RQSSs (3 of them in common usage and previously published) applied in random order. The scores from ...
Nolen-Walston RD, Kuehn H, Boston RC, Mazan MR, Wilkins PA, Bruns S, Hoffman AM.Inflammatory airway disease has a high prevalence in horses, but is often a diagnostic challenge. Flowmetric plethysmography and histamine bronchoprovocation (FP/HBP) is a simple and effective tool for diagnosis, but reproducibility of these measurements made over time has not been established. Objective: We hypothesize that the measurement of airway responsiveness in horses using FP/HBP is consistent over both short and long periods of time. Methods: Twenty-nine healthy adult horses from 2 university herds. Methods: In this prospective experimental study, airway responsiveness was determined ...
Crevier-Denoix N, Ravary-Plumioën B, Evrard D, Pourcelot P.A non-invasive ultrasonic (US) technique of tendon force measurement has been recently developed. It is based on the relationship demonstrated between the speed of sound (SOS) in a tendon and the traction force applied to it. The objectives of the present study were to evaluate the variability of this non-linear relationship among 7 equine superficial digital flexor (SDF) tendons, and the reproducibility of SOS measurements in these tendons over successive loading cycles and tests. Seven SDF tendons were equipped with an US probe (1MHz), secured in contact with the skin overlying the tendon me...
Oosterlinck M, Pille F, Back W, Dewulf J, Gasthuys F.Subtle lameness in horses may be difficult to diagnose and methods to evaluate lameness objectively are useful when equine clinicians fail to reach a consensus. The aim of this study was to determine whether equine pressure plate measurements are repeatable when used to calculate forelimb loading (peak vertical pressure [PVP], peak vertical force [PVF], vertical impulse [VI]) and symmetry ratios, and to establish if these data are similar to the 'gold standard' force plate values. Since plate dimensions are relatively small, ponies were used to enable recordings to be taken from both forelimbs...
Segura D, Monreal L.Template bleeding time (TBT) is considered to be a useful test for detecting platelet function disorders and the effect of platelet-activating drugs, but studies in human medicine have concluded that the test has poor reproducibility and sensitivity. Objective: TBT has poor reproducibility in horses and has insufficient sensitivity to detect the effect of etamsylate on platelet function. Methods: Twenty healthy horses. Methods: TBT was determined and repeated 2 hours and 30 days later. TBT was also performed 2 hours after IV administration of etamsylate. Results: Although no statistical differ...
Menzies-Gow NJ, Marr CM.The repeatability and sensitivity of Doppler ultrasonographic measurement of lateral digital arterial and venous blood flow has not been previously determined. Doppler ultrasonography was used to measure blood flow within the forelimb lateral digital vessels in one normal adult Thoroughbred horse on six occasions and in six normal adult Thoroughbred horses on three occasions, each occasion being at least 1 h apart, to determine the within- and between-horse variation. The values obtained from the right and left lateral digital vessels did not differ significantly. The within-horse coefficients...
Goodwin D, Davidson HP, Harris P.To investigate the choices of foraging location of horses, 10 to 12 horses were introduced for five minutes into each of two similar stables containing a single forage or six forages, in four replicated trials. The horses were then removed and released into the gangway between the stables, and allowed five minutes to choose between the stables. Their initial and final choices, mean duration in each stable and proportional frequency of change of location were compared. Most of the horses initially entered the closest stable on release (P<0.05); if the closest stable contained a single hay, m...
Hackl S, van den Hoven R, Zickl M, Spona J, Zentek J.Few data are available on post-prandial changes of plasma amino acids (AAs) in horses and on the repeatability and the individual variance on different sampling days. The objective of the present study was to measure pre- and post-prandial concentrations of plasma AA in 10 yearling horses. Blood samples were taken on days 1 and 40 of the study before feeding of hay, oats and soya meal and over an 8 h post-prandial period in 2-h intervals. The plasma AAs were measured by high-pressure liquid chromatography after ortho-phthalaldehyde derivatization. Mean fasting concentrations of the AAs were no...
