Analyze Diet

Topic:Fractures

Fractures in horses refer to the disruption in the continuity of a bone, often resulting from trauma, excessive stress, or pathological conditions. These injuries can vary in severity, from simple, non-displaced fractures to complex, comminuted fractures involving multiple bone fragments. Fractures can affect any bone in a horse's body, but they are most commonly observed in the limbs due to the high mechanical loads these structures endure. Diagnosis typically involves clinical examination and imaging techniques such as radiography or ultrasound to assess the extent and nature of the fracture. Treatment strategies depend on the type and location of the fracture and may include rest, immobilization, surgical intervention, or a combination of these approaches. This page aggregates peer-reviewed research and scholarly articles focusing on the etiology, diagnosis, management, and outcomes of fractures in horses, providing insights into current veterinary practices and advancements in equine orthopedic care.
Fracture of the 7th cervical and 1st thoracic vertebrae presenting as radial nerve paralysis in a horse.
The Canadian veterinary journal = La revue veterinaire canadienne    February 1, 1997   Volume 38, Issue 2 112 
Lopez MJ, Nordberg C, Trostle S.No abstract available
Concentrations of keratan sulfate in plasma and synovial fluid from clinically normal horses and horses with joint disease.
Journal of the American Veterinary Medical Association    February 1, 1997   Volume 210, Issue 3 369-374 
Todhunter RJ, Fubini SL, Freeman KP, Lust G.To determine whether keratan sulfate concentrations in plasma or synovial fluid from clinically normal horses were different from concentrations in horses with joint disease and whether concentrations varied with type of joint disease. Methods: Case-control study. Methods: 67 clinically normal horses, 10 clinically normal foals, and 160 horses with joint disease. Methods: ELISA was used to measure keratan sulfate concentrations. Results: Mean plasma keratan sulfate concentration (mean +/- SEM, 580 +/- 124 ng/ml) in foals peaked at 10 weeks of age. Mean plasma keratan sulfate concentration in c...
Residual strength of equine bone is not reduced by intense fatigue loading: implications for stress fracture.
Journal of biomechanics    February 1, 1997   Volume 30, Issue 2 109-114 doi: 10.1016/s0021-9290(96)00113-3
Martin RB, Gibson VA, Stover SM, Gibeling JC, Griffin LV.Fatigue or stress fractures are an important clinical problem in humans as well as racehorses. An important question in this context is, when a bone experiences fatigue damage during extreme use, how much is it weakened compared to its original state? Since there are very limited data on this question and stress fractures are common in racehorses, we sought to determine the effect of fatigue loading on the monotonic strength of equine cortical bone. Beams were machined from the dorsal, medial and lateral cortices of the third metacarpal bones of six thoroughbred racehorses. Beams from left and...
High stability of the Ilizarov ringfixator in a metacarpal fracture of an Arabian foal.
Archives of orthopaedic and trauma surgery    January 1, 1997   Volume 116, Issue 5 287-289 doi: 10.1007/BF00390055
Jukema GN, Settner M, Dunkelmann G, Tilkorn P, Niemeyer OW, Hierholzer G.In a case of I degree open multifragmentary metacarpal fracture of a 4-week-old Arabian foal, an osteosynthesis with the Ilizarov ringfixator was performed. Immediate full weight-bearing (100 kg) was possible, demonstrating the high stability of the Ilizarov ringsystem. After 12 weeks, sufficient bony union was achieved, and the fixator could be removed. At that time, the body weight of the foal was 170 kg. In our opinion, this case proves the high stability and efficiency of the ringsystem under difficult and unusual conditions.
Comparison of racing performance before and after treatment of incomplete, midsagittal fractures of the proximal phalanx in standardbreds: 49 cases (1986-1992).
Journal of the American Veterinary Medical Association    January 1, 1997   Volume 210, Issue 1 82-86 
Tetens J, Ross MW, Lloyd JW.To assess the effect of incomplete, midsagittal fractures of the proximal phalanx (P1) on racing performance in Standardbreds. Methods: Retrospective cohort study. Methods: 49 Standardbred horses admitted to the George D. Widener Hospital for Large Animals between July 1986 and December 1992 with a definitive radiographic diagnosis of an incomplete, midsagittal fracture of P1 and a known method of treatment. Methods: Performance index and racing time were compared before and after diagnosis and treatment of fracture, using ANOVA that controlled for the effects of horse, gender, age, track leng...
