Analyze Diet

Topic:Analytical Methods

Analytical methods in equine research encompass a variety of scientific techniques and tools used to study and evaluate different aspects of horse health, performance, and physiology. These methods help advance our understanding of equine biology, diagnosing conditions, and improving management practices. Common analytical methods include molecular techniques like PCR and ELISA for detecting pathogens and measuring biomarkers, imaging technologies such as ultrasound and MRI for assessing musculoskeletal health, and statistical models for analyzing genetic data and performance metrics. This page compiles peer-reviewed research studies and scholarly articles that explore the development, application, and impact of various analytical methods in equine science.
The analysis of pergolide residues in horse plasma by LC with fluorescence detection.
Journal of AOAC International    March 22, 2014   Volume 96, Issue 6 1487-1493 doi: 10.5740/jaoacint.12-282
Doran G, Hughes K, Rendle D, Edwards S.Pergolide is used to treat pituitary pars intermedia dysfunction (equine Cushing's Disease), a neurodegenerative condition associated with loss of dopaminergic inhibition of the pituitary in horses. After oral administration, only low concentrations of the drug are achieved in plasma, making drug detection and quantification difficult. While direct analysis of plasma using sensitive MS/MS techniques is possible, dirty plasma samples and mobile phase buffers can cause instrumentation to become rapidly incapacitated. A method using LC with fluorescence detection was developed for pergolide analy...
A comparative study of free oligosaccharides in the milk of domestic animals.
The British journal of nutrition    March 19, 2014   Volume 111, Issue 7 1313-1328 doi: 10.1017/S0007114513003772
Albrecht S, Lane JA, Mariño K, Al Busadah KA, Carrington SD, Hickey RM, Rudd PM.The present study was conducted to obtain a comprehensive overview of oligosaccharides present in the milk of a variety of important domestic animals including cows, goats, sheep, pigs, horses and dromedary camels. Using an analytical workflow that included ultra-performance liquid chromatography-hydrophilic interaction liquid chromatography with fluorescence detection coupled to quadrupole time-of-flight MS, detailed oligosaccharide libraries were established. The partial or full characterisation of the neutral/fucosylated, phosphorylated and sialylated structures was facilitated by sequencin...
Analytical performance of a dry chemistry analyzer designed for in-clinic use.
Veterinary clinical pathology    March 3, 2014   Volume 43, Issue 2 206-217 doi: 10.1111/vcp.12122
Flatland B, Breickner LC, Fry MM.The Heska Dri-Chem 4000 uses dry slide technology to evaluate serum or plasma. No previous independent performance evaluation is published to the authors' knowledge. Objective: The objectives were to (1) characterize analytical performance of a Dri-Chem 4000 by measuring precision and bias, (2) compare analytical performance of that Dri-Chem 4000 unit with a predetermined quality requirement, and (3) determine whether statistical QC of the Dri-Chem 4000 is possible using the 13s control rule. Methods: Sixteen analytes were measured using plasma from dogs, cats, and horses. Coefficient of varia...
Factors influencing total carbon dioxide concentrations in plasma of thoroughbred and standardbred racehorses.
Drug testing and analysis    February 24, 2014   Volume 6, Issue 9 936-943 doi: 10.1002/dta.1600
Sutton GJ, Cawley A, Murphy C, Lau ML, Hibbert DB.Horse racing authorities impose a limit on the concentration of plasma 'total carbon dioxide' (TCO2), typically 36 mM with action taken above 37 mM, as measured by an electrochemical gas analyzer. It is of interest to understand the distribution of TCO2 in a 'normal' population of racehorses and determine probabilities of members of this population exceeding these current regulatory and action limits. TCO2 levels in equine plasma samples have been modelled for 12 months (2011-2012) of thoroughbred (3076 measurements) and standardbred (3788 measurements) data in Australia. The two populations h...
