Analyze Diet

Topic:Blood Vessels

Blood vessels in horses are integral components of the circulatory system, responsible for the transportation of blood throughout the body. They consist of arteries, veins, and capillaries, each serving distinct functions in maintaining circulatory efficiency. Arteries carry oxygen-rich blood away from the heart to various tissues, while veins return deoxygenated blood back to the heart. Capillaries facilitate the exchange of nutrients, gases, and waste products between blood and tissues. The structure and function of equine blood vessels are subjects of study due to their role in health and disease, including conditions such as laminitis and equine metabolic syndrome. This page compiles peer-reviewed research studies and scholarly articles that explore the anatomy, physiology, and pathophysiology of blood vessels in horses.
Clenbuterol administration does not attenuate the exercise-induced pulmonary arterial, capillary or venous hypertension in strenuously exercising Thoroughbred horses.
Equine veterinary journal    November 28, 2000   Volume 32, Issue 6 546-550 doi: 10.2746/042516400777584604
Manohar M, Goetz TE, Rothenbaum P, Humphrey S.The present study was carried out to ascertain whether beta2-adrenergic receptor stimulation with clenbuterol would attenuate the pulmonary arterial, capillary and venous hypertension in horses performing high-intensity exercise and, in turn, modify the occurrence of exercise-induced pulmonary haemorrhage (EIPH). Experiments were carried out on 6 healthy, sound, exercise-trained Thoroughbred horses. All horses were studied in the control (no medications) and the clenbuterol (0.8 pg/kg bwt, i.v.) treatments. The sequence of these treatments was randomised for every horse, and 7 days were allowe...
Effect of a 30-minute infusion of dobutamine hydrochloride on hind limb blood flow and hemodynamics in halothane-anesthetized horses.
American journal of veterinary research    October 20, 2000   Volume 61, Issue 10 1282-1288 doi: 10.2460/ajvr.2000.61.1282
Raisis AL, Young LE, Blissitt KJ, Walsh K, Meire HB, Taylor PM, Lekeux P.To evaluate the hemodynamic effects of dobutamine hydrochloride (0.5 microg/kg of body weight/min) in halothane-anesthetized horses. Methods: 6 adult Thoroughbred horses. Methods: Anesthesia was induced by use of romifidine (100 microg/kg) and ketamine (2.2 mg/kg), IV. Anesthesia was maintained by halothane (end-tidal concentration 0.9 to 1.0%). Aortic, left ventricular, and right atrial pressures were measured, using catheter-mounted strain gauge transducers. Cardiac output (CO), velocity time integral, maximal aortic blood flow velocity and acceleration, and left ventricular preejection peri...
Haemodynamic response to exercise in Standardbred trotters with red cell hypervolaemia.
Equine veterinary journal    October 19, 2000   Volume 32, Issue 5 426-431 doi: 10.2746/042516400777591057
Funkquist P, Nyman G, Persson SG.In order to evaluate the haemodynamic response to exercise in Standardbred trotters with red cell hypervolaemia (RCHV), 12 trotters with RCHV were compared with 9 normovolaemic (NV) trotters. Haemodynamic data were recorded during exercise at 4 different speeds on a treadmill. Oxygen uptake was determined with an open bias flow system. Pulmonary artery pressure (PAP), systemic artery pressure (SAP), heart rate, packed cell volume (PCV) and plasma lactate and haemoglobin ([Hb]) concentrations were measured. Arteriovenous O2 content difference, cardiac output, stroke volume, pulmonary vascular r...
The case for measuring plasma colloid osmotic pressure.
Journal of veterinary internal medicine    September 30, 2000   Volume 14, Issue 5 473-474 
Stewart RH.No abstract available
Effect of a static magnetic field on blood flow to the metacarpus in horses.
