Analyze Diet

Topic:Sensitivity and Specificity

Sensitivity and specificity are statistical measures used to evaluate the performance of diagnostic tests in horses. Sensitivity refers to the ability of a test to correctly identify horses with a particular disease or condition, while specificity refers to the ability of the test to correctly identify horses that do not have the disease. These metrics are fundamental in assessing the accuracy and reliability of diagnostic tools used in equine medicine. High sensitivity reduces the chance of false negatives, whereas high specificity reduces the chance of false positives. This page compiles peer-reviewed research studies and scholarly articles that explore the application, interpretation, and implications of sensitivity and specificity in equine diagnostics.
Comparison of radiography and ultrasonography to detect osteochondrosis lesions in the tarsocrural joint: a prospective study.
Equine veterinary journal    March 24, 2009   Volume 41, Issue 1 34-40 doi: 10.2746/042516408x343019
Relave F, Meulyzer M, Alexander K, Beauchamp G, Marcoux M.Lesions located on the medial malleolus of the tarsocrural joint can be difficult to image radiographically. Ultrasonography allows evaluation of articular cartilage and subchondral bone. Objective: To compare dorso30 degrees lateral-plantaromedial-oblique (DL-PIMO) and dorso45 degrees views to detect lesions on the medial malleolus, to validate the use of ultrasonography to show lesions in the tarsocrural joint and to compare its sensitivity to radiography. Methods: Tarsocrural joints (n=111) with osteochondrosis were evaluated ultrasonographically and radiographically prior to arthroscopic l...
Evaluation of duration of corneal anesthesia induced with ophthalmic 0.5% proparacaine hydrochloride by use of a Cochet-Bonnet aesthesiometer in clinically normal horses.
American journal of veterinary research    December 3, 2008   Volume 69, Issue 12 1655-1658 doi: 10.2460/ajvr.69.12.1655
Kalf KL, Utter ME, Wotman KL.To measure duration of corneal anesthesia and time and degree of maximal anesthetic effect of 0.5% proparacaine hydrochloride by use of a Cochet-Bonnet aesthesiometer in horses. Methods: 10 clinically normal adult horses. Methods: Baseline corneal touch threshold (CTT) was measured in millimeters for 1 randomly selected eye of each horse by use of the aesthesiometer by applying the filament to the cornea at maximum length (60 mm) and decreasing in 5-mm increments until a consistent blink response was elicited. Following baseline CTT measurement, 0.2 mL of 0.5% proparacaine hydrochloride was in...
Validation of an in-clinic enzyme-linked immunosorbent assay kit for diagnosis of Borrelia burgdorferi infection in horses. Johnson AL, Divers TJ, Chang YF.Confirmation of Borrelia burgdorferi infection in horses has required enzyme-linked immunosorbent assay (ELISA) or Western blot tests performed by reference laboratories. An in-clinic C6 ELISA SNAP kit has been marketed for dogs. This canine kit was evaluated for horses using serum from experimentally infected ponies. Serum samples originated from 2 previous studies. In the first study, 7 ponies were exposed to B. burgdorferi-infected ticks; 4 ponies served as uninfected controls. Serum samples were obtained bimonthly for 9 months. In the second study, 16 ponies were exposed to B. burgdorferi-...
Diagnostic sensitivity of nasopharyngeal and nasal swabs for the molecular detection of EHV-1.
The Veterinary record    April 22, 2008   Volume 162, Issue 16 520-521 doi: 10.1136/vr.162.16.520
Pusterla N, Mapes S, Wilson WD.No abstract available
The efficacy of a commercial ELISA as an alternative to virus neutralisation test for the detection of antibodies to EAV.
Equine veterinary journal    February 13, 2008   Volume 40, Issue 2 182-183 doi: 10.2746/042516408X276951
Duthie S, Mills H, Burr P.Infection with equine arteritis virus is a notifiable disease with sporadic occurrence in the UK. As stallions may harbour the virus after infection, horses are screened for exposure by serological testing prior to breeding. The virus neutralisation test is considered the 'gold standard' serological screening test, but it is time-consuming and labour intensive; consequently there is a move towards more rapid screening methodology. In this study, a commercially available EVA antibody ELISA is assessed. The ELISA performed poorly with a specificity [corrected] of 26% and a sensitivity [corrected...
