Analyze Diet

Topic:Cadaver Study

Cadaver studies involving horses provide valuable insights into equine anatomy, pathology, and surgical techniques. These studies involve the examination and dissection of deceased horses to better understand the structure and function of various bodily systems. By utilizing cadavers, researchers and veterinary students can gain hands-on experience in identifying anatomical features, understanding disease processes, and refining surgical skills without the ethical concerns associated with live animal experimentation. Cadaver studies also contribute to the development of new diagnostic and therapeutic approaches by allowing for detailed exploration of equine anatomy and pathology. This page compiles peer-reviewed research studies and scholarly articles that explore the methodologies, findings, and applications of cadaver studies in equine science.
Gross, computed tomographic, and endoscopic anatomy of the equine carpal extensor tendon sheaths.
Veterinary surgery : VS    November 1, 2021   Volume 51, Issue 1 202-213 doi: 10.1111/vsu.13743
Baldwin CM, Morgan RE, Crawford AL, Villarino NF, Rubio-Martínez LM.(1) To describe the computed tomography (CT) and gross anatomy of the equine extensor carpi radialis sheath (ECRS) and common digital extensor sheath (CDETS); (2) to describe a single-portal endoscopic examination of the ECRS and CDETS. Methods: Ex vivo experimental. Methods: Thirty clinically normal cadaver thoracic equine limbs severed at the humeral diaphysis. Methods: Ten limbs underwent plain and intrathecal contrast CT examinations and gross dissection of the ECRS and CDETS. Single-portal endoscopic examination of ECRS and CDETS was attempted in 4 limbs and endoscopic examination was per...
Diffusion of dye after perineural injection of the palmar/plantar nerves in two different sites in horses: an ex-vivo study.
Veterinary research communications    October 29, 2021   Volume 46, Issue 1 283-288 doi: 10.1007/s11259-021-09856-6
de Souza AF, Pascual CJ, Maia BT, do Valle De Zoppa AL.This study aimed to evaluate the distribution of dye at two perineural injection sites of the palmar/plantar nerves and describe their anatomical variations of positioning at the level of the distal metacarpus/metatarsus in horses. Two ml of 1% methylene blue solution was injected in 24 limbs (12 forelimbs and 12 hindlimbs) of horse cadavers at two different points: Group 1: between the branch of the suspensory ligament and deep digital flexor tendon, and Group 2: between the deep and superficial digital flexor tendons. This was followed by dissection and evaluation of the solution diffusion. ...
Neurovascular variations in the proximal plantar metatarsal region of the horse.
Equine veterinary journal    September 27, 2021   doi: 10.1111/evj.13507
Milner PI, Dimmock O, Barnes K.Neurovascular variation may be relevant when performing surgical techniques to the proximal plantar metatarsal region. Objective: To document variations in the neurovascular anatomy of the proximal plantar metatarsal region and study the relationship of the neurovascular components to each other and other structures located in this area. Methods: Descriptive anatomical study. Methods: Paired cadaver hind limbs from 15 horses were dissected from the distal tibia to the metatarsophalangeal joint. Deep branch of the lateral plantar nerve (DBLPN) length, location of its origin from the lateral pla...
A study of the shoulder and elbow joints of the donkey (Equus asinus) by gross anatomical dissection, radiography, computed tomography, and intra-articular injection.
Morphologie : bulletin de l\'Association des anatomistes    August 11, 2021   Volume 106, Issue 354 177-187 doi: 10.1016/j.morpho.2021.07.002
Alsafy MAM, Elbakary RMA, Bassuoni NF.Joint diseases often represent the major part of equine clinician's caseloads. The current study aimed to document the normal anatomy of the donkey shoulder and elbow joints using computed tomography, cadaver sections, and radiography. Seven adult donkeys were used in this study. The current study proved there were no pouches of the donkey shoulder joint. Communication between the joint capsule and bicipital bursa was observed only in two limbs of four used in the present work. The joint was without pericapsular ligaments. The glenohumeral ligament was identified by the thickening of the artic...
Evaluation of the airway mechanics of modified toggle laryngoplasty constructs using a vacuum chamber airflow model.