Journal of the American Veterinary Medical Association    September 21, 2000   Volume 217, Issue 6 874-877 doi: 10.2460/javma.2000.217.874
Steyn PF, Ramey DW, Kirschvink J, Uhrig J.To determine the effect of a static magnetic field on relative blood flow to the metacarpus of horses. Methods: Randomized controlled clinical trial. Methods: 6 healthy adult horses. Methods: Red blood cells were radiolabeled in vivo by administration of technetium Tc 99m (pyro- and trimeta-) phosphates, and scintigraphic images were obtained 30 minutes later. A magnetic wrap that emitted a static magnetic field was applied to 1 metacarpus and a control wrap was applied to the contralateral metacarpus. Forty-eight hours later, the wraps were removed, and scintigraphy was repeated. Relative per...
Evidence of histamine receptor function in isolated horse penile dorsal arteries.
Life sciences    September 6, 2000   Volume 67, Issue 11 1355-1368 doi: 10.1016/s0024-3205(00)00724-4
Martínez AC, Rivera L, Raposo R, García-Sacristán A, Benedito S.The effect of histamine (10(-9)-10(-3) M) on horse penile dorsal artery was evaluated. Precontracted vessels showed a biphasic response (relaxation-contraction) to histamine, while at basal tone, histamine only induced a contractile effect. The H1 receptor agonist, 2-pyridylethylamine (PEA) (10(-9)-10(-3) M), induced concentration-dependent relaxation in precontracted rings and provoked vasoconstriction at basal tone. Mepyramine (10(-9)-10(8) M), an H1 receptor antagonist, competitively antagonized the relaxant response to histamine (pA2 = 9.7) and PEA (pA2 = 9.2). At basal tone, mepyramine (1...
A comparison of the haemodynamic effects of isoflurane and halothane anaesthesia in horses.
Equine veterinary journal    August 22, 2000   Volume 32, Issue 4 318-326 doi: 10.2746/042516400777032282
Raisis AL, Young LE, Blissitt KJ, Brearley JC, Meire HB, Taylor PM, Lekeux P.The purpose of this study was to compare the haemodynamic effects of equipotent isoflurane and halothane anaesthesia. Six adult horses were investigated on two separate occasions at least 4 weeks apart. On both occasions anaesthesia was induced by ketamine 2.2 mg/kg bwt given 5 min after i.v. administration 100 microg/kg bwt romifidine. Anaesthesia was maintained either by halothane or isoflurane (end-tidal concentrations 0.9-1.0% and 1.3-1.4%, respectively). Horses were ventilated by intermittent positive pressure to maintain PaCO2 between 40-50 mmHg. Haemodynamic variables were measured usin...
Laminar microvascular flow, measured by means of laser Doppler flowmetry, during the prodromal stages of black walnut-induced laminitis in horses.
American journal of veterinary research    August 22, 2000   Volume 61, Issue 8 862-868 doi: 10.2460/ajvr.2000.61.862
Adair HS, Goble DO, Schmidhammer JL, Shires GM.To measure changes in laminar microvascular blood flow (LMBF) over time in healthy horses and horses in the prodromal stage of black walnut-induced laminitis and to determine the effects of glyceryl trinitrate application on LMBF in horses with acute laminitis. Methods: 10 healthy adult horses. Methods: Laser Doppler flowmetry was used to measure LMBF Baseline measurements were obtained, horses were given deionized water via a nasogastric tube, and measurements were obtained hourly for 12 hours. Twenty-four hours later, baseline measurements were again obtained, and horses were given black wal...
A unique exocelom-like space during early pregnancy in the horse.
Placenta    August 15, 2000   Volume 21, Issue 5-6 575-583 doi: 10.1053/plac.2000.0508
Enders AC, Liu IK.The free allantois and allantochorion of conceptuses from 17 mares between 20 and 90 days of gestation were examined to determine the manner in which the associated mesodermal derivatives differentiated. It was found that a robust basement membrane developed under the allantoic endoderm, and that this basement membrane was partially isolated from the vascular layer of the allantois by a mesothelial layer and an exocelom-like space. The exocelom-like space persisted until approximately the stage of villous formation, and remnants of the space persisted over larger allantoic vessels even later. ...
Repeatability of Doppler ultrasound measurements of hindlimb blood flow in halothane anaesthetised horses.
