Analyze Diet

Topic:Hemodynamics

Hemodynamics in horses refers to the study of blood flow and the forces involved in circulation within the equine cardiovascular system. It encompasses the examination of heart function, blood pressure, and the distribution of blood to various tissues and organs. Key parameters in equine hemodynamics include cardiac output, vascular resistance, and blood volume. These factors are integral to understanding how horses respond to exercise, stress, and various health conditions. This page aggregates peer-reviewed research studies and scholarly articles that explore the mechanisms, measurement techniques, and clinical implications of hemodynamic processes in equine physiology and veterinary medicine.
The rate of rise of intraventricular pressure as an index of myocardial contractility in conscious and anaesthetised ponies.
Research in veterinary science    September 1, 1976   Volume 21, Issue 2 176-183 
Hillidge CJ, Lees P.Measurements of the rate of rise of left ventricular blood pressure (dP/dt) have been made in conscious and anaesthetised ponies. Concurrent measurements of heart rate, mean arterial pressure and left ventricular pressure were also made in order to assess their relationship to values of dP/dt. Thiopentone-halothane and thiopentone-ether anaesthesia reduced the maximal rate of rise of intraventricular pressure (dP/dt max) from conscious control levels. After correcting for variations in the loading conditions of the ventricle, the depressant effect of halothane was still apparent, but the actio...
Letter: Raised fetal blood pressure and haemorrhage in CNS of newly born foals.
The Veterinary record    August 7, 1976   Volume 99, Issue 6 111-112 doi: 10.1136/vr.99.6.111
Rossdale PD, Jeffcott LB, Palmer AC.No abstract available
An indirect method for measurement of systemic blood pressure in animals.
Nihon juigaku zasshi. The Japanese journal of veterinary science    June 1, 1976   Volume 38, Issue 03 305-308 doi: 10.1292/jvms1939.38.305
Sawazaki H, Hirose H.No abstract available
Estimation of cardiac output in the horse by thermodilution techniques.
American journal of veterinary research    June 1, 1976   Volume 37, Issue 6 697-700 
Muir WW, Skarda RT, Milne DW.An evaluation and comparison of thermodilution technique with dye dilution technique was made in the computation of cardiac output in 39 conscious adult horses (av body wt, 450 kg). Estimation of cardiac output by thermodilution was found to compare favorably with values obtained from dye dilution when a volume of 30 to 40 ml at a temperature of 0 C was used. Difficulties in obtaining accurate thermodilution curves in the horse seem predominantly associated with errors in mixing and observation.
Hot film coronary artery velocity measurements in horses.
Cardiovascular research    May 1, 1976   Volume 10, Issue 3 301-313 doi: 10.1093/cvr/10.3.301
Nerem RM, Rumberger JA, Gross DR, Muir WW, Geiger GL.Coronary velocity measurements have been carried out in anaesthetized, open-chest horses using a constant-temperature, hot-film anemometer system. L-shaped needle probes inserted by direct vessel puncture have been used to measure velocity profiles in the left common, left anterior descending (LAD), and left circumflex coronary arteries. The flow conditions were characterized by peak Reynolds numbers from approximately 200 to 1500 and values of the unsteadiness parameter from 3 to 10. These measurements indicate that in the left common coronary artery the profile is in general skewed towards t...
Ultrasonic measurement of arterial blood pressure in conditioned thoroughbreds.
Equine veterinary journal    April 1, 1976   Volume 8, Issue 2 55-57 doi: 10.1111/j.2042-3306.1976.tb03290.x
Johnson JH, Garner HE, Hutcheson DP.Indirect systolic and diastolic arterial pressure measurements of 456 Thoroughbred horses of various ages and sex stabled at 9 different race tracks were measured with an ultrasonic-Doppler device interfaced with a sphygmomanometer cuff. The mean systolic pressure was 111.8 +/- 13.3 mmHg and the mean diastolic pressure was 69.6 +/- 13.8 mmHg in this population.
Proceedings: Assessment of myocardial function in conscious and anaesthetized ponies.
The Journal of physiology    March 1, 1976   Volume 256, Issue 1 22P-23P 
Hillidge CJ, Lees P.No abstract available
Technique for arterial and mixed venous blood sampling in working saddle horses.