Development and validation of a gas chromatography-flame ionization detection method for quantifying sucrose in equine serum. Hewetson M, Aaltonen K, Tulamo RM, Sankari S.A simple and accurate method for quantifying sucrose in equine serum that can be applied to sucrose permeability testing in the horse was developed and validated using gas chromatography with flame ionization detection. The assay provided an acceptable degree of linearity, accuracy, and precision at concentrations of sucrose as low as 2.34 μmol/l and as high as 20.45 μmol/l. Percentage recovery of sucrose from serum ranged from 89% to 102%; repeatability and intermediate precision (relative standard deviation) ranged from 3.6% to 6.7% and 4.1% to 9.3%, respectively. The limit of detection wa...
Determination of pergolide in horse plasma by UPLC-MS/MS for pharmacokinetic applications.
Journal of pharmaceutical and biomedical analysis    January 24, 2014   Volume 94 54-57 doi: 10.1016/j.jpba.2014.01.016
Jacobson GA, Pirie A, Edwards S, Hughes KJ, Rendle DI, Davies NW.Pergolide, an ergot-derived dopamine D2 receptor agonist, is used extensively as an orally administered treatment for pituitary pars intermedia dysfunction (PPID) in horses. One of the barriers associated with pergolide determinations in plasma for pharmacokinetic applications has been the technically demanding requirement for sensitivity. The objective of our work was to develop a simple assay for the determination of pergolide in plasma and demonstrate its potential application in the study of pergolide pharmacokinetics (PK) in horses. A UPLC-MS/MS assay was developed with a simple sample pr...
Synthesis, purification, and chemical characterization of 20-dihydro-6-methylprednisone, an isomeric metabolite of methylprednisolone in the horse, for use as an analytical standard.
Drug testing and analysis    January 21, 2014   Volume 6, Issue 3 303-307 doi: 10.1002/dta.1599
Eisenberg R, Kudrimoti S, Hughes CG, Maylin GA, Tobin T.No abstract available
Doping control analyses in horseracing: a clinician’s guide.
Veterinary journal (London, England : 1997)    January 17, 2014   Volume 200, Issue 1 8-16 doi: 10.1016/j.tvjl.2014.01.006
Wong JK, Wan TS.Doping(1) in sports is highly detrimental, not only to the athletes involved but to the sport itself as well as to the confidence of the spectators and other participants. To protect the integrity of any sport, there must be in place an effective doping control program. In human sports, a 'top-down' and generally unified approach is taken where the rules and regulations against doping for the majority of elite sport events held in any country are governed by the World Anti-Doping Agency (WADA). However, in horseracing, there is no single organisation regulating this form of equestrian sport; i...
Systematic evaluation of evidence on veterinary viscoelastic testing part 1: System comparability.
Journal of veterinary emergency and critical care (San Antonio, Tex. : 2001)    January 14, 2014   Volume 24, Issue 1 23-29 doi: 10.1111/vec.12143
McMichael M, Goggs R, Smith S, Wagg C, Warman S, Wiinberg B.To systematically examine the evidence on system comparability between the thromboelastography and the rotational thromboelastometry viscoelastic point-of-care instruments and to identify knowledge gaps. Methods: Standardized, systematic evaluation of the literature, categorization of relevant articles according to level of evidence and quality, and development of consensus on conclusions for application of the concepts to clinical practice. Methods: Academic and referral veterinary medical centers. Results: Medline via PubMed, CAB abstracts, and Google Scholar were searched. A total of 8 rele...
Troponin assays in the assessment of the equine myocardium.
Equine veterinary journal    January 7, 2014   Volume 46, Issue 3 270-275 doi: 10.1111/evj.12209
Rossi TM, Pyle WG, Maxie MG, Pearl DL, Physick-Sheard PW.In 2000, troponin assays were adopted as the test of choice for detection of myocardial injury in man. This decision was made after extensive testing and followed a 60 year search for a biomarker of myocardial damage with sufficient analytical sensitivity and specificity. This has led to proliferation of assays for use in human medicine, each requiring extensive testing and validation before it could be made available on the open market for human use. The search for ever-more analytically sensitive assays and for a standard reference material continues. The adoption of troponin testing in vete...
Detection and pharmacokinetics of three formulations of firocoxib following multiple administrations to horses.