Equine veterinary journal    June 3, 2000   Volume 32, Issue 3 239-246 doi: 10.2746/042516400776563662
Raisis AL, Young LE, Meire H, Walsh K, Taylor PM, Lekeux P.The purpose of this study was to determine the repeatability of femoral blood flow recorded using Doppler ultrasound in anaesthetised horses. Doppler ultrasound of the femoral artery and vein was performed in 6 horses anaesthetised with halothane and positioned in left lateral recumbency. Velocity spectra, recorded using low pulse repetition frequency, were used to calculate time-averaged mean velocity (TAV), velocity of component a (TaVa), velocity of component b (TaVb), volumetric flow, early diastolic deceleration slope (EDDS) and pulsatility index (PI). Within-patient variability was deter...
Laparoscopic intra-abdominal ligation of the testicular artery following castration in a horse.
Journal of the American Veterinary Medical Association    May 29, 2000   Volume 216, Issue 10 1596-1569 doi: 10.2460/javma.2000.216.1596
Trumble TN, Ingle-Fehr J, Hendrickson DA.A 364-kg (800-lb) 1-year-old mixed-breed horse was admitted for treatment of uncontrolled bleeding after castration. Multiple attempts to ligate the testicular artery through the scrotal incisions prior to referral had been unsuccessful. Because of the owner's concerns about cost, an attempt was made to control the bleeding by applying pressure to the inguinal region and administering formalin IV. However, hemorrhage continued. A decision was made to use laparoscopy to ligate the testicular artery. The horse was anesthetized and positioned in dorsal recumbency, and a routine ventral laparoscop...
Duplex-ultrasonographic evaluation of the common carotid artery in the resting, sedated and anesthetized horse. Schmucker N, Schatzmann U, Budde K, Gundel M, Jäggin CE, Meier H.The aim of this study was to determine the blood flow in the carotid artery during halothane anaesthesia by means of duplex-sonography. Seventeen warm blood horses were evaluated in dorsal and lateral recumbency and the results were compared with the values of the same horses resting and under sedation. The cross sectional area of the vessels, the time-averaged maximal blood velocity, time-averaged maximal blood flow and the resistance index were determined and the flow profile was evaluated. During halothane anesthesia the total blood flow shows a significant increase which is not dependent o...
Variability of Doppler ultrasound measurements of hindlimb blood flow in conscious horses.
Equine veterinary journal    April 1, 2000   Volume 32, Issue 2 125-132 doi: 10.2746/042516400777591561
Raisis AL, Young LE, Meire HB, Taylor PM, Walsh K, Lekeux P.Ultrasonography of the left and right femoral artery and vein was performed in 5 conscious horses. Velocity waveforms, recorded using low pulse repetition frequency, were used to calculate time-averaged mean velocity (TAV), velocity of component a (TaVa), velocity of component b (TaVb) and volumetric flow. Waveform analysis included calculation of early diastolic deceleration slope (EDDS) and pulsatility index (PI) and subjective description of the waveform. Measurements were recorded at monthly intervals for 6 months. The repeated measurements were used to determine the within-horse variation...
Transrectal color Doppler sonography of the A. uterina in cyclic mares.
Theriogenology    March 25, 2000   Volume 49, Issue 8 1483-1488 doi: 10.1016/s0093-691x(98)00094-6
Bollwein H, Maierl J, Mayer R, Stolla R.Color Doppler ultrasound was used transrectally in 6 mares to locate both the left and right Aa. uterinae and to obtain flow velocity waveforms at defined times (Days 0, 5, 10, 15 and 20) during 4 estrous cycles. Blood flow reflected by the resistance index (RI) was determined for both arteries on 120 occasions. As there was no significant difference and a high correlation in the RI values between the left and right arteries (paired Student's t-test, correlation coefficient r > 0.94; P < 0.05), the average RI value was used for subsequent analyses. There were correlations between RI valu...
Detachable latex balloon occlusion of an internal carotid artery with an aberrant branch in a horse with guttural pouch (auditory tube diverticulum) mycosis.