Verification of scintigraphic imaging for injury diagnosis in 264 horses with foot pain.
Equine veterinary journal    August 29, 2007   Volume 39, Issue 4 350-355 doi: 10.2746/042516407x185430
Dyson S, Murray R.Nuclear scintigraphy is commonly used as a diagnostic aid for foot pain, but there is limited information about different patterns of radiopharmaceutical uptake (RU) and their correlation with the results of other imaging modalities. Objective: To describe patterns of RU in horses with foot pain. Methods: Scintigraphic images of the feet of 264 horses with front foot pain were analysed subjectively and using region of interest analysis. Magnetic resonance images of all feet were analysed prospectively; the navicular bones were reassessed retrospectively and assigned a grade. A Spearman rank co...
Validation of the indirect fluorescent antibody and the complement fixation tests for the diagnosis of Theileria equi.
Veterinary parasitology    July 13, 2007   Volume 148, Issue 2 102-108 doi: 10.1016/j.vetpar.2007.06.006
Ogunremi O, Georgiadis MP, Halbert G, Benjamin J, Pfister K, Lopez-Rebollar L.The indirect fluorescent antibody (IFA) test for Theileria equi was evaluated to assess test's suitability for the serological diagnosis of equine piroplasmosis, to provide performance parameters for the purpose of test validation, and to compare it with the complement fixation (CF) test. Using a protocol that included Evan's blue, the specificity of the IFA test was estimated at 99.0% for T. equi by the classical method of analysis, and 96.6% by the Bayesian method. The use of Evan's blue in the test protocol increased test specificity and contributed to an excellent test agreement between tw...
Repeatability of Doppler ultrasonographic measurement of equine digital blood flow. Menzies-Gow NJ, Marr CM.The repeatability and sensitivity of Doppler ultrasonographic measurement of lateral digital arterial and venous blood flow has not been previously determined. Doppler ultrasonography was used to measure blood flow within the forelimb lateral digital vessels in one normal adult Thoroughbred horse on six occasions and in six normal adult Thoroughbred horses on three occasions, each occasion being at least 1 h apart, to determine the within- and between-horse variation. The values obtained from the right and left lateral digital vessels did not differ significantly. The within-horse coefficients...
[Detection of rhodococcus equi by microbiological culture and by polymerase chain reaction in samples of tracheobronchial secretions of foals].
Berliner und Munchener tierarztliche Wochenschrift    April 10, 2007   Volume 120, Issue 3-4 126-133 
Venner M, Heyers P, Strutzberg-Minder K, Lorenz N, Verspohl J, Klug E.The goal of the present study was to investigate whether new PCR-methods would improve diagnostic of R. equi. In a first step, sensitivity and specificity of the PCR-methods in respect to the"gold standard" microbiological culture were determined. Secondly, sensitivity and specificity of both microbiological methods were evaluated in respect to the clinical diagnosis. The tracheobronchial secretions of 48 foals with pulmonary abscesses and of 37 healthy foals were evaluated by bacteriological culture as well as by four PCR-methods: aceA-, ideR-, vapA- and VP-PCR. In respect to the"gold standar...
Evaluation of the combined dexamethasone suppression/ thyrotropin-releasing hormone stimulation test for detection of pars intermedia pituitary adenomas in horses.
Journal of veterinary internal medicine    September 8, 2006   Volume 20, Issue 4 987-993 doi: 10.1892/0891-6640(2006)20[987:eotcdt]2.0.co;2
Frank N, Andrews FM, Sommardahl CS, Eiler H, Rohrbach BW, Donnell RL.A combined dexamethasone (DEX) suppression/thyrotropin-releasing hormone (TRH) test (DEX/TRH test) has been developed to evaluate horses for presence of a pars intermedia pituitary adenoma (PIPA), but to the authors' knowledge, the accuracy of this test has not been previously determined. Objective: The sensitivity and specificity of the DEX/TRH test can be determined by comparing test results with histopathologic examination findings. Methods: Age of 42 horses of various breeds ranged from 2 to 33 years. Methods: Plasma cortisol concentration was measured before and 24 hours after IV administ...