Veterinary surgery : VS    July 26, 2021   Volume 50, Issue 7 1409-1417 doi: 10.1111/vsu.13690
Gray SM, Gutierrez-Nibeyro SD, Couëtil LL, Horn GP, Kesler RM, McCoy AM, Stewart MC, Schaeffer DJ.To evaluate the airway mechanics of modified toggle LP constructs in an airflow chamber model and compare these to the airway mechanics of standard LP constructs. Methods: Ex-vivo experimental study. Methods: Fifty-one equine cadaveric larynges. Methods: Bilateral LP constructs were performed using a modified toggle (n = 23) or a standard (n = 21) LP technique. Constructs were tested in an airflow model before and after cyclic loading which was designed to mimic postoperative swallowing. The cross-sectional area (CSA), peak translaryngeal airflow (L/s), and impedance (cmH 0/L/s) were deter...
Correlated Imaging of the Equine Hyoid Apparatus Using CT, Micro-CT, and Histology.
Frontiers in veterinary science    July 5, 2021   Volume 8 652563 doi: 10.3389/fvets.2021.652563
Hartl B, Egerbacher M, Kneissl SM. Detailed radiological evaluation of the normal hyoid apparatus by computed tomography (CT) has not yet been conducted. Thus, it is unclear what type of junction connects the different parts of the equine hyoid apparatus. To describe the normal CT anatomy of the equine hyoid apparatus, and to determine the junction type that connects the different parts of the hyoid apparatus. Combination of retrospective study and prospective cadaver study. The medical records of horses that underwent head CT scans from 2009 to 2018 were retrieved. Inclusion criteria for the CT scans were visibility of at ...
Gross post-mortem and histological features in 27 horses with confirmed lumbosacral region pain and five control horses: A descriptive cadaveric study.
Equine veterinary journal    June 12, 2021   doi: 10.1111/evj.13488
Quiney L, Stewart J, Routh J, Dyson S.There is a lack of understanding of the pathological and/or physiological nature of lumbosacral region pain. Objective: To describe the gross variations of the osseous and soft tissues of the lumbosacral region and report the histological findings of sections of nerve tissue in affected and control horses. Methods: Descriptive post-mortem case series. Methods: All horses had undergone full clinical and gait assessment, including ridden exercise. Horses with a substantial response to infiltration of local anaesthetic solution around the sacroiliac joint regions were included in the affected gro...
Ex vivo mechanical testing of various suture patterns for use in tendon plating.
Veterinary surgery : VS    June 2, 2021   Volume 50, Issue 6 1296-1303 doi: 10.1111/vsu.13659
Hale MJ, Zellner EM, Naiman JH, Kraus KH.To determine the influence of suture patterns on resistance to gap formation after tendon plating STUDY DESIGN: Ex vivo study SAMPLE POPULATION: Suspensory ligament and superficial and deep digital flexor tendons harvested from 16 neonatal cadaver foal limbs. Methods: Each tendon/ligament from a given limb was randomly assigned to one of three treatment groups consisting of a 7-hole veterinary cuttable plate fixed with alternating simple interrupted, figure-8, or hybrid suture patterns. The constructs were distracted at a rate of 1.0 mm/s to failure, as determined by the formation of a 1 m...
A study of ultrasound-guided perineural injection of the caudal cervical spinal nerve roots in equine cadavers.
Veterinary anaesthesia and analgesia    May 5, 2021   Volume 48, Issue 4 603-611 doi: 10.1016/j.vaa.2021.04.002
Cruz-Sanabria JA, Gaschen L, Bragulla HH, Mitchell M, Leise BS.To develop an ultrasound-guided cervical perineural injection technique for horses and to evaluate and compare the distribution of contrast agent among perineural, intra-articular and periarticular injections. Methods: Prospective, experimental cadaveric study. Methods: A total of 14 equine cadaveric necks. Methods: Bilateral ultrasound-guided perineural injection technique for the caudal cervical spinal nerve roots (CSNRs 5-7) was developed. Paramagnetic or iodinated contrast was injected and the distribution of contrast was evaluated using magnetic resonance (MR) or computed tomography (CT) ...
Standing trans-nasal endoscopic guided CO2 laser fenestration of the palatine bone to access the sphenopalatine sinus in a horse.
Veterinary surgery : VS    April 29, 2021   Volume 50, Issue 6 1350-1358 doi: 10.1111/vsu.13647
Perez JA, Hutton AE, Cudd SK, Brown JA.To describe a novel standing trans-nasal endoscopic guided CO2 laser fenestration approach to access the sphenopalatine sinus (SPS) in the horse. Methods: Case report. Methods: Cadaver study and client-owned 20-year-old Warmblood gelding. Methods: The rostral palatine bone within the nasopharynx was investigated as a possible site for fenestration to access the SPS in cadavers. The ability to fenestrate the SPS was tested in cadavers using a flexible endoscope and CO2 laser fiber inserted via biopsy channel. The fenestration procedure was then performed in a clinical case presented for unilate...