Tunley BV, Henson FM.Thermographic imaging is an increasingly used diagnostic tool. When performing thermography, guidelines suggest that horses should be left for 10-20 mins to 'acclimatise' to the thermographic imaging environment, with no experimental data to substantiate this recommendation. In addition, little objective work has been published on the repeatability and reliability of the data obtained. Thermography has been widely used to identify areas of abnormal body surface temperature in horses with back pathology; however, no normal data is available on the thermographic 'map' of the thoracolumbar region...
Oosterlinck M, Pille F, Back W, Dewulf J, Gasthuys F.Subtle lameness in horses may be difficult to diagnose and methods to evaluate lameness objectively are useful when equine clinicians fail to reach a consensus. The aim of this study was to determine whether equine pressure plate measurements are repeatable when used to calculate forelimb loading (peak vertical pressure [PVP], peak vertical force [PVF], vertical impulse [VI]) and symmetry ratios, and to establish if these data are similar to the 'gold standard' force plate values. Since plate dimensions are relatively small, ponies were used to enable recordings to be taken from both forelimbs...
Pratt SE, Geor RJ, McCutcheon LJ.Both the euglycemic-hyperinsulinemic clamp (EHC) and minimal model analysis of the frequently sampled intravenous glucose tolerance test (FSIGT) have been applied for measurement of insulin sensitivity in horses. However, no published data are available on the reproducibility of these methods. Therefore, the objective of this study was to evaluate the variation and repeatability of measures of glucose dynamics and insulin sensitivity in horses derived from minimal model analysis of the FSIGT and from the EHC method. Six healthy horses underwent both the FSIGT and EHC on 2 occasions over a 4-we...
Pickersgill CH, Marr CM, Reid SW.A quantitative investigation of the variation that can occur during the course of ultrasonography of the equine superficial digital flexor tendons (SDFT) was undertaken. The aim of this investigation was to use an objective measure, namely the measurement of CSA, to quantify the variability occurring during the course of the ultrasonographic assessment of the equine SDFT. The effects of 3 variables on the CSA measurements were determined. 1) Image acquisition operator (IAc): two different operators undertaking the ultrasonographic examination; 2) image analysis operator (IAn): two different op...
Mawdsley A, Kelly EP, Smith FH, Brophy PO.A linear assessment trait evaluation system is proposed to allow quantitative description of the static conformation of the horse. Measurements were made on 27 selected traits. The system was tested initially for repeatability of measurements on 4 horses. Twenty-one of the selected traits were satisfactory and 6 proved unsatisfactory in terms of reproducibility. A population of 101, superior 2- and 3-year-old Thoroughbreds and 19 premium Thoroughbred stallions were similarly assessed. More than 65% of the traits exhibited large (CV > 10%) phenotypic variation within the sampled population. ...
Crevier-Denoix N, Ravary-Plumioën B, Evrard D, Pourcelot P.A non-invasive ultrasonic (US) technique of tendon force measurement has been recently developed. It is based on the relationship demonstrated between the speed of sound (SOS) in a tendon and the traction force applied to it. The objectives of the present study were to evaluate the variability of this non-linear relationship among 7 equine superficial digital flexor (SDF) tendons, and the reproducibility of SOS measurements in these tendons over successive loading cycles and tests. Seven SDF tendons were equipped with an US probe (1MHz), secured in contact with the skin overlying the tendon me...
Bithell S, Habershon-Butcher JL, Bowen IM, Hallowell GD.The aims of this study were to assess the repeatability and reproducibility of transabdominal ultrasonography to assess intestinal wall thickness in adult Thoroughbred horses (n = 8). Ultrasonographic cineloops were captured by one examiner from each horse for five consecutive days. During each examination at least three cineloops were obtained for five different intestinal tract locations. Measurements were performed by three separate observers to assess reproducibility and measured on three separate occasions by three observers to evaluate short-term repeatability. The repeatability of measu...
Westermann S, Buchner HH, Schramel JP, Tichy A, Stanek C.To assess effects of camera angle and distance on measurement and reproducibility of thermographically determined temperatures of the distolateral aspect of the forelimbs in horses. Methods: Evaluation study. Methods: 10 adult horses. Methods: Thermographic images of both forelimbs were obtained at 3 times during the day (replicates 1, 2, and 3); maximum surface temperature over 1 region (distolateral aspect of the third metacarpal bone and metacarpophalangeal joint) was measured. Standard images were obtained every 5 minutes for 1 hour with the camera positioned at an angle of 90° and a dist...