The British veterinary journal    March 1, 1976   Volume 132, Issue 2 172-177 doi: 10.1016/s0007-1935(17)34739-5
Littlejohn A, Kruger JM.No abstract available
A computer analysis of high frequency disturbances in arterial blood flow.
Computers and biomedical research, an international journal    February 1, 1976   Volume 9, Issue 1 75-88 doi: 10.1016/0010-4809(76)90052-5
McEvoy NM, Pimmel RL, Nerem RM.No abstract available
Circulatory effects of splenectomy in the horse. IV. Effect on blood flow and blood lactate at rest and during exercise.
Zentralblatt fur Veterinarmedizin. Reihe A    December 1, 1975   Volume 22, Issue 10 801-807 
Persson SG, Bergsten G.No abstract available
Cardiopulmonary measurements in nonanesthetized, resting normal ponies.
American journal of veterinary research    November 1, 1975   Volume 36, Issue 11 1667-1670 
Orr JA, Bisgard GE, Forster HV, Rawlings CA, Buss DD, Will JA.Cardiopulmonary measurements were determined in 19 nonanesthetized, normal ponies. Mean values for arterial pressure, pulmonary arterial pressure, cardiac output, heart rate, packed cell volume, and hemoglobin are reported, as well as acid-base determinations of arterial blood and cerebrospinal fluid. Respiratory function test data include total ventilation, respiratory rate, alveolar ventilation, oxygen uptake, and carbon dioxide output. The data compare favorably with the available data from previous reports on ponies. Because of large day-to-day variations in total ventilation, alveolar ven...
[The systolic blood pressure during fluothane anesthesia in horses].
Berliner und Munchener tierarztliche Wochenschrift    October 1, 1975   Volume 88, Issue 19 365-367 
Neumann H, Wintzer HJ.No abstract available
Preliminary observations on cranial cardiovascular changes during asphyxia in the newborn foal.
Journal of reproduction and fertility. Supplement    October 1, 1975   Issue 23 695-699 
Johnson P, Rossdale PD.This paper describes preliminary experiments designed to test the hypothesis that cerebral damage is caused by cardiovascular events involving explosive changes in cerebral blood flow during birth. These events may be responsible for the convulsive episodes of foals suffering from the neonatal maladjustment syndrome.
Pulmonary arterial wedge pressures: blood gas tensions and pH in the resting horse.
American journal of veterinary research    October 1, 1975   Volume 36, Issue 10 1431-1434 
Milne DW, Muir WW, Skarda RT.Blood pressure recordings were made from right atrium, right ventricle, pulmonary trunk, and pulmonary arterial "wedge" positions in the standing, resting, adult horse. Similarly, comparisons were made of blood samples collected from these vascular positions, as well as from jugular vein and carotid artery. A consistently lower partial pressure of carbon dioxide and a greater partial pressure of oxygen and pH were found in blood samples from pulmonary arterial wedge than from carotid artery. A technique for safe and rapid collection of pulmonary trunk and pulmonary arterial wedge blood gases, ...
Cerebrospinal fluid alkalosis during high-altitude sojourn in unanesthetized ponies.
Respiration physiology    October 1, 1975   Volume 25, Issue 1 23-37 doi: 10.1016/0034-5687(75)90048-1
Orr JA, Bisgard GE, Forster HV, Buss DD, Dempsey JA, Will JA.Unanesthetized adult female ponies were studied near sea level (250 m) and during sojourns to 3400 m (N=6) and 4300 m (N=7) altitude. The pH, PCO2, and PO2 of arterial blood and pH and PCO2 of cerebrospinal fluid (CSF) were measured under conditions of acute (1 hr) and chronic (1-45 days) hypoxia. Cerebrospinal fluid was sampled from the cisterna magna of the awake pony and arterial blood withdrawn from an indwelling arterial catheter. In both groups of animals, PaCO2 decreased slightly after 1 hr of hypoxia (delta PaCO2= - 0.6 mm Hg at 3400 m; - 3.9 mm Hg at 4300 m), decreased further after 1...