Effect of three different needle holders on gastrointestinal anastomosis construction time and bursting pressure in equine jejunal segments.
BMC veterinary research    April 15, 2021   Volume 17, Issue 1 167 doi: 10.1186/s12917-021-02871-4
Averay K, van Galen G, Ward M, Verwilghen D.Equine small intestinal resection and anastomosis is a procedure where optimizing speed, without compromising integrity, is advantageous. There are a range of different needle holders available, but little is published on the impact surgical instrumentation has on surgical technique in veterinary medicine. The objectives of this study were to investigate if the needle holder type influences the anastomosis construction time, the anastomosis bursting pressure and whether the bursting pressure is influenced by the anastomosis construction time. Single layer end-to-end jejunojejunal anastomoses w...
Mechanical Effect of Performance Pressure Boots on Cadaveric Equine Hindlimb Fetlock Biomechanics.
Animals : an open access journal from MDPI    March 30, 2021   Volume 11, Issue 4 958 doi: 10.3390/ani11040958
Symons J.Pressure boots are applied to hind limbs of showjumping horses with the intent to enhance jumping form. Manufacturers claim acupressure points enhance proprioception of hind limbs. With this increased awareness, horses are expected to retract their hind limbs to clear jump rails. This research aimed to investigate a more direct, mechanical effect of pressure boots on hind limb biomechanics. Cadaveric hind limbs ( = 6) were mechanically loaded in axial compression (3 cycles at 0.25 Hz, displacement control ~3300 N) with (2 trials) and without (2 trials) a pressure boot applied. During mechanica...
Description of a novel ultrasound guided peribulbar block in horses: a cadaveric study.
Journal of veterinary science    March 29, 2021   Volume 22, Issue 2 e22 doi: 10.4142/jvs.2021.22.e22
Leigh H, Gozalo-Marcilla M, Esteve V, Gutiérrez Bautista ÁJ, Martin Gimenez T, Viscasillas J.Standing surgery in horses combining intravenous sedatives, analgesics and local anaesthesia is becoming more popular. Ultrasound guided (USG) peribulbar nerve block (PB) has been described in dogs and humans for facial and ocular surgery, reducing the risk of complications versus retrobulbar nerve block (RB). Objective: To describe a technique for USG PB in horse cadavers. Methods: Landmarks and PB technique were described in two equine cadaver heads (Phase 1), with computed tomography (CT) imaging confirming contrast location and spread. In Phase 2, ten equine cadaver heads were randomised t...
Ultrasound-guided modified subcostal transversus abdominis plane block and influence of recumbency position on dye spread in equine cadavers.
Veterinary anaesthesia and analgesia    March 25, 2021   Volume 48, Issue 4 596-602 doi: 10.1016/j.vaa.2021.03.006
Freitag FAV, Amora DDS, Muehlbauer E, Dornbusch PT, Machado M, Montiani-Ferreira F, Prisco Farias EL, Valverde A, Duque Moreno JC.To describe and evaluate an ultrasound-guided modified subcostal approach for the transversus abdominis plane (TAP) block in horse cadavers in lateral or dorsal recumbency. Methods: Prospective, experimental cadaveric study. Methods: Study of one preserved foal and eight fresh adult horse cadavers. Methods: The lateral and ventral abdominal wall of a preserved cadaver was dissected to identify the muscles and nerves. A unilateral standard TAP block technique was performed (60 mL of methylene blue dye-bupivacaine) on a fresh cadaver in right lateral recumbency. A modified subcostal technique wa...
Ultrasound-guided erector spinae plane block in horses: a cadaver study.
Veterinary anaesthesia and analgesia    March 19, 2021   Volume 48, Issue 4 577-584 doi: 10.1016/j.vaa.2020.11.009
Delgado OBD, Louro LF, Rocchigiani G, Verin R, Humphreys W, Senior M, Campagna I.To describe dye distribution and spinal nerve involvement after a simulated erector spinae plane (ESP) block performed on fresh equine cadavers. Methods: Experimental cadaver study. Methods: A group of 11 adult equine cadavers. Methods: The spinal region surrounding the sixteenth thoracic vertebra (Th16) of one cadaver was removed and underwent magnetic resonance imaging. In 10 adult equine cadavers [body weight, 549 ± 58 kg (mean ± standard deviation)], 0.2 mL kg of a 50:1 2% lidocaine/dye solution was injected bilaterally (n = 20 injections) into the fascial plane between the transverse p...