Equine veterinary journal    January 7, 2014   Volume 46, Issue 6 734-738 doi: 10.1111/evj.12211
Knych HK, Stanley SD, Arthur RM, Mitchell MM.The use of firocoxib in horses and its ability to affect performance and potential to allow a horse to compete when it otherwise should not, necessitates establishing appropriate withdrawal time guidelines prior to performance. Objective: To describe plasma concentrations and characterise the pharmacokinetics of 3 firocoxib formulations following multiple administrations of the label dose, with respect to recommended plasma thresholds for performance horses. Methods: Balanced 3-way crossover prospective study. Methods: Nine healthy mature horses were administered firocoxib injectable solution ...
Sensitive hydrophilic interaction liquid chromatography/tandem mass spectrometry method for rapid detection, quantification and confirmation of cathinone-derived designer drugs for doping control in equine plasma.
Rapid communications in mass spectrometry : RCM    December 18, 2013   Volume 28, Issue 2 217-229 doi: 10.1002/rcm.6778
Li X, Uboh CE, Soma LR, Liu Y, Guan F, Aurand CR, Bell DS, You Y, Chen J, Maylin GA.Cathinone derivatives are new amphetamine-like stimulants that can evade detection when presently available methods are used for doping control. To prevent misuse of these banned substances in racehorses, development of a liquid chromatography/tandem mass spectrometry (LC/MS/MS) method became the impetus for undertaking this study. Methods: Analytes were recovered via liquid-liquid extraction using methyl tert-butyl ether. Analyte separation was achieved on a hydrophilic interaction column using liquid chromatography and mass analysis was performed on a QTRAP mass spectrometer in positive elec...
Comparison of paired serum and lithium heparin plasma samples for the measurement of serum amyloid A in horses using an automated turbidimetric immunoassay.
Veterinary journal (London, England : 1997)    December 11, 2013   Volume 199, Issue 3 457-460 doi: 10.1016/j.tvjl.2013.12.007
Howard J, Graubner C.This study aimed to evaluate whether equine serum amyloid A (SAA) concentrations could be reliably measured in plasma with a turbidimetric immunoassay previously validated for equine SAA concentrations in serum. Paired serum and lithium-heparin samples obtained from 40 horses were evaluated. No difference was found in SAA concentrations between serum and plasma using a paired t test (P=0.48). The correlation between paired samples was 0.97 (Spearman's rank P<0.0001; 95% confidence interval 0.95-0.99). Passing-Bablok regression analyses revealed no differences between paired samples. Bland-A...
Detection and quantification of dermorphin and selected analogs in equine urine.
Bioanalysis    December 11, 2013   Volume 5, Issue 24 2995-3007 doi: 10.4155/bio.13.281
Richards SL, Cawley AT, Raftery MJ.Dermorphin, a hepta-peptide with potent analgesic properties, is classified as a doping agent in equine racing. Since its discovery, a number of biologically active structural analogs have been synthesized and made commercially available so there is a need for reliable methods of detection. Results: A sensitive detection method was developed for dermorphin and six analogs in equine urine. Peptide enrichment was achieved using weak cation exchange with subsequent separation and detection by nano-UHPLC-MS/MS. Method validation parameters included: specificity, linearity (5-10000 pg/ml), recovery...
ASVCP guidelines: allowable total error guidelines for biochemistry.
Veterinary clinical pathology    December 11, 2013   Volume 42, Issue 4 424-436 doi: 10.1111/vcp.12101
Harr KE, Flatland B, Nabity M, Freeman KP.As all laboratory equipment ages and contains components that may degrade with time, initial and periodically scheduled performance assessment is required to verify accurate and precise results over the life of the instrument. As veterinary patients may present to general practitioners and then to referral hospitals (both of which may each perform in-clinic laboratory analyses using different instruments), and given that general practitioners may send samples to reference laboratories, there is a need for comparability of results across instruments and methods. Allowable total error (TEa ) is ...
A high throughput screen for 17 Dermorphin peptides in equine and human urine and equine plasma.