Hemodynamic studies in conscious domestic ponies.
The Journal of surgical research    August 1, 1975   Volume 19, Issue 2 107-113 doi: 10.1016/0022-4804(75)90114-6
Amend JF, Garner HE, Rosborough JP, Hoff HE.No abstract available
Positive end-expiratory pressure in anaesthetized spontaneously breathing horses.
British journal of anaesthesia    August 1, 1975   Volume 47, Issue 8 819-824 doi: 10.1093/bja/47.8.819
Hall LW, Trim CM.Horses breathing spontaneously under halothane anaesthesia were subjected to expiratory resistance by the introduction of a water-trap into the expiratory limb of a circle absorber. Resistances of 10 and 20 cm H2O produced no significant increase in PaO2 (P greater than 0.05) during halothane/air and halothane/oxygen anaesthesia. The imposition of resistance was associated with an increase in PaCO2 and a significant increase in mixed venous PCO2. In three animals subjected to 20 cm H2O resistance under halothane/air anaesthesia, the cardiac output was reduced (P less than 0.01). It was conclud...
Vascular responses in the equine digit.
American journal of veterinary research    August 1, 1975   Volume 36, Issue 08 1249-1253 
Robinson NE, Dabney JM, Weidner WJ, Jones GA, Scott JB.The digital circulation was isolated in 12 ponies under pentobarbital anesthesia. Blood flow was either controlled by a pump or measured under natural perfusion. The responses to rapid changes and stoppages of blood flow indicated no evidence of autoregulation or reactive hyperemia. Local administration of acetylcholine, histamine, and prostaglandins E1 and E2 decreased prevenous resistance, whereas epinephrine and serotonin caused prevenous constriction. Large doses of epinephrine and serotonin decreased venous caliber. The effects of prostaglandins A1 and F2alpha were variable. The equine di...
Papers and articles measurement of central venous pressure in horses.
The Veterinary record    July 26, 1975   Volume 97, Issue 4 66-69 doi: 10.1136/vr.97.4.66
Hall LW, Nigam JM.Central venous pressure measurements were made in 74 horses and ponies free from clinical evidence of cardiopulmonary disease. Using the sternal manubrium as the zero reference point, the mean value obtained was 12 cm H2O (S.D. +/- 6). There was a significant correlation with body weight (r=0.6, p less than 0.001) but there was none with age, sex, breed or type. During halothane anaesthesia, using the same reference point, the mean value was 24.5 cm H2O (S.D. +/- 6) in 28 animals in right lateral recumbency, 29 cm H2O (S.D. +/- 8) in 17 animals in left lateral recumbency and -6 cm H20 (S.D. +/...
Ventricular septal defect in a 7-year-old gelding.
Journal of the American Veterinary Medical Association    July 1, 1975   Volume 167, Issue 1 49-50 
Glazier DB, Farrelly BT, O'Connor J.A congenital heart defect characterised by persistent patency (open-ness) of the ventricular septum, permitting flow of blood directly between ventricles, bypassing the pulmonary circulation and resulting in various degrees of cyanosis (blue discolouration of the skin) due to oxygen deficiency. Clinical signs include systolic murmur and a palpable thrill on both sides of the chest, dyspnoea and poor tolerance of exercise.
Prolonged perfusion with a membrane oxygenator in awake ponies.
The Journal of thoracic and cardiovascular surgery    April 1, 1975   Volume 69, Issue 4 539-551 
Rawlings CA, Bisgard GE, Dufek JH, Buss DD, Will JA, Birnbaum ML, Chopra PS, Kahn DR.Prolonged extracorporeal membrane oxygenation (PEMO) was performed in 6 adult ponies with the membrane oxygenator in vein-to-artery bypass circuit. A flow rate equal to 46 per cent of control cardiac output was diverted through the PEMO circuit of 10 to 24 hours. Three of the 6 ponies were perfused for at least 20 hours and developed no complications. Immediately following initiation of PEMO, left ventricular output decreased; however, in the interval between 6 and 24 hours, left ventricular output was increased above control levels. Aortic pressure and left ventricular work were markedly elev...
Influence of azaperone and metomidate on cardiovascular and respiratory functions in the pony.