Minimally invasive tenotomy of the tibial insertion of the semitendinosus muscle: An ex vivo study in horses.
Veterinary surgery : VS    March 11, 2021   Volume 50, Issue 4 843-847 doi: 10.1111/vsu.13609
Zetterström SM, Boone LH, Weatherall KM, Caldwell FJ.To describe a minimally invasive technique for semitendinosus tenotomy with ultrasonographic guidance and to evaluate procedural complications. Methods: Experimental study. Methods: Cadaveric equine hind limbs (n = 16). Methods: A stab incision was performed distocaudal to the tibial insertion of the semitendinosus muscle with ultrasonographic assistance. After transection of the tendon with an arthroscopic retrograde knife, the tendon edges palpably retracted, and complete transection was confirmed by ultrasound. Limbs were dissected to confirm the degree of tendon transection and to identify...
Ultrasonographic guidance for perineural injections of the cervical spinal nerves in horses.
Veterinary surgery : VS    March 10, 2021   Volume 50, Issue 4 816-822 doi: 10.1111/vsu.13610
Wood AD, Sinovich M, Prutton JSW, Parker RA.To evaluate the accuracy of ultrasonographic guidance for injection near the ventral rami of the cervical spinal nerves (VRCSN). Methods: Ex vivo study. Methods: Ten cadavers (n = 40 injections). Methods: Left and right VRCSN at C4/5 and C5/6 were infiltrated at the intervertebral foramen (IVF) under ultrasonographic guidance. A vertically orientated 3.5-MHz curvilinear probe was used to identify the craniocaudal midpoint of the articular process joint (APJ). The probe was moved ventrally until the IVF was identified. An 18-gauge 15-cm-long spinal needle was aimed immediately below the ventral...
In vitro assessment of the motion of equine proximal sesamoid bones relative to the third metacarpal bone under physiologic midstance loads.
American journal of veterinary research    February 26, 2021   Volume 82, Issue 3 198-206 doi: 10.2460/ajvr.82.3.198
Shaffer SK, Sachs N, Garcia TC, Fyhrie DP, Stover SM.To assess the motion of the proximal sesamoid bones (PSBs) relative to the third metacarpal bone (MC3) of equine forelimbs during physiologic midstance loads. Methods: 8 musculoskeletally normal forelimbs (7 right and 1 left) from 8 adult equine cadavers. Methods: Each forelimb was harvested at the mid-radius level and mounted in a material testing system so the hoof could be moved in a dorsal direction while the radius and MC3 remained vertical. The PSBs were instrumented with 2 linear variable differential transformers to record movement between the 2 bones. The limb was sequentially loaded ...
Does the Low-Field MRI Appearance of Intraosseous STIR Hyperintensity in Equine Cadaver Limbs Change when Subjected to a Freeze-Thaw Process?
Animals : an open access journal from MDPI    February 11, 2021   Volume 11, Issue 2 475 doi: 10.3390/ani11020475
Johnston GCA, Ahern BJ, Woldeyohannes SM, Young AC.Equine advanced imaging research involving racehorse fetlock pathology commonly uses cadaver limbs and a freeze-thaw process. The presence of short tau inversion recovery (STIR) signal intensity in the distal third metacarpal/metatarsal bone is of particular interest and may be clinically relevant in the diagnosis of horses at risk of fracture. However, little is known about the effect of the freeze-thaw process on the MRI appearance of STIR hyperintensity in these bones. This study compares the low-field MRI appearance of the distal third metacarpal/metatarsal bone from cadaver limbs of Thoro...
Ex vivo effects of corticosteroids on equine deep digital flexor and navicular fibrocartilage explant cell viability.
American journal of veterinary research    January 23, 2021   Volume 82, Issue 2 125-131 doi: 10.2460/ajvr.82.2.125
Sullivan SN, Cole SL, Stewart MC, Brokken MT, Durgam S.To investigate the effects of triamcinolone acetonide (TA) and methylprednisolone acetate (MPA) on the viability of resident cells within the fibrocartilage on the dorsal surface of the deep digital flexor tendon (FC-DDFT) and fibrocartilage on the flexor surface of the navicular bone (FC-NB) of horses. Methods: 12 to 14 explants of FC-DDFT and of FC-NB from grossly normal forelimbs of 5 cadavers of horses aged 9 to 15 years without evidence of musculoskeletal disease. Methods: Explants were incubated with culture medium (control) or TA-supplemented (0.6 or 6 mg/mL) or MPA-supplemented (0.5 or...