Slack J, Durandot MM, Belcher CN, Collins N, Palmer L, Ousey J, Birks EK, Marr CM.The repeatability of various echocardiographic measurements is unknown. Objective: To determine the intraoperator, intraobserver and interoperator variability of echocardiographic measures in healthy foals. Methods: Echocardiographic examinations were carried out on 6 healthy foals by 3 experienced echocardiographers. Intraoperator variability was determined by having a single echocardiographer obtain and measure images from 6 foals scanned on 3 consecutive days. Interoperator and intraobserver variability were determined by having 3 echocardiographers each obtain images from an additional 6 s...
Suthers JM, Christley RM, Clutton RE.To assess the reproducibility and repeatability of two commonly used recovery quality scoring systems and compare them with those of a novel system based on a greater number of objective criteria. Methods: The video-recorded recoveries of ten client-owned horses selected from all recovery recordings taken between September 2005 and March 2006 at the Royal (Dick) School of Veterinary Studies. Methods: A digital versatile disc (DVD) was produced using edited video recordings of ten horses recovering from general anaesthesia. Twelve experienced equine anaesthetists (raters) studied the DVD on thr...
Nolen-Walston RD, Kuehn H, Boston RC, Mazan MR, Wilkins PA, Bruns S, Hoffman AM.Inflammatory airway disease has a high prevalence in horses, but is often a diagnostic challenge. Flowmetric plethysmography and histamine bronchoprovocation (FP/HBP) is a simple and effective tool for diagnosis, but reproducibility of these measurements made over time has not been established. Objective: We hypothesize that the measurement of airway responsiveness in horses using FP/HBP is consistent over both short and long periods of time. Methods: Twenty-nine healthy adult horses from 2 university herds. Methods: In this prospective experimental study, airway responsiveness was determined ...
Degueurce C, Pourcelot P, Audigié F, Denoix JM, Geiger D.The reproducibility of gait variables for sound horses is essential for the interpretation of their modifications by locomotor disorders. Therefore, the purpose of this study was to evaluate the variability of the limb joint angle patterns in a population of sound horses while they trotted in the conditions of the routine lameness examination (slow trot, just held by hand, on a track, outdoors). The kinematics of 14 French Saddle horses was recorded using a 3-dimensional (3D) kinematic analysis system. Angle-time diagrams were established in the sagittal plane and their intra- and inter-indivi...
Vettorato E, Chase-Topping ME, Clutton RE.The recovery quality scoring systems (RQSSs) in current use have not been critically reviewed for reliability. Objective: To examine reliability (reproducibility) of 4 RQSSs when applied to a ranked series. Methods: A DVD incorporating the recordings of 9 horses recovering from general anaesthesia was evaluated by final year students over 5 days. On Day 1, each evaluator ranked recoveries from 1-9 (1 = best). Over the following 4 days, each evaluator scored the same recoveries using 4 different RQSSs (3 of them in common usage and previously published) applied in random order. The scores from ...
Lustgarten M, Redding WR, Labens R, Morgan M, Davis W, Seiler GS.Tendon and ligament injuries are common causes of impaired performance in equine athletes. Gray-scale ultrasonography is the current standard method for diagnosing and monitoring these injuries, however this modality only provides morphologic information. Elastography is an ultrasound technique that allows detection and measurement of tissue strain, and may provide valuable mechanical information about equine tendon and ligament injuries. The purpose of this study was to determine the feasibility, reproducibility, and repeatability of elastography; and to describe elastographic characteristics...
Hackl S, van den Hoven R, Zickl M, Spona J, Zentek J.Few data are available on post-prandial changes of plasma amino acids (AAs) in horses and on the repeatability and the individual variance on different sampling days. The objective of the present study was to measure pre- and post-prandial concentrations of plasma AA in 10 yearling horses. Blood samples were taken on days 1 and 40 of the study before feeding of hay, oats and soya meal and over an 8 h post-prandial period in 2-h intervals. The plasma AAs were measured by high-pressure liquid chromatography after ortho-phthalaldehyde derivatization. Mean fasting concentrations of the AAs were no...