The British veterinary journal    January 1, 1975   Volume 131, Issue 1 50-64 doi: 10.1016/s0007-1935(17)35387-3
Hillidge CJ, Lees P, Serrano L.No abstract available
Hypoxic pulmonary hypertension in the pony.
American journal of veterinary research    January 1, 1975   Volume 36, Issue 1 49-52 
Bisgard GE, Orr JA, Will JA.Hemodynamic measurements were made in 6 ponies at low altitude (Madison, WI, altitude, 250 m) and after 1, 2, 4, and 6 weeks at high altitude (Climax, CO, altitude, 3,400 m). The salient findings were that ponies maintain an increased heart rate and cardiac output and develop significant pulmonary hypertension at high altitude. The average control resting mean pulmonary artery pressure (BPpul) was 25.1 mm of Hg at 250 m; this value increased to 56.3 mm of Hg after 6 weeks at 3,400 m. An additional finding was that the pulmonary vascular response to acute hypoxia seemed to increase with time at...
Systolic time intervals in domestic ponies: alterations in a case of coarctation of the aorta.
Canadian journal of comparative medicine : Revue canadienne de medecine comparee    January 1, 1975   Volume 39, Issue 1 62-66 
Amend JF, Ross JN, Garner HE, Rosborough JP, Hoff HE.This report describes the measurement of systolic time intervals in a nine year old female domestic pony which was found at necropsy to show coarctation of the aorta and bilateral ventricular hypertrophy. Electrocardiogram, phonocardiogram and direct arterial blood pressure were recorded from the pony in a standing unmedicated state and systolic time intervals were measured from the resulting tracings. A prolongation of left ventricular ejection time and shortening of the pre-ejection period were observed in comparison to a group of normal ponies similarly examined. Such changes are consistent...
The indirect measurement of arterial blood pressure in the horse.
Equine veterinary journal    January 1, 1975   Volume 7, Issue 1 22-26 doi: 10.1111/j.2042-3306.1975.tb03224.x
Ellis PM.An accurate modified auscultatory technique for the indirect measurement of arterial pressure in the horse is described. Limitations of the method were sensitivity to external motion in nervous, conscious horses, and the failure to detect Korotkoff sounds in shocked, anaesthetized surgical cases. The apparatus required for the method is expensive and is probably impractical for routine monitoring during anaesthesia.
Cardiac output in the conscious and anaesthetised horse.
Equine veterinary journal    January 1, 1975   Volume 7, Issue 1 16-21 doi: 10.1111/j.2042-3306.1975.tb03223.x
Hillidge CJ, Lees P.Cardiac output in the horse was measured before and at predetermined times during 2-hour periods of thiopentone-halothane and thiopentone-diethyl ether anaesthesia. Left ventricular stroke volume was decreased to a similar extent during anaesthesia with each volatile agent, but a greater reduction in cardiac output occurred during halothane anaesthesia. This finding reflected the differing effects of halothane and ether on heart rate, a slight bradycardia occurring with the former agent while ether produced a small degree of tachycardia. The latter effect was attributed to enhanced sympathoadr...
An interventricular septal defect and a tricuspid valve insufficiency in a trotter mare.
Equine veterinary journal    October 1, 1974   Volume 6, Issue 4 174-176 doi: 10.1111/j.2042-3306.1974.tb03955.x
Muylle E, De Roose P, Oyaert W, van den Hende C.No abstract available
Internal regulation of physiological processes through local venoarterial pathways: a review.
Journal of animal science    September 1, 1974   Volume 39, Issue 3 550-564 doi: 10.2527/jas1974.393550x
Ginther OJ.No abstract available
Studies of whole body oxygenation in conscious and anaesthetised horses.
Archives internationales de pharmacodynamie et de therapie    August 1, 1974   Volume 210, Issue 2 333-346 
Hillidge CJ, Lees P.No abstract available
Heart rate changes in the horse to human contact.
Psychophysiology    July 1, 1974   Volume 11, Issue 4 472-478 doi: 10.1111/j.1469-8986.1974.tb00575.x
Lynch JJ, Fregin GF, Mackie JB, Monroe RR.No abstract available