Drug testing and analysis    November 20, 2013   Volume 6, Issue 9 909-921 doi: 10.1002/dta.1585
Steel R, Timms M, Levina V, Vine J.The Dermorphins are a family of peptides that act as potent agonists of the opioid μ receptor. Originally identified as a seven amino acid peptide on the skin of the South American Phyllomedusa frog, peptide chemists have since developed a large number of Dermorphin variants, many with superior opioid activity to the original peptide. Dermorphins are unique among the peptide opioid agonists as they appear to have a limited ability to cross the blood brain barrier, producing effects on both the central and peripheral nervous systems. It is this ability of Dermorphins to provide central anaesth...
Validation of an improved competitive enzyme-linked immunosorbent assay to detect Equine arteritis virus antibody. Chung C, Wilson C, Timoney P, Balasuriya U, Adams E, Adams DS, Evermann JF, Clavijo A, Shuck K, Rodgers S, Lee SS, McGuire TC.The objective of the present study was to validate a previously described competitive enzyme-linked immunosorbent assay (cELISA) to detect antibody to Equine arteritis virus (EAV) based on GP5-specific nonneutralizing monoclonal antibody (mAb) 17B7(9) using the World Organization for Animal Health (OIE)-recommended protocol, which includes the following 5 in-house analyses. 1) The assay was calibrated with the OIE-designated reference serum panel for EAV; 2) repeatability was evaluated within and between assay runs; 3) analytical specificity was evaluated using sera specific to related viruses...
Analytic validation and comparison of three commercial immunoassays for measurement of plasma atrial/A-type natriuretic peptide concentration in horses.
Research in veterinary science    November 7, 2013   Volume 96, Issue 1 180-186 doi: 10.1016/j.rvsc.2013.10.011
Trachsel DS, Schwarzwald CC, Grenacher B, Weishaupt MA.Measurement of atrial/A-type natriuretic peptide (ANP) concentrations may be of use for assessment of cardiac disease, and reliable data on the analytic performance of available assays are needed. To assess the suitability for clinical use of commercially available ANP assays, intra-assay and inter-assay coefficient of variation and dilution parallelism were calculated for three immunoassays (RIAPen, RIAPhoen, and an ELISAPen) using blood samples from healthy and diseased horses to cover a wide range of ANP concentrations. Further, agreement between assays was assessed using linear regression ...
A generic screening methodology for horse doping control by LC-TOF-MS, GC-HRMS and GC-MS.
Journal of chromatography. B, Analytical technologies in the biomedical and life sciences    October 16, 2013   Volume 941 69-80 doi: 10.1016/j.jchromb.2013.10.008
In the present study a general screening protocol was developed to detect prohibited substances and metabolites for doping control purposes in equine sports. It was based on the establishment of a unified sample preparation and on the combined implementation of liquid and gas chromatographic MS analysis. The sample pretreatment began with two parallel procedures: enzymatic hydrolysis of sulfate and glucuronide conjugates, and methanolysis of the 17β-sulfate steroid conjugates. The extracts were treated for LC-TOF-MS, GC-HRMS and GC-MS assays. The majority of the prohibited substances were ide...
Comparison of components of biological variation between 3 equine thromboelastography assays.
Veterinary clinical pathology    September 18, 2013   Volume 42, Issue 4 443-450 doi: 10.1111/vcp.12079
Hyldahl Laursen S, Andersen PH, Kjelgaard-Hansen M, Wiinberg B.There is a paucity of information about the analytical performance of thromboelastography (TEG) in horses, specifically concerning components of variation among different analytical methods. Such data may be obtained by nested analysis of repetitive standardized sampling of healthy individuals. Objective: The objectives were (1) to assess the relative susceptibility to sources of preanalytical variation in a highly standardized setting, (2) to directly compare and evaluate the observed analytical variation, and (3) to assess the applicability of population-based reference intervals. Methods: B...
Biological application of laser induced breakdown spectroscopy technique for determination of trace elements in hair.