Draper AC, Bowen IM, Hallowell GD.The aims of this study were to establish a normal reference range (mean ± 2 SD) and assess reliability of renal dimensions obtained using transabdominal ultrasonography in Thoroughbred horses (n = 7). A minimum of three ultrasonographic cineloops were obtained from each intercostal space and the left paralumbar fossa by two observers daily for three consecutive days. Renal length, width, and thickness and cortex, medulla, and pelvic dimensions were obtained. Measurements were undertaken by both observers, who were unaware of prior measurements, to assess reproducibility and measured on three ...
Segura D, Monreal L.Template bleeding time (TBT) is considered to be a useful test for detecting platelet function disorders and the effect of platelet-activating drugs, but studies in human medicine have concluded that the test has poor reproducibility and sensitivity. Objective: TBT has poor reproducibility in horses and has insufficient sensitivity to detect the effect of etamsylate on platelet function. Methods: Twenty healthy horses. Methods: TBT was determined and repeated 2 hours and 30 days later. TBT was also performed 2 hours after IV administration of etamsylate. Results: Although no statistical differ...
Timmerman I, Macaire C, Hanne-Poujade S, Bertoni L, Martin P, Marin F, Chateau H.Repeatability and reproducibility of any measuring system must be evaluated to assess possible limitations for its use. The objective of this study was to establish the repeatability and the inter-operator reproducibility of a sensors-based system (EQUISYM®) for quantifying gait asymmetries in horses.. Seven wireless IMUs were placed on the head, the withers, the pelvis, and the 4 cannon bones on three horses, by four different operators, four times on each horse, which led to a total of 48 repetitions randomly assigned. Data were collected along three consecutive days and analysed to calcula...
Leleu C, Bariller F, Cotrel C, Barrey E.Locomotion analysis is increasingly used to assess the gait of horses in the selection and training of equine athletes. We have developed a specific locomotor test for fast trotting harnessed horses that uses an accelerometric device. We describe here the reproducibility of the locomotor test and the validation of its use to analyse trotters on the racetrack. We measured the performance of eight horses under the same conditions three times in a single week. We then tested the influence of five tracks on the variables measured using eight different trotters every two days. The horses trotted at...
Kriz NG, Rose RJ.To assess the repeatability of commonly employed transthoracic echocardiographic measurements in standing horses. Methods: Thirteen healthy 3- to 4-year-old fit Standardbred geldings with a mean weight of 411 (SEM +/- 10) kg were studied. The horses' environment, feeding and management regimens were standardised. All measurements were performed by the same investigator at the same time every day for three consecutive days. Methods: Standard transthoracic measurements were made on all horses. Each measurement was performed over three consecutive cardiac cycles on 1 day and all measurements were...
Goodwin D, Davidson HP, Harris P.To investigate the choices of foraging location of horses, 10 to 12 horses were introduced for five minutes into each of two similar stables containing a single forage or six forages, in four replicated trials. The horses were then removed and released into the gangway between the stables, and allowed five minutes to choose between the stables. Their initial and final choices, mean duration in each stable and proportional frequency of change of location were compared. Most of the horses initially entered the closest stable on release (P<0.05); if the closest stable contained a single hay, m...
Fugazzola MC, Wever KE, van de Lest C, de Grauw J, Salvatori D.Animal models continue to be used to investigate cartilage repair strategies. Adequate anaesthesia and pain management are essential in order to guarantee acceptable animal welfare as well as reproducible experimental results. This systematic review evaluates reporting of anaesthesia and pain management in surgical large animal models (horse, pig, dog, goat and sheep) of (osteo)chondral repair. Manuscripts published between 2015 and 2020 were included after a comprehensive search strategy. Data were evaluated using descriptive statistics and qualitative review. Out of 223 eligible studies, 220...
Schramme MC, Boswell JC, Hamhougias K, Toulson K, Viitanen M.Numerous different techniques for injection of the navicular bursa have been described but there is little conformity between these descriptions. A literature review was performed and techniques for injection of the navicular bursa were categorised into 5 approaches. This study was performed to evaluate the reproducibility of each technique and to assess which technique was consistently most successful. Five inexperienced operators performed each technique on 5 cadaver forelimbs. Once a needle had been placed, a radiograph was taken to confirm placement was in accordance with the description o...