Diagnostic performance of the equine IgM capture ELISA for serodiagnosis of West Nile virus infection.
Journal of veterinary internal medicine    June 1, 2006   Volume 20, Issue 3 608-613 doi: 10.1892/0891-6640(2006)20[608:dpotei]2.0.co;2
Long MT, Jeter W, Hernandez J, Sellon DC, Gosche D, Gillis K, Bille E, Gibbs EP.The objectives of these studies were to assess the diagnostic performance (sensitivity and specificity) of the IgM capture enzyme-linked immunosorbent assay (ELISA; MAC) for diagnosis of West Nile (WN) virus in horses and to examine the performance of this test by using different criteria for seropositivity. A total of 36 horses classified as WN virus infected (group 1) and 383 horses from 4 subpopulations of hoses classified as noninfected (groups 2, 3, 4, and 5) were used in the study. The sensitivity (proportion of infected horses that tested positive for WN virus IgM antibodies) and specif...
Screening for basic drugs in equine urine using direct-injection differential-gradient LC-LC coupled to hybrid tandem MS/MS.
Journal of chromatography. B, Analytical technologies in the biomedical and life sciences    April 17, 2006   Volume 836, Issue 1-2 1-14 doi: 10.1016/j.jchromb.2006.03.034
Stanley SM, Foo HC.A rapid, selective and robust direct-injection LC/hybrid tandem MS method has been developed for simultaneous screening of more than 250 basic drugs in the supernatant of enzyme hydrolysed equine urine. Analytes, trapped using a short HLB extraction column, are refocused and separated on a Sunfire C(18) analytical column using a controlled differential gradient generated by proportional dilution of the first column's eluent with water. Independent data acquisition (IDA) was configured to trigger a sensitive enhanced product ion (EPI) scan when a multiple reaction monitoring (MRM) survey scan s...
Equine Culicoides hypersensitivity: evaluation of a skin test and of humoral response.
Journal of veterinary medicine. A, Physiology, pathology, clinical medicine    January 18, 2006   Volume 53, Issue 1 30-33 doi: 10.1111/j.1439-0442.2006.00783.x
Ferroglio E, Pregel P, Accossato A, Taricco I, Bollo E, Rossi L, Trisciuoglio A.Intradermal tests were carried out on 18 horses with clinical signs of Culicoides hypersensitivity (CHS) and 23 horses without clinical signs of CHS, and sera from these horses were analysed by SDS-PAGE and Western blotting (W-B). Intradermal injections of 0.1 ml of 25 microg/microl sterile Culicoides extract, 0.1 ml of 1:10,000 histamine (positive control) and 0.1 ml of physiological saline (negative control) were made in the dermis of the middle region of the neck. Analysis of reactions indicated that a 1 cm wheal and a skinfold thickness >10% at 24 h represented a valid cut-off between h...
Observer variation in visual assessment of forelimb horseshoe characteristics on Thoroughbred racehorses.
American journal of veterinary research    January 6, 2005   Volume 65, Issue 12 1674-1679 doi: 10.2460/ajvr.2004.65.1674
Gross DK, Stover SM, Hill AE, Gardner IA.To assess the accuracy and reliability of a visual method of evaluating horseshoe characteristics. Methods: 1,199 Thoroughbred racehorses. Methods: Characteristics of 1 forelimb horseshoe were visually assessed on horses immediately prior to racing by 5 field observers at 5 major racetracks in California. Characteristics evaluated included horseshoe type; toe grab height; and the presence of a rim, pad, and heel traction devices. Sensitivity and specificity for observer assessment of horseshoe characteristics were calculated by comparing observer assessments to a postmortem laboratory standard...
Sensitivity of commercial prothrombin time reagents to detect coagulation factor deficiencies in equine plasma.
Veterinary journal (London, England : 1997)    November 19, 2004   Volume 171, Issue 1 114-119 doi: 10.1016/j.tvjl.2004.09.003
Mischke R, Junker J, Deegen E.The sensitivity of commercial prothrombin time (PT) tests was assessed based on a dilution series of equine pooled plasma (EPP) (experiment 1) and on 40 equine plasma samples with reduced activity of coagulation factors II, V, VII and X (experiment 2). Two different PT reagents (reagent 1, human placental thromboplastin; reagent 2, recombinant human tissue factor) were used according to the manufacturers' instructions (standard test, PT([ST])) and compared to a modified test procedure (modified test, PT([MT])) using sample dilution and fibrinogen addition. In all samples, sensitivity was lower...