Journal of the American Veterinary Medical Association    March 15, 2000   Volume 216, Issue 6 888-865 doi: 10.2460/javma.2000.216.888
Cheramie HS, Pleasant RS, Dabareiner RM, Carolan RO.An aberrant branch of the internal carotid artery was detected by angiography in a horse with guttural pouch (auditory tube diverticulum) mycosis after the distal portion of the artery had been occluded by use of a detachable latex balloon. A second balloon was placed to eliminate retrograde hemorrhage from the aberrant branch. The horse recovered and returned to its previous activity. Vascular anomalies of the internal carotid artery my be more common than expected, and have resulted in fatal complications during and after surgical treatment in guttural pouch mycosis. Intraoperative identific...
Digital angiography of the feet of horses.
American journal of veterinary research    March 14, 2000   Volume 61, Issue 3 255-259 doi: 10.2460/ajvr.2000.61.255
Rosenstein DS, Bowker RM, Bartlett PC.To describe the vascular anatomy of the palmar digital artery and its major branches in the equine foot and to quantify the diameter of these vessels by use of digital angiograms. Sample Population-6 thoracic limbs obtained from 6 horses. Methods: Distal portions of each limb were perfused with aerated Krebs-Henseleit solution. Digital angiograms were acquired in standing and lateral recumbent positions, following an intra-arterial injection of iopamidol. Select vessels were measured on radiographic views, and values were corrected for magnification. Results: The palmar digital artery tapered ...
Doppler ultrasonography and single-fiber laser Doppler flowmetry for measurement of hind limb blood flow in anesthetized horses.
American journal of veterinary research    March 14, 2000   Volume 61, Issue 3 286-290 doi: 10.2460/ajvr.2000.61.286
Raisis AL, Young LE, Taylor PM, Walsh KP, Lekeux P.To use Doppler ultrasonography and single-fiber laser Doppler flowmetry (LDF) to evaluate blood flow in the dependent and nondependent hind limbs of anesthetized horses and to evaluate changes in femoral arterial blood flow and microvascular skeletal muscle perfusion in response to administration of phenylephrine hydrochloride or dobutamine hydrochloride. Methods: 6 healthy adult horses. Methods: Horses were anesthetized and positioned in left lateral recumbency. Doppler ultrasonography was used to measure velocity and volumetric flow in the femoral vessels. Single-fiber LDF was used to measur...
Doppler ultrasonographic features of thoracic limb arteries in clinically normal horses.
American journal of veterinary research    February 24, 2000   Volume 61, Issue 2 183-190 doi: 10.2460/ajvr.2000.61.183
Cochard T, Toal RL, Saxton AM.To determine blood flow velocities and indices from spectral waveforms obtained by use of Doppler ultrasonography of thoracic limb arteries of horses and to assess interobserver and patient variability associated with the technique. Methods: 9 clinically normal adult horses. Methods: Left thoracic limb arteries of 8 nonsedated horses were examined at 5 sites by use of pulsed-wave Doppler ultrasonography to determine a range of values for peak systolic, end diastolic, and mean velocities and resistive and pulsatility indices. Interobserver and patient variabilities were determined by 2 operator...
High-altitude effects on respiratory gases, acid-base balance and pulmonary artery pressures in equids.
Equine veterinary journal. Supplement    February 5, 2000   Issue 30 71-76 doi: 10.1111/j.2042-3306.1999.tb05192.x
Greene HM, Wickler SJ, Anderson TP, Cogger EA, Lewis CC, Wyle A.Arterial and venous blood were analysed at rest and post exercise for pH, PCO2, and PO2, and bicarbonate ([HCO3-]), base excess (BE), and strong ion difference (SID) were calculated in response to a 10 day sojourn to 3800 m. Pulmonary artery pressures (PAP) were measured at rest. Post exercise samples were restricted to venous blood. The equids (n = 6) experienced a profound hypoxia-hypocapnia and a respiratory alkalosis. PaO2 decreased 42% and PaCO2 41%. PaCO2 increased to 80% of initial values after 8 days at altitude. Arterial [HCO3-] decreased by 34%; however, it returned to normal by Day ...
Pulmonary vascular resistance of horses decreases with moderate exercise and remains unchanged as workload is increased to maximal exercise.