What is your diagnosis? Fracture of the distal third of the patella in a horse.
Journal of the American Veterinary Medical Association    December 1, 1996   Volume 209, Issue 11 1847-1848 
Anderson BH, Turner TA, Johnson GR.No abstract available
Treatment of a comminuted frontal-plane fracture of the distal phalanx in a horse.
Journal of the American Veterinary Medical Association    November 15, 1996   Volume 209, Issue 10 1750-1752 
Anderson BH, Turner TA, Kobluk CN.Successful treatment of a comminuted frontal plane fracture of the distal phalanx in a horse is described. The bone fractured through the solar canal, close to the insertion of the deep digital flexor tendon. A hoof case was used to reduce bending and tensile stresses on the solar surface by limiting expansion of the hoof wall during weightbearing. In addition, the heel was elevated, using 3 degrees wedge pads incorporated within the hoof cast, to reduce distraction at the fracture site caused by the pull of the deep digital flexor tendon. Two casts were used over a 4-month period. Complete ra...
High-speed exercise history and catastrophic racing fracture in thoroughbreds.
American journal of veterinary research    November 1, 1996   Volume 57, Issue 11 1549-1555 
Estberg L, Stover SM, Gardner IA, Drake CM, Johnson B, Ardans A.To investigate the relation between several racing speed history characteristics and risk of fatal skeletal injury (FSI) in racing Thoroughbreds. Methods: 64 Thoroughbreds euthanatized during a 9-month period in 1991 at a California racemeet because of a catastrophic fracture incurred while racing (cases), identified retrospectively. For each race in which an FSI occurred, 1 control horse was randomly selected from the noncatastrophically injured participants. Methods: Racing and officially timed workout histories were obtained for each horse. Several history characteristics were calculated to...
What is your diagnosis? Carpal bone fractures in a racing horse.
Journal of the American Veterinary Medical Association    October 1, 1996   Volume 209, Issue 7 1237-1238 
Sedrish SA, Martin GS, Pechman RD.No abstract available
Surgical management of a foal with a humerus-radius-ulna fracture.
Equine veterinary journal    September 1, 1996   Volume 28, Issue 5 416-420 doi: 10.1111/j.2042-3306.1996.tb03115.x
Auer JA, Struchen CH, Weidmann CH.No abstract available
In vitro fatigue behavior of the equine third metacarpus: remodeling and microcrack damage analysis.
Journal of orthopaedic research : official publication of the Orthopaedic Research Society    September 1, 1996   Volume 14, Issue 5 794-801 doi: 10.1002/jor.1100140517
Martin RB, Stover SM, Gibson VA, Gibeling JC, Griffin LV.We studied remodeling and microcrack damage in specimens of Thoroughbred racehorse third metacarpal bone that had been subjected to monotonic or fatigue failure. We asked three questions. What effects does mechanical loading have on histologically observable microcrack damage? Are there regional variations in remodeling of the equine cannon bone, and do these variations correlate with mechanical properties? To what extent are remodeling and microcrack damage age-dependent? Machined beams from the medial, lateral, and dorsal cortices were loaded to fracture in four-point bending monotonically, ...
In vitro determination of equine third metacarpal bone unloading, using a full limb cast and a walking cast.
American journal of veterinary research    September 1, 1996   Volume 57, Issue 9 1386-1389 
Brommer H, Back W, Schamhardt HC, Rijkenhuizen AB, Barneveld A.To improve fracture treatment, in vitro experiments were performed to study the influence of a full limb cast and a walking cast on the loading regimen of bones in the distal portion of the equine forelimb. Methods: 6 forelimbs of 6 Shetland ponies. Methods: Loading of the third metacarpal bone was considered a representative measure for distal limb loading. Electrical resistance rosette strain gauges were attached to the dorsal, palmar, medial, and lateral surfaces of the midshaft of this bone in 6 forelimbs of 6 Shetland ponies. The limbs were tested in a pneumatic loading device to a maxima...