[Reliability of the glutaraldehyde test to measure gamma-globulin levels in foals and the use of this test to check colostrum intake of foals].
Tijdschrift voor diergeneeskunde    May 2, 2003   Volume 128, Issue 8 240-246 
de Bruijn CM, Wensing T, van Nieuwstadt RA.The glutaraldehyde coagulation test is a semi-quantitative test used to determine the gammaglobulin concentration in serum. The purpose of this study was to examine the reliability of the different modifications of this test by determining the sensitivity, specificity, positive and negative predictive value, and the prevalence of hypogammaglobulinemia in foals. The results of the glutaraldehyde coagulation test were compared with the serum gammaglobulin concentration as a reference value, determined by measuring total serum protein and the serum protein spectrum. It was concluded that the glut...
Performance of five serological assays for diagnosis of Rhodococcus equi pneumonia in foals.
Clinical and diagnostic laboratory immunology    March 11, 2003   Volume 10, Issue 2 241-245 doi: 10.1128/cdli.10.2.241-245.2003
Giguère S, Hernandez J, Gaskin J, Prescott JF, Takai S, Miller C.The performance of four enzyme-linked immunosorbent assays (ELISAs) (ELISA-6939, ELISA-33701, ELISA-VapA, and ELISA-California) and an agar gel immunodiffusion test for diagnosis of Rhodococcus equi pneumonia in foals was evaluated. Antibody concentrations of foals with culture-confirmed R. equi pneumonia (n = 41) were compared to those of age-matched pasturemates that remained clinically healthy during the entire breeding season (n = 24). For each serological assay evaluated, selection of a low cutoff resulted in high sensitivity but low specificity. Increasing the cutoff value resulted in be...
Standardisation and comparison of serial dilution and single dilution enzyme linked immunosorbent assay (ELISA) using different antigenic preparations of the Babesia (Theileria) equi parasite.
Veterinary research    February 18, 2003   Volume 34, Issue 1 71-83 doi: 10.1051/vetres:2002055
Kumar S, Kumar Y, Malhotra DV, Dhar S, Nichani AK.Serial dilution and single dilution enzyme linked immunosorbent assays (ELISA) were standardised and their sensitivity and specificity were compared for serodiagnosis of Babesia equi infection. The antibody titres of 24 donkey sera of known identity were determined separately by serial dilution ELISA using three different B. equi antigens namely whole merozoite (WM), cell membrane (CM) and high speed supernatant (HSS). The ratios of the optical density (OD) of known positive and known negative sera at different serum dilutions were calculated and termed as the positive/negative (P/N) ratio. Th...
Comparison of a serum indirect fluorescent antibody test with two Western blot tests for the diagnosis of equine protozoal myeloencephalitis. Duarte PC, Daft BM, Conrad PA, Packham AE, Gardner IA.A serum indirect fluorescent antibody test (IFAT) was compared with a Western blot (WB) and a modified Western blot (mWB) for diagnosis of equine protozoal myeloencephalitis (EPM). Using receiver-operating characteristic (ROC) analysis, the area under the curve of the IFAT was greater than the areaunder the curves of the WB and the mWB (P = 0.025 and P = 0.044, respectively). There was no statistically significant difference between the areas under the curves of the WBs (P > 0.05). On the basis of an arbitrarily chosen cut-off titer for a positive test result of 1:80 for the IFAT and interpret...
Sensitivity and specificity of western blot testing of cerebrospinal fluid and serum for diagnosis of equine protozoal myeloencephalitis in horses with and without neurologic abnormalities.
Journal of the American Veterinary Medical Association    October 9, 2002   Volume 221, Issue 7 1007-1013 doi: 10.2460/javma.2002.221.1007
Daft BM, Barr BC, Gardner IA, Read D, Bell W, Peyser KG, Ardans A, Kinde H, Morrow JK.To determine sensitivity and specificity of western blot testing (WBT) of CSF and serum for diagnosis of equine protozoal myeloencephalitis (EPM) in horses with and without neurologic abnormalities. Methods: Prospective investigation. Methods: 65 horses with and 169 horses without neurologic abnormalities. Methods: CSF and serum from horses submitted for necropsy were tested for Sarcocystis neurona-specific antibody with a WBT. Results of postmortem examination were used as the gold standard against which results of the WBT were compared. Results: Sensitivity of WBT of CSF was 87% for horses w...