Equine veterinary journal. Supplement    February 5, 2000   Issue 30 117-121 doi: 10.1111/j.2042-3306.1999.tb05200.x
Manohar M, Goetz TE.This study was carried out to examine changes in pulmonary vascular resistance (PVR) induced by moderate and strenuous exercise; the objective being to understand why pulmonary artery blood pressure of exercising horses increases progressively as work intensity increases. Pulmonary arterial and wedge pressures (referenced at the point of the left shoulder) were determined simultaneously with cardiac output in 2 groups of healthy, sound, exercise-trained horses. Horses in Group 1 (n = 8) were studied at rest and during exercise performed at 8 and 13 m/s; the latter workload eliciting maximal he...
Pulmonary capillary pressure in horses undergoing alteration of pleural pressure by imposition of various upper airway resistive loads.
Equine veterinary journal. Supplement    February 5, 2000   Issue 30 27-33 doi: 10.1111/j.2042-3306.1999.tb05183.x
Ducharme NG, Hackett RP, Gleed RD, Ainsworth DM, Erb HN, Mitchell LM, Soderholm LV.We hypothesized that changes in pleural pressure induced by resistive breathing would affect transmural pulmonary artery, pulmonary capillary, and pulmonary wedge pressures. Seven horses were assigned to exercise with each of 4 upper respiratory resistive loads in random order at intervals of at least 2 days: 1) control--no added resistive loads; 2) inspiratory resistive load (Iobst)--left laryngeal hemiplegia; 3) expiratory resistive load (Eobst)--one-way valve in the right nostril; and 4) combined inspiratory and expiratory resistive loads (CIEobst)--left nostril occlusion. On each occasion,...
Sonographic observations of the peripheral vasculature of the equine thoracic limb.
Anatomia, histologia, embryologia    February 1, 2000   Volume 28, Issue 5-6 281-289 doi: 10.1046/j.1439-0264.1999.00206.x
Hoffmann KL, Wood AK, McCarthy PH, Griffiths KA, Evans DL, Gill RW.Investigations of the equine peripheral vascular system have been constrained by the lack of a non-invasive method of examining the arteries and veins of the limbs of the conscious horse. Precise correlations were established between the gross anatomical features of the peripheral vessels and their B-mode sonographic appearance in each thoracic limb of 35 horses. A sonographic imaging protocol was established. Additional Doppler sonographic recordings defined the arterial waveforms and demonstrated that blood flow to the foot could be evaluated in the lateral proper digital artery, distal to t...
The distribution of nerve fibres immunoreactive for vasoactive intestinal peptide, calcitonin gene-related peptide, substance P and dopamine beta-hydroxylase in the normal equine larynx.
Research in veterinary science    December 23, 1999   Volume 67, Issue 3 251-259 doi: 10.1053/rvsc.1999.0325
Corcoran BM, Jarvis S, Hahn CN, Mayhew IG.The autonomic innervation of the mammalian respiratory system is complex, and involves a wide variety of peptide and non-peptide neurotransmitters which will have an important role in normal laryngeal function and the response to disease. This innervation has been partially described in the horse airway and lung, but there is no information on the equine larynx. This paper describes the expression and distribution of nerve fibres immunoreactive for vasoactive intestinal peptide (VIP), calcitonin gene-related peptide (CGRP), substance P (SP) and the adrenergic enzymatic marker dopamine beta-hyd...
Persistent vitelline arteries in a foal.
Equine veterinary journal    December 22, 1999   Volume 31, Issue 6 542-544 doi: 10.1111/j.2042-3306.1999.tb03867.x
De Bosschere H, Simoens P, Ducatelle R, Picavet T.No abstract available
Anatomic, radiographic and physiologic comparisons of the internal carotid and maxillary artery in the horse.
Veterinary journal (London, England : 1997)    November 24, 1999   Volume 158, Issue 3 182-189 doi: 10.1053/tvjl.1998.0350
Macdonald DG, Fretz PB, Baptiste KE, Hamilton DL.The anatomy of the internal carotid and maxillary arteries was examined using angiography, subtraction angiography and arterial cast preparations in three horses. Subtraction angiography was superior to angiography in demonstrating the anatomy of the occipital, external ophthalmic, ethmoidal and palatine arteries. In three horses manipulation of the internal carotid and occipital arteries during angiography resulted in vasospasm which prevented filling of these vessels with contrast. Direct arterial blood pressure measurements of the maxillary artery impinging on the guttural pouches was measu...