Optimisation and validation of immunohistochemical axonal markers for morphological and functional characterisation of equine peripheral nerves.
Equine veterinary journal    January 19, 2021   Volume 53, Issue 6 1188-1198 doi: 10.1111/evj.13403
Almuhanna AH, Cahalan SD, Lane A, Goodwin D, Perkins J, Piercy RJ.Horses are affected by various peripheral nerve disorders but defining their aetiology and pathophysiology is hampered by limited understanding of associated morphological and pathological changes and involvement of specific axonal types. Objective: To investigate the hypothesis that selected antibody markers, used in conjunction with various tissue processing methods, would enable identification of axons with different functional modalities within a range of equine peripheral nerves. Methods: Optimisation and validation study. Methods: A range of antibodies were evaluated immunohistochemicall...
Use of Hausdorff Distance and Computer Modelling to Evaluate Virtual Surgical Plans with Three-Dimensional Printed Guides against Freehand Techniques for Navicular Bone Repair in Equine Orthopaedics.
Veterinary and comparative orthopaedics and traumatology : V.C.O.T    January 13, 2021   Volume 34, Issue 1 9-16 doi: 10.1055/s-0040-1721846
Biedrzycki AH, Kistler HC, Perez-Jimenez EE, Morton AJ. The aim of this study was to evaluate the surgical execution of a virtual surgical plan (VSP) with three-dimensional (3D) guides against a freehand approach in the equine navicular bone using an automated computer analysis technique. Methods:  Eight pairs of cadaveric forelimb specimens of adult horses were used in an experimental study design with modelling. Limbs received either a 3.5 mm cortical screw according to a VSP or using an aiming device. Using computed tomography and computer segmentation, a comparison was made between the executed screw and the planned screw using the Ha...
Cadaveric comparison of the accuracy of ultrasound-guided versus ‘blind’ perineural injection of the tibial nerve in horses.
Veterinary journal (London, England : 1997)    January 6, 2021   Volume 269 105603 doi: 10.1016/j.tvjl.2020.105603
van der Laan M, Raes E, Oosterlinck M.During diagnostic evaluation of hindlimb lameness in horses the tibial nerve block is traditionally performed based on anatomical reference points, but it can be difficult to achieve effective local anaesthesia using this blind technique. Ultrasound (US)-guided injection could increase the accuracy of injection. The aim of this study was to compare the accuracy of both techniques. Twenty-one paired sets of cadaver hindlimbs were injected with 1 mL methylene blue using the blind or US-guided technique. There was no significant difference in stain width and length and in coloured nerve length be...
Radiographic assessment of carpal conformation in the horse, part 2: Finding acceptable limits to postural and rotational variations during radiography.
Anatomia, histologia, embryologia    January 3, 2021   Volume 50, Issue 3 467-492 doi: 10.1111/ahe.12651
Olusa TAO, Davies HMS.Finding an appropriate location for perpendicular positioning of the X-ray machine to produce zero lateromedial (ZLM) and zero dorsopalmar (ZDP) carpal images (views) and finding an acceptable range of rotational variations for measurement of carpal conformational parameters were two major challenges identified during field radiography of equine forelimbs. 16 cadaver forelimbs transacted at antebrachial midshaft from 10 horses (aged 9.13 ± 4.59 years) were axially mounted into a custom-built frame, and the radiographic machine and plate were perpendicularly aligned with the limb. Each limb...
Comparison of four peribulbar anaesthetic techniques: a preliminary study in equine cadavers.
Veterinary anaesthesia and analgesia    December 29, 2020   Volume 48, Issue 3 442-450 doi: 10.1016/j.vaa.2020.10.009
Rabbogliatti V, De Zani D, Zani DD, Di Cesare F, Brioschi FA, Gioeni D, Crivellari B, Ravasio G.To compare the peribulbar injectate distribution and probability of regional anaesthesia of four peribulbar anaesthetic techniques in equine cadavers. Methods: Prospective experimental cadaver study. Methods: A total of 12 isolated equine cadaver heads and 24 eyes. Methods: The 24 orbits underwent one of four injection techniques (six orbits each) with a mixture (1:4) of contrast medium and saline (CM): 20 mL ventrolateral peribulbar injection (V-20), 20 mL dorsolateral peribulbar injection (D-20), combined ventrolateral and dorsolateral peribulbar injections 10 mL each (VD-20) or 20 mL each (...