The use of a neutralizing monoclonal antibody to detect infections of equine herpesvirus type 2 (EHV-2). Nordengrahn A, Klingeborn B, Lindholm A, Merza M.A blocking enzyme-linked immunosorbent assay (ELISA) was developed to detect antibodies to equine herpesvirus 2 in serum samples of horses. By measuring the binding to a single epitope, this blocking ELISA gives a good picture of the antibody status in the animal. The test is based on a monoclonal antibody with neutralizing activity and had a sensitivity of 94% and a specificity of 100%. Antibodies due to newly acquired infection in foals were successfully detected with this blocking ELISA.
Comparison of nucleic acid amplification, serology, and microbiologic culture for diagnosis of Rhodococcus equi pneumonia in foals.
Journal of clinical microbiology    April 3, 2001   Volume 39, Issue 4 1289-1293 doi: 10.1128/JCM.39.4.1289-1293.2001
Sellon DC, Besser TE, Vivrette SL, McConnico RS.Recently, a technique was described for amplification of Rhodococcus equi-specific chromosomal and vapA DNA from blood and tracheal wash fluids. It was hypothesized that this technique would be more sensitive than standard culture techniques or serology for diagnosis of R. equi pneumonia in foals. Tracheal wash fluid, nasal swabs, whole blood samples, and serum samples from 56 foals with pneumonia were analyzed. Final clinical diagnosis was determined by the attending clinician on the basis of final interpretation of all available information about each foal, including clinical presentation, d...
Rapid PCR detection of Salmonella in horse faecal samples.
Veterinary microbiology    March 7, 2001   Volume 79, Issue 1 63-74 doi: 10.1016/s0378-1135(00)00340-0
Amavisit P, Browning GF, Lightfoot D, Church S, Anderson GA, Whithear KG, Markham PF.A rapid polymerase chain reaction (PCR) assay was developed for detecting Salmonella in faeces of horses and assessed on samples from horses admitted to a veterinary hospital. Direct detection was achieved by amplification of part of ompC after extraction of DNA from faeces using a spin column method to reduce the amount of inhibitory substances in samples. An internal positive control was included to detect false negative results. While the sensitivity of the PCR assay was less than culture when assessed on faeces inoculated with Salmonella, its sensitivity on faecal samples obtained from hor...
Determination of testosterone:epitestosterone ratio after pentafluorophenyldimethylsilyl-trimethylsilyl derivatisation using gas chromatography-mass spectrometry in equine urine.
The Analyst    January 5, 2000   Volume 124, Issue 5 675-678 doi: 10.1039/a901242g
Choi MH, Kim JY, Chung BC.A highly specific method is described for measuring the testosterone:epitestosterone ratio in equine urine by gas chromatography-mass spectrometry (GC-MS) with stable isotope internal standards. The procedure was based on Serdolit Pad-1 resin extraction, enzymatic hydrolysis, and chemical derivatisation prior to instrumental analysis. The mixed derivatives, 3-trimethylsilyl-17-pentafluorophenyldimethylsilyl ether (3-TMS-17-flophemesyl) testosterone and epitestosterone, were found to have excellent analytical properties. The specificity of the derivatisation method exploits a unique feature of ...
[Use of a fast test to detect rotavirus in feces].
Berliner und Munchener tierarztliche Wochenschrift    March 20, 1999   Volume 110, Issue 10 397-400 
Otto P, Elschner M, Schulze P, Prudlo J, Schrader R.The commercially available immunoassay "OnSite Rotavirus" was used for the detection of animal rotaviruses in 113 faecal samples. The sensitivity of the test was 88% and the specificity 96% compared with reference methods (EIA, EM). This test would detect approximately 4.4 x 10(6) to 1.8 x 10(7) virus particles per ml. The presence of virus could be demonstrated in fresh faecal samples from cattle, horses and pigs within a few minutes. The rotaviruses of group A were identified independently of the virus serotype. Further results and additional problems of using this test kit are described.