Pulmonary vascular pressures of strenuously exercising Thoroughbreds during intravenous infusion of nitroglycerin.
American journal of veterinary research    November 24, 1999   Volume 60, Issue 11 1436-1440 
Manohar M, Goetz TE.To determine whether intravenous infusion of nitroglycerin would modify pulmonary arterial, capillary, or venous hypertension in strenuously exercising Thoroughbreds. Methods: 5 healthy Thoroughbred horses. Methods: Right atrial, right ventricular, and pulmonary vascular pressures were measured. Each horse was used in a control treatment (not medicated) and a nitroglycerin infusion (20 microg/kg of body weight/min) at rest and during exercise on a treadmill. Sequence of treatments was randomized for each horse, and treatments were separated by a 7-day interval. Galloping at 14.2 m/s on a 5% up...
Endothelial cell infection in vivo by equine infectious anaemia virus.
The Journal of general virology    September 29, 1999   Volume 80 ( Pt 9) 2393-2397 doi: 10.1099/0022-1317-80-9-2393
Oaks JL, Ulibarri C, Crawford TB.Equine infectious anaemia virus (EIAV) infection of horses is characterized clinically by recurrent episodes of fever, thrombocytopenia and anaemia. In vivo, the only site of virus replication that has been previously demonstrated for EIAV is the tissue macrophage. In this study, in situ hybridization for EIAV was combined with immunohistochemistry for cell-type-specific markers to identify infected endothelial cells. EIAV-infected endothelial cells and macrophages were detected in horses infected with either virulent wild-type or with weakly virulent tissue culture-adapted strains of EIAV. Th...
Digital arterial thrombosis in a septicemic foal.
Journal of veterinary internal medicine    August 17, 1999   Volume 13, Issue 4 382-385 doi: 10.1892/0891-6640(1999)0132.3.co;2
Forrest LJ, Cooley AJ, Darien BJ.No abstract available
Cannulation in situ of equine umbilicus. Identification by gas chromatography-mass spectrometry (GC-MS) of differences in steroid content between arterial and venous supplies to and from the placental surface.
The Journal of steroid biochemistry and molecular biology    July 23, 1999   Volume 68, Issue 5-6 219-228 doi: 10.1016/s0960-0760(99)00034-5
Marshall DE, Gower DB, Silver M, Fowden A, Houghton E.Equine umbilicus was cannulated in utero and a series of cord plasma samples removed for analysis. After steroid extraction and derivatisation, gas chromatographic-mass spectrometric (GC-MS) analysis demonstrated large differences in steroid content between the plasma samples obtained from the umbilical artery and vein, the blood supplies leading to and from the placental surface, respectively. 3Beta-hydroxy-5,7-androstadien-17-one, dehydroepiandrosterone, pregnenolone, 3beta-hydroxy-5alpha-pregnan-20-one, 5-pregnene-3beta,20beta-diol and 5beta-pregnane-3beta,20beta-diol were identified as maj...
The role of prostanoids and nitric oxide in endotoxin-induced hyporesponsiveness of equine digital blood vessels.
Equine veterinary journal    July 13, 1999   Volume 31, Issue 3 212-218 doi: 10.1111/j.2042-3306.1999.tb03175.x
Bailey SR, Elliott J.Endotoxin has been implicated in the pathophysiology of acute laminitis. The aim of this study was to examine the direct effects of endotoxin on isolated equine digital blood vessels. Equine digital veins (EDV), incubated in Krebs-Henseleit solution containing lipopolysaccharide (LPS) (1 microg/ml) became hyporesponsive to 5-HT after 16 h. Cycloheximide and ibuprofen blocked this effect of LPS and increased the maximum response obtained to 5-HT when compared to control vessels. L-nitroarginine methyl ester (L-NAME) reversed the hyporesponsiveness caused by LPS. Vessels maintained in culture me...
1 15 16 17 18 19 34