Assessment of intrasynovial injection in horses by contrast-enhanced ultrasonography using air bubbles created by agitation of solution.
Equine veterinary journal    December 21, 2020   Volume 53, Issue 6 1159-1168 doi: 10.1111/evj.13388
Ogden NKE, Cullen MD, Stack JD.Accuracy of intrasynovial injections can be challenging to assess in a clinical setting in horses. Contrast-enhanced ultrasonography (CEUS) using injectate agitated with air has been used to determine the success rates of synovial injections in human rheumatology. Objective: To assess the diagnostic sensitivity and specificity of CEUS and to describe its clinical use. Methods: Cadaveric study followed by a prospective descriptive observational study. Methods: Part 1: CEUS was performed following injection of agitated methylene-blue solution targeting 13 different anatomical synovial structures...
Effect of Scan Plane and Arthrography on Visibility and Interobserver Agreement of the Equine Distal Sesamoidean Impar Ligament on Magnetic Resonance Images.
Journal of equine veterinary science    August 15, 2020   Volume 94 103227 doi: 10.1016/j.jevs.2020.103227
Berner D, Mader D, Groß C, Gerlach K.In magnetic resonance imaging (MRI) examinations, moderate to severe changes of the distal sesamoidean impar ligament (DSIL) were found in horses with lameness localized to their feet. Histologic abnormalities were detected more commonly in lame horses. Because of its heterogeneity and small thickness, evaluation of the DSIL in MRI can be challenging. The aim of the study was to determine the optimal sequence and the ideal transverse perpendicular angle for visualization of the DSIL before and after arthrography of the distal interphalangeal joint (DIPJ). Twenty-five cadaver forelimbs were exa...
Anatomy and Ultrasound-Guided Injection of the Medial Branch of the Dorsal Ramus of the Cervical Spinal Nerves in the Horse: A Cadaveric Study.
Veterinary and comparative orthopaedics and traumatology : V.C.O.T    August 10, 2020   Volume 33, Issue 6 377-386 doi: 10.1055/s-0040-1714301
Corraretti G, Vandeweerd JM, Hontoir F, Vanderperren K, Palmers K. The aim of this study was to describe the anatomy of the nerves supplying the cervical articular process joint and to identify relevant anatomical landmarks that could aid in the ultrasound-guided location and injection of these nerves for diagnostic and therapeutic purposes. Methods:  Twelve cadaveric equine necks were used. Five necks were dissected to study the anatomy of the medial branch of the dorsal ramus of the cervical spinal nerves 3 to 7. Relevant anatomical findings detected during dissections were combined with ultrasonographic images obtained in one other neck. Six additiona...
Ex vivo modeling of the airflow dynamics and two-and three-dimensional biomechanical effects of suture placements for prosthetic laryngoplasty in horses.
American journal of veterinary research    July 24, 2020   Volume 81, Issue 8 665-672 doi: 10.2460/ajvr.81.8.665
Lynch NP, Jones SA, Bazley-White LG, Wilson ZF, Raffetto J, Pfau T, Cheetham J, Perkins JD.To identify the degree of left arytenoid cartilage (LAC) abduction that allows laryngeal airflow similar to that in galloping horses, assess 2-D and 3-D biomechanical effects of prosthetic laryngoplasty on LAC movement and airflow, and determine the influence of suture position through the muscular process of the arytenoid cartilage (MPA) on these variables. Methods: 7 equine cadaver larynges. Methods: With the right arytenoid cartilage maximally abducted and inspiratory airflow simulated by vacuum, laryngeal airflow and translaryngeal pressure and impedance were measured at 12 incremental LAC...
Influence of a purpose-built frame on the accuracy of computer-assisted orthopedic surgery of equine extremities.
Veterinary surgery : VS    July 11, 2020   Volume 49, Issue 7 1367-1377 doi: 10.1111/vsu.13484
de Preux M, Vidondo B, Koch C.To determine the influence of a purpose-built frame on the accuracy of screw placement during computer-assisted orthopedic surgery (CAOS) of the equine extremity. Methods: Experimental cadaveric study. Methods: Twenty-four paired equine cadaveric limbs obtained from seven horses. Methods: Three 4.5-mm cortex screws were inserted in lag technique in three different planes of orientation in the proximal phalanx (P1) by means of CAOS. In the study group (n = 12 limbs), the tracker was anchored on a purpose-built frame designed to stabilize the extremity. In the control group (n = 12 limbs), a con...