Oblique views of the ilium and the scintigraphic appearance of stress fractures of the ilium.
Equine veterinary journal    September 1, 1996   Volume 28, Issue 5 355-358 doi: 10.1111/j.2042-3306.1996.tb03105.x
Hornof WJ, Stover SM, Koblik PD, Arthur RM.The research article discusses a study on the use of oblique dorsal views in detecting stress fractures in horses who participate in races. The aim of the researchers was to […]
The effect of hole diameter on the torsional mechanical properties of the equine third metacarpal bone.
Veterinary surgery : VS    September 1, 1996   Volume 25, Issue 5 371-375 doi: 10.1111/j.1532-950x.1996.tb01429.x
Seltzer KL, Stover SM, Taylor KT, Willits NH.The torsional monotonic structural material properties of equine metacarpi with or without, either a 5/16 inch or 3/8 inch diameter bicortical lateromedial middiaphyseal hole were assessed to determine the effect of a hole on metacarpal strength. Torsional stiffness was not significantly effected by the presence of a bicortical hole, whereas yield and failure angles, torques and energies of metacarpi with a hole were 51% to 97% of those of intact bones. Significant differences were not apparent for yield and failure mechanical properties between metacarpi with a 5/16 inch diameter hole and met...
What is your diagnosis? Oblique fracture of the right hind distal phalanx in a horse.
Journal of the American Veterinary Medical Association    August 15, 1996   Volume 209, Issue 4 729-730 
Sedrish SA, Valdes-Vazquez MA, Pechman R.No abstract available
Instrumentation and techniques in equine fracture fixation.
The Veterinary clinics of North America. Equine practice    August 1, 1996   Volume 12, Issue 2 283-302 doi: 10.1016/s0749-0739(17)30283-3
Auer JA, Watkins JP.In recent years fracture fixation in the horse has changed significantly. New devices, mainly adapted from the human field, have been successfully introduced into large animal surgery. Examples of such implants include the DCS/DHS implant system, the self-tapping screw, the cannulated screw, and the pinless external fixator. However, new devices have also been developed exclusively for equine fracture management, including the interlocking intramedullary nail and the external skeletal fixation device. With these devices the surgeon has more options for repairing fractures in horses. Neverthele...
Tibial stress fractures in racing standardbreds: 13 cases (1989-1993).
Journal of the American Veterinary Medical Association    August 1, 1996   Volume 209, Issue 3 634-637 
Ruggles AJ, Moore RM, Bertone AL, Schneider RK, Bailey MQ.To determine clinical signs, radiographic and scintigraphic findings, and performance outcome of racing Standardbreds with tibial stress fractures. Methods: Retrospective case series. Methods: 13 racing Standardbreds with tibial stress fractures. Methods: Information concerning clinical signs, diagnostic evaluation, and recommendations was obtained by review of the medical records. Performance information before and after diagnosis of the fracture was collected from racing records, and follow-up information was obtained from the owners or trainers by use of a telephone questionnaire. Results: ...
Hyaluronate and large molecular weight proteoglycans in synovial fluid from horses with various arthritides.
American journal of veterinary research    June 1, 1996   Volume 57, Issue 6 932-937 
Tulamo RM, Houttu J, Tupamäki A, Salonen M.To investigate the presence of large molecular weight (MW) proteoglycans (PG) and hyaluronate (HA) in synovial fluid (SF) from horses with various arthritides and from control joints. Methods: Horses with acute (< 2 weeks) or chronic (> 4 weeks) lameness were examined by clinical examination, intrasynovial anesthesia, radiography, arthroscopy, and SF analysis. Joints were grouped on the basis of diagnosis: acute traumatic arthritis, chronic traumatic arthritis (with a subgroup of degenerative joint disease), intra-articular fracture, and infectious arthritis. Methods: 31 horses with arthritis ...
What is your diagnosis? Tarsal bone slab fracture in a horse.