Kam YN, McKenzie K, Coyle M, Bertin FR.Pituitary pars intermedia dysfunction (PPID) is a common endocrinopathy of horses diagnosed with a thyrotropin-releasing hormone (TRH) stimulation test. Objective: Describe the repeatability of TRH stimulation in horses with and without PPID in winter and autumn. Methods: Twenty adult horses; 6 controls and 6 with PPID tested in autumn, 8 controls and 6 with PPID tested in winter with 3 controls and 3 with PPID tested in both seasons. Methods: Thyrotropin-releasing hormone stimulation was performed on 2 consecutive occasions, 1 week before and 1 week after the winter solstice and the autumn ...
Scrivani PV, Levine JM, Holmes NL, Furr M, Divers TJ, Cohen ND.Different examiners or the same examiner were observed at different times producing slightly different results when obtaining cervical-vertebral ratios. If the difference is substantial, then measurement variability would have an important impact of radiographic interpretation. Objective: To quantify agreement and repeatability of these measurements. Methods: An observer agreement study was performed using 75 horses. Measurements were made at C3-4 and C6-7 by a board-certified radiologist and an imaging resident. Intra- and interobserver agreement was quantified using Bland-Altman plots. Repea...
de Almeida MP, Rezende CP, Ferreira FD, de Souza LF, de Assis DC, de Figueiredo TC, de Oliveira Leite M, de Vasconcelos Cançado S.Methods are validated by a process that defines the analytical requirements and confirms that the investigated method is capable of performing consistently. A quantitative and confirmatory method for determining the presence of β-lactam and tetracycline multiresidues in avian, bovine, equine, and swine kidney tissues using ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) was developed, optimized, and validated. Analytes were extracted from the kidneys by a mixture of water and acetonitrile, and the extract was then purified with hexane and C18 (dispersive phase). ...
Vera L, De Clercq D, Paulussen E, Van Steenkiste G, Decloedt A, Chiers K, van Loon G.In human medicine, local and regional arterial wall stiffness (AWS) parameters are routinely used to assess the vascular health. In horses, information regarding reproducibility of ultrasonographically derived AWS parameters is lacking. Objective: To evaluate the inter-day and inter-observer and intra-observer measurement variability of both local and regional AWS parameters in horses. Methods: Experimental study. Methods: In 10 healthy, adult Warmblood horses, B-, M-mode and pulsed-wave Doppler ultrasound images were collected on two different days from aorta, cranial and caudal common caroti...
Straticò P, Guerri G, Palozzo A, Di Francesco P, Vignoli M, Varasano V, Petrizzi L.Capsulitis leads to the release of inflammatory mediators in the joint, causing capsular fibrosis and osteoarthritis (OA). Strain elastosonography (SE) measures the elasticity of tissue by evaluating its strain in operator-dependent deformation. The aims of the study were to assess the feasibility, repeatability, and reproducibility of SE for imaging the distal attachment of the joint capsule (DJC) of metacarpophalangeal joints in sound horses (Group S) and in horses with metacarpophalangeal OA (Group P) and to evaluate differences in the elastosonographic patterns of these horses. After a who...
Secchi V, Masala G, Corda A, Corda F, Potop E, Barbero Fernandez A, Pinna Parpaglia ML, Sanna Passino E.Early diagnosis of tendon injuries and accurate long-term monitoring of the healing process are key for equine veterinarians that use conventional ultrasonography. The development of strain elastography could improve the management of clinical cases. The aim of the study was to assess the intraobserver repeatability and interobserver reproducibility of manual measurements of the colored areas of the tendons within elastograms and to standardize this manual modality by comparing the analysis of the images with ImageJ. Twenty elastograms of the injured superficial digital flexor tendons (SDFTs) ...
Ellison ME, Duenwald-Kuehl S, Forrest LJ, Vanderby R, Brounts SH.To evaluate the feasibility and repeatability of in vivo measurement of stiffness gradients by means of acoustoelastography in the superficial digital flexor tendons (SDFTs) of clinically normal horses. Methods: 15 clinically normal horses. Methods: For each horse, stiffness gradient index and dispersion values for SDFTs in both forelimbs were evaluated in longitudinal orientation by use of acoustoelastography at 3 sites (5, 10, and 15 cm distal to the accessory carpal bone) by 2 observers; for each observer, data were acquired twice per site. The left forelimb was always scanned before the ri...