Talanta    September 7, 2013   Volume 117 176-183 doi: 10.1016/j.talanta.2013.08.043
Emara EM, Imam H, Hassan MA, Elnaby SH.Analysis of trace elements in mammalian hair has the potential to reveal retrospective information about an individual's nutritional status and exposure. As trace elements are incorporated into the hair during the growth process, longitudinal segments of the hair may reflect the body burden during growth. Using LIBS technique, Na, K, Ca, Mg, Si, Fe, Pb and Zn were detected in a single strand of horse hair. The results obtained through LIBS technique on hair samples were compared with the traditional technique (AAS) on digested acidified solution of the same samples. The effects of the experime...
Quantitation of fluphenazine in equine serum following fluphenazine decanoate administration.
Journal of analytical toxicology    August 28, 2013   Volume 37, Issue 8 594-599 doi: 10.1093/jat/bkt073
Costello S, Heffron B, Taddei L, Benoit M, Hurt L, Simpson L, Bishop J, Folker-Calderon D, Negrusz A.Fluphenazine, a potent antipsychotic used to treat schizophrenia in humans, is used in racehorses as a performance-enhancing drug, and for that reason it has been banned by the Association of Racing Commissioners International. A liquid chromatography-tandem mass spectrometry method for detecting and quantitating fluphenazine in equine serum was developed and validated. The method was then employed to quantitate fluphenazine in serum samples collected from three study horses after intramuscular injection of fluphenazine decanoate. Stability testing showed that fluphenazine is stable in unextra...
Quantification of several acidic drugs in equine serum using LC-MS-MS.
Journal of analytical toxicology    August 27, 2013   Volume 37, Issue 8 600-604 doi: 10.1093/jat/bkt069
Heffron B, Taddei L, Benoit M, Negrusz A.The use of nonsteroidal antiinflammatory drugs in racehorses is allowed under most jurisdictions. Furosemide is administered to treat exercise-induced pulmonary hemorrhage. To help distinguish between therapeutic and illegal uses, racing regulatory bodies have set thresholds in serum for several drugs. The method for the simultaneous detection and quantification of furosemide, flunixin, ketoprofen, phenylbutazone and oxyphenbutazone using 500 µL of serum, and liquid extraction using diethyl ether : hexanes : dichloromethane followed by liquid chromatography tandem mass spectrometry quantitati...
Detection and elimination profile of cathinone in equine after norephedrine (Propalin®) administration using a validated liquid chromatography-tandem mass spectrometry method.
Analytical and bioanalytical chemistry    August 17, 2013   Volume 405, Issue 30 9711-9722 doi: 10.1007/s00216-013-7073-0
Yi R, Zhao S, Lam G, Sandhu J, Loganathan D, Morrissey B.Cathinone is the principal psychostimulant present in the leaves of khat shrub, which are widely used in East Africa and the Arab peninsula as an amphetamine-like stimulant. Cathinone readily undergoes metabolism in vivo to form less potent cathine and norephedrine as the metabolites. However, the presence of cathine and norephedrine in biological fluids cannot be used as an indicator of cathinone administration. The metabolism of pseudoephedrine and ephedrine, commonly used in cold and allergy medications, also produces cathine and norephedrine, respectively, as the metabolites. Besides, cath...
Monitoring the endogenous steroid profile disruption in urine and blood upon nandrolone administration: An efficient and innovative strategy to screen for nandrolone abuse in entire male horses.
Drug testing and analysis    August 15, 2013   Volume 6, Issue 4 376-388 doi: 10.1002/dta.1520
Kaabia Z, Dervilly-Pinel G, Popot MA, Bailly-Chouriberry L, Plou P, Bonnaire Y, Le Bizec B.Nandrolone (17β-hydroxy-4-estren-3-one) is amongst the most misused endogenous steroid hormones in entire male horses. The detection of such a substance is challenging with regard to its endogenous presence. The current international threshold level for nandrolone misuse is based on the urinary concentration ratio of 5α-estrane-3β,17α-diol (EAD) to 5(10)-estrene-3β,17α-diol (EED). This ratio, however, can be influenced by a number of factors due to existing intra- and inter-variability standing, respectively, for the variation occurring in endogenous steroids concentration levels in a si...
Comparison of two analyzers for measurement of plasma total carbon dioxide concentration in horses.