Journal of the American Veterinary Medical Association    May 1, 1996   Volume 208, Issue 9 1385-1386 
Sedrish SA, Moore RM, Partington BP.No abstract available
Application of a hook plate for management of equine ulnar fractures.
Veterinary surgery : VS    May 1, 1996   Volume 25, Issue 3 207-212 doi: 10.1111/j.1532-950x.1996.tb01400.x
Murray RC, Debowes RM, Gaughan EM, Bramlage LR.Closed fractures of the proximal aspect of the ulna were repaired in 10 horses younger than or equal to 6 months of age by application of a hook plate using a tension band principle. Ulnar fractures were classified as type 1A (2 horses), type 1B (4 horses), type 2 (1 horse), type 3 (1 horse), and type 4 (2 horses); all fractures had displacement of a proximal fragment. Complications were implant deformation (4 horses), screw pullout (1 horse), osseous sequestration (1 horse), ulnar fracture through a hole used to apply a tension device (1 horse), and metacarpophalangeal deformity associated wi...
Strain-rate-dependent mechanical properties of the equine hoof wall.
The Journal of experimental biology    May 1, 1996   Volume 199, Issue Pt 5 1133-1146 doi: 10.1242/jeb.199.5.1133
Kasapi MA, Gosline JM.The mechanical properties of fully hydrated equine hoof wall were examined at various loading rates in compact tension (CT) fracture, tensile and three-point bending dynamic tests to determine possible effects of hoof wall viscoelasticity on fracture toughness and tensile parameters. Four cross-head rates were used in CT tests: 1.7 x 10(-5), 1.7 x 10 (-3), 1.7 x 10(-2) and 2.5ms-1; four strain rates were used in tensile tests: 1.6 x 10(-3), 3.2 x 10(-2), 0.33 and 70s(-1). Speeds for the highest test rates were achieved using a large, custom-built impact pendulum. Bending test frequencies range...
An in vitro biomechanical study of a multiplanar circular external fixator applied to equine third metacarpal bones.
Veterinary surgery : VS    January 1, 1996   Volume 25, Issue 1 1-5 doi: 10.1111/j.1532-950x.1996.tb01370.x
Cervantes C, Madison JB, Miller GJ, Casar RS.The biomechanical characteristics of a 4-ring circular multiplanar fixator applied to equine third metacarpal bones with a 5 mm mid-diaphyseal osteotomy gap were studied. Smooth Steinmann pins, either 1/8 inch, 3/16 inch, or 1/4 inch, were driven through pilot holes in the bone in a crossed configuration and full pin fashion and fastened to the fixator rings using cannulated fixation bolts. The third metacarpal bone fixator constructs were tested in three different modes (cranial-caudal four-point bending, axial compression, and torsion). Loads of 2,000 N were applied in bending and axial comp...
An unusual case of distal phalanx fracture in a horse.
The Veterinary record    December 9, 1995   Volume 137, Issue 24 613-615 
McDiarmid AM.A mature thoroughbred cross gelding with an acute onset forelimb lameness was found to have sustained a fracture to the distal phalanx. The fracture traversed the distal phalanx In a lateromedial direction dividing the phalanx into two halves, dorsally and palmarly and was classed a frontal fracture. The horse was treated conservatively and after 14 months rest it returned to work. Three years later the horse has remained sound.
Use of antibiotic-impregnated polymethyl methacrylate for treatment of an open radial fracture in a horse.
Journal of the American Veterinary Medical Association    December 1, 1995   Volume 207, Issue 11 1454-1457 
Schneider RK, Andrea R, Barnes HG.An open, contaminated, comminuted fracture of the radius of a 500-kg adult horse was diagnosed. Antibiotic-impregnated polymethyl methacrylate implants were placed into the fracture site to help eliminate infection from the limb. Later in the course of treatment, lag screws were placed across the fracture to generate compression and healing. The fracture healed, and the horse was released to its owners. The implants were not removed, and only a mild lameness existed 90 days later.
Double-plate fixation of comminuted fractures of the second phalanx in horses: 10 cases (1985-1993).