Measurement of parathyroid hormone in horses.
Equine veterinary journal    December 9, 1998   Volume 30, Issue 6 476-481 doi: 10.1111/j.2042-3306.1998.tb04522.x
Estepa JC, Aguilera-Tejero E, Mayer-Valor R, Almadén Y, Felsenfeld AJ, Rodríguez M.Measurement of parathyroid hormone (PTH) in horses was performed on plasma samples using 2 immunoradiometric assays: a human intact PTH assay and a rat amino-terminal PTH assay. The assays were validated by assessment of their precision, sensitivity and specificity, and also by evaluating PTH changes in the horse in response to variation in blood ionised calcium. Intra- and inter-assay variance, precision and sensitivity were similar for both human and rat assays; however, the rat assay was slightly more precise and sensitive than the human assay. Both assays detected an increase in PTH levels...
Reliability of using results of abdominal fluid analysis to determine treatment and predict lesion type and outcome for horses with colic: 218 cases (1991-1994).
Journal of the American Veterinary Medical Association    October 20, 1998   Volume 213, Issue 7 1012-1015 
Freden GO, Provost PJ, Rand WM.To assess clinical utility of abdominal fluid analysis in predicting outcome, lesion type, and whether medical or surgical treatment is indicated for horses with colic. Methods: Retrospective study. Methods: 218 horses > 1 year old. Methods: Horses were classified on the basis of age, site of lesion, lesion type (nonstrangulating vs strangulating), type of treatment (medical vs surgical), and outcome (survival vs nonsurvival). Sensitivity and specificity of using age and results of abdominal fluid analysis, individually and in combination, to predict lesion type, type of treatment, and outc...
Progesterone determination in equine plasma using different immunoassays.
Acta veterinaria Hungarica    August 26, 1998   Volume 46, Issue 4 501-513 
Nagy P, Solti L, Kulcsár M, Reiczigel J, Huszenicza G, Abaváry K, Wölfling A.Several assay systems (3H radioimmunoassay (RIA) with and without extraction; microplate enzyme-linked immunoassay (ELISA); qualitative ELISA (tube test)] were used to measure plasma progesterone concentration in mare plasma. The direct RIA showed a close correlation (R = 0.94) with the extraction RIA. The direct RIA and the microplate ELISA were compared in two different studies. In the first study 1155 samples of postpartum mares were used for progesterone determination with both assays. The ELISA resulted in more elevated values both in oestrus and dioestrus (0.19+/-0.3 and 2.44+/-3.62 nmol...
Comparison of time-resolved fluoroimmunoassay and immunoenzymometric assay for clenbuterol.
The Analyst    August 1, 1995   Volume 120, Issue 8 2269-2271 doi: 10.1039/an9952002269
Bacigalupo MA, Ius A, Meroni G, Dovis M, Petruzzelli E.A time-resolved fluoroimmunoassay (TR-FIA) for the direct determination of clenbuterol residues in horse urine using a highly specific monoclonal antibody has been compared with an immunoenzymometric assay (IEMA). The sensitivity of both methods was 10 pg; the calibration curve was linear between 10 and 10(5) pg for the TR-FIA and between 10 and 10(4) pg for the IEMA.
Evaluation of the thoraco-laryngeal reflex (‘slap test’) as an aid to the diagnosis of cervical spinal cord and brainstem disease in horses.
Equine veterinary journal    September 1, 1994   Volume 26, Issue 5 358-361 doi: 10.1111/j.2042-3306.1994.tb04403.x
Newton-Clarke MJ, Divers TJ, Delahunta A, Mohammed HO.A study was conducted over a 12 month period to assess the specificity and sensitivity of the 'slap test', using endoscopic evaluation, in the detection of cervical spinal cord and caudal brainstem lesions in horses. Fifteen ataxic horses were subjected to the 'slap test' and subsequently examined post mortem. Twelve out of the 15 had histopathological lesions consistent with their clinical signs. Thirteen horses with no history of neurological dysfunction and no histopathological evidence of cervical spinal cord or brainstem disease were used as controls. The laryngeal adductory responses exh...