American journal of veterinary research    July 25, 2013   Volume 74, Issue 8 1091-1102 doi: 10.2460/ajvr.74.8.1091
Constable PD, Tinkler SH, Couëtil LL.To determine the degree of agreement between 2 analyzers for measurement of total CO₂ concentration (ctCO₂) in equine plasma. Methods: 6 healthy untrained horses, 6 trained Standardbreds undergoing a simulated race protocol, and 135 trained Standardbreds at a racetrack. Methods: Jugular venous blood samples were obtained from all horses. Two analyzers (commonly used analyzer A and less expensive analyzer B) were used to measure plasma ctCO₂ in each sample. Validation of both analyzers was conducted in accordance with guidelines established by the Clinical and Laboratory Standards Institu...
Functional limits of agreement applied as a novel method comparison tool for accuracy and precision of inertial measurement unit derived displacement of the distal limb in horses.
Journal of biomechanics    July 23, 2013   Volume 46, Issue 13 2320-2325 doi: 10.1016/j.jbiomech.2013.06.004
Olsen E, Pfau T, Ritz C.Over ground motion analysis in horses is limited by a small number of strides and restraints of the indoor gait laboratory. Inertial measurement units (IMUs) are transforming the knowledge of human motion and objective clinical assessment through the opportunity to obtain clinically relevant data under various conditions. When using IMUs on the limbs of horses to determine local position estimates, conditions with high dynamic range of both accelerations and rotational velocities prove particularly challenging. Here we apply traditional method agreement and suggest a novel method of functional...
Investigations into the feasibility of routine ultra high performance liquid chromatography-tandem mass spectrometry analysis of equine hair samples for detecting the misuse of anabolic steroids, anabolic steroid esters and related compounds.
Analytica chimica acta    June 10, 2013   Volume 787 163-172 doi: 10.1016/j.aca.2013.05.058
Gray BP, Viljanto M, Bright J, Pearce C, Maynard S.The detection of the abuse of anabolic steroids in equine sport is complicated by the endogenous nature of some of the abused steroids, such as testosterone and nandrolone. These steroids are commonly administered as intramuscular injections of esterified forms of the steroid, which prolongs their effects and improves bioavailability over oral dosing. The successful detection of an intact anabolic steroid ester therefore provides unequivocal proof of an illegal administration, as esterified forms are not found endogenously. Detection of intact anabolic steroid esters is possible in plasma samp...
Fast and sensitive analysis of dermorphin and HYP6-dermorphin in equine plasma using liquid chromatography tandem mass spectrometry.
Drug testing and analysis    May 29, 2013   Volume 6, Issue 4 342-349 doi: 10.1002/dta.1487
Wang CC, Hartmann-Fischbach P, Krueger TR, Wells TL, Feineman AR, Compton JC.Dermorphin and HYP(6) -dermorphin are hepta-peptides and natural opioids originally isolated from the skin of South American frogs. They are more potent than morphine but less likely to produce drug tolerance and addiction. These properties make them ideal candidates for the doping of racehorses to enhance performance during competition. Dermorphin was recently classified as a Class I drug by Racing Commissioners International (RCI), indicating that it is a banned substance in equine athletes. To enforce this ban, a fast and sensitive method was developed for dermorphin and HYP(6)-dermorphin a...
Furry pet allergens, fungal DNA and microbial volatile organic compounds (MVOCs) in the commercial aircraft cabin environment.
Environmental science. Processes & impacts    May 7, 2013   Volume 15, Issue 6 1228-1234 doi: 10.1039/c3em30928b
Fu X, Lindgren T, Guo M, Cai GH, Lundgren H, Norbäck D.There has been concern about the cabin environment in commercial aircraft. We measured cat, dog and horse allergens and fungal DNA in cabin dust and microbial volatile organic compounds (MVOCs) in cabin air. Samples were collected from two European airline companies, one with cabins having textile seats (TSC) and the other with cabins having leather seats (LSC), 9 airplanes from each company. Dust was vacuumed from seats and floors in the flight deck and different parts of the cabin. Cat (Fel d1), dog (Can f1) and horse allergens (Equ cx) were analyzed by ELISA. Five sequences of fungal DNA we...
1 23 24 25 26 27 53