Journal of the American Veterinary Medical Association    December 1, 1995   Volume 207, Issue 11 1458-1461 
Crabill MR, Watkins JP, Schneider RK, Auer JA.To determine the technique used, and the outcome for, double-plate fixation of comminuted fractures of the second phalanx of horses. Methods: Retrospective analysis of medical records. Methods: 10 horses with comminuted fractures of the second phalanx that were treated by use of double-plate fixation. Methods: Two 4- to 6-hole dynamic compression plates were abaxially placed to achieve arthrodesis of the proximal interphalangeal joint and fixation of the fracture of the second phalanx. Results: Arthrodesis and fracture healing were detected in all horses. Conclusions: Horses with comminuted fr...
Use of tension band wires in horses with fractures of the ulna: 22 cases (1980-1992).
Journal of the American Veterinary Medical Association    October 15, 1995   Volume 207, Issue 8 1085-1089 
Martin F, Richardson DW, Nunamaker DM, Ross MW, Orsini JA.Twenty-two horses with ulnar fractures were treated, using tension band wires alone or tension band wires in combination with pins or cortical bone screws. Age of the horses ranged from 2 weeks to 12 years (median, 4 months), and body weight ranged from 68 to 477 kg (median, 181 kg). Fractures were classified according to the Donecker and Bramlage ulnar fracture classification and included type 1-a (4 horses), type 1-b (4), type-2 (6), type-3 (1), type-4 (3), and type-5 (4), fractures. Tension band wires alone were used in 7 horses. Tension band wires were used in conjunction with unthreaded p...
Histologic appearance of axial osteochondral fragments from the proximoplantar/proximopalmar aspect of the proximal phalanx in horses.
Journal of the American Veterinary Medical Association    October 15, 1995   Volume 207, Issue 8 1076-1080 
Nixon AJ, Pool RR.Osteochondral fragments from the axial proximoplantar/proximopalmar region of the proximal phalanx were removed from 38 joints in 30 horses. Ninety-three percent of the horses were Standardbreds, and 28 of the 30 had a low-grade lameness. All but 1 of the horses had hind limb involvement. A total of 43 fragments were removed. Most (71%) of the fragments involved the medial aspect of the joint and had to be dissected from a covering of synovial tissue. Histologically, the circumference of most fragments consisted of a transition zone at the attachment of the joint capsule, a region of nonarticu...
Fracture of the distal sesamoid bone in horses: 17 cases (1982-1992).
Journal of the American Veterinary Medical Association    October 1, 1995   Volume 207, Issue 7 924-927 
Lillich JD, Ruggles AJ, Gabel AA, Bramlage LR, Schneider RK.Medical records of 17 horses in which a distal sesamoid bone fracture was diagnosed between 1982 and 1992 were reviewed. There were 8 Standardbreds, 6 Quarter Horses, 2 Thoroughbreds, and 1 Arabian. Mean age was 4.7 years. A forelimb was affected in 15 horses, and a hind limb was affected in 2. All horses were lame, and most were grade III/V lame at the trot. In all horses, the diagnosis was confirmed by means of radiography. Five horses were treated with stall rest alone; 5 underwent neurectomy; 4 were treated with stall rest and corrective shoeing; and 1 was treated with stall rest and exter...
What is your diagnosis? Biaxial fractures of the distal portion of the second and fourth metatarsal bones.
Journal of the American Veterinary Medical Association    September 1, 1995   Volume 207, Issue 5 561-562 
Hogan PM, Watkins JP, Black RJ.No abstract available
Partial excision of the clavicle for nonunion in National Hunt Jockeys.
The Journal of bone and joint surgery. British volume    September 1, 1995   Volume 77, Issue 5 778-780 
Middleton SB, Foley SJ, Foy MA.National Hunt jockeys suffer a disproportionate number of clavicular fractures and their return to riding may be considerably delayed by refracture and symptomatic nonunion, with obvious implications. We report six such cases in which excision of the clavicular fragment distal to the fracture was associated with an early return to work and no recurrent injury to the shoulder.
1 23 24 25